• Title/Summary/Keyword: Clinical usefulness

Search Result 1,047, Processing Time 0.036 seconds

Clinical Usefulness between High Dose Radioiodine Therapy and Helicobacter Pylori Infection after Total Thyroidectomy due to Well Differentiated Thyroid Cancer (분화 갑상선암으로 갑상선전절제술 후 고용량 방사성요오드 치료와 Helicobacter pylori 감염과의 임상적 유용성)

  • Yun, Kuk-No;Lim, Seok-Tae;Moon, Eun-Ha;Kim, Jin-Suk;Jeong, Young-Jin;Kim, Dong-Wook;Jeong, Hwan-Jeong;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.572-576
    • /
    • 2009
  • Purpose: Helicobacter (H) pylori infection has been considered the most important cause of gastritis, dyspepsia, and gastroduodenal ulcer. Radioiodine can be accumulated in the remaining thyroid tissue, salivary gland, and stomach. We investigated if the high radiation induced by radioiodine in the stomach after high dose radioiodine therapy (HD-RIT) is effective in the eradication of H. pylori infection. Materials and Methods: One hundred ninety nine patients (M:F=33:166, age $46.7{\pm}12.3$ years) who had HD-RIT (dose $159.1{\pm}25.9\;mCi$, range 120-250 mCi) after thyroidectomy due to well differentiated thyroid cancer were enrolled. To detect H. pylori infection, the urea breath tests (UBT) were performed at 1 hour before HD-RIT and at 4 weeks after HD-RIT. The results of UBT were classified as positive (${\geq}50\;dpm$) or negative (<50 dpm), and analyzed its values. Results: Of 199 patients, 103 (51.8%) patients had positive UBT before HD-RIT. Of these, 80 patients had follow-up UBT after HD-RIT. Among them, 76 (95.0%) patients had persistent positive UBT and only 4 (5.0%) patients were changed negative UBT. Among 76 patients with persistent positive UBT, 26 (34.2%) patients had increased the values of follow-up UBT, 49 (64.5%) had decreased them, and 1 (1.3%) had shown the same value. The different values of UBT between before and after HD-RIT were $62{\pm}66.1\;dpm$ in increased one of follow-up UBT, and $153.3{\pm}157.1\;dpm$ in decreased one of follow-up UBT. Conclusion: We conclude that the radiation induced by HD-RIT is ineffective in the eradication of H. pylori infection. However, it could be influential the degree or distribution of H. pylori infection.

Comparison of Clinical Usefulness between N-13 Ammonia PET/CT and Tc-99m Sestamibi SPET in Coronary Artery Disease (관상동맥질환에서 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT의 임상 유용성 비교)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Won, Kyu-Chang;Lee, Hyung-Woo;Park, Jeong-Sun;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Seop
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.354-361
    • /
    • 2008
  • Purpose: N-13 ammonia uptake and retention in the myocardium is related to perfusion and metabolism. There are several potential advantages of N-13 ammonia positron emission tomography (PET) to detect myocardial ischemia, such as higher spatial resolution, greater counting efficiencies, and robust attenuation correction. But there are few reports comparing Tc-99m myocardial perfusion single photon emission tomography (MPS) and N-13 ammonia PET. We thus compared adenosine stress N-13 ammonia PET/CT and Tc-99m sestamibi MPS in patients with suspected coronary artery stenosis. Materials and Methods: Seventeen patients (male 13 : $63{\pm}11$ years old) underwent adenosine stress N-13 ammonia PET/CT (Discovery ST, GE), Tc-99m sestamibi MPS (dual head gamma camera, Hawkeye, GE) and coronary angiography within 1 week. N-13 ammonia PET/CT and Tc-99m sestamibi MPS images were assessed with a 20-segment model by visual interpretation and quantitative analysis using automatic quantitative software (Myovation, GE). Results: Both sensitivities and specificities of detecting an individual coronary artery stenosis were higher for N-13 ammonia PET/CT than Tc-99m sestamibi MPS (PET/CT: 91%/89% vs MPS: 65%/82%). N-13 ammonia PET/CT showed reversibility in 52% of segments that were considered non-reversibile by Tc-99m sestamibi MPS. In the 110 myocardial segments supplied by the stenotic coronary artery, N-13 ammonia PET/CT showed higher count densities than Tc-99m MPS on rest study (p < 0.01), and the difference of count density between the stress and the rest studies was also larger on N-13 ammonia PET/CT. Conclusion: Adenosine stress N-13 ammonia PET/CT had higher diagnostic sensitivity and specificity, more reversibility of perfusion defects and greater stress/rest uptake differences than Tc-99m sestamibi MPS. Accordingly, N-13 ammonia PET/CT might offer better assessment of myocardial ischemia and viability.

The Clinical Usefulness Measurement of the Whole Body Percent Fat Calculated by the Part Bone Mineral Density Measurement (부분골밀도 측정을 통해 산출되는 체지방률의 임상적 유용성에 대한 평가)

  • Kang, Young-Eun;Kim, Eun-Hye;Kim, Ho-Sung;Choi, Jong-Sook;Choi, Woo-Jun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.3-9
    • /
    • 2011
  • Purpose: Generally dual energy X-ray absorptiometry has been used for the purpose of evaluation of osteoporosis and treatment. Recently the interest of obesity came to be high and body percent fat test is increasing. Existing measure of body fat have to scan the whole body can be evaluated, but only lumbar spine and hip measurements was assumed to be whole body fat as well as improving the software. It tries to check whether the part measured value not being whole body measurement has the validity or not compared with the value calculated with the method that it is different, it forgives through a correlation with a (BIA) and (BMI). Materials and Methods: In 2010, the body percent fat was measured among the examinee coming to the Asan Medical Center public health care center from March till August against 90 females more than 40 years old through (DXA) and BIA. BMI utilized the value which wrote an hight and weight measured through the body measuring instrument in the examinee information and is automatically calculated. In addition, it classified as the low weight ($13-18.5kg/m^2$), normal ($18.5-25kg/m^2$), and corpulence ($25-30kg/m^2$) based on BMI and so that it could check whether there was the difference according to the weight or not BMI and BIA and correlation between DXA were analyzed in each group. The statistical program for the analysis used SPSS 12.0. Results: The comparison of DXA at 3 which it divides into the low weight and normal and corpulence groups and BIA did not show the difference noted statistically in all groups and the between group comparison was exposed to do not have a meaning. The body percent fat measured by the correlation analysis result DXA at the state that it doesn't divide into the group showed the high correlation (r=0.908, p0.01) noted statistically compared with BMI and showed the high correlation noted statistically in a comparison with BIA (r=0.927, p0.01). Conclusion: It confirmed that the whole body percent fat presumed from the part bone density measurement showed the excel correlation compared with BIA and BMI and information is high. There is still no clear standard about the presumed whole body percent fat and it is difficult to evaluate the fat evaluation by the bone mineral density measurement. However, it is determined that the information offering which is more objective through the comparative study with the body percent fat which is very efficient and in that it can obtain till the information about a fat as well as diagnosis of the osteoporosis through the bone density checkup is measured by the afterward telegraph bone density checkup and is clinically useful is possible.

  • PDF

Analysis of 1,000 Cases of Abdominal Ultrasonography Performed by a Pediatrician (소아과 의사에 의해 시행된 복부 초음파 검사 1,000예에 대한 분석)

  • Bae, Sang-In;Park, Jae-Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.10 no.1
    • /
    • pp.28-35
    • /
    • 2007
  • Purpose: The aim of this study was to evaluate the clinical usefulness of ultrasound examination of children performed by a pediatrician. Methods: One thousand children who presented with symptoms of a gastrointestinal disorder and underwent abdominal ultrasound evaluation in the Department of Pediatrics, between January 2003 and June 2006, were included in this study. We analyzed the patient's medical records and ultrasound results retrospectively. Results: Among the 1,000 patients, 58.4% were male and 41.6% were female. The mean age of the patients was $4.7{\pm}4.0$ years. The main reasons for ultrasound were abdominal pain (43.9%), vomiting (17.3%), elevated liver enzymes (11.8%), and jaundice (9.8%). Abnormal ultrasound findings were present in 57.9% of cases. The major abnormal findings were mesenteric lymphadenitis (29.2%), fatty liver (12.1%), hepatitis (6.4%), hepatosplenomegaly (6.2%), and acute appendicitis (4.8%). The time interval between the initial medical evaluation and the ultrasound evaluation was within 24 hours in most cases (78.5%). The main findings in children with abdominal pain were mesenteric lymphadenitis (32.6%), fatty liver (5.9%), intussusception (2.7%), and acute appendicitis (2.7%). The main findings in children with vomiting were mesenteric lymphadenitis (12.7%), hypertrophic pyloric stenosis (10.4%), and acute appendicitis (3.5%). The major ultrasound findings in children with urinary tract diseases were hydronephrosis (45.4%), urolithiasis (21.5%) and cystic renal disease (18.1%). Conclusion: Ultrasound examination played an important role as a non-invasive and prompt screening examination for detection of abdominal diseases. Ultrasound was an important tool for pediatricians to determine timely information for patient management.

  • PDF

Clinical Significance of Segmental Parenchymal Excretion Delay on Tc-99m DISIDA Hepatobiliary Scan (Tc-99m DISIDA 간담도 신티그라피에서 간 실질의 분절형 배설지연의 임상적 의의)

  • Kang, Do-Young;Ryu, Jin-Sook;Moon, Dae-Hyuk;Lee, Sung-Koo;Kim, Myung-Hwan;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.2
    • /
    • pp.161-167
    • /
    • 1998
  • Purpose: Segmental parenchymal excretion delay on Tc-99m DISIDA scan is caused by intrahepatic bile duct obstruction. However, the diagnostic value for intrahepatic bile duct obstruction is unknown. We conducted this study to assess the positive predictive value of segmental excretion delay for the diagnosis of intrahepatic bile duct obstruction, and additional benefit over other noninvasive radiologic studies. Materials and Methods: The study population consisted of 43 patients (48 scans) who showed segmental parenchymal excretion delay on Tc-99m DISIDA scan. The results of abdominal CT or ultrasonography, which was done within 1 month of Tc-99m DISIDA scan, were compared with scintigraphic findings. Results: The etiology of segmental parenchymal excretion delay was determined by ERC or PTC in 31 scans, and follow-up studies in 13 scans. No causes were identified in 4 scans. The positive predictive value of segmental parenchymal excretion delay for intrahepatic bile ductobstruction was 92% (44/48). On the other hand, 13% (5/38) of CT and 28% (5/18) of ultrasonography were normal. In 18% (7138) of CT and 17% (3/18) of ultrasonography, only intraheipatic bile duct dilatation was noted without any diagnostic findings of intrahepatic bile duct obstruction. Conclusion: Segmental parenchymal excretion delay on Tc-99m DISIDA scan had a high positive predictive value for the diagnosis of intrahepatic bile duct obstruction. Tc-99m DISIDA scan may be useful for the diagnosis of intrahepatic bile duct obstruction, especially in patients with nondiagnostic CT or ultrasonography. The diagnostic usefulness need to be confirmed by further prospective studies.

  • PDF

Avascular Necrosis of Bone after Renal Transplantation - Prevalence and Usefulness of Bone SPECT - (신장 이식후에 발생한 무혈관성 골괴사 -발생 빈도 및 골 SPECT의 유용성에 관하여 -)

  • Choi, Yun-Young;Yang, Seoung-Oh;Ryu, Jin-Sook;Moon, Dae-Hyuk;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.504-510
    • /
    • 1995
  • Avascular necrosis(AVN) of bone can be resulted from various causes that distrub vascular supply to bone tissue, including steroid therapy after renal transplantation. In this study, we determine the prevalence of the avascular necrosis of bone after renal transplantation and compare the role of the bone scan, SPECT and MRI. In 301 patients with transplanted kidney, the prevalence of avascular necrosis was deter-mined clinically. Site of bone necrosis was evaluated by clinical symptom, bone scan, SPECT and MRI. Bone scan was done in all patients with AVN. Bone SPECT and MRI were done in six cases; and MRI was done in two cases. The prevalence of AVN was 3.3% (10/301), and the site of AVN was 16 femoral heads in 10 patients (bilateral: 60%) and bilateral calcaneal tuberosity in one patient. Bone scan showed typical AVN (cold area with surrounding hot uptake) in 13 lesions, only hot uptake in three lesions (including two calcaneal tuberosities), decreased uptake in one lesion, and normal in one lesion. Decreased uptake and normal lesion showed an equivacal cold area without surrounding hot uptake on SPECT. A symptomatic patient with positive bone SPECT showed normal finding on MRI. The prevalence of AVN of bone after renal transplantation was 3.3%, and whole body bone scan showed multiple bone involvement. Two symptomatic hip Joints without definite lesion on whole body bone scan or MRI showed cold defect on SPECT. Therefore, we conclude that bone SPECT should be perfomed in a symptomatic patient with negative bone scan or MRI in case with high risk of AVN after renal transplantation.

  • PDF

The Role of T1-201 Brain SPECT in the Differentiating Recurrent Tumor from Radiation Necrosis (뇌종양의 재발과 방사선 괴사의 감별을 위한 탈륨 SPECT의 역할)

  • Won, Kyoung-Sook;Ryu, Jin-Sook;Moon, Dae-Hyuk;Yang, Seoung-Oh;Lee, Hee-Kyung;Lee, Jung-Kyo;Kwun, Byung-Duk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.476-483
    • /
    • 1996
  • Following radiation therapy for brain tumors, patients often have clinical deterioration due to either radiation necrosis or recurrent tumor progression in the treatment field. The distinction between these entities is important but difficult clinically or even with CT or MRI. T1-201 has been known to accumulate in various tumors and be useful to grade, predict prognosis or detect recurrence of glioma. The aim of this study was to evaluate the usefulness of T1-201 SPECT in the differentiation of recurrent tumor from radiation necrosis. Of 67 patients who did T1-201 brain SPECT imaging with clinically suspected recurrent tumor or radiation necrosis, 20 patients underwent histopathological examination and constituted the study population. T1-201 uptake indices on T1-201 brain SPECT imaging rrere calculated and correlated with histopathological diagnosis. Of 20 patients, 15 were histopathologically confirmed as recurrent original tumor or malignant transformation of benign tumor and 5 were diagnosed as radiation necrosis. On T1-201 SPECT, 18 of 20 had T1-201 index above 2.5 which was regarded as positive indicator for the presence of tumor. Seventeen cases showed concordance, which consisted of 15 true positive and 2 true negative. Discordant 3 cases were all false positive. There was no case of false negative. The sensitivity, specificity, positive and negative predictive value of T1-201 SPECT were 100%, 40%, 83% and 100%. In conclusion, T1-201 brain SPECT is a sensitive diagnostic test in the detection of recurrent tumor following radiation therapy and is useful in the differentiation of recurrent tumor from radiation necrosis. Relatively low specificity should be evaluated further in larger number of patients in consideration of sampling error and referral bias for pathologic examination.

  • PDF

Usefulness of F-18 FDG PET/CT in Adrenal Incidentaloma: Differential Diagnosis of Adrenal Metastasis in Oncologic Patients (부신 우연종에서 F-18 FDG PET/CT의 유용성: 악성 종양 환자에서 부신 전이의 감별진단)

  • Lee, Hong-Je;Song, Bong-Il;Kang, Sung-Min;Jeong, Shin-Young;Seo, Ji-Hyoung;Lee, Sang-Woo;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.421-428
    • /
    • 2009
  • Purpose: We have evaluated characteristics of adrenal masses incidentally observed in nonenhanced F-18 FDG PET/CT of the oncologic patients and the diagnostic ability of F-18 FDG PET/CT to differentiate malignant from benign adrenal masses. Materials and Methods: Between Mar 2005 and Aug 2008, 75 oncologic patients (46 men, 29 women; mean age, $60.8{\pm}10.2$ years; range, 35-87 years) with 89 adrenal masses incidentally found in PET/CT were enrolled in this study. For quantitative analysis, size (cm), Hounsfield unit (HU), maximum standardized uptake value (SUVmax), SUVratio of all 89 adrenal masses were measured. SUVmax of the adrenal mass divided by SUVliver, which is SUVmax of the segment 8, was defined as SUVratio. The final diagnosis of adrenal masses was based on pathologic confirmation, radiologic evaluation (HU<0 : benign), and clinical decision. Results: Size, HU, SUVmax, and SUVratio were all significantly different between benign and malignant adrenal masses.(P < 0.05) And, SUVratio was the most accurate parameter. A cut-off value of 1.0 for SUVratio provided 90.9% sensitivity and 75.6% specificity. In small adrenal masses (1.5 cm or less), only SUVratio had statistically significant difference between benign and malignant adrenal masses. Similarly a cut-off value of 1.0 for SUVratio provided 80.0% sensitivity and 86.4% specificity. Conclusion: F-18 FDG PET/CT can offer more accurate information with quantitative analysis in differentiating malignant from benign adrenal masses incidentally observed in oncologic patients, compared to nonenhanced CT.

The Effects of Discrepancy in Reconstruction Algorithm between Patient Data and Normal Database in AutoQuant Evaluation: Focusing on Half-Time Scan Algorithm in Myocardial SPECT (심근 관류 스펙트에서 Half-Time Scan과 새로운 재구성법이 적용된 정상군 데이터를 기반으로 한 정량적 분석 결과의 차이 비교)

  • Lee, Hyung-Jin;Do, Yong-Ho;Cho, Seong-Wook;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.122-126
    • /
    • 2014
  • Purpose: The new reconstruction algorithms (NRA) provided by vendor aim to shorten the acquisition scan time. Whereas depending on the installed version AutoQuant program used for myocardial SPECT quantitative analysis did not contain the normal data that NRA is applied. Thus, the purpose of this paper is to compare the results according to AutoQuant versions in myocardial SPECT applied NRA and half-time scan (HT). Materials and Methods: Rest Tl and stress MIBI data of total 80 (40 men, 40 women) patients were gathered. Data were applied HT acquisition and ASTONISH (Philips) software which is NRA. Modified autoquant of SNUH and old version of AutoQuant (full-time scan) provided by company were compared. Comparison groups were classified as coronary artery disease (CAD), 24 hrs delay and almost normal patients who have a simple pain patient. Perfusion distribution aspect, summed stress score (SSS), summed rest score (SRS), extent and total perfusion deficit (TPD) of each 25 patient who have above diseases were compared and evaluated. Results: The case of CAD, when using re-edited AutoQuant (HT) SSS and SRS showed about 30% reduction (P<0.0001), Extent showed about 38% reduction and TPD showed about 30% reduction in the tendency (P<0.0001). In the score of the perfusion, especially on the part of infero-medium, infero-apical, lateral-medium and lateral-apical regions were the biggest change. The case of the 24 hrs delay patient SRS (P=0.042), Extent (P=0.018) and TPD (P=0.0024) showed about 13-18% reduction. And the case of simple pain patient, comparison of 4 results showed about 5-7% reduction. Conclusion: This study was started based on expectation that results could be affected by normal patient data. Normal patient data is possible to change by race and gender. It was proved that combination of new reconstruction algorithm for reducing scan time and analysis program according to scan protocol with NRA could also be affected to results. Clinical usefulness of gated myocardial SPECT is possibly increased if each hospital properly collects normal patient data for their scan acquisition protocol.

  • PDF

Detection of Brain Metastatses Using Limited Brain MR Imaging : Usefulness of Limited Contrast-Enhanced MR Imaging in Brain Metastasis (뇌전이암 진단을 위한 제한적 뇌 자기공명영상의 유용성에 관한 연구)

  • Kwon, Sun Jung;Lee, Yun Sun;An, Jin Yong;Park, Hee Sun;Jung, Sung Soo;Kim, Ju Ock;Kim, Jin Hwan;Song, Chang Joon;Kim, Sun Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.5
    • /
    • pp.499-505
    • /
    • 2003
  • Background : The brain is a common site of a metastasis in lung cancer patients. If left untreated, the patients succumb to progressive neurological deterioration with a lower survival rate than with other metastases sites. Contrast-enhanced MR imaging in the absence of symptoms or clinical signs is not recommended for identifying a cerebral metastasis in lung cancer patients because of management effectiveness. This pilot study was performed to estimate whether or not limited brain MR imaging, which has a lower cost, could be used to replace conventional brain MR imaging. Method : Between April 1999 and March 2001, 43 patients with a primary lung cancer and the others (breast cancer, stomach cancer, colon cancer, malignant melanoma etc), who had neurological symptoms and signs, were examined using conventional brain MR imaging to examine brain metastases. The control group involved four patients who had no evidence of brain metastases the sensitivity, specificity and correlation of limited brain MR imaging were compared with conventional brain MR imaging. Results : All the 43 patients who were examined with conventional brain MR imaging showed evidence of brain metastases, whereas limited brain MR imaging indicated that 42 patients had brain metastases(sensitivity=97.67%). One patient in whom limited brain MR imaging showed no brain metastasis had a metastasis in the cerebellum, as shown by the contrast-enhanced T1 weighted axial view using conventional brain MR imaging. The conventional brain MR imaging and the limited brain MI imaging of the 4 control patients both indicated no brain metastases (specificity=100 %). The Pearson Correlation of the two groups was 0.884(Confidence Interval : 99%) observed. Conclusion : Limited brain MR imaging can detect a brain metastasis with the same accuracy. In addition, it is cost-effective (229,000 won, 180$) compared to conventional brain MR imaging(529,000 won, 480$) when patients had neurological symptoms and signs or staging.