• Title/Summary/Keyword: Closing Department

Search Result 456, Processing Time 0.036 seconds

Failure Examples Study Including with timing belt, Constant Velocity Boot and Weather strip on a Car (자동차의 타이밍벨트, 등속조인트 부트, 웨더 스트립에 관련된 고장사례 고찰)

  • Lee, Il Kwon;Lee, Jong Ho;Hwang, Han Sub;Yim, Ha Young;You, Chang Bae;Kim, Young Kyu;Kim, Choo Ha
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.1
    • /
    • pp.6-11
    • /
    • 2015
  • This paper is to study the examples for rubber damage and weaken reliability of timing belt, constant velocity joint boot and weather strip in vehicle. The first example, when the service man replaced the new timing-belt of rubber material, he assembled the belt that was weaken it's contact surface because of material transform. He knew the abnormally tearing failure by friction action between belt and sprocket. The second example, it certified the fact that the grease is leaked out boot protecting of constant velocity joint by split of rubber surface because of durability badness. The third example, the weather stripe took the minutely tearing because of damage produced the material transform by crack of chemistry change. It certified the production phenomenon of a tiny noise by coming with outside air because of overlapped the rubber of weather stripe when driving after closing the door. Therefore, the driver must always manage the rubber system part of vehicle.

Opening Exercise Therapy with Locking-free Appliance(LA) : Preliminary Study (Locking-free Appliance(LA)를 이용한 개구운동치료 : 예비실험)

  • Jung, Won;Lee, Kyung-Eun;Sun, Sae-Ah;Suh, Bong-Jik
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.1
    • /
    • pp.29-34
    • /
    • 2013
  • Objective: All patients who have the disc displacement with reduction (DDwR) are always not progressive but some of them with significant catching or locking progress to disc displacement without reduction (DDw/oR). In this study, we suggest opening exercise therapy using Locking-free Appliance (LA) to be helpful to prevent progressive derangement. Methods: Retrospectively, a total 37 patients who received exercise treatment using LA was analyzed from January 2010 to December 2011. Patients had been instructed in proper exercise technique to practise for opening and closing of mouth wearing the appliance 30 times a day in locking-free position. Results: None of the patients took a turn for worse to DDw/oR (37 patients). The 16 patients (43.2%, locking-free group) of them could open their mouth without intermittent condylar locking. Measurement of data was analyzed using and Mann-Whitney test. There was no statistically significant difference for age, gender, presence of palpational pain, locking period, VAS quantitative pain score between locking-free group and locking group. Conclusions: In this study, some patients could open their mouth without intermittent locking and did not take a turn for worse to DDw/oR after opening exercise therapy with LA. Furthermore, LA had advantages which were short wearing time, low costs and minimizing patients' uncomfortable compared to conventional treatment method. This therapy can be more appropriate new treatment to prevent progress to DDw/oR.

COMPARISON OF BITE FORCE WITH DENTAL PRESCALE AND UNILATERAL BITE FORCE RECORDER IN HEALTHY SUBJECTS (Dental Prescale과 편측 교합력 측정기를 이용한 정상성인의 교합력 비교)

  • Kwon Ho-Keun;Yoo Ja-Hea;Kwon Young-Sook;Kim Baek-Il
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.103-111
    • /
    • 2006
  • Statement of problem: The previous unilateral bite force recorder has several limitations for taking long time for measuring and causing discomfort to subjects. Because of these reasons, it could not use widely for epidemiological researches. However, 'Dental Prescale System' which is new equipment for measuring bite force, is more convenient for measuring bite force than previous unilateral recorder. Purpose: The purpose of this study was to compare a new technique(Dental Prescale System) using pressure sensitive foils for recording of maximal jaw closing force with conventional measurement using unilateral bite force recorder Material and method: This studies included 22 healthy dental students in college of dentistry Yonsei university in Rep of Korea. Mean age was 23.9 years. All subjects had continuous dental arches and no significant malocclusion or signs from the teeth and craniomandibular system. The Dental Prescale System (Fuji Film, Tokyo, Japan) consists of a horseshoe-shaped pressure sensitive sheet (50H, R type) and a computerized scanning system.(FPD705) We also used unilateral bite force recorder(Denbotics Co. Seoul, Rep.Korea) for comparing with Dental Prescale. Results and conclusion: The total bite force recorded with Dental Prescale System (1423 N) was systematically higher than that recorded by unilateral bite force recorder. (256 N) However, the maximum bite force values measured in the two ways were significantly correlated (r=0.46, p<0.05). The Dental Prescale bite force calculated for first molar (208 N) was lower than that recorded by unilateral bite force recorder. (256 N) The two values were also very significantly correlated. (r=0.66. p<0.001) There were significantly different in bite force between two measurement methods. The reasons were first, unilateral bite force recorder measured only the bite force of a part of teeth, and Dental Prescale measured the total teeth force. Second, in measurement, a difference in muscle contraction appeared by an extent of mouth-opening. Third, unilateral bite force recorder has the reducing effect of the bite force by protective tape. Fourth, Dental Prescale has limitations during the computer scanning procedure. Therefore, Dental Prescale System is considered to be a very promising alternative to be conventional bite force recording methods.

Analysis of Causes of and Solutions to the Stack Effect by Vertical Zoning of High-rise Buildings (초고층 건축물 수직조닝별 연돌효과의 원인 및 해결 방안 분석)

  • Shin, Sang Wook;Ryu, Jong Woo;Jeong, Hee Woong;Kim, Dae Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.5
    • /
    • pp.483-493
    • /
    • 2021
  • Urban overcrowding has created an explosive supply and demand for high-rise buildings. High-rise buildings are contributing to enhancing the image of the city by serving as focal points, but due to the stack effect, malfunction of elevator doors, difficulties in opening and closing the doors and windows of the outer wall, smoke and odors spreading to the upper floors, noise, energy loss, fire and pollutants have been causing various unexpected problems such as rapid spread of fire. This study classified high-rise buildings according to their vertical zoning, analyzed the causes of and solutions to the stack effect, and derived design and construction methods. Through the initial plan to block the outside air and securing airtightness through precise construction, we sought ways to secure the airtightness inside and outside the building by actively blocking the airflow from the lower floors. In addition, the facility solution can be a measure to reduce the specific phenomena caused by the stack effect, but it should only be applied to the minimum extent because the potential for secondary damage is high. This study emphasized the need for systematic stack effect management by suggesting design and construction measures for each vertical zoning of the causes and countermeasures of the stack effect. It is expected that this study will be helpful not only for design and construction, but also for building maintenance.

MANAGEMENT OF DIASTEMA AFTER REMOVAL OF MESIODENS (정중 과잉치 발거 이후 정중 이개의 폐쇄)

  • Cho, Eun-Ju;Choi, Yeong-Chul;Lee, Keung-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.348-353
    • /
    • 2003
  • Early detection and prudent management of mesiodens or supernumerary tooth should be considered essential in reducing disturbance in the eruption and position of the adjacent permanent incisor. While it is true that the presence of diastema may be regarded as normal at the early mixed dentition stage, the early detection and removal of the mesiodens is a prerequisite to facilitate spontaneous alignment or subsequent approximation of the permanent central incisors. In many cases, diastema due to mesiodens can be physiologically corrected spontaneously after the extraction of mesiodens. The best choice of treatment of diastema may be observation. Orthodontic intervention is required only spontaneous closing of diastema does not occur within observation period. In orthodontic intervention, careful treatment plan should be established. Clinician gives considerations to angulation of central and lateral incisor, proximity of lateral incisor, developmental stage and position of canine, pattern and extent of anterior crowding. Orthodontic movement should be done slowly with light force. In addition, periodic radiographic observation are needed to monitor the root development and root resorption. Case 1, 2 and 3 showed physiologic closures after the extraction of mesiodens. In these cases, acceptable alignment of central and lateral incisors was obtained. In case 4, orthodontic correction for diastema was performed successfully after the extraction of mesiodens. After the orthodontic closure of the diastema, it was decided that a retainer was not needed, because the dentition was under a dynamic stage in exchanging teeth and also developing arches.

  • PDF

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS FOR REACTION TO MOLAR UPRIGHTING SPRING (대구치 직립 스프링 적용시 반작용에 관한 삼차원 유한요소법적 연구)

  • Choe, Yoo-Kyung;Kim, Tae-Woo;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.61-74
    • /
    • 1998
  • The Purpose of this study was to investigate the stress distribution and tooth displacement at the initial phase produced by 5 types of molar uprighting springs using finite element method. The three dimensional finite element model of lower dentition, bone and springs was composed of 5083 elements and 2071 nodes. The results were as follows: 1. In case of helical spring and root spring, intrusion of lower canine and first premolar were observed md distal tipping, translation and extrusion of lower second molar were observed. 2. In case of T-loop, modified T-loop and box loop, intrusion and distal translation of lower second premolar were observed, and the largest crown distal tipping and translation of lower second molar were observed in T-loop and the smallest were observed in box loop. 3. In case of T-loop with cinch-bact crown distal tipping and translation of lower second molar were decreased, but extrusion was also decreased. 4. With increase of activation in T-loop, mesial translation and won distal tipping of lower second molar were increased and edentulous space was closing, but distal translation of second premolar was also increased. 5. With increase of tip-back bend in T--loop, distal tipping and translation of lower second molar were increased, but extrusion was also increased more largely.

  • PDF

Mesozooplankton Community Dynamics in Watan Stream, Yeonggwang, Korea (영광 와탄천의 중형동물플랑크톤 군집동태)

  • Lee, Dong-Ju;Kim, Say-Wa;Lee, Won-Choel
    • Korean Journal of Environmental Biology
    • /
    • v.27 no.4
    • /
    • pp.425-432
    • /
    • 2009
  • Mesozooplankton dynamics were studied in Watan stream which flows into the Yellow Sea in Yeonggwang, Korea. Samples were collected at eight stations bimonthly during April 2006~February 2007. Mesozooplankton community was consisted of 45 taxa (8 cladocerans and 29 cope-pods). The abundance varied between the highest one ($31{\sim}127,587\;indiv.m^{-3}$) in October, and the lowest ($12{\sim}233\;indiv.m^-3$) in December. Diversity index showed to be the highest value in July (0.671) and the lowest one in August (0.368). A euryhaline species, Acartia hongi was dominant in brackish water stations (the highest abundance at $13.4^{\circ}C$ and 14.1 psu). In freshwater stations of the upstream, two cladoceran species of Polyphemus pediculus and Moina weismani occurred in high abundance in August. Dominant taxa of copepod were clustered to two or three groups mainly due to the difference of salinity gradients. Spatial distribution of mesozooplankton revealed to be determined by salinity gradients which were affected by opening and closing of the artificial dam in Watan stream.

Development of Smart Switchgear for Versatile Ventilation Garments: Optimum Diameter and Voltage Application Unit Time of One-way Shape Memory Alloy Wire for a Bi-directional Actuator (가변 통기성 의복을 위한 스마트 개폐장치 개발: 양방향 작동 액추에이터 제작을 위한 일방향 형상기억합금 와이어의 최적 직경 및 전압인가 단위시간의 도출)

  • Kim, Sanggu;Kim, Minsung;Yoo, Shinjung
    • Science of Emotion and Sensibility
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2018
  • The study figured out the operational conditions of a two-way movement actuator made of one-way shape memory alloy (OWSMA) for versatile ventilation intelligent garments. To develop a low-power actuator that consumes energy only when a garment changes its form such as opening and closing, multiple channels of OWSMA were used, and optimum diameter of the wires was examined. For the switch device, optimum voltage application unit time was determined. Optimum diameter of OWSMA wire was determined by applying 3.7V to the pre-determined candidate diameters, which demonstrated two-way operation in previous studies. In order to evaluate the optimum voltage application time, the internal diameter of the actuator was measured while increasing and decreasing by 50 ms from the unit time of voltage application. Delay time under two-way operation of the actuator was measured to minimize interference caused by heat between channels. Power of 3.7V was applied to OWSMA for assessment of optimal time, and the whole process from heating to cooling was video-recorded with a thermal image camera to determine the point of time at which the temperature of OWSMA wire dropped below the phase transformation temperature. The results showed that $0.4{\Phi}$ was the most suitable diameter, and the optimum unit time of voltage applied to open and close the actuator was 4100ms. It was also shown that the delay time should be more than 1.8 seconds between two-way operations of the actuator.

Thermal-hydraulic behaviors of a wet scrubber filtered containment venting system in 1000 MWe PWR with two venting strategies for long-term operation

  • Dong, Shichang;Zhou, Xiafeng;Yang, Jun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1396-1408
    • /
    • 2020
  • Filtered containment venting system (FCVS) is one of the severe accident mitigation systems designed to release containment pressurization to maintain its integrity. The thermal-hydraulic behaviors in FCVSs are important since they affect the operation characteristics of the FCVS. In this study, a representative FCVS was modeled by RELAP5/Mod3.3 code, and the Station BlackOut (SBO) was chosen as an accident scenario. The thermal-hydraulic behaviors of an FCVS during long-term operation with two venting strategies (open-and-close strategy, open-and-non-close strategy) and the sensitivity analysis of important parameters were investigated. The results show that the FCVS can operate up to 250 h with a periodic open-and-close strategy during an SBO. Under the combined effects of steam condensation and water evaporation, the solution inventory in the FCVS increases during the venting phase and decreases during the intermission phase, showing a periodic pattern. Under this condition, the appropriate initial water level is 3-4 m; however, it should be adjusted according to the environment temperature. The FCVS can accommodate a decay heat power of 150-260 kW and may need to feed water for a higher decay heat power or drain water for a lower decay heat power during the late phase. The FCVS can function within an opening pressure range from 450 kPa to 500 kPa and a closing pressure range between 250 kPa and 350 kPa. When the open-and-non-close strategy is adopted, the solution inventory increases quickly in the early venting phase due to steam condensation and then decreases gradually due to the evaporation of water; drying-up may occur in the late venting phase. Decreasing the venting pipe diameter and increasing the initial water level can mitigate the evaporation of the scrubbing solution. These results are expected to provide useful references for the design and engineering application of FCVSs.

Evaluation of Automatic Image Segmentation for 3D Volume Measurement of Liver and Spleen Based on 3D Region-growing Algorithm using Animal Phantom (간과 비장의 체적을 구하기 위한 3차원 영역 확장 기반 자동 영상 분할 알고리즘의 동물팬텀을 이용한 성능검증)

  • Kim, Jin-Sung;Cho, June-Sik;Shin, Kyung-Sook;Kim, Jin-Hwan;Jeon, Ho-Sang;Cho, Gyu-Seong
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.178-185
    • /
    • 2008
  • Living donor liver transplantation is increasingly performed as an alternative to cadaveric transplantation. Preoperative screening of the donor candidates is very important. The quality, size, and vascular and biliary anatomy of the liver are best assessed with magnetic resonance (MR) imaging or computed tomography (CT). In particular, the volume of the potential graft must be measured to ensure sufficient liver function after surgery. Preoperative liver segmentation has proved useful for measuring the graft volume before living donor liver transplantations in previous studies. In these studies, the liver segments were manually delineated on each image section. The delineated areas were multiplied by the section thickness to obtain volumes and summed to obtain the total volume of the liver segments. This process is tedious and time consuming. To compensate for this problem, automatic segmentation techniques have been proposed with multiplanar CT images. These methods involve the use of sequences of thresholding, morphologic operations (ie, mathematic operations, such as image dilation, erosion, opening, and closing, that are based on shape), and 3D region growing methods. These techniques are complex but require a few computation times. We made a phantom for volume measurement with pig and evaluated actual volume of spleen and liver of phantom. The results represent that our semiautomatic volume measurement algorithm shows a good accuracy and repeatability with actual volume of phantom and possibility for clinical use to assist physician as a measuring tool.

  • PDF