• Title/Summary/Keyword: Clinical usefulness

Search Result 1,037, Processing Time 0.044 seconds

Early assessment of atherosclerosis in children with type 1 diabetes (제1형 당뇨병 소아 환자에서 동맥경화증의 조기 평가)

  • Park, So-Yoon;Kang, Seok Jeong;Choi, Kwang Hae;Park, Yong Hoon;Lee, Young Hwan
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.7
    • /
    • pp.747-753
    • /
    • 2008
  • Purpose : Diabetes mellitus is a major risk factor for the development of cardiovascular disease. Early atherosclerotic changes in the arterial walls begin in adolescence and the risk factors are associated with its development. To assess the usefulness of carotid artery intima-media thickness (IMT), as a marker of early atherosclerosis, we evaluated the structural and functional characteristics of the carotid artery and investigated their relationshop with the metabolic and anthropometric parameters in children and adolescents with type 1 diabetes. Methods : For this study, we enrolled 23 children with type 1 diabet and 19 age and sex-equivalent healthy children as the control group. Metabolic and anthropometric parameters such as serum lipid levels, plasma glycated hemoglobin (HbA1c), and body mass index were measured after a 12-h fasting period. The carotid artery IMT was measured by a high-quality ultrasound system, and compliance, and distensibility were calculated by an equation. Results : There were no significant differences between the 2 groups with regard to the sex ratio, age, blood pressure and serum cholesterol levels' however, HbA1c levels were significantly higher in the diabetic children ($8.5{\pm}1.8$ vs. $5.0{\pm}0.2$, P=0.001). Ultrasonographic findings showed that compared with the control group, the diabetic group had higher IMT ($0.45{\pm}0.06mm$ vs. $0.41{\pm}0.04mm$, P=0.04), but there were no significant differences in compliance and distensibility. The HbA1c (P=0.002) and high-density lipoprotein cholesterol (P=0.026) levels were independent IMT predictors in the diabetic group. Conclusion : Here, the carotid artery IMT was higher in the diabetic group, and it is correlated with atherosclerotic risk factor. Thus, carotid IMT could be evaluated as a marker of early atherosclerosis in diabetic children.

One Anchor Double Fixation (OADF) Technique for Arthroscopic Bony Bankart Repair (두가닥의 봉합사를 가진 봉합나사못을 이용한 새로운 관절경적 골성 방카르트 병변 봉합술)

  • Choi, Eui-Sung;Park, Kyoung-Jin;Kim, Yong-Min;Kim, Dong-Soo;Shon, Hyun-Chul;Cho, Byung-Ki;Bae, Seung-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2010
  • Purpose: The aim of this study was to evaluate the usefulness of arthroscopic Bony Bankart repair using a One Anchor Double Fixation Technique. Materials and Method: Seventeen patients with a Bony Bankart lesion were treated using the One Anchor Double Fixation Technique (OADF Technique). There were 13 males and 4 females. The average age was 24 years (range 17-42). The average follow-up period was 22.3 months. One 3.0 mm suture anchor with doubly loaded sutures was inserted into the glenoid rim. One suture strand was passed the around the small bony fragment and tied first. Another suture strand was passed through the capsule and tied over the bony fragment. The result was measured using Rowe's evaluation index & KSS score. The glenoid defect & bony fragment were measured by 3D-CT scan. Results: Rowe's evaluation index on the final follow-up showed an overall improvement from an average of 54 (range, 23-71) to 83.4 (range 71-90). Of the 17 cases, 13 were excellent, 3 were good, and 1 was fair. KSS scores showed improvement from an average of 71 (range 49-82) to 92.5 (range 82-94). There were no cases where pain continued to the final follow-up, and no cases being re-dislocated during the follow-up period. For six cases, we confirmed the bony healing of the bony Bankart lesion by CT. Conclusion: Bony Bankart lesion repair using this new method achieves excellent clinical results with low recurrence rates and is considered another choice for bony Bankart lesions.

The Usefulness of the Abdominal Computerized Tomography for the Diagnosis of Childhood Obesity and Its Correlation with Various Parameters of Obesity (소아 복부비만 진단을 위한 복부 전산화 단층 촬영의 유용성과 여러 지표와의 상관성 연구)

  • Shim, Yoon Hee;Cho, Su Jin;Rhyu, Jung Hyun;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.10
    • /
    • pp.1082-1089
    • /
    • 2005
  • Purpose : Abdominal obesity is encountered as a risk factor for cardiovascular diseases. However, the anthropometric cut-off value to estimate the cardiovascular risk, has not been suggested. This study was designed to find the relationship between the abdominal fat and various parameters of obesity to find the cardiovascular risk factors related to abdominal obesity and to establish practical methods to measure them. Methods : Twenty seven obese Korean adolescents of moderate to severe degree and 22 healthy adolescents were enrolled. The body mass index(BMI), arm circumference and skinfold thickness were measured. Furthermore, blood lipid, sugar, insulin and four different cytokines' levels were checked and the distribution of body composition was measured by bioelectrical impedance analysis. The subcutaneous and intra-abdominal fat thickness by abdominal ultrasonography(US) and the total and intra-abdominal fat area by abdominal computerized tomography(CT) were measured in the obese group. Results : The most accurate method to measure abdominal fat in children is abdominal CT and the fat mass measured by bioelectrical impedance was strongly correlated with it(r=0.954). It was also correlated with arm circumference, fat thickness measured by abdominal US, BMI, aspartate aminotransferase(AST), alanine aminotransferase(ALT) and triglyceride level. Conclusion : Abdominal CT is the most accurate method to measure intra-abdominal fat, and it can be replaced by abdominal US for cost effectiveness. The screening methods that can be used at school or in outpatient basis include bioelectrical impedance, waist/hip ratio, and arm circumference. The cardiovascular risk factors include leptin, triglyceride and insulin level.

Usefulness of modified ambu® in patients who need artificial ventilation (인공 환기가 필요한 환자에서 변형된 수동식 인공호흡기(Ambu®)의 유용성)

  • Ha, Kee Soo;Moon, Il Hong;Lee, Hee Sun;Shin, Dong Han;Eun, So Hee;Eun, Baik-Lin;Hong, Young Sook;Lee, Joo Won
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.11
    • /
    • pp.1194-1201
    • /
    • 2006
  • Purpose : The comatose mentality can be catastrophic, especially if the condition is severe or the duration is prolonged. Therefore, delayed diagnosis can result in a poor outcome or death. The best radiologic modality to differentiate from cerebral lesions in patients suffering from cerebral diseases is magnetic resonance imaging (MRI) rather than computed tomography (CT). Special apparatuses with metal materials such as ventilators, and cardiac pacemakers belonging to patients cannot be located in the magnetic field. We aimed to exhibit the possibility of examining MRI, maintaining ventilation at a relative long distance by means of modified $Ambu^{(R)}$. Methods : Self-inflating bags as a sort of a manual ventilator, connected with relatively long extension tubes instead of mechanical ventilators, were adopted to obtain MRI. PVC (polyvinyl chloride) extension tubes had different lengths and diameters. Lengths were 1, 2, and 3 cm and diameters were 15, and 25 mm. The work of breathing and expiratory changes of expiratory tidal volume (TVe), minute volume of expiration (MVe), peak inspiratory pressure (PIP) were measured by use of the mechanical ventilator, $Servoi^{(R)}$, as the alteration of TVi (inspiratory tidal volume), extension tube lengths and diameters with other values fixed. Results : Measured TVe and MVe by ventilator were the same values with control at every TVi, regardless of extension tube lengths and diameters, but PIP were increased with the rise of TVi, tube lengths, with decline of tube diameters, these were statistically significant. Conclusion : MRI examination can be carried out with a self-inflating bag connected with an extension tube at a long distance in patients who need artificial ventilation.

The Etiologic Diseases and Diagnostic Usefulness of Color Doppler Ultrasonography in Children with Chronic Coughs (소아 만성 기침의 원인 질환과 컬러 도플러 초음파 검사의 진단적 유용성)

  • Park, Sun Young;Lee, Joon Sung
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.4
    • /
    • pp.489-497
    • /
    • 2002
  • Purpose : The objectives of this study were to investigate the causes of chronic cough and to establish the appropriate diagnostic approach to chronic cough in children. Methods : One hundred and thirty two cases of chronic cough were prospectively evaluated. They visitors to pediatric chronic cough clinics at Kang-nam saint Mary's Hospital of Catholic University from August 2000 to July 2001 for 12 months. Careful history taking by questionnaire, physical examination, radiologic studies of chest and sinus, hematologic and immunologic studies, allergic skin tests, and methacholine challenge tests were performed. Color doppler(CD) ultrasonography were performed and compared with simultaneous 24 Hr. esophageal pH monitoring to diagnose gastroesophageal reflux disease(GERD). Results : Age distributions were demonstrated that nine in infants, 82 in early childhood, 38 in late childhood, and three in adolescence. Common causes of chronic cough were bronchial asthma in 40 cases, chronic sinusitis in 22 cases, GERD in seven cases, bronchial asthma combined with sinusitis in 28 cases, bronchial asthma combined with GERD in 14 cases, psychogenic cough in two. cases, foreign body in one case, chronic bronchitis in one case, and bronchiolitis in one case. Comparing with 24 Hr. pH monitoring, sensitivity, specificity, positive predictive value and negative predictive values of CD ultrasonography were 88%, 69%, 85 %, and 73% respectively. Conclusion : The most common causes of chronic cough in children were bronchial asthma, sinusitis and GERD in order. We suggest that CD ultrasonography can be used as a good, convenient screening method for patients with suspected GERD in outpatient settings.

A Study on Calibration Procedures for Ir-192 High Dose Rate Brachytherapy Sources (고선량률(HDR) 근접치료의 동위원소 Ir-192에 대한 측정방법에 관한 고찰)

  • Baek, Tae-Seong;Lee, Seung-Wook;Na, Soo-Kyong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.19-26
    • /
    • 2007
  • Purpose: To compare of the accuracy among various measurement procedures of HDR Brachytherapy, and to evaluate the clinical suitability and usefulness of alternative PMMA (polymethylmethacrylateplastics: $C_5H_8O_2$) plate phantom without any additional cost due to the purchase of measuring apparatus. Materials and Methods: We made a comparative study on three types of measuring systems: well type chamber, source calibration jig, and PMMA plate phantom. Farmer type chamber was used for source calibration jig method and PMMA plate phantom method. Measurement was done 5 times each in comparison with the measurement values from manufacturer. Measurement results from experiment were compared with that from the manufacturer which is offered with the source whenever a source is substituted by a new one and evaluate the accuracy of source activity. Results: As a consequence of Ir-192 source measurement using well type chamber, source calibration jig and PMMA plate phantom, RMS (Root Mean Square) values for the relative error are 0.6%, 1.57%, 2.1%, respectively, compared with the data from manufacturer. And the mean errors with standard deviation are given $-0.2{\pm}0.5%$, $0.97{\pm}1.23%$, $-0.89{\pm}1.87%$ respectively. Conclusion: From the results shown by the three types of measurement system (well type chamber, source calibration jig, and PMMA plate phantom), the measurement with well type chamber produced the best accuracy. It turns out that we can also use the alternative system of PMMA plate phantom clinically without purchasing any additional particular apparatus since the system does not exceed the recommendation of AAPM (American Association of Physicists in Medicine), which requires the error range of within ${\pm}5%$.

  • PDF

Ultrasonographic Assessment for Rotator Cuff Repair According to the Tear Sizes and the Repair Method (회전근 개 파열의 크기 및 봉합 방법에 따른 초음파를 이용한 추적검사의 유용성)

  • Choi, Chang-Hyuk;Park, Jae-Hyun;Shin, Dong-Young;Lee, Jae-Kun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.53-61
    • /
    • 2009
  • Purpose: This study was designed to evaluate the clinical usefulness of serial ultrasonography (USG) after arthroscopic rotator cuff repair and to assess the re-tear rate and the re-tear time according to the tear sizes and the repair method. Materials and Methods: Between January 2008 and June 2008, 52 patients were treated with arthroscopic rotator cuff repair, Of the 52 patients, 29 patients that had undergone more than six months follow-up underwent preoperative USG examinations and subsequent arthroscopic examinations. MRI and USG findings were compared with intraoperative results of arthroscopic examinations. The postoperative integrity of the rotator cuff was observed using serial USG examination performed postoperatively at two weeks, six weeks, three months, and six months. Results: Small to medium rotator cuff tear were identified in 10 patients where the double pulley suture bridge (DPSB) technique was performed; the re-tear rate was 20%. For 19 patients with large to massive rotator cuff tears, the re-tear rates was 100% for six patients who had undergone tendon to tendon (TT) repair, the re-tear rate was 50% for two patients who had undergone tendon to tendon and bone to tendon (TTBT) repair and the re-tear rate was 55% for11 patients where the DPSB technique was performed. Re-tear rates according to follow-up periods were 7% from two to six weeks, 66% from six weeks to three months and 27% from three to six months postoperatively. Conclusion: Serial USG examinations after arthroscopic rotator cuff repair were useful to assess the re-tear rate and the re-tear time. In addition, USG examination were useful for treatment planning during postoperative rehabilitation.

  • PDF

Chest Computerized Tomographic Scan and Flexible Fiberoptic Bronchoscopy in the Diagnosis of Middle Lobe Syndrome (페중엽증후군에서 흉부 전산화 단층촬영 및 굴곡성 기관지경검사의 의의)

  • Lee, Nam-Ho;Lee, Hong-Leyol;Kim, Se-Kye;Chang, Joon;Kim, Sung-Kyu;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.3
    • /
    • pp.236-241
    • /
    • 1992
  • Background: As well as fiberoptic bronchoscopy, chest computerized tomographic scan can now differentiate the benign from malignant causes and the obstructive from non-obstructive causes of lung collapse. This study was designed to evaluate the usefulness of chest CT scan and fiberoptic bronchoscopy in the diagnosis of middle lobe syndrome. Method: We reviewed the clinical features, roentgenographic changes, pathologic findings and bronchoscopic findings in 16 patients with middle lobe syndrome who were admitted to Severance Hospital during period of January, 1987 through January, 1992. Results: The male to female ratio was 1:1. The most common symptoms were cough and sputums. Crackle was the most common physical finding. Underlying disease was lung cancer, pulmonary tuberculosis and endobronchial tuberculosis in 3 each other, benign stenosis in 2, lung abscess, broncholithiasis, bronchial chondroma, pneumonia and nonspecific inflammation in 1 each other. Conclusion: We conclude that the combination of chest computerized tomogram and fiberoptic bronchoscopy was most desirable for the diagnosis of middle lobe syndrome.

  • PDF

Usefulness of $^{99m}Tc$ Methoxyisobutylisonitrile Lung SPECT in Benign and Malignant Lesion of the Lungs (폐의 양성 및 악성 병변에서 $^{99m}Tc$ Methoxyisobutylisonitrile Lung SPECT의 진단적 가치)

  • Kim, Seong-Suk;Kim, Ki-Beom;Cho, Young-Bok;Cho, In-Ho;Lee, Kyung-Hee;Chung, Jin-Hong;Lee, Hyoung-Woo;Lee, Kwan-Ho;Lee, Hyun-Woo;Kim, Mi-Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.1
    • /
    • pp.54-62
    • /
    • 1996
  • Background: $^{99m}Tc$ MIBI(Methoxyisobutylisonitrile complex), a member of the isonitrile class of coordination compounds, is a lipophilic cation presently under investigation for clinical use as myocardial perfusion imaging agent and is widely used to detect myocardial infarction. Preliminary reports indicate that $T_1$-201 accumulate in human neoplasm and several authors reported $^{99m}Tc$ MIBI may also localized in primary malignant tumor and metastatic deposits from lung cancer. We evaluated the uptake of $^{99m}Tc$ MIBI in lung cancer and localization of mediastinal and other site metastasis, and compared the benign lesion of the lung. Method: Thirty four patients of lung cancer and ten patients of benign lung lesion were studied with chest CT and $^{99m}Tc$ MIBI Lung SPECT. $^{99m}Tc$ MIBI uptake ratio was assessed by TR/NL(Lung lesion/ Normal area), HT/NL (Heart/Normal area) and HT/TR(Heart/Lung lesion). Results: 1) All lung cancer patients showed increased uptakes of $^{99m}Tc$ MIBI in malignant lung lesion and Tc-99m MIBI uptake was also increased in mediastinal and lymph node metastasis except two cases. 2) There was significant different ratio of TR/NL between malignant and benign lesion, $3.79{\pm}1.82$ and $1.67{\pm}0.63$ on planar images, respectively(p<0.001). 3) There was no significant difference of $^{99m}Tc$ MIBI uptake ratio between squamous cell carcinoma, small cell carcinoma and adeno carcinoma($3.64{\pm}1.66$, $3.57{\pm}0.72$, $4.31{\pm}2.28$ respectively). Conclusion: $^{99m}Tc$ MIBI lung SPECT was useful in the localization of tumor and mediastinal or other site metastatic lesion in lung cancer and also in the differential diagnosis between benign and malignant lesion.

  • PDF

The Clinical Usefulness of Cephalometric Analysis in the Obstructive Sleep Apnea Syndrome (폐쇄성 수면 무호흡 증후군에서 두개골계측분석의 임상적 유용성)

  • Choi, Young-Mee;Lee, Sang-Haak;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Song, Jeong-Sup;Park, Sung-Hak;Moon, Hwa-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.2
    • /
    • pp.218-230
    • /
    • 1999
  • Background: Craniofacial anatomic abnormalities related to structural narrowing of the upper airway have been reported in patients with obstructive sleep apnea syndrome. In this study, we evaluated the craniofacial anatomic characteristics of Korean patients with obstructive sleep apnea syndrome, and the role of cephalometric analysis in the prediction of abnormal breathing during sleep. Methods: Thirty-nine patients with obstructive sleep apnea syndrome(OSAS), 39 simple snorers(simple snorers) and 20 controls(control) had cephalometric analysis using the technique of Riley et al, and underwent standardized polysomnographic recordings. Different variables, including sex, body mass index, cephalometric and polysomnographic data, were statistically analyzed. Results: Pm-UPW and V-LPW distances were significantly shorter in OSAS when compared with simple snorers or control. PAS in simple snorers was shorter than in control. ANS-Gn distance in OSAS was significantly longer than in control. PNS-P distance in OSAS or simple snorers was significantly longer than in control. MP-H distance in OSAS was significantly longer than in simple snorers or control and MP-H distance in simple snorers was also longer than in control. NL/Pm-P angle in OSAS was lesser than in control. MP-H distance in OSAS or in the combined groups of OSAS and simple snorers was significantly correlated with apneahypopnea index(AHI). PNS-P distance in the combined groups of OSAS and simple snorers was correlated with AHI. In male of all subjects, body mass index was significantly correlated with PNS-P or MP-H distance. Conclusion: Cephalometric analysis can be useful tool in determining the craniofacial anatomic abnormalities in patients with obstructive sleep apnea syndrome. Cephalometric parameters, especially MP-H distance, can be useful for predicting frequency of narrowing or obstruction of upper airway during sleep.

  • PDF