• Title/Summary/Keyword: Clothing humidity

Search Result 193, Processing Time 0.025 seconds

Comparison of the Effect of Clothing Materials and the Openness of Garment on the Microclimate of the Skin Simulating System (의복재료와 개구부 요인이 의복내 미세기후에 미치는 영향력 비교)

  • 유화숙;김은애
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.6
    • /
    • pp.1084-1095
    • /
    • 1996
  • The purpose of this study was to compare the effect of clothing materials and the opening of the garment on the microclimate of the skin simulating system during the coupled heat and moisture transfer. To determine the effect of size and location of openness of the garment, openness was simulated by removing parts of the spacer ring of the modelling system. To evaluate the changes of humidity and temperature of air layer in the system, buffering indice, Kd and Pr, and efficiency of openness were determined. When the openness was imparted to the system, the transport rate of heat and moisture increased abruptly; at the total openness of 26.4%, which simulated the openness of neck, armhole and waist, Kd increased at least more than three times of the closed system. As the openness increased, the effect of clothing materials decreased gradually to lose its effect at the 60% openness and approached the value of nude. Temperature regulating index showed, however, higher value than nude which was apparently due to the still air layer.

  • PDF

Moisture and Heat Transfer Characteristics of Waterproof and Water Vapor Permeable Coated Fabrics (기능성 투습방수 코팅포의 수분 및 열전달 특성)

  • Cho, Ji-Hyun;Ryu, Duck-Hwan
    • Korean Journal of Human Ecology
    • /
    • v.8 no.1
    • /
    • pp.151-163
    • /
    • 1999
  • The purpose of this study was to investigate the thermal resistance and the liquid/vapor water transfer characteristics of four waterproof and water vapor permeable coated fabrics with the ground fabric called nylon taffeta. In order to establish the experimental environment, outdoor temperature and humidity in Taegu during the last three years were examined and the experiment was performed at (1) $15^{\circ}C$, 50% R.H., (2) $20^{\circ}C$, 60% R.H., (3) $25^{\circ}C$, 65% R.H., which were the average standards in spring and fall. The test results were as follows ; 1. Among physical parameters, the thinner the thickness was, the higher the water vapor permeability was. But the porosity in thickness was not proportional to water vapor permeability linearly. 2. The thicker the thickness of specimens was and the smaller the bulk density and porosity were, the higher the thermal resistance. And the results also shown that the larger the temperature difference between the environmental temperature and the hot plate was, the more the difference of CLO values was apparent. 3. Since the contact angle of all specimens are above $90^{\circ}$, the all specimens have a good performance in waterproof. The more the specimens surface were rough, the higher the thermal resistance was. 4. According to the result of performing moisture transfer test using the simulating body skin-clothing-environment system, the humidity sensor placed in between the fabric and the environment detected the full saturation in 10 minutes after the experiment had began at $15^{\circ}C$, 50% R.H. and in 15 minutes after the experiment both at $20^{\circ}C$, 60% R.H. and at $25^{\circ}C$, 65% R.H. 5. ${\Delta}$ values of the humidity sensors placed in between the human body and the fabric and in between the fabric and the environment fluctuated repeatedly within the range of $20{\sim}40%$ at $20^{\circ}C$, 60% R.H., and $15{\sim}30%$ at $25^{\circ}C$, 65% R.H.

  • PDF

The Classification and Investigation of Smart Textile Sensors for Wearable Vital Signs Monitoring (웨어러블 생체신호 모니터링을 위한 스마트텍스타일센서의 분류 및 고찰)

  • Jang, Eunji;Cho, Gilsoo
    • Fashion & Textile Research Journal
    • /
    • v.21 no.6
    • /
    • pp.697-707
    • /
    • 2019
  • This review paper deals with materials, classification, and a current article investigation on smart textile sensors for wearable vital signs monitoring (WVSM). Smart textile sensors can lose electrical conductivity during vital signs monitoring when applying them to clothing. Because they should have to endure severe conditions (bending, folding, and distortion) when wearing. Imparting electrical conductivity for application is a critical consideration when manufacturing smart textile sensors. Smart textile sensors fabricate by utilizing electro-conductive materials such as metals, allotrope of carbon, and intrinsically conductive polymers (ICPs). It classifies as performance level, fabric structure, intrinsic/extrinsic modification, and sensing mechanism. The classification of smart textile sensors by sensing mechanism includes pressure/force sensors, strain sensors, electrodes, optical sensors, biosensors, and temperature/humidity sensors. In the previous study, pressure/force sensors perform well despite the small capacitance changes of 1-2 pF. Strain sensors work reliably at 1 ㏀/cm or lower. Electrodes require an electrical resistance of less than 10 Ω/cm. Optical sensors using plastic optical fibers (POF) coupled with light sources need light in-coupling efficiency values that are over 40%. Biosensors can quantify by wicking rate and/or colorimetry as the reactivity between the bioreceptor and transducer. Temperature/humidity sensors require actuating triggers that show the flap opening of shape memory polymer or with a color-changing time of thermochromic pigment lower than 17 seconds.

Developing a Multi-Functional Smart Down Jacket Utilizing Solar Light and Evaluating the Thermal Properties of the Prototype (태양광을 활용한 스마트 다운재킷 개발 및 보온성능 평가)

  • Yi, Kyonghwa;Kim, Keumwha
    • Journal of Fashion Business
    • /
    • v.19 no.4
    • /
    • pp.92-108
    • /
    • 2015
  • This study aimed at developing a down jacket prototype that utilized sunlight as an alternative energy source with no air pollution. The jacket is filled with flexible solar panels and has a heat-generating function and LED function. In this study, three smart down jacket prototypes were developed, and the jacket's capabilities were demonstrated through the thermal effect on the performance test. The typical output voltage of the flexible solar panels was 6.4V. By connecting the 2 solar cell modules in series, the final output voltage was 12.8V. A battery charge regulator module was used the KA 7809 (TO-220) of 9V. Three heating pads were to be inserted into the belly of the jacket as direct thermal heating elements, and the LED module was configured, separated by a flash and an indicator. The smart down jacket was designed to prevent damage to the down pack without the individual devices' interfering with the human body's motion. Because this study provides insulation from extreme cold with a purpose, the jacket was tested for heat insulation properties of non-heating, heating on the back, heating on the abdomen, and heating on both the back and abdomen in a sitting posture in a static state. Thermal property analysis results from examining the average skin temperature, core temperature, and the temperature and humidity within clothing showed, that placing a heating element in one place was more effective than distributing the heating elements in different locations. Heating on the back was the most effective for maintaining optimal skin temperature, core temperature, and humidity, whereas heating on the abdomen was not effective for maintaining optimal skin temperature, core temperature, or humidity within clothing because of the gap between the jacket and the body.

Effect of Phenolic Resin According to Relative Humidity on Submerged Entry Nozzle with ZrO2-C System in Fabrication Process (ZrO2-C계 침지노즐 제조시 상대습도에 따른 바인더용 페놀수지의 영향)

  • Yoon, Sang-Hyeon;Kim, Jang-Hoon;Kim, Ju-Young;Lee, Hee-Soo;Koo, Young-Seok
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.4
    • /
    • pp.293-297
    • /
    • 2011
  • The thermodynamic behavior of phenolic resin was investigated to verify the relation between the properties of porous ceramics with $ZrO_2$-C system for submerged entry nozzle and the characteristics of phenolic resin with various relative humidity. The green and the sintered density were decreased between 25% and 50% relative humidity, whereas they were gradually enhanced above 50% relative humidity. The highest value of apparent porosity was 20.1% and the minimum compressive strength was 69MPa in the specimen using the powder exposed to 50% relative humidity. As a result of thermal analysis for phenolic resin, the shift of endothermic peak to low temperature and the reduction of exothermic peak were observed, and the peaks corresponded to melting and curing of phenolic resin, respectively. The melting and the curing of phenolic resin generate the change of green density, and it can affect the properties of submerged entry nozzle.

The Psycho-physiological Response of Polyethylene Terephthalate Irradiated by Ultra-Violet: Subjective Fabric Hand and Wear Comfort

  • Choi, Hae-Young;Lee, Jung-Soon
    • Fibers and Polymers
    • /
    • v.7 no.4
    • /
    • pp.442-445
    • /
    • 2006
  • The purpose of this study was to compare the subjective fabric hand evaluation and wear comfort of PET treated by Ultraviolet and to evaluate the subjective results from the investigation of microclimate temperature. The subjective hand evaluation was performed by 20 subjects (age: 20-25) with 5-point scale questionnaires to investigate the change of PET knit fabrics treated for different times, specifically, 0, 30 and 90 minutes. The questionnaires were composite with 8 questions; roughness, smoothness, wetness, stiffness, coolness, touch, preference, and comfort. In order to evaluate sensations of wear comfort, we made garments with UV treated fabric and five female students were tested. They walked at the speed of 6.7 km/ hr for 15 minutes in an environment, which was controlled at $29^{\circ}C,\;75{\pm}5%$ RH. Before and after exercising, the microclimate under clothing and subjective wear comfort was measured. The results of subjective evaluation of fabric hand were that untreated and treated for 30 minutes PET were recognized as similar and have a good evaluation on comfort, preference, and touch. According to the result of wear comfort, clothing treated by UV for 90 minutes had the lowest value on the thermal and humidity sensations. In addition, the value of tactile and comfort sensation was the highest on the clothing treated by UV for 90 minutes. In the case of objective evaluation, PET treated for 90 minutes was the lowest on microclimate humidity. PET irradiated by UV for 90 minutes was more 'cool' in thermal sensation and more 'dry' in wet sensation. Accordingly, it was consistent with the result of subjective wear comfort.

A Survey on the Actual Conditions of Summer Working Uniforms for Contracted Foodservice Workers (위탁급식업체 종사자의 하절기 작업복 착용 실태에 관한 연구)

  • Lee, Hyo-Hyeon;Yeom, Jeong-Ha;Choi, Jeong-Wha
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.4
    • /
    • pp.553-562
    • /
    • 2010
  • This survey investigates the conditions of summer working uniforms for contracted foodservice workers. The data were obtained from 67 workers through in-depth interviews (July 2005~October 2005). The results of study are as follows: The working environment changed to menu and cooking method (air temperature $28\sim37^{\circ}C$, humidity 72~86 %RH, radiant temperature $27\sim37^{\circ}C$, air velocity 0.14~0.37m/sec). They answered that the working environment has high temperatures, humidity, excessive noise, and liability to slide. The typical accidents were burns, cuts, slide, and ligament injuries in the workplace. Work duties consisted of cooking, serving food, washing, and cleaning up leftover food. All the employees carried out multi tasks. The primary working postures and motions were standing, crouching, and lifting. The female workers usually wore underwear (panty and brassiere), upper and lower work wear, aprons, waterproof-aprons, cotton-gloves, rubber-gloves, socks, and rubber-boots. The satisfaction of the uniform was relatively low for trousers and waterproof-aprons. The answer about the fit was generally "comfortable." They answered "back," "chest," and "head" were wet with perspiration during work. The uncomfortable parts were the crotch and neck. Questions concerning their satisfaction with the material of uniforms indicated a high rate of dissatisfaction, particularly for ventilation and absorbency. In case of the colors of the working uniform, workers preferred white color for the upper part, and black color for the lower part.

Thermal Properties on combination of Velvet and Lining (벨벳과 안감의 소재 조합에 따른 의복의 열저항에 관한 연구)

  • 계명대학교의류학과;이욱자;류덕환
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.1
    • /
    • pp.3-13
    • /
    • 1999
  • This study was performed for purpose of getting fundamental information requisite to wear velvet clothes that is more comfortable for the human body and also the environment. It was carried out in a human wearing test and thermal manikin test at the same time in a controlled-condition chamber. The experimental environment had a ambient temperature of 15$\pm$0.5$^{\circ}C$ with the relative humidity at 5$^{\circ}C$$\pm$5% and with air velocity at less that than 0.2m/sec. Velvet differ from common plain weaves in thermal properties because it's constructed in two parts one is ground part and the other part is pile part. In order to investigate the thermal resistance of velvet eight different combination of 4 velvet kinds and 2 lings kinds as experimental clothes. [(4 velvet kinds : Acetate cuprammoium Rayon Cotton Wool) (2 lining kinds : acetate viscose rayon)longrightarrow8 combination: Aa, Av, Ra, Rv, Ca, Cv, Wa, Wv: the simplified character] The results of this study can be summarized as follows : 1. For the regional thermal resistance the differences in eight clothes as well as differences in each part were significant. As a whole the breast part showed the highest thermal resistance and the leg part was higher than the shank part. The rank of the total thermal resistance was put at Wa>Wv>Ca>Cv>Aa>Av>Ra>Rv in this order. 2. Considered clothing microclimate microclimate temperature has a similar tendency to the total thermal resistance. It showed a significance in the differences of eight clothes and each parts. the belly part was highest in every combination. On the other hand for clothing humidity there was a significance between back and breast part only in the human wearing test. 3. It was indicated that CLO value was highly positively correlated with the clothings' weight and showed a high negative correlation with the air permeability.

  • PDF

Measurement of Thickness of Still Air Layer above Fabrics (직물의 표면 정지 공기층의 두께 측정)

  • 나영주
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.7
    • /
    • pp.1117-1123
    • /
    • 1997
  • This paper describes the measurement of thickness of still air layer above fabrics and its relationship to structural properties of fabrics. Rayon fabrics - of both filament and spun - and wool nylon blended fabrics varied in terms of surface hairiness were used. Temperature and relative humidity above fabrics were measured at the various distances from the fabric surface. Increase in the thickness of fabric, fabric weight, yarn count, and crimp resulted increase in thickness of still air layer above fabric. Surface hairiness of fabrics as well as the structural properties were found to be related with the thickness of still air layer above fabrics.

  • PDF

Effects of Hair Style on Human Physiological Response in a Thermal Neutral Environment (쾌적 환경에서 헤어스타일 유형이 인체 생리 반응에 미치는 영향)

  • Kim, Myung-Ju
    • The Korean Journal of Community Living Science
    • /
    • v.21 no.1
    • /
    • pp.117-124
    • /
    • 2010
  • Recently, research on variables associated with hair styles are increasing with the spreading of total coordinated intention in the fields of clothing and cosmetology. In the present study, we focused on examining the skin temperature on the scalp(the vertex, temporal, and occiput), humidity on the occiput, skin temperatures (the forehead, back of ear, back of neck, upper back, abdomen, forearm, hand, thigh, calf, and foot), rectal temperature, total body mass loss by hair styles in a thermal neutral environment. Four young females participated as subjects. For a certain period, each subject had the five different hair styles in a random order: (1)Straight short hair(SS), (2)Perm waved short hair(PS), (3) Straight long hair(SL), (4)Perm waved long hair(PL), (5)Ponytail style(PT). Subjects wore briefs, bra, shirts with long sleeves, long legged training pants, and socks. The environmental variables of a climatic chamber were kept constant at $21{\pm}0.5^{\circ}C$ of air temperature and 55${\pm}$5%RH of air humidity. The results indicated the following: The skin temperature and humidity on the scalp did not show any significant differences among five different hair styles, but straight long hair style(SL)was the highest on the vertex, temporal, and occiput. The temporal skin temperature($29.8\sim30.8^{\circ}C$) was the highest, while the vertex skin temperature($28.7\sim30.1^{\circ}C$) was the lowest. Humidity on the occiput was the highest in the perm waved long hair style(PL). The back of ear skin temperature was significantly lower in the ponytail style(PT) than in the other four hair styles(p<.001). In the straight long hair style(SL), the skin temperature on the back of the neck and on the upper back were significantly higher than those of the other four hair styles(p<.01). Mean skin temperature and rectal temperature had no significant differences among hair styles. Total body mass was the highest in the perm waved long hair style(PL)(p<.05). We acquired fundamental data to enable the improvement of the current hair clinic system, wigs, functional hats, and helmets.