• Title/Summary/Keyword: Closed Thermosyphon

Search Result 39, Processing Time 0.019 seconds

Thermal Energy Storage in Phase Change Material - by Means of Finned Thermosyphon - (상변화 물질을 이용한 에너지의 저장에 관한 연구 - 핀이 부착된 열싸이폰의 이용에 관하여 -)

  • Kim, Kwon-Jin;Yoo, Jai-Suk;Kim, Ki-Hyun
    • Solar Energy
    • /
    • v.11 no.1
    • /
    • pp.69-77
    • /
    • 1991
  • A two-phase closed thermosyphon with circular fins was used as the heat transfer device for storing the thermal energy in paraffin wax. Experiments were carried out for 4, 6 and 8 fins and for various initial temperatures of the wax and power inputs. Heat transfer characteristics along the heat flow path were investigated as well as the overall performance of the system. Some of the important results are as follows:(1) The thermosyphon heat transfer coefficient and the overall heat transfer coefficient increased with the number of fins, whereas the heat transfer coefficient between the fin and the wax decreased; (2) Facilitation of heat transfer by the fins seemed to alleviate the dry-out phenomenon that had been reported to occur in case of bare thermosyphon; and (3) The horizontal fins had adverse effect of subduing a full scale convection in the wax, and the increase of the number of fins delayed the onset of local convection between the fins.

  • PDF

A Closed Counter-Current Two-Phase Thermosyphon Loop of a Cold Neutron Source in HANARO Research Reactor (하나로 원자로에 설치될 대향 이상 열사이펀 루프에 관한 실험)

  • Hwang, Kwon-Sang;Cho, Man-Soon;Sung, Hyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.8
    • /
    • pp.1038-1045
    • /
    • 2000
  • An experimental study was carried out to delineate the flow characteristics in a closed countescurrent two-phase thermo syphon with concentric tubes. This is to be installed in the HANARO research reactor as a part of a Cold Neutron Source(CNS). In the present investigation, experiments ata room temperature with Freon-II3 as a moderator were performed. Results show that, based on the magnitude of pressure fluctuation, the flow regimes could be divided into 4 distinct ones in the ($V_f,\;Q_i$) plane, where $V_f$ represents the volume of the charged liquid and $Q_i$ the heat load: a stable flow regime, an oscillatory flow regime, a restablized flow regime and a dryout flow regime. For $V_f$>2.5l, the flow is stable at low $Q_i$. However, as $Q_i$ increases, the flow becomes oscillatory and finally restablizes As $V_f$ increases, the oscillation amplitude decreases, reaching to the restablized flow region at low $Q_i$, and the liquid level in the moderator cell remains high. In the oscillatory flow regimes, for a fixed VI; the oscillating period of time varies with $Q_i$, having a minimum value at a certain value of $Q_i$. The heat load, where the oscillating period of time is minimum, decreases as $V_f$ increases.

A Study on the Performance of the Boiling and Condensation Heat Transfer of Vertical Closed Two-Phase Thermosyphons with Low Integral-Fins (관 외벽에 낮은 핀을 가진 수직 열사이폰의 비등 및 응축열전달 성능에 관한 연구)

  • Cho, Dong-Hyun
    • Solar Energy
    • /
    • v.19 no.1
    • /
    • pp.9-17
    • /
    • 1999
  • An Experimental study on the boiling and condensation heat transfer performance of thermosyphons with low intergral-fins was performed to investigate its heat transfer characteristics. A plain thermo syphon having the same inner and outer diameter as the finned thermosyphons was also tested for comparison. Water and CFC-30 was used as working fluids. The experimental results have been assessed and compared with same existing theories. Good agreement with the theories of Imura and Nusselt was obtained. The vertical closed-type thermosyphons with low integral-fins gave significant increases in the overall heat transfer coefficient compared to plain thermosyphon. In addition, the overall heat transfer coefficients and the operating characteristics was obtained as a function vof operating temperature for the practical applications. Also, the closed two-phase thermosyphons with low integral-fins would be highly recommended to achieve some inexpensive and compact heat exchangers in the range of low temperatures.

  • PDF

A Study on Operating Characteristics of the Two-Phase Closed Thermosyphon with a Binary Mixture (2성분 혼합물을 사용한 2상 밀폐 열싸이폰의 작동특성에 관한 연구)

  • 곽희열;김종보
    • Journal of Energy Engineering
    • /
    • v.4 no.1
    • /
    • pp.95-102
    • /
    • 1995
  • 작동유체로서 비등점이 서로 다른 2종류, 즉 2성분 혼합물을 사용한 2상 밀폐 열싸이폰은 단일성분의 열싸이폰 보다 공학적으로 우수한 성능을 갖는다. 따라서 상 분리 현상이 나타나지 않은 안정적인 혼합물인 물/에탄올의 혼합물을 작동유체로 사용한 열싸이폰의 작동특성이 실험적으로 수행되었다. 실험에서는 시동성, 정상상태 작동, 경사시 작동특성 및 열전달 한계(Dry-out) 등에 관한 2성분 열싸이폰의 작동특성에 관해서 고찰되었다.

  • PDF

Performance of a Latent Heat Storage System Using Two-Phase Closed Thermosyphon(II) - The Case of Constant Temperature Heating Fluid (열싸이폰을 이용한 잠열축열시스템의 성능실험(II) - 일정한 온도의 가열유체를 사용한 경우 -)

  • Kim, Tae-Il;Kim, Ki-Hyun
    • Solar Energy
    • /
    • v.12 no.3
    • /
    • pp.37-46
    • /
    • 1992
  • An experimental study was carried out to investigate the performance of a latent heat storage system using paraffin wax as the phase change material. A thermosyphon was employed to transfer heat from the hot ethylene glycol flowing across the evaporator section of the thermosyphon into the wax. In order to increase the effective thermal conductivity of wax, layers of copper wire mesh were immersed in the wax. Experiments were run for volume ratios of 2%, 3%, and 4%, varying mass flow rate of ethylene glycol in each case. Some of the important results are as follows : (1) The wire mesh enhanced the conductive hea transfer and thus, helped even out the temperature distribution in the wax : (2) The increase of the number of layers of wire mesh increased the conduction. However, it also resulted in increasing the resistance to the convective motion of liquefied wax : and (3) There is an optimal number of layers of wire mesh, maximizing the performance of the storage system, which occurred at a volume ratio of $3{\sim}4%$ in the present study.

  • PDF

Performance Characteristics of a Loop Thermosyphon for Heat Source Cooling (열원 냉각용 루프 써모사이폰의 작동 특성)

  • Choi, Du-Sung;Song, Tae-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1475-1483
    • /
    • 2004
  • Loop thermosyphon(LTS) has many good characteristics such as low thermal resistance, no power consumption, noiseless operation and small size. To investigate the overall performance of LTS, we have performed various experiments varying three parameters: input power of the heater, working fluid(water, ethanol, FC3283) and filling ratio of the working fluid. At a combination of these parameters, temperature measurements are made at many locations of the LTS. The temperature difference between the evaporator and the condenser is used to obtain the thermal resistance. In addition, flow visualization using a high speed camera is carried out. The thermal resistance is not constant. It is lower at higher input power, which is one of the distinct merits of LTS. Flow instabilities are frequently observed when changing the working fluid, the input power and the filling ratio. The results show that the LTS can be readily put into practical use. Future practical application in electronic cooling is recommended.

A Visual on Study on Nucleate Boiling Phenomena in a Closed Two-Phase Thermosyphon (밀폐형 2상 열사이폰내의 비등현상에 관한 가시화 연구)

  • 김철주;강환국;오광헌
    • Journal of Energy Engineering
    • /
    • v.4 no.2
    • /
    • pp.261-269
    • /
    • 1995
  • 본 연구에서는 밀폐형 2상 열사이폰의 액체 Pool에서 발생하는 핵비등현상과 유동영역에 대해 가시화 방법으로 연구하였다. 실험용 열사이폰은 스텐레스와 유리관을 이용하여 제작하였으며, 열공급은 증발부 주위에 설치된 유도 가열용 코일에 고주파를 가함으로써 스텐레스 외면에 발열이 일어나도록 하였다. 이에 따른 결과는 다음과 같다. 실험용 열사이폰은 고주파 가열등 열사이폰의 작동성능을 저해하는 여러 요인들이 포함되어 있었으나, 실험결과 이러한 문제는 실험 내용에 영향을 미칠만큼 크게 나타나지 않았다. 열속과 상당압력의 범위는 각각2$m^2$, 0.1

  • PDF

Experimental Validation of Two Simulation Models for Two-Phase Loop Thermosyphons

  • Rhi, Seok-Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.4
    • /
    • pp.159-169
    • /
    • 2003
  • Five two-phase closed loop thermosyphons (TLTs) specially designed and constructed for the present study are one small scale loop, two medium scale loops (MSLI and MSLII) and two large scale loops (LSLI and LSLII). Two simulation models based on thermal resistance network, lumped and sectorial, are presented. In the Lumped model, the evaporator section is dealt as one lumped boiling section. Whereas, in the Sectorial model, all possible phenomena which would occur in the evaporator section due to the two-phase boiling process are considered in detail. Flow regimes, the flow transitions between flow regimes and other two-phase parameters involved in two-phase flows are carefully analyzed. In the present study, the results of two different simulation models are compared with experimental results. The comparisons showed that the simulation results by the Lumped model and by the Sectorial model did not show any partiality for the model used for the simulation. The simulation results according to the correlations show the various results in the large different range.

Study on Performance Evaluation of Oscillating Heat Pipe Heat Exchanger for Low Temperature Waste Heat Recovery

  • Bui, Ngoc-Hung;Kim, Ju-Won;Jang, In-Seung;Kang, Jeong-Kil;Kim, Jong-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.2
    • /
    • pp.73-81
    • /
    • 2003
  • The performance of heat exchanger using oscillating heat pipe (OHP) for low temperature waste heat recovery was evaluated. OHP used in this study was made from low finned copper tubes connected by many turns to become the closed loop of serpentine structure. The OHP heat exchanger was formed into shell and tube type. R-22 and R-141b were used as the working fluids of OHP with a fill ratio of 40 vol.%. Water was used as the working fluid of shell side. As the experimental parameters, the inlet temperature difference between heating and cooling water and the mass velocity of water were changed. The mass velocity of water was changed from 30 kg/$m^2$s to 92 kg/$m^2$s. The experimental results showed that the heat recovery rate linearly increased as the mass velocity and the inlet temperature difference of water increased. Finally, the performance of OHP heat exchanger was evaluated by $\varepsilon$-NTU method. It was found that the effectiveness would be 80% if NTU were about 1.5.