• Title/Summary/Keyword: Closed circuit

Search Result 340, Processing Time 0.035 seconds

A Strategy for Balanced Power Regulation of Energy Storage Systems in a Distribution System during Closed-Loop Operation

  • Han, Yoon-Tak;Oh, Joon-Seok;Cha, Jae-Hun;An, Jae-Yun;Hyun, Seung-Yoon;Lee, Jong-Kwan;Seo, In-Yong;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2208-2218
    • /
    • 2017
  • To resolve overload in a distribution system, a distribution system operator (DSO) often performs a load transfer using normally open tie points and switches in the distribution line. During this process, the distribution system is momentarily operated in closed-loop operation. A closed-loop current in the distribution system can cause a power failure due to excess breaking current in the circuit breakers and reclosers. Therefore, it is necessary to calculate the closed-loop current exactly. However, if there are a large number of distributed generation (DG) systems in the distribution system, such as energy storage systems (ESS), they might obstruct the closed-loop operation based on bidirectional power flow. For quick and precise operation of a closed-loop system, the ESS has to regulate the power generation while satisfying closed-loop operation in the worst cases. We propose a strategy for balanced power regulation of an ESS. Simulations were carried out using PSCAD/EMTDC, and the results were compared with calculation results.

Circuit Parameters and Characteristic Analysis of Condenser Run Single Phase Induction Motor by Combine Equivalent Circuit with Numerical Method (등가회로법과 수치해석의 결합에 의한 콘덴서 구동형 단상 유도전동기의 회로정수 산정 및 특성해석)

  • Kang, Gyu-Hong;Ha, Kyung-Ho;Hong, Jung-Pyo;Kim, Gyu-Tak;Jeong, Seung-Kyu
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.11
    • /
    • pp.720-728
    • /
    • 2000
  • This paper describes the calculation of the equivalent circuit parameters and the characteristic analysis of a capacitor-run type single-phase induction motor by means of the finite element method in coupled with the conventional equivalent circuit model. The circuit parameters of the stator are calculated form the lumped parameter and the slot leakage reactance of the rotor with the closed slot can be obtained by the use of slot pitch boundary condition. From the analysis result this combined equivalent circuit and finite element method which is used slot pitch boundary condition is compared with the experimental results, the validity of the method is proved.

  • PDF

Particle-Size Distribution Dependent upon Crushing Mechanism and Crushing Circuit (파쇄 메카니즘과 파쇄회로에 따른 입도분포)

  • Choi, Do-Young;Kim, Wan-Tae;Kim, Sang-Bae
    • Journal of the Mineralogical Society of Korea
    • /
    • v.23 no.4
    • /
    • pp.297-303
    • /
    • 2010
  • We report the particle-size distribution and comminution charactersitics of dolomite depending upon crushing equipment (hammer crusher and roll crusher) and crushing circuit (open and closed). The quantity of fine particles (< 100 mesh) produced by hammer crusher was 34 wt.% which is about three times that by roll crusher. The quantity of 14~25 mesh size fraction by roll crusher was 20 wt.% higher than that produced by hammer crusher. 80 wt.% of the crushing products by hammer crushing was under 35 mesh in size, while the particles produced by roll crushing were relatively coarse. The particle size of both the hammer and roll crushers decreased by employing closed crusing circuit in comparison to open circuit. Products of required particle-size were obtained effectively depending on appropriate crushing equipment and crushing circuit.

Closed loop type MCV(Main Control Valve) for Hydraulic Excavator (유압 굴삭기용 폐루프 타입 MCV(Main Control Valve))

  • Lim T.H.;Lee H.S.;Yang S.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.864-870
    • /
    • 2005
  • Hydraulic excavators have been popular devices in construction field because of its multi-workings and economic efficiency. The mathematical models of excavators have many nonlinearities because of nonlinear opening characteristics and dead zone of main control valve, oil temperature variation, etc. The objective of this paper is to develop a simulator for hydraulic excavator using AMESim. Components and whole circuit are expressed graphically. Parameters and nonlinear characteristics are inputted in text style. From the simulation results, fixed spring stiffness of MCV can't satisfy accuracy of spool displacement under whole P-Q diagrams. Closed loop type MCV containing proportional gain is proposed in this paper that can reduce displacement error. The ability of closed loop MCV is verified through comparing with normal type MCV using AMESim simulator. The simulator can be used to forecastexcavator behavior when new components, new mechanical attachments, hydraulic circuit changes, and new control algorithm are applied. The simulator could be a kind of development platform for various new excavators.

  • PDF

Characteristics of Closed Circuit Cooling Tower with Variation of Tube Diameter (멀티패스 밀폐식 냉각탑의 관경변화 특성)

  • Shim, Gyu-Jin;Lee, Ho-Saeng;Kim, Eun-Pil;Yoon, Jung-In;Kwon, O-Ick
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.531-536
    • /
    • 2008
  • This paper presents experimental result of characteristics about Closed circuit Cooling Tower having a rated 2RT. The experimental apparatus has been set-up with a conventional type system. The test section is heat exchangers of cooling tower that consist of different vertical tubes, 15.88mm with 10 rows and columns and 19.05 mm with 8 rows and 12 columns. The main results were summarized as follows : The values of heat and mass transfer coefficients of cooling tower operating with two paths are higher than these with one path. Cooling capacity per unit volume using 15.88mm tubes are higher than 19.05mm tubes.

  • PDF

An Electromechanical ${\sum}{\triangle}$ Modulator for MEMS Gyroscope

  • Chang, Byung-Su;Sung, Woon-Tahk;Lee, Jang-Gyu;Kang, Tea-Sam
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1701-1705
    • /
    • 2004
  • This paper presents a design and analysis of electromechanical sigma-delta modulator for MEMS gyroscope, which enables us to control the proof mass and to obtain an exact digital output without additional A/D conversion. The system structure and the circuit realization of the sigma-delta modulation are simpler than those of the analog sensing and feedback circuit. Based on the electrical sigma-delta modulator theory, a compensator is designed to improve the closed loop resolution of the sensor. With the designed compensator, we could obtain enhanced closed-loop performances of the gyroscope such as larger bandwidth, lower noise, and digital output comparing with the results of analog open-loop system.

  • PDF

Analysis of Transmission Power System with Superconducting Fault Current Limiter for Reducing a Fault Current (초전도 한류기 적용을 통한 모의 송전계통의 고장 전류 저감 분석)

  • Kim, Myong-Hyon;Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul;Choo, Dong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.718-719
    • /
    • 2011
  • Lately, the demand for electrical power has been significantly increased. As a result a power transmission system has been improved. On the other hand fault current increased more than past. Superconducting fault current limiter (SFCL) is one of the solutions to limit fault current. However, SFCL's research has not advanced in a power transmission system fully. Therefore, we studied effect of SFCL in a power transmission system. The power distribution system is open-loop circuit, but a power transmission system is closed-loop system. Consequently, Fault current in a power transmission system is larger than fault current in a power distribution system. we exerimented a simple closed-loop power transmission system circuit.

  • PDF

Development of a Fruit Harvesting Robot(II) -Determination of Fruit Location by a Closed-Circuit TV Camera- (과실수확(果實收穫) 로봇에 관한 연구(硏究)(II) -폐쇄회로(閉鎖回路) TV 카메라에 의한 과실(果實)의 위치검출(位置檢出)-)

  • Ryu, K.H.;Noh, S.H.;Kim, Y.H.
    • Journal of Biosystems Engineering
    • /
    • v.14 no.2
    • /
    • pp.104-114
    • /
    • 1989
  • The most important subject in developing agricultural robots for fruit harvesting is to detect accurately the location of a fruit about the given coordinate system. This study was carried out to develop an image processing algorithm which enables finding out the three dimensional locations of a fruit. The digital image processing device consisted of an optosensor (Closed-circuit TV camera), image processing interface board (Digitizer) and microcomputer (IBM PC/AT). A stereo-image processing method using the two cameras attached to the manipulator was evaluated through experiment with apples. The accuracy and quickness of detecting the location of apples by this method was not satisfactory. The maximum errors of the detected locations by the stereo-image processing method in x-, Y-, and z- directions were 3, 4 and 4 cm, respectively. The maximum time required to get the rectangular coordinate data of a fruit was about 2 minutes.

  • PDF

Detection of Dangerous Situations using Deep Learning Model with Relational Inference

  • Jang, Sein;Battulga, Lkhagvadorj;Nasridinov, Aziz
    • Journal of Multimedia Information System
    • /
    • v.7 no.3
    • /
    • pp.205-214
    • /
    • 2020
  • Crime has become one of the major problems in modern society. Even though visual surveillances through closed-circuit television (CCTV) is extensively used for solving crime, the number of crimes has not decreased. This is because there is insufficient workforce for performing 24-hour surveillance. In addition, CCTV surveillance by humans is not efficient for detecting dangerous situations owing to accuracy issues. In this paper, we propose the autonomous detection of dangerous situations in CCTV scenes using a deep learning model with relational inference. The main feature of the proposed method is that it can simultaneously perform object detection and relational inference to determine the danger of the situations captured by CCTV. This enables us to efficiently classify dangerous situations by inferring the relationship between detected objects (i.e., distance and position). Experimental results demonstrate that the proposed method outperforms existing methods in terms of the accuracy of image classification and the false alarm rate even when object detection accuracy is low.

A Comparison of Thoracic Gas Volume measured by Body Plethysmographic Method and Functional Residual Capacity measured by Closed Circuit Method (Body Plethysmograph 방법과 폐쇄식회로법으로 측정한 기능적잔기량의 비교)

  • Chung, Chee-Kyung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.3 no.1
    • /
    • pp.17-22
    • /
    • 1970
  • By using Siregnost FD 91 body plethysmograph, we measured thoracic gas volume (TGVe) at end of expiration in 19 healthy subjects aged 20-43 years in order to compare with functional residual capacity (FRC) measured by closed circuit method. The results obtained were as follows 1. Mean values of TGVe and FRC were $3.395{\pm}0.5851{\ell},\;and\;3.393{\pm}0.618{\ell}$, respectively. 2. A advantage of the body phethysmographic method for measuring thoracic gas volume was that it were rapid, safe, and easy to perform, requires no gas sample for chemical analysis, and measured TGVe several times.