• Title/Summary/Keyword: Close loop

Search Result 171, Processing Time 0.024 seconds

Three-Channel Output Multiplexer Design Using Band-Pass Filter and Ultra-Wideband Antenna

  • Lee, Jung Nam;Park, Jong Kweon
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.2
    • /
    • pp.100-105
    • /
    • 2016
  • We have designed a three-channel output multiplexer (OMUX) using a band-pass filter and an ultra-wideband (UWB) antenna. The proposed band-pass filter is composed of an inner rectangular loop, an outer open stub, and a defected ground structure. The outer open stub can be used to control the pass band, and the inner rectangular loop can improve the insertion loss characteristics of the band-pass filter. The proposed band-pass filter, UWB antenna, and OMUX are fabricated and measured. The designed OMUX can cover the band group 1 (3,168-4,752 MHz) of WiX system. The measured radiation patterns are close to those of a conventional dipole antenna and the measured antenna gain varies from 1.8 dBi to 3 dBi over the operating frequency range.

Height Dependence of Plasma Properties in a Solar Limb Active Region Observed by Hinode/EIS

  • Lee, Kyoung-Sun;Imada, S.;Moon, Y.J.;Lee, Jin-Yi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.110.2-110.2
    • /
    • 2012
  • We investigate a cool loop and a dark lane over a limb active region on 2007 March 14 by the Hinode/EUV Imaging Spectrometer (EIS). The cool loop is clearly seen in the EIS spectral lines formed at the transition region temperature (log T = 5.8). The dark lane is characterized by an elongated faint structure in coronal spectral lines (log T = 5.8 - 6.1) and rooted on a bright point. We examine their electron densities, Doppler velocities, and non-thermal velocities as a function of distance from the limb using the spectral lines formed at different temperatures (log T = 5.4 - 6.4). The electron densities of the cool loop and the dark lane are derived from the density sensitive line pairs of Mg VII, Fe XII, and Fe XIV spectra. Under the hydrostatic equilibrium and isothermal assumption, we determine their temperatures from the density scale height. Comparing the scale height temperatures to the peak formation temperatures of the spectral lines, we note that the scale height temperature of the cool loop is consistent with a peak formation temperature of the Mg VII (log T = 5.8) and the scale height temperature of the dark lane is close to a peak formation temperature of the Fe XII and Fe XIII (log T = 6.1 - 6.2). It is interesting to note that the structures of the cool loop and the dark lane are most visible in these temperature lines. While the non-thermal velocity in the cool loop slightly decreases (less than 7 km $s^{-1}$) along the loop, that in the dark lane sharply falls off with height. The variation of non-thermal velocity with height in the cool loop and the dark lane is contrast to that in off-limb polar coronal holes which are considered as source of the fast solar wind. Such a decrease in the non-thermal velocity may be explained by wave damping near the solar surface or turbulence due to magnetic reconnection near the bright point.

  • PDF

A Study on Characteristics of Effective Thermal Conductivity of a horizontal Close-Loop Ground Heat Exchanger using in In-situ Thermal Response Test method (현장열응답 시험을 통한 수평형 지중열교환기의 지중열전도도 특성 연구)

  • Kim, Min-Jun;Choi, Choong-Hyun;Woo, Jeong-Tae;Chang, Keun-Sun;Choi, Youn-Sung;Lee, Hyun-Su;Kim, Ju-Houng
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.122.1-122.1
    • /
    • 2010
  • 수평형 지중열교환기의 지중온도 및 지중열전도도를 분석하기 위해서 경기테크노파크 화단에 수평형 지중열교환기를 설치하였다. 수평형 지중열교환기는 수평 길이 50m, 폭 2.7m, 깊이 2m에 파이프 규격 30mm, 파이프 길이 400m 1본을 매설하였다. 2009년 7월부터 2010년 5월까지 총 7회에 걸쳐 현장열응답방식을 이용하여 지중열전도도를 측정하였다. 측정결과를 분석해보면 수평형 지중열교환기의 지중온도는 계절적인 영향을 많이 받았으며, 지중열전도도는 계절적인 요인과는 무관하게 $1.51{\pm}0.1W/mk$ 범위에서 잘 일치함을 보였다. 이러한 결과로서 수평형 지중열교환기의 현장열응답시험은 현장설치 조건을 모두 반영한 결과를 도출할 수 있을 것으로 판단된다.

  • PDF

Current Mode PWM Control for the Buck Converter Using One Cycle Response (한주기 응답 기법을 적용한 벅 컨버터의 전류 모드 PWM 제어)

  • 전칠환;김철웅
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.5
    • /
    • pp.1117-1125
    • /
    • 2000
  • A current mode PWM method applied one cycle response to averaging circuit model Buck converters is presented. The controller nonlinear PWM implement is based on the error between the switched variable and the response reference to zero each cycle. As the result, the system transfer function is derived as a function of the desired close loop poles, simplifying the design procedure and bringing forward all the important characteristics of the close loop system. The proposed controller has significant advantages over conventional current mode control methods in noise susceptibility, dynamic response and without inductor current sensing, Finally, the simulation and experiment results confirm the proposed PWM control techniques.

  • PDF

A Study on the Kinetodynamic Analysis for General Disk Cam Driving Slider Mechanisms (캠구동 슬라이더기구의 기구동역학 해석에 관한 연구)

  • Shin, Joong-Ho;Kim, Jong-Soo;Ha, Kyong-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.6
    • /
    • pp.871-883
    • /
    • 1997
  • Kinetodynamics of a cam driving slider mechanism consists of kinematic analysis and force analysis. The kinematic analysis is to determine the kinematic characteristics of a cam driving mechanism and a slider mechanism. The force analysis is to determine the joint forces of links, the contact forces of the cam and follower, and the driving torque of a main shaft. This paper proposes a close loop method and a tangent substitution method to formulate the relationships of kinematic chains and to calculate the displacement, velocity and acceleration of the cam driving slider mechanism. Also, and instant velocity center method is proposed to determine the cam shape from the geometric relationships of the cam and the roller follower. For dynamic analysis, the contact force and the driving torque of the cam driving slider mechanism are calculated from the required sliding forces, sliding motion and weight of the slider.

A Control Strategy Based on Small Signal Model for Three-Phase to Single-Phase Matrix Converters

  • Chen, Si;Ge, Hongjuan;Zhang, Wenbin;Lu, Song
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1456-1467
    • /
    • 2015
  • This paper presents a novel close-loop control scheme based on small signal modeling and weighted composite voltage feedback for a three-phase input and single-phase output Matrix Converter (3-1MC). A small non-polar capacitor is employed as the decoupling unit. The composite voltage weighted by the load voltage and the decoupling unit voltage is used as the feedback value for the voltage controller. Together with the current loop, the dual-loop control is implemented in the 3-1MC. In this paper, the weighted composite voltage expression is derived based on the sinusoidal pulse-width modulation (SPWM) strategy. The switch functions of the 3-1MC are deduced, and the average signal model and small signal model are built. Furthermore, the stability and dynamic performance of the 3-1MC are studied, and simulation and experiment studies are executed. The results show that the control method is effective and feasible. They also show that the design is reasonable and that the operating performance of the 3-1MC is good.

Reliability analysis of the switch installation in the main feeder and in the radial/loop lateral feeders in distribution system (간선 및 분기선의 개폐기 설치 효과 분석(I))

  • Cho, Nam-Hun;O, Jae-Hyeong;Lee, Heung-Ho;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.79-82
    • /
    • 2002
  • The addition of switches to a distribution feeder does, in general, increase reliability by decreasing the duration of the outage of many to the customers on the feeder. To cover its service area so that feeder-level delivery reaches sufficiently close to all customers, feeders typically split their routes many times, in what is often called a lateral feeder. It is interesting to note, however, that the effectiveness of a switch is very much dependent on the types of lateral feeder. The types of lateral are classified into two types. The first is loop lateral feeder that can connect its load to an adjacent feeder through a tie line in case that a fault occurs in its feeder and it is laid out so that every feeder has complete fault backup through re-switching of its loads to other sources like a main feeder. The second is the radial lateral feeder cannot connect its load to an adjacent line, no provision is made for contingency backup of feeders. There are no other circuits in the radial lateral feeder form which to restore power. In this study, we evaluate the effectiveness of a switch installation between on the radial and loop lateral feeders to increase reliability by decreasing the duration of the outage. These results can help power utility to design the switch layouts on the radial and loop lateral feeder system.

  • PDF

Design and Structural Analysis on the Open and Close Hinge for Complex Machine (복합기 커버 개폐용 힌지의 설계와 구조 해석)

  • Yun, Yeo-Kwon;Yang, Kwang-Mo;Kim, Do-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.2
    • /
    • pp.49-54
    • /
    • 2012
  • As all kind of industry has developed, metal structure and machine instrument use bolt, pin, rivet and welding for assembly and combination. For pin and hinge, dimension accuracy is crucial to keep the operation and safety of the structure and machine instrument. In case of complex machine, the hinge for cover open-loop system is one of the significant design elements. Most of the hinges are being imported and assembled sine they give high technology development cost for its unit cost position. The reason is that the localization of hinge is inadequate. As the demand increase and the necessity of localization grow, it is now more important than ever to develop low cost structure. By the low cost structure, a new technology could be obtained for electronic product and structural hinge since it would enable for complex machine hinge to be guaranteed, technologically. Open-loop hinge is the link type and designed for the structure to keep constant open-loop. And, the hinge is examined in design stability by finite element analysis method. In this paper, the operation result is presented when the hinge for complex machine open-loop is designed for link type structure.

Performance Analysis of Hybrid Heat Pump System of the Air-to-Air/Air-to-Water with the Ambient Temperature (외기온 변화에 따른 공기-공기/공기-물 형태로 된 복합형 열펌프 시스템의 성능 특성 분석)

  • 송현갑
    • Journal of Biosystems Engineering
    • /
    • v.25 no.4
    • /
    • pp.273-278
    • /
    • 2000
  • The hybrid heat pump system of the air to air and / or air to water was composed and its COP was analyzed with the ambient temperature on the opened and closed loop system respectively. The results be indicated by the equation(7) that the COP(Coefficient of Performance) of air-source(air to air and / or air-water) heat pump is effected with the ambient air temperature and AVACTHE.(Automatic Variable Area Capillary Type Heat Exchanger) 2. The COP of air-to-water heat pump without AVACTHE decreased in accordance with the ambient temperature decrease, however in case of the heat pump with AVACTHE the COP was maintained at 2.8∼3.0 level when the ambient temperature decrease from -$5^{\circ}C$ to $-11^{\circ}C$. 3. The COP of the air-to-water heat pump operated on the open loop was higher 40∼58% than that of the heat pump operated on the close loop. 4. The lower ambient temperature air effect on the COP of the air-to-air heat pump operated on the semi closed loop could be controlled using the AVACTHE, and at the high ambient air temperature the COP increased using the Bypass circuit.

  • PDF