• Title/Summary/Keyword: Co-Current and Counter-Current

Search Result 51, Processing Time 0.042 seconds

Interaction of Magnetic Flux Ropes in Relation to Solar Eruption

  • Yi, Sibaek;Choe, G.S.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.45.2-45.2
    • /
    • 2018
  • Twisted magnetic flux tubes (also called magnetic flux ropes) are believed to play a crucial role in solar eruptive phenomena. The evolution of a single flux rope with or without the influence of an overlying field of a simple geometry has been extensively studied and its physics is rather well understood. Observations show that interacting flux tubes are often involved in solar eruptions. It was Lau and Finn (1996) who intensively studied the interaction between two flux ropes, whose footpoints are anchored in two parallel planes. In this too simplified setting, the curvature of the flux rope axial fields is totally ignored. In our study, the footpoints of flux ropes are placed in a single plane containing a polarity inversion line as in the real solar active region. Our simulation study is performed for four cases: (1) co-axial field and co-axial current (co-helicity), (2) counter-axial field and co-axial current (counter-helicity), (3) co-axial field and counter-axial current (counter-helicity), and (4) counter-axial field and counter-axial current (co-helicity). Except case 3, each case is found to be related with certain eruptive features.

  • PDF

Operating characteristic of surge counter (Arrester용 Surge counter의 동작특성)

  • Kim, Seok-Sou;Choi, Ike-Sun;Byeon, Jin-Ho;Lee, Kang-Sup;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.30-33
    • /
    • 2004
  • A surge counter is installed under surge arrester, which is protecting the power system apparatuses against abnormal voltage and surges originated in power system line. A surge counter is the device of knowing the times of surge flowed in. There are two methods to get the electric power for mechanical movement and detect the surge. One is using ZnO varistor resister and the other is using the current transformer. In this paper, the characteristics of these methods are presented with using the test and evaluation of them. The process of evaluating the characteristics is essential to develop the domestic surge counter.

  • PDF

Operating characteristic of surge counter (Surge arrester용 surge counter의 동작 특성 평가)

  • Kim, Seok-Sou;Choi, Ike-Sun;Byeon, Jin-Ho;Lee, Kang-Sup;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1134-1137
    • /
    • 2004
  • The main function of surge counter is knowing the times of surge flowed in, which is installed under surge arrester. Two methods are presented in this paper to get the electric power for mechanical movement and detect the surge with surge counter. One is using ZnO varistor resister and the other is using the current transformer.

  • PDF

Modelling and Simulation of H2 separation in Pd Membrane System with Co-current and Current-current Flow (병류와 향류 흐름에서 수소분리를 위한 Pd 분리막 시스템의 모델링 및 모사)

  • Yi, Yong;Noh, Seunghyo;Oh, Min
    • Korean Chemical Engineering Research
    • /
    • v.48 no.5
    • /
    • pp.598-602
    • /
    • 2010
  • In this paper, we carried out CFD modelling and simulation for the membrane system to separate H2 gas from the multi-component feed gas. The membrane system is of the annulus tubular type consisting of the external lumen side for the feed gas and the internal permeation side for the sweeping gas. The operating temperature and pressure of the lumen side inlet flow are $374^{\circ}C$ and 7 bar respectively and those of the sweeping gas are $374^{\circ}C$ and 3 bar, and considering these conditions, Pd membrane system was employed. CFD simulations were performed for the co-current flow and counter-current flow membrane system based on the flow directions between the feed and the sweeping gas. Comparisons and discussions were made for the H2 partial pressure, H2 mole fraction and H2 flux for both cases. Furthermore, we executed CFD simulations for the each case of the various inlet flow rates of the feed gas at the lumen side. Accordingly, we reviewed the effects of the flow rate and residence time on the performance of the membrane system.

Improved Tri-iodide Reduction Reaction of Co-TMPP/C as a Non-Pt Counter Electrode in Dye-Sensitized Solar Cells

  • Kim, Jy-Yeon;Lee, Jin-Kyu;Han, Sang-Beom;Lee, Young-Woo;Park, Kyung-Won
    • Journal of Electrochemical Science and Technology
    • /
    • v.1 no.2
    • /
    • pp.75-80
    • /
    • 2010
  • We report Co-tetramethoxyphenylporphyrin on carbon particles (Co-TMPP/C) as a non-Pt catalyst for tri-iodide reduction in dye-sensitized solar cells (DSSCs). The presence of well-dispersed carbon and cobalt source in the catalyst surface is confirmed by transmission electron microscopy, scanning electron microscopy, and energy dispersive X-ray analysis. In the C 1s, Co 2p, and N 1s peaks measured by X-ray photoelectron spectroscopy, the C-N, Co-$N_4$, and N-C are assigned to the component at 285.7, 781.8, and 401 eV, respectively. Especially, the Co-TMPP/C shows improved current density, diffusion coefficient, and charge-transfer resistance in the ${I_3}^-/I^-$ redox reaction compared to conventional catalysts. Furthermore, in the DSSCs performance, the Co-TMPP/C shows increased short circuit current density, higher open circuit voltage, and improved cell efficieny in comparison with Pt/C.

Analysis of Falling-film Generator in Ammonia-water Absorption System (암모니아-물 흡수식 시스템에서 유하액막식 발생기의 해석)

  • 김병주;손병후;구기갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.5
    • /
    • pp.422-430
    • /
    • 2001
  • In the present study, an evaporative generation process of ammonia-water solution film on the vertical plate was analysed. For the utilization of waste heat, hot water of low temperature was used as the heat source. The continuity, momentum, energy and diffusion equations for the solution film and vapor mixture were formulated in integral forms and solved numerically. Counter-current solution-vapor flow resulted in the refrigerant vapor of the higher ammonia concentration than that of co-current flow. Eve the rectification of refrigerant vapor was observed near the inlet of solution film in counter-current flow. For the optimum operation of generator using hot water, numerical experiments, based on the heat exchange and generation efficiencies. revealed the inter-relationships among the Reynolds number of the solution film and hot water, and the length of generator. Enhancement of heat and mass transport in the solution film was found to be very effective for the improvement of generation performance, especially at high solution flow rate.

  • PDF

A Study on Hydraulic Behavior and Desorption of $CO_2$ Gas in the Counter-current Packing Tower (역류식 충전탑에서 이산화탄소 탈착과 수력학절 거동에 관한 연구)

  • 김석택
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.3
    • /
    • pp.94-100
    • /
    • 2000
  • This study was carried out to interpret hydraulic behavior and CO2 gas desorption in counter-current packing tower which packed 50mm plastic Hiflow-ring. The results are as follow : To compare with conventional packing, 50mm Hiflow-ring could save energy because of low pressure drop under high load. As relative error between calculated value and investigated value was less than 6% in the loading point and flooding point we found that we are predict results mathematically which occur in packing tower. The unique magnitude of packing which was used are as follows. $C_L=2.1{\times}10^{-4}$, n=0.787 so we can predict efficiency which occur

  • PDF

Development of the Lightning Surge Voltage and Current Counters (뇌써지 전압/전류 카운터의 개발)

  • Kil, K.S.;Chang, S.H.;Lee, B.H.;Lee, Y.K.;Lee, B.K.;Ohk, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1882-1884
    • /
    • 1996
  • This paper deals with the lightning surge counter. In order to install the effective surge protective devices, it is important to find the parameters of incident surges. For the purpose of observing the occurrence frequency as a parameter of the amplitude of surge, two type surge counters were designed and fabricated. One is operated by surge currents, and the other is operated by surge voltages. The former consists of current sensor, metal oxide varister (MOV), rectifier, capacitor and electromagnetic counter. The latter consists of rectifier, voltage divider, comparator, photo coupler and counter circuit, and is useful for detecting the surge voltages.

  • PDF

Comparison of Counter-Current Cooling and Pool Boiling System Through Modeling and Simulation of a Pilot-Scale Fixed bed Reactor for Dimethyl Ether(DME) Synthesis (Dimethyl Ether(DME) 합성을 위한 파일럿 규모의 고정층 반응기의 모델링과 모사를 통한 향류 냉각방식과 포화액체 풀비등 방식의 비교)

  • Song, Daesung;Go, Jae Wook;Yoon, En Sup
    • Korean Chemical Engineering Research
    • /
    • v.47 no.4
    • /
    • pp.446-452
    • /
    • 2009
  • The behavior of a one-step fixed bed reactor which directly synthesizes dimethyl ether(DME) from Natural Gas was simulated. In the reactor, the prevention of the occurrence of hot spots which can cause deactivation of catalysts is pivotal, since methanol synthesis and dehydration reaction involved in the synthesis of DME are highly exothermic. Therefore, we simulated and compared performance of the reactor with counter-current cooling and pool boiling system that can be applied to a commercial plant. As a result, we found that counter-current cooling system is more effective in terms of CO conversion and DME productivity. However, pool boiling system can operate in a small temperature gradient that can decrease problems caused by hot spot. And, the system can operate in a safer range.

Suitability of Counter-current Model for Biogas Separation Processes using Cellulose Acetate Hollow Fiber Membrane (셀룰로오스 아세테이트 중공사 분리막을 이용한 바이오가스 분리에 대한 향류 흐름 모델의 적용성)

  • Jung, Sang-Chul;Kwon, Ki-Wook;Jeon, Mi-Jin;Jeon, Yong-Woo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.28 no.4
    • /
    • pp.43-52
    • /
    • 2020
  • As the membrane gas separation technology grows, various models were developed by numerous researchers to describe the separation process. In this work, the counter-current model was compared thoroughly with experimental data. Experimentally, hollow fiber membrane using CA module was prepared for the separation of biogas. The pure gas permeation properties of membrane module for methane, nitrogen, oxygen, and carbon dioxide were measured. The permeance of CO2 and CH4 were 25.82 GPU and 0.65 GPU, respectively. The high CO2/CH4 selectivity of 39.7 was obtained. the separation test for three different simulated mixed gases were carried out after pure gas test, and the gas concentration of the permeate at various stage-cut were measured from CA membrane module. Results showed that the experimental data agreed with the numerical simulation. A mathematical model has implemented in this study for the separation of biogas using a membrane module. The finite difference method (FDM) is applied to calculate the membrane biogas separation behaviors. Futhermore, the counter-current model can be considered as a convenient model for biogas separation process.