• Title/Summary/Keyword: Closed Reduction

Search Result 535, Processing Time 0.037 seconds

Reduction of the Axial Force of Water Pump Using CFD (전산유체역학을 이용한 워터펌프 축력 저감)

  • Jo, Sok-Hyun;Shin, Dong-Sung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.3
    • /
    • pp.83-87
    • /
    • 2012
  • Computational Fluid Dynamics (CFD) method has been used to investigate the axial force of automotive water pump. As the excessive axial force can make some unexpected problems like impeller interference and coolant leakage we have focused on finding the cause of axial force and its reduction in this paper. First, we have tested the closed type water pump with and without balance hole by the calculation methods. By examining the pressure contour around the impeller, we have found that the axial force arises not only from the pressure difference around shroud but also from the pressure difference around hub. So we have tested two impellers - one is normal open type impeller and the other is open type impeller with modified hub. The results show that the axial force reduction is about 150~200N for normal one and 700N@3000RPM for modified impeller. And the hydraulic efficiency which is important in aspect of engine fuel efficiency is reduced about 6.5% for normal one but increased 4%@3000RPM for modified impeller.

The Management of Bilateral Interfacetal Dislocation with Anterior Fixation in Cervical Spine : Comparison with Combined Antero-Posterior Fixation

  • Kim, Ki-Hong;Cho, Dae-Chul;Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.4
    • /
    • pp.305-310
    • /
    • 2007
  • Objective : Combined antero-posterior fixation has been a standard method for bilateral interfacetal dislocation in cervical spine. The purpose of this study is to evaluate the efficacy and complication of anterior cervical stabilization in treatment of bilateral interfacetal dislocation. Methods : A total of 65 cases of traumatic bilateral interfacetal dislocation in cervical spine who were managed in our institution, from Mar. 1997 to Feb. 2006, were included in this study. Closed reduction was tried in all cases before operation. If closed reduction was accomplished successfully, only anterior cervical fixation was performed (Group I), and attempted to place screws bicortically as possible with unicortical screws. If failed, posterior open reduction with fixation was first tried, followed by anterior cervical fixation (Group II). All patients were evaluated for neurological outcome and radiological evidence of healing. Results : The Group I included 47 patients and the Group II, 18 patients. The improvement of Frankel grade and increase of mean cervical lordosis angles were not statistically different between two groups. Screw-plate system used did not influence the outcome. On follow up, solid bone fusion was evident and there were no cases of instability in both groups. Conclusion : Our study demonstrated that anterior cervical fixation on BID is safe and effective in comparison with combined antero-posterior cervical fixation.

Chorpart's Dislocation: A Case Report (중족근 관절 탈구: 1예 보고)

  • Choi, Jun-Weon;Choi, Joon-Choil;Na, Hwa-Yeop;Shim, Dong-Joon;Kim, Young-Ho;Lee, Sang-Ho;Cho, Hyoung-Wook
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.1
    • /
    • pp.121-124
    • /
    • 2005
  • The midtarsal joint which consists of the talonavicular and calcaneocuboid joints lies transversely across the medial and lateral arches of the foot. Complete dislocation of this joint unassociated with fracture is extremely rare. A 36 year-old male who was injured by motor vehicle accident came to help for his left midfoot pain and deformity. We misdiagnosed as subtalar dislocation. Closed reduction was performed. We reviewed initial and post-reduction X-rays, and then we diagnosed as Chopart's dislocation. CT scan was taken; it showed fracture of the anterior process of the calcaneous.

  • PDF

Clinical Usefulness of a Newly Standardized Bird's Eye View Clinical Photography in Nasal Bone Fracture (코뼈 골절 수술결과 평가에 있어서 Bird's Eye View의 유용성)

  • Park, Dong Kwon;Choi, Jae Hoon;Lee, Jin Hyo
    • Archives of Craniofacial Surgery
    • /
    • v.12 no.2
    • /
    • pp.97-101
    • /
    • 2011
  • Purpose: Nasal bone fracture is the most common type of facial bone fracture. The standard 6-view photography was not adequate to support the evaluation of nasal deformity and the results of closed reduction. The authors have standardized a bird's eye view photography to more effectively evaluate this nasal deformity. Methods: We reviewed the medical records and radiologic studies of 63 nasal bone fracture patients. We had taken clinical photography including bird's eye view that was standardized as nasal tip was aligned to Cupid's bow of upper lip and light was focused on the nasion of all 63 patients. Results: Nasal deviations and reductions were more noticeable on the newly standardized bird's eye view. This clinical photography was very useful to explain the results of reduction. Conclusion: It was concluded that this photography can be more reliable for evaluation of severity of nasal deformity and the result of closed reduction.

The measurement of nose dimensions through the three-dimensional reformation images after nasal bone fracture

  • Jang, Seung Bin;Han, Dong Gil
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.1
    • /
    • pp.31-36
    • /
    • 2019
  • Background: After closed reduction, patients are sometimes concerned that their external nasal shapes have changed. The aim of this study was to investigate and explain changes in nasal shape after surgery through objective photogrammetric anthropometry measurements taken through three-dimensional (3D) reformed computed tomography (CT) images. Methods: Our study included 100 Korean patients who underwent closed reduction of isolated nasal bone fracture from January 2016 to June 2017. Using the ruler tool in Adobe Photoshop CS3, we measured preoperative and postoperative nasal base heights, long nostril axis lengths, both nasal alar angles, and amount of nasal deviation through the 3D reformation of soft tissue via CT scans. We then compared the dimension of nose. Results: The amount of postoperative correction for nasal base height was 1.192 mm. The differences in nostril length between each side were found to be 0.333 mm preoperatively and 0.323 mm postoperatively. The differences in the nasal alar angle between each side was $1.382^{\circ}$ preoperatively and $1.043^{\circ}$ postoperatively. The amount of nasal deviation was found to be 5.248 mm preoperatively and 1.024 mm in postoperatively. Conclusion: After the reduction of nasal bone fractures, changes in nasal dimensions were noticeable in terms of nasal deviation but less significant in nasal tips, except for changes in nasal alar angles, which were notable.

Closed Reduction of Nasal Bone Fracture Under the Mask Ventilation Anesthesia Using Oral Airway (기도유지기 마스크 환기마취를 이용한 비관혈적 비골골절 정복술)

  • Park, Byung-Chan;Nam, Hyun-Jae;Lee, Jun-Ho;Kim, Yong-Ha;Heo, Min-Jung;Seo, Il-Sook
    • Archives of Craniofacial Surgery
    • /
    • v.9 no.2
    • /
    • pp.77-80
    • /
    • 2008
  • Purpose: The majority of nasal fractures have been treated by closed reduction. And they were manipulated under local anesthesia or general anesthesia. Under the local anesthesia, patients can feel the pain and fear, so general anesthesia through the endotracheal intubation became popularized recently to treat the nasal fracture. But it has still the drawbacks of postanesthetic complication. Therefore, under the mask ventilation anesthesia using oral airway, we tried to manipulate the nasal fracture. Methods: From July 2007 to November 2007, we worked with fifty patients that were manipulated the nasal fracture. Fifty patients were divided into two groups, general anesthesia with the endotracheal intubation group(n=25) and the mask ventilation using oral airway group(n=25). We checked up the anesthesia time, postanesthetic complication, postoperative aesthetic & functional problem of nose in two groups. Results: In total operation time and sore throat frequency among the postoperative anesthetic complications, there was statistically significant difference between the mask ventilation group and the endotracheal intubation group(p<0.05). But there was no difference statistically in nausea frequency(p>0.05). And no patients complained of postoperative nasal complication such as septal deviation, septal perforation, nasal obstruction and hump nose in two groups. Conclusion: Through the mask ventilation using oral airway, we could reach satisfactory results in the anesthetic time and postanesthetic complication.

Extension block and direct pinning methods for mallet fracture: A comparative study

  • Han, Hyun Ho;Cho, Hyun Jun;Kim, Seong Yeon;Oh, Deuk Young
    • Archives of Plastic Surgery
    • /
    • v.45 no.4
    • /
    • pp.351-356
    • /
    • 2018
  • Background Mallet fracture can easily occur during sports activities or in daily life; however, the principles and methods of treatment for such fractures remain debated. Among the surgical treatments, various methods of closed reduction have been proposed. We treated patients with the extension block method (EBM) and the direct pinning method (DPM), and then compared the results. We assessed differences in range of motion and measurements of finger movement after surgery. Methods A total of 41 patients who underwent surgery from August 2013 to September 2015 were evaluated retrospectively. Among them, 21 patients were treated with the EBM and 20 patients were treated with the DPM. We then compared extensor lag, range of motion, and outcomes according to Crawford's criteria between before surgery and at 6 to 8 months postoperatively. Results The postoperative extensor lag improvement was $4.28^{\circ}$ and $10.73^{\circ}$, and the postoperative arc of motion was $55.76^{\circ}$ and $61.17^{\circ}$ in the EBM and DPM groups, respectively. The Crawford assessment showed no statistically significant difference between the groups, although the score in the DPM group was higher than that in the EBM group (3.5 vs. 3.1). Conclusions As closed reduction methods for the treatment of mallet fracture, both the EBM and DPM showed good results. However, the DPM proved to be superior to the EBM in that it produced greater improvements in extensor lag and range of motion.

Enlarged Lipogranuloma after Closed Reduction of Nasal Bone Fracture: A Case Report (비골골절 정복술 후 커진 지방육아종의 치험례)

  • Lee, Ji Won;Choi, Jae Il;Ha, Won;Yang, Wan Suk;Kim, Sun Young
    • Archives of Craniofacial Surgery
    • /
    • v.13 no.1
    • /
    • pp.63-67
    • /
    • 2012
  • Purpose: Lipogranuloma is the reaction of adipose tissue to various oils, paraffin, and other hydrocarbons injected into subcutaneous tissue for cosmetic or other reasons. The authors experienced a case of sclerosing lipogranuloma on the nasal dorsum. Methods: A 42-year-old female, without a history of the injection of any foreign materials, was admitted on our hospital for a painless, irregular, and firm mass located on her nasal dorsum with step-off deformity. It was considered that the mass had developed after augmentation rhinoplasty. The size of mass had been increased after closed reduction of nasal bone fracture. On April 2011, under general anesthesia, the mass was removed by open rhinoplasty technique. In addition, a pathologic examination was performed. After the mass extirpation, dermofat graft was performed for the correction of depression deformity. Results: The histopathological findings demonstrated a Swiss cheese pattern with variably-sized vacuoles, which corresponded to lipid removed with tissue processing, and variable foreign body giant cell reaction, fat necrosis, and hyalinized fibrous tissue. The pathologic diagnosis is lipogranuloma replacing nasalis muscle. It has been considered that sclerosing lipogranuloma is caused by nerve injury during augmentation rhinoplasty and the ointment used after the closed reduction of nasal bone fracture, which infiltrated through the injured mucosa. Conclusion: During the treatment of rhinoplasty or nasal bone fracture, the nerve injury or the ointment use can lead to lipogranuloma. Therefore, careful dissection for avoidance of the nerve injury and limited use of ointment seems to be helpful in decreasing incidence of lipogranuloma.

Research of the Development of a Height-adjustable light-shelf based on an Open and Closed Concept - Focusing on the light-shelf Performance Evaluation Depending on the External Illumination- (개폐 개념의 높이 조절이 가능한 광선반 개발 연구 - 외부조도에 따른 광선반 성능평가 중심으로)

  • Kim, Surin;Lee, Heangwoo;Song, Seonkjae;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.83-90
    • /
    • 2017
  • Purpose: With the increase in the energy consumption in the building sector, many studies have recently been conducted to address this issue. Due to its efficiency, diverse studies on a light-shelf, which is a natural lighting system, are in progress. However, there has been no research on the external illumination that determines the performance of a light-shelf. Therefore, the present study aimed to prepare the external illumination standard for securing the lighting performance of a light-shelf through the light-shelf performance evaluation based on a 1:1 scale testbed, and to suggest a height-adjustable light-shelf based on an open and closed concept for the case in which the lighting performance of the light-shelf significantly deteriorates, by collecting the external illumination. Method: In this study, a 1:1 scale testbed was established for performance evaluation, and the external illumination standard for securing the performance of the light-shelf was prepared by comparing the lighting performance of the light-shelf depending on the open and closed condition of the light-shelf and the external illumination. Result: 1) In this study, a light-shelf that can be opened or closed depending on the external illumination was suggested. As a result, the prospect right can be secured by creating the condition where there is no light-shelf installation by moving the light-shelf to the top of the window when the lighting performance is not secured. 2) In the summer solstice, the external illuminations appropriate for lighting energy reduction were more than 75,000 lx and 60,000 lx for the light-shelf width of 0.3 m and 0.6 m, respectively. 3) In the intermediate period, the external illumination appropriate for lighting energy reduction was 60,000 lx. In the winter solstice, making the condition where there is no light-shelf installation by closing the light-shelf would be appropriate. 4) Based on the aforementioned results, the external illumination standard for the opening and closing of the height-adjustable light-shelf based on an open and closed concept suggested in this study was 60,000 lx, and the light-shelf with a width of 0.6 m would be advantageous for lighting energy reduction.

Evaluation of Biomechanical Properties of Fractured Adjacent Soft Tissue Due to Fracture Site Spacing During Closed Reduction After Forearm Fracture: Finite Element Analysis (전완 골절 후 도수 정복 시 골절 부위 간격에 따른 골절 인접 연부 조직의 생체역학적 특성 평가: 유한요소해석)

  • Park, Jun-Sung;Lee, Sang Hyun;Song, Chanhee;Ro, Jung Hoon;Lee, Chiseung
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.5
    • /
    • pp.308-318
    • /
    • 2022
  • The purpose of this study is to evaluate the biomechanical properties of fractured adjacent soft tissue during closed reduction after forearm fracture using the finite element method. To accomplish this, a finite element (FE) model of the forearm including soft tissue was constructed, and the material properties reported in previous studies were implemented. Based on this, nine finite element models with different fracture types and fracture positions, which are the main parameters, were subjected to finite element analysis under the same load and boundary conditions. The load condition simulated the traction of increasing the fracture site spacing from 0.4 mm to 1.6 mm at intervals of 0.4 mm at the distal end of the radioulnar bone. Through the finite element analysis, the fracture type, fracture location, and displacement were compared and analyzed for the fracture site spacing of the fractured portion and the maximum equivalent stress of the soft tissues adjacent to the fracture(interosseous membrane, muscle, fat, and skin). The results of this study are as follows. The effect of the major parameters on the fracture site spacing of the fractured part is negligible. Also, from the displacement of 1.2 mm, the maximum equivalent stress of the interosseous membrane and muscle adjacent to the fractured bone exceeds the ultimate tensile strength of the material. In addition, it was confirmed that the maximum equivalent stresses of soft tissues(fat, skin) were different in size but similar in trend. As a result, this study was able to numerically confirm the damage to the adjacent soft tissue due to the fracture site spacing during closed reduction of forearm fracture.