• Title/Summary/Keyword: Co-Cr orthodontic wire

Search Result 6, Processing Time 0.02 seconds

THE STUDY 0F TENS10N CHARACTERISTICS IN ORTHODONTIC WIRES (교정용 철사의 인장 특성에 관한 연구)

  • Park, Dae-Han;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.14 no.2
    • /
    • pp.241-248
    • /
    • 1984
  • The mechanical properties of Cr-Ni alloy of austenitic stainless steel and Co-Cr alloy orthodontic wires were studied in tension. The wires (0.018 inch) were tested in the as-manufactured and heat-treated conditions. Instron type tension testing machine was used for this study. Mean values and standard deviations were computed. The results were as follows; 1. The Cr-Ni orthodontic wires of austenitic stainless steel are generally superior than the Co-Cr orthodontic wires in ultimate tensile strength, In the elongation, however, Co-Cr orthodontic wire are superior than Cr-Ni orthodontic wires. 2. Increase in the degree of strength by heat treatment are more clearly shown in Co-Cr orthodontic wires than Cr-Ni orthodontic wires. And the elongation is decreased by heat treatment in both case. 3. The changes of the degree of strength by cooling method we not clearly shown, but in Cr-Ni orthodontic wires, air cooling are more effective, in Co-Cr orthodontic wires, cooling effect are scarcely shown.

  • PDF

An experimental study on the cytotoxicity of orthodontic wires (교정용 호선의 세포독성에 관한 실험적 연구)

  • Lim, Yong-Kyu;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.26 no.5 s.58
    • /
    • pp.591-599
    • /
    • 1996
  • This study was undertaken to investigate the cytotoxicity of orthodontic wires after doing various treatments to the wires. 018x025 inch Stainless steel(A) and Co-Cr(B) wires were used and each of them were divided into 4 groups. A-1 and B-1 groups were as received state, and A-2 and B-2 groups were heat treated. A-3 and B-3 groups were electropolished after heat treatment, and A-4 and B-4 groups were soldered with Ag-solder. Each group had 3 wires and these were sterilized with Ethylene Oxide gas. We used human gingival fibroblast cell culture and agar overlay technique to investigate the cytotoxicity of each group of wires. The cytotoxicity of wire was assessed using reaction index (zone index/lysis index). The findings of this study were as follows. 1. Both of the stainless steel wire and Co-Cr wire showed no cytotoxicity in as received state. 2. Heat treatment or electropolishing of the wires had no effect on the cytotoxicity of the wires 3. Soldered stainless steel wires showed a little wider zone of discoloration than soldered Co-Cr wires, but the zone index and cytotoxicity(reaction index) was not different. 4. Soldered wires showed moderate cytotoxicity in both of the wires.

  • PDF

A comparative study of frictional forces according to orthodontic wires and ligation method under dry and wet conditions (교정선의 종류, 결찰방법, 타액의 유무에 따른 마찰력의 비교연구)

  • Lee, Jin-Woo;Cha, Kyung-Suk;Han, Jung-Suk
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.271-281
    • /
    • 2001
  • The Purpose of this study was fourfold - to evaluate the general laws of friction applied to orthodontic conditions, to compare archwire materials under these controlled conditions, to compare ligation method, and to measure the effect of the artificial saliva on friction with these materials Three wire alloys (Cobalt-chromium, Nickel-titanium, Beta-titanium) in two size wires (.016" , .016" ${\times}$.022" ) were examined respect to the bracket (.018" ${\times}$.025" standard), and two ligature material (stainless steel, elastomeric) in dry and wet conditions The results were as follows, 1. The order of frictional force against alloy materials was Co-Cr (lowest), Ni-Ti, and ${\beta}$-Ti(highest) - with the exception of elastomeric ligation under wet conditions. 2. S.S. ligation gave rise to significantly greater friction than elastomeric ligation did. 3. Testing in the presence of saliva, rather than in dry conditions, decreased the frictional force for S.S. ligation with .016" Co-Cr, Ni-Ti, ${\beta}$-Ti. but, increased the frictional force for S.S. ligation with .016" ${\times}$ .022" Co-Cr, Ni-Ti, ${\beta}$-Ti. 4. .016" ${\times}$.022 " wire generated more friction than .016" wire.

  • PDF

The Frictional Resistance Of Tin Ion-Plated Co-Cr Orthodontic Wire (TiN 피막처리된 Co-Cr계 교정용 선재의 마찰저항력)

  • Lee, Ho-Kyu;Kwon, Oh-Won;Kim, Kyo-Han
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.123-133
    • /
    • 1998
  • The effectiveness of TiN ion-plating was examined with TiN ion-plated Co-Cr wires(.016“, .016”x.022“) on three different types of bracket(TiN ion-plated metal bracket ceramic bracket and plastic bracket). Maximum static frictional forces and characteristic curves obtained from the frictional characteristic graph, were compared and surface roughness of wires and bracket slots before and after friction experiment was observed by SEM. The obtained results were as follows $\cdot$The frictional forces of TiN ion-plated wires were significantly lower than those of non ion-plated wires(p<0.05). $\cdot$On the effect of wire shape, the frictional forces of round wires were significantly lower than those of rectangular wires(p<0.05) $\cdot$As the result of the SEM observation on the wires and bracket slots after the friction experiment the surface of non ion-plated wires was rougher than that of TiN ion-plated ones. $\cdot$The difference between the static frictional forces and the kinetic frictional forces was not significant in case of the TiN ion-plated round ins, but the static frictional forces were a little higher than the kinetic frictional forces in the TiN ion-plated rectangular wires. $\cdot$The static frictional forces were much higher than the kinetic frictional forces in the case of non ion-plated wires.

  • PDF

THE EFFECTS OF HEAT TREATMENT ON THE MECHANICAL PROPERTIES OF THE ELGILOY WIRE (열처리가 Elgiloy 선재의 기계적 성질에 미치는 영향)

  • Hur, Tack;Rhee, Byung-Tae;Choi, Seok Kyu;Kim, Hyung-Il
    • The korean journal of orthodontics
    • /
    • v.22 no.3 s.38
    • /
    • pp.557-578
    • /
    • 1992
  • Heat treatment which removes internal stress enhances the mechanical properties of the orthodontic arch wire. The main purpose of this experiment was to investigate the effects of the heat treatment on the mechanical properties of the Elgiloy wire. The Elfiloy wire, 0.016' X 0.022' and 0.018' X 0.025', were heat treated in an electric oven for 5, 10 and 15 minutes at selected temperatures between 300 and $900^{\circ}C$. Tensile strength and load deflection rate were measured to reveal the changes of mechanical property at various conditions, and each specimen was observed under metallurgic microscope. Also to trace the precipitation material due to overheat treatment, a qualitative analysis was carried out with EDS system. It was found that heat treatment at a low temperature caused an increase in the tensile strength and bending resistance, and a maintenance in the fibrous in the tensile strength and bending resistance, and a maintenance in the fibrous structure of both sizes of wire. The changes observed in properties and appearance were probably due to the relief of internal stresses incurred in the metal during cold working. In both sizes of wire the tensile strength and the bending resistance continued to decrease at high temperature, and the fibrous structure continued to disappear then was not observed at $900^{\circ}C$. The carbide precipitation founded in grain boundary at $750^{\circ}C$ probably was other elements carbide (Ni, Co) except Cr. The grain growth was observed at $1100^{\circ}C$. Optimum heat treatment for the 0.016' X 0.022' Elgiloy wire was 10 minutes at $500^{\circ}C$, and for the 0.018' X 0.025' Elgiloy wire it was 5 to 15 minutes at $500^{\circ}C$.

  • PDF

THE PHYSICAL PROPERTIES OF TIN ION-FLAYED CO-CR(ELGILOY) ORTHODONTIC WIRES (TiN 피막처리된 Co-Cr계 교정용 선재의 물성)

  • KIM, Jung-Min;KWON, Oh-Won;KIM, Kyo-Han
    • The korean journal of orthodontics
    • /
    • v.28 no.3 s.68
    • /
    • pp.371-377
    • /
    • 1998
  • To estimate the possibility of clinical application of TiN ion-Plated Elgiloy(Co-Cr wire), measurements of tensile strength and hardness were made on the four tempers on each of the manufactured Elgiloy, the (heat-treated) Elgiloy for 30 minutes at $250^{\circ}C$ and the TiN ion-plated Elgiloy. For comparison, the tensile strength and hardness of Stainless Steel wires were also measured. The following are the results of the study: $\cdot$In the 4 tempers, tensile strength was the greatest in the TiN ion-plated group, followed by the heat-treated Elgiloy group and the manufactured Elgiloy group, but no statistical difference was noticed between heat-treated and manufactured Elgiloy groups(p>0.05). $\cdot$In each temper, tensile strength of ion-plated Elgiloy increased about $10kgf/mm^2$ in comparison with the values of the manufactured Elgiloy $\cdot$In yellow, green and red tempers except the blue, hardness was the greatest in ion-plated group. In the blue temper, there was no statistical difference between heat-treated and manufactured Elgiloy groups(p>0.05). $\cdot$In each temper, hardness of ion-plated Elgiloy increased about 50-90VHN in comparison with the values of the manufactured Elgiloy. $\cdot$The tensile strength of Stainless Steel wire was similar to that of the red temper of manufactured Elgiloy and the green temper of ion-plated Elgiloy.

  • PDF