• Title/Summary/Keyword: Closed pattern

Search Result 278, Processing Time 0.028 seconds

Analysis on the Current distribution and its Rodiating Electric Field of the arbitrary linear Antenna (임의의 선형 안테나의 전류분포와 그 복사전계해석)

  • 주창복
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.5 no.1
    • /
    • pp.76-82
    • /
    • 1980
  • In this paper, an arbitrary Iinear antenna is divided into many small sections and numeral analysis by moment method is carried out. So, the equation which is closed to the actual current distribution and solved easily compared with the induced-emf method or retarded potencial method is derived. The current distribution and radiating pattern of the three element Yagi antenna which applied the result is well in accord with the theoritical values.

  • PDF

An Study on the Structure of Maghemite(${\gamma}$-Fe$_2$O$_3$) I -Rietveld Analysis of Powder XRD Patterns- (마게마이트(${\gamma}$-Fe$_2$O$_3$)대한 연구 I -분말 X-선 회절무늬의 Rietveld 분석-)

  • 신형섭
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.10
    • /
    • pp.1113-1119
    • /
    • 1998
  • Crystal structure of needle-shaped maghemite(${\gamma}$-{{{{ { {Fe }_{2 }O }_{3 } }}) has been studied by the Rieveld analysis of powder X-ray diffraction patterns. The tetragonal space group P41,.3212 and cubic space group P41,.32 have been have been used for the refinement of X-ray diffraction patterns. The crystal system of maghemite is closed to tetragonal more than cubic. The tetragonal lattice parameters are a=8.3460$\AA$ and c=25.034$\AA$ The standard X-ray diffraction pattern of the tetragonal maghemite analyzed with space group P41,.3212 is proposed.

  • PDF

Elution Behavior of Nutrient Salts from Sediment and its Impact on Water Bodies

  • Wada, Keiko;Haruki, Fumio;Ishita, Kyoji;Okada, Yuki
    • Environmental Engineering Research
    • /
    • v.15 no.1
    • /
    • pp.41-48
    • /
    • 2010
  • This paper describes the influence of nutrient salts eluted from the bottom of a closed water area where polluted sediment has been deposited by inflowing river water. The elution pattern was monitored at our experimental facility. Both the sediment pore water and water above the bottom were sampled using a dialyzer sampler (peeper). The pore water of the eutrophicated sediment contained a large amount of nutrient salts, and the effect of elution was confined to a limited area of the bottom surface. The nutrient concentration of the sediment pore water was closely related to both the water temperature and dissolved oxygen (DO) concentration. The eluted nutrients from the sediment provided a source for phytoplankton and algae growth. This experimental data indicated that the water quality of the surface was not directly connected to the eluted nutrient salts, while it was indirectly affected by the total ecosystem, including all the organisms within an area and their environment.

An Analysis of the Acoustic Radiation Characteristics from the Acoustic Transducer (압전세라믹스를 이용한 음향트랜스듀서의 음향방사특성 해석)

  • 노현택;고영준;박재성;남효덕;장호경
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.703-706
    • /
    • 2000
  • The acoustic characteristics radiated from the acoustic transducer with metal-piezoceramic laminated circular plate were simulated. The Vibrational modes of metal-piezoceramic laminated circular plates were calculated by using the finite element method. After meshing the inside closed boundary of the acoustic transducer, the pressure gradients and the isotaric lines were calculated for the various frequencies. It has been observed that the characteristics of the sound pressure calculated for the various frequencies. Also, the directivity patterns and the sound pressure radiated from the acoustic transducer were calculated by 2-dimensional analysis.

  • PDF

A Comparison on the Form in Women's Hanbok between the Later Chosun Dynasty and Modern Times- Applying Delong's Dividing System for Apparel Body Construct (조선 후기와 현대의 여자한복 형태 비교 -Delong의 복식형태 분류체계를 적용하여)

  • 김순영;남윤자
    • Journal of the Korean Society of Costume
    • /
    • v.52 no.5
    • /
    • pp.61-77
    • /
    • 2002
  • The purpose of this study is to investigate difference and likeness on the form in women's Hanbok between the later Chosun Dynasty and modern times based on Belong's observing system for 'Apparel-Body Construct'. Belong's framework is composed 5 pairs of contrast word -'Closed or Open', 'Whole or Par', 'Planar Separation or Planar integration'. 'Flat or Rounded', and 'Determinate or Indeterminate'. Major findings of this study are as follows. First, the form of women's Hanbok in later Chosun Dynasty is 'Variably Closed', 'Part' and 'Rounded', whereas that in modern is 'Open', 'Whole' and 'Flat' Women's Hanbok of modern is lesser convex, and more open than that of later Chosun Dynasty according to increasing use of transparent textiles. Moreover, in comparison with old style, that of modern has the tendency of perceiving primarily whole feature by organic linkage of parts. Because of loose fit of Jeogori and rigid DongJong etc, characteristic of 'Plat' strengthened in modern Hanbok. Secondly, women's Hanbok in the later Chosun Dynasty and modern has common properties of 'Planar Seperation' and 'Determinate'. Women's Hanbok belongs to 'Planar Seperation', because the effect cognized to figure and ground. can be found between small parts and whole of Jegori, or can be found between the head and face. Jeuori and waist band, and Chima and under ware. Further more. it can be classified into 'Determinate'. because it use textiles which have no pattern un it or which show a subtle surface effect by texture changing.

Results of the Closed Treatment of Displaced Middle-Third Fractures of The Clavicle (전위된 쇄골간부 골절에서 보존적 치료의 결과)

  • Lee Kwang-Won;Song Dae-Hwa;Ong Sang-Suk;You Soo-Guen;Choy Won-Sik
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.1
    • /
    • pp.83-92
    • /
    • 1998
  • Fractures of the clavicles are extremely common, accounting for 5 to 10% of all injuries in the adult skeletal trauma. Despite this, nonunions and symptomatic malunions after clavicular fracture are uncommon. When these complications occur, however, they may be associated with 11 pattern of disability that includes not only pain but also impairment of upper extremity function. The purpose of this study was to clarify the outcome of clavicular fractures treated by conservatively, and emphasize treatment and factors that possibly predispose a clavicular fracture to poor function or nonunion. We evaluated 9] consecutive fractures of the middle-third of the clavicle in adults which had been treated conservatively. There were 59 males and 33 females ranging in age from 17 to 80 years (average 36.8 years). Nine of the 91 fractures (10%) had developed nonunion, and 4 fractures (4.4%) reported unsatisfactory results. No patients had significant impairment of range of motion or strength as a result of the injury. We found that initial shortening at the fracture of≥20mm(6 cases) had a highly significantly association with nonunion(P<0.0001). Final shortening of 20mm or more (4 cases) was associated with an unsatisfactory result, but not with nonunion(P<0.0001). Our results have led us to recommend the open reduction and internal fixation of severely displaced fractures of the middle third of the clavicle in adults patients.

  • PDF

Comparison of Balance Ability on the Heel Height and the Habituation to the High Heel (신발 굽 높이와 착용 습관화에 따른 균형 능력 비교)

  • Lee, H.J.;Lee, S.J.;Tae, K.S.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.2
    • /
    • pp.106-113
    • /
    • 2010
  • The aim of this study was to evaluate effects of the balance ability on the heel height (flat, low heel[3cm], and high heel[7cm]) and high heeled habituation (group A is used to a low heeled shoes (<7cm) and group B is used to a high heeled shoes (${\geq}7cm$). Thirty-five subjects participated in this study. In this study, the static balance with opened eyes and closed eyes and dynamic balance were measured. Also functional reach test was tested. The results found that the static balance ability was the best in a 7cm heeled shoes with open eyes and closed eyes, but there was not significant difference between group A and Group B. Dynamic balance ability with walking velocity and cadence were significant difference between Group A and B. In the walking velocity, a flat was the fastest, followed by 7cm heel and 3cm heel with Group A while 3cm and 7cm, then a flat with Group B. Also Cadence pattern was similar. Functional balance ability was the highest with a flat, but it was not difference significantly between Group A and B. Therefore, this study demonstrated that the habituation to the high heel altered gait velocity and cadence of dynamic balance ability.

An Experimental Study on the Cause of Signal Inhomogeneity for Magnetic Resonance Angiography Using Phantom Model of Anterior Communicating(A-com) Artery (전교통동맥 모형을 이용한 자기공명혈관촬영술의 신호 불균일에 관한 실험적 연구)

  • Yoo, Beong-Gyu;Chung, Tae-Sub
    • Journal of radiological science and technology
    • /
    • v.25 no.1
    • /
    • pp.55-62
    • /
    • 2002
  • Aneurysm-mimicking findings were frequently visualized due to hemodynamical causes of dephasing effects around area of A-com artery during magnetic resonance angiography(MRA) and these kind of phenomena have not been clearly known yet. We investigated the hemodynamical patterns of dephasing effect around area of the A-com artery that might be a cause of false intracranial aneurysms on MRA. For experimental study, We used hand-made silicon phantoms of the asymmetric A-com artery as like a bifurcation configuration. In a closed circulatory system with UHDC computer driven cardiac pump system. MRA and fast digital subfraction angiography(DSA) involved the use of these phantoms. Flow patterns were evaluated with axial and coronal imaging of MRA(2D-TOF, 3D-TOF) and DSA of Phantoms constructed from an automated closed-type circulatory system filled with glycerol solution [circulation fluid(glycerol:water = 1:1.4)]. These findings were then compared with those obtained from computational fluid dynamic(CFD) for inter-experimental correlation study. Imaging findings of MRA, DSA and CFD on inflow zone according to the following: a) MRA demonstrated high signal intensity zone as inflow zone on silicon phantom; b) Patterns of DSA were well matched with MRA on trajectory of inflow zone; and c) CFD were well matched with MRA on the pattern of main flow. Imaging findings of MRA. DSA and CFD on turbulent flow zone according to the following: a) MRA demonstrated hyposignal intensity zone at shoulder and axillar zone of main inflow; b) DSA delineated prominent vortex flow at the same area. The hemodynamical causes of signal defect, which could Induce the false aneurysm on MRA, turned out to be dephasing effects at axilla area of bifurcation from turbulent flow as the results of MRA, DSA and CFD.

  • PDF

A Visual Study on Nucleate Boiling Phenomena in a Closed Two-Phase Thermosyphon (밀폐형 2상 열사이폰내의 비등현상에 관한 가시화 연구)

  • 강환국;오광헌;김철주;박이동;황영규
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.185-198
    • /
    • 1995
  • This is an experimental study conducted to visualize the nucleate boiling phenomena and flow regimes occurring inside the liquid pool in a closed two-phase thermosyphon. To meet this purpose, an annular-type thermosyphon was designed and manufactured using a glass tube and a stainless steel tube, being assembled axisymmetrically. The heat to be supplied to the working fluid is generated within a very thin layer of stainless steel tube wall by applying a high frequency electromagnetic field through the induction coil, axisymmetrically set around the evaporator zone. Some important results were as follows ; 1) Considering the structural complexity of the tested thermosyphon, it showed good performance for the range of heat flux 2< q" <25kW/$m^2$ and saturation vapor pressure, 0.1<Pv<1.1bar 2) different type of nucleating boiling regimes were observed as described below, -Pulse boiling regime : Flow pattern changed cyclically with time during 1 cycle of pulse boiling process. The onset of Nucleation was followed by expulsive growing of vapor bubble, resulting in the so called blow-up phenomenon, massive expulsion of large amount of liquid around the bubble. -Transient : Some spherical vapor bobbles were observed growing out from 2~3 nucleating sites, that was dispersed at the lower part of the heated tube wall in the liquid pool. But the rest upper region above the nucleating sites were filled with churns or bubbles of vapor. -Continuous nucleate boiling regime : The whole zone of evaporator was filled with lots of spherical vapor bubbles, and the bubbles showed tendency to decrease in diameter as the heat flux increased.ased.

  • PDF

Long-term Evaluation of Conervative Treatment for the Patients with TMJ Closed Lock (악관절 폐구성 과두걸림의 보존적 치료에 대한 장기적 평가)

  • Mi-Suk Seo;Jae-Kap Choi
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.1
    • /
    • pp.93-103
    • /
    • 1994
  • In order to evaluate thelong-term results of conservative treatment on TMJ closed lock, a follow-up study of thirst-two patients was performed 2 to 7 year after treatment. Evaluating method included the questionnaire, clinical examination, transcranial radiograph and mandibular kinesiography. The results were as follows : Seventy-eight percents of patients reported that symptoms were reduced completely or considerably. Recurrent headache was improved after treatment (72 percents of success rate). There was a significant decrease in VAS after treatment and at follow-up comparing with that of before treatment(p<0.01). Most common variable of Helkimo's clinical dysfunction index at follow-up was impared TMJ function. There was a significant decrease in Fricton's craniomandibular index and dysfunction index(p<0.01) Mean interincisal distance was increased by 14.07mm after treatment and was also increased at follow-up by 2.80mm comparing with that of after treatment(p<0.01). Before treatment, condylar translation measurements of affected and non-affected sides on the transcranial radiograph were 4.89±3.20mm and 9.09±3.73mm respectively and at follow- up examination, those were 14.98±4.77 and 17.05±4.35mm respectively. At follow-up, condylar translation were increased significantly comparing with those of before treatment(p<0.01). In 93.1% of patients, the condylar position of affected side at maximum mouth opening was behind the articular eminence before treatment but the percentage was decreased to 13.8% at follow-up(p<0.01). The pattern and range of mandibular movements at follow-up examination were similar to the typical normal movements. And in 16 cases showing lateral deviation of opening path, the deviation was directed to the affected and non-affected sides with the same frequency.

  • PDF