• Title/Summary/Keyword: Closed cycle

Search Result 231, Processing Time 0.024 seconds

Measurement Methods of Latent Heat for PCM with Low Melting Temperature in Closed Tube (밀폐튜브 내 저온 PCM의 잠열측정법)

  • 류경용;박창현;백종현;홍회기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.7
    • /
    • pp.604-610
    • /
    • 2003
  • Cycle test for developed phase change material (PCM) is necessary in order to analyze the variation of latent heat, which decreases with time by deterioration. 7-history method and measurement using heat flux meter are appropriate for the cycle test in a tube filled with PCM because they do not need an extraction of sample in measuring the heat of fusion. In the present study, these methods were applied to a PCM having a melting point below a room temperature, different from the past studies for PCMs melting above a room temperature. As a result of experiment using pure water as specimen, we can obtain reason-able values for heat of fusion by both methods.

A Research on the Jeonuigam medical cadet in the late 19th century (19세기 후반 전의감(典醫監) 의학생도(醫學生徒)에 대한 고찰 - 『전함생도안(前銜生徒案)』을 중심으로 -)

  • Park, Hun-Pyeng
    • The Journal of Korean Medical History
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Jeonuigam(典醫監) is one of the Big Three of medical government office through the Joseon dynasty era. But Jeonuigam literature is extremely rare. This paper is to analyze 362 cadets of "Jeonham-saengdoan(前銜生徒案)" by writer of Jeonuigam origin. Jeonuigam filled cadet on a three-year cycle because the national examination for medical officials is conducted on same cycle. Most cadets came from a few meritorious family of medical career officials. Ratio of ten major family stand at 34.91 percent. 373 of the 392 cadets are confirmed as family member of medical bureaucrat. They have a very closed society. Wancheon(完薦) and cadet system strengthen the monopholy power of a few family. The analysis of study confirmed that in the 19th century Joseon(朝鮮) dynasty had monopolized the medical technicians.

Current Status of Liquid-Free Superconducting System Develo (액체를 사용하지 않는 초전도시스템의 개발 동향)

  • 장호명
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.1-6
    • /
    • 1999
  • The recent progress in the new cooling technology for superconducting systems without liquid cryogens is briefly presented. In these conduction-cooled systems, the super-conducting magnets are cooled by a direct contact with closed-cycle cryocoolers and only electricity is supplied to maintain the cryogenic temperatures. It is reported that at least 20 conduction-cooled (low Tc or high Tc) super- conducting systems have been constructed, tested, or commercially used worldwide. Some of the significant design issues are discussed in comparison with the conventional liquid-helium cooled systems.

  • PDF

Design Practice of a Vehicle Mounted Platform Servo Control System Slaved to the Independently Controlled Tracking System

  • 안태영;강태하;손승걸;조성훈;최영호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.209-214
    • /
    • 1992
  • This paper presents a one cycle R&D project regarding the large inertia platform servo control system. The steps followed the rather orthodox procedure. A serial double rate-loop was closed with a position loop, and acceleration velocity anticipatory compensations were designed in the forward path. Some appropriate compensation devices were utilized for the signal processing as well as for the better control quality. Simulations and experimental tests were repeated, and satisfactory performances were observed. However, frequency domain uncertainties inherent to the large structures still remain as an expertise supported subject.

저층방류 해석을 위한 수치모의

  • Kim, Chul;Kim, Dae-Geun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.02a
    • /
    • pp.93-111
    • /
    • 2004
  • 온수 방류방식의 분류는 냉각수 공급방식별로 냉각수 통과방식(once-through cooling system)과 냉각수 재순환방식(closed-cycle cooling: system)으로 구분된다. 배출구조별 분류는 수표면방류 방식(surface discharge type)과 수중방류 방식(submerged discharge type)으로 구분된다. 국내 외의 연구결과 수중 방류방식이 희석효과가 좋아 환경에 미치는 영향이 작은 것으로 평가되고 있으나, 국내의 발전소에서는 대부분 수표면방류 방식을 채택하고 있다. (중략)

  • PDF

The Design Method and Error Analysis of Machine Electronic Weighing Burden System controlled by a Computer Automatically

  • Zhang, Zhengou;Lin, Shanling
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.768-778
    • /
    • 1993
  • The system is designed for the production and processing of feed, fertilizer, sugar , and grain. It can be used to weigh and transport automatically their pellet, power or nonstickness materials. In this system, we use discontinuous totalising automatic weighing instruments to weigh materials. It is a closed-cycle control system controlled by industrial controlling computer STD bus. The system used for processing grain and feed can improve the quality of products , carry out scientific management, increase productivity and decrease the intensity of labour

  • PDF

Development of a diaphragm type actuator (다이어프램형 방식의 파일럿 액추에이터 개발)

  • Lee, Joongyoup;Jeong, Daeseong;Han, Sangyeop
    • Aerospace Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.160-166
    • /
    • 2014
  • The shutoff valve of a Liquid Rocket Engines (LRE) controls the flow of propellant between turbo-pump and combustion devices of LRE using pilot pressure and spring force. The shutoff valve is closed when the pilot pressure is removed from the diaphragm type actuator. During designing process of life cycle is when should be analyzed according to the characteristics of forces with respect to the opening and closing of diaphragm actuator. A valve has been designed to adjust the control pressure which is required to open a poppet and to determine the working fluid pressure at which a valve starts to close. During flow capacity test under room temperature as a part of life cycle tests, the leakage in diaphragm was occurred due to the leakage of sheet welding sections. The operating cycle of the diaphragm type actuator is about 61 times with 22 MPa of pilot pressure.

A Study on the Theoretical Analysis and Optimal Design Conditions for the $\alpha$ type Stirling Engine ($\alpha$형 스터링 엔진의 최적 설계 조건)

  • 강문규;이택희;유재환
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.142-154
    • /
    • 1998
  • A stirling engine is a mechanism used to convert heat to power and operates on a closed regenerative thermodynamic cycle with compression and expansion of the working fluid at different temperature. The performance of a stilting cycle machine is a function of six independent parameters, namely; (1) speed N(r.p.m), (2) pressure of the working fluid p(Pa), (3) ratio of the temperature in the compression and expansion space ${\tau}(=T_C/T_E)$ , (4) ratio of the swept volumes in these two spaces K, (5) phase angle $\alpha$ and (6) dead volume ratio X. This paper describes the procedure and presents the results of computations carried out to establish the optimum combinations of these six parameters for maximum engine output for the machine acting as a prime mover, over a combined temperature range from $300^{\circ}K$ to $1000^{\circ}K$ and dead volume ratio X ranging from 0.1 to 2.0. The output of a stilting cycle machine can be expressed in terms of nondimensional power in several different ways. Four methods were studied in detail, the parameters optimized and design charts and engine power charts prepared. The results of this paper may be useful as a guide to the likely effects on the performance of some of the important design parameters and regenerator design.

  • PDF

A Study of Comparative Economic Evaluation for the System of Ground Source Heat Pump and District Heating and Cooling:Focusing on the Analysis of Operation Case (지열히트펌프와 지역냉난방 시스템의 운영사례를 중심으로 경제성 비교분석 연구)

  • Lee, Key Chang;Hong, Jun Hee;Kong, Hyoung Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.3
    • /
    • pp.103-109
    • /
    • 2016
  • The purpose of this study is to perform comparative economic evaluation for the systems of ground source heat pump (GSHP) and district heating and cooling (DHC) by focusing on the analysis of operation case of GSHP. The adapted research object is a public office building located in Seoul. The capacity of ground source pump is about 3,900 kW. Ground heat exchanger is closed loop type. The analysis period for life cycle cost is 30 years. Economic evaluation is assessed from the viewpoints of the following four parts: initial cost, energy cost, maintenance and replacement cost, and environment cost. The total life cycle cost of GSHP is approximately 8,447 million won. The cost of the DHC System is approximately 3,793 million won. The cost of the DHC is approximately 46% lower than GSHP system under the condition of current rate for GSHP and DHC.

Catalytic Membrane Reactor for Dehydrogenation of Water Via gas-Shift: A Review of the Activities for the Fusion Reactor Fuel Cycle

  • Tosti, Silvano;Rizzello, Claudio;Castelli, Stefano;Violante, Vittorio
    • Korean Membrane Journal
    • /
    • v.1 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • Pd-ceramic composite membranes and catalytic membrane reactors(CMR) have been studied for hydrogen and its isotopes (deuterium and tritium) purification and recovery in the fusion reactor fuel cycle. Particularly a closed-loop process has been studied for recovering tritium from tritiated water by means of a CMR in which the water gas shift reaction takes place. The development of the techniques for coating micro-porous ceramic tubes with Pd and Pd/Ag thin layers is described : P composite membranes have been produced by electroless deposition (Pd/Ag film of 10-20 $\mu$m) and rolling of thin metal sheets (Pd and Pd/Ag membranes of 50-70 $\mu$m). Experimental results of the electroless membranes have shown a not complete hydrogen selectivity because of the presence of some defects(micro-holes) in the metallic thin layer. Conversely the rolled thin Pd and Pd/ag membranes have separated hydrogen from the other gases with a complete selectivity giving rise to a slightly larger (about a factor 1.7) mass transfer resistance with respect to the electroless membranes. Experimental tests have confirmed the good performances of the rolled membranes in terms of chemical stability over several weeks of operation. Therefore these rolled membranes and CMR are adequate for applications in the fusion reactor fuel cycle as well as in the industrial processes where high pure hydrogen is required (i.e. hydrocarbon reforming for fuel cell)

  • PDF