• 제목/요약/키워드: Clinical stress

검색결과 1,847건 처리시간 0.049초

한의(韓醫) 예방의학(豫防醫學)의 특징(特徵)에 관(關)한 문헌적(文獻的) 고찰(考察) (A Literal Study of Feature of the Preventive Medicine in Oriental Medical Science)

  • 이상운;이선동
    • 대한예방한의학회지
    • /
    • 제1권1호
    • /
    • pp.85-104
    • /
    • 1997
  • As the concern about health is increased, the importance of preventive medicine that prevent disease in advance to overcome boundary of disease remedy gets emphasized in the whole world. The fundamental thoughts of oriental medicine are the harmony between the human body and nature, the unified idea regarding mind in the same light with body, and the symmetry of the cosmo dual forces. And oriental medicine is a kind of study that has developed on the ground of prevention thought. from old days, it has been developed the preventive medicine at is called 'Yangseng(養生; recuperation)' etc. with the clinical medicine. The preventive medicine of oriental medicine was taking a serious of the first preventive medicine of an incurable disease thought and the prevention thought that belongs to the second and third preventive medicine is described through the whole oriental medicine. Also the clinical and preventive medicine to apply to the clinics have an in- separable relation. Therefore I inspected the part of the preventive medicine described in some oriental medicine books and studied the characteristics of preventive medicine of oriental medicine as follows; First, the preventive medicine of oriental medicine has the characteristics that is emphasized generally in the first preventive medicine and wholly it is composed in the system of the first, second and third preventive medicine. It has the presentative theory such as 'Jungkijonae sabulkaghan(正氣存內 邪不可干; If good energy is in body, a disease. dosen't occur)', 'Husajukpung Phijeyushi(虛邪賊風 避之有時; When e infectious disease like plague break out, they must avoid the place occurring the disease)', 'Chuninsangeung(天人相應; The harmony of nature and human)' etc.. This is intimately related to the incurable disease thought of the inside diameter and oriental medicine has pursued that. Second, due to the most prerequisite theory of disease production, the balanced condition of environment, the cause of a disease and host is called the health. As oriental medicine has the system of aetiology like that, we can see the host and environments are importance most of all. Namely we can think of the relation of host >> environment > the cause a disease Up to date Jungkijonae Sabulkaghan(正氣存內 邪不可干) that the most oriental medicine doctors have had a knowledge is not whole theory but a pan of oriental medicine science and it is included in oriental medicine theory to avoid infectious disease such as Husajukpung Phijeyushi(虛邪賊風 避之有時). Third, according to the natural result of the first and second contents, we can know that its characteristics stress the remedy without drugs. Because Jungkijonae Sabulkaghan(正氣存內 邪不可干), Husasukpung Phijeyushi(虛邪賊風 避之有時), and Chuninsangeung(天人相應) mean that they prevent disease in condition of freedom from ailment, We can prevent the disease production through the positive preventive methods such as exercise, spirit, food and innate prevention etc.. fourth, the preventive medicine of oriental medicine has developed with therapeutics and it contains all oriental medical methods such as host, environment, exercise, acupuncture and moxibustion, innate or postnatal methods. Also it is the general preventive medicine that has fundamental philosophy of oriental medicine; for examples, the unified idea, the harmony of nature and human, and the unity of mind and body. fifth, to develope the above scientific merit and special features, the preventive medicine of Oriental medicine must be objectified and reemergent stud? gets more and more essential from now on. Especially we need to have the scientific concern of Oriental medicine about the cause of a disease, environmental hygiene, industrial sanitation, and personal hygiene etc..

  • PDF

당뇨병 환자에서 심근관류 SPECT을 이용한 관동맥질환의 진단: 위험인자 분석 (Diagnosis of Coronary Artery Disease using Myocardial Perfusion SPECT in Patients with Diabetes Mellitus: Analysis of Risk Factors)

  • 서지형;강성민;배진호;정신영;이상우;유정수;안병철;이재태
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제40권3호
    • /
    • pp.155-162
    • /
    • 2006
  • 목적 : 당뇨병 환자에서는 관동맥질환의 이환율이 높고 무통성 심근경색과 심근허혈의 빈도가 높아 조기발견이 어렵다. 또한 진단될 당시에 이미 심각한 수준의 관동맥질환을 가지고 있는 경우가 많다. 본 연구에서는 Tc-99m MIBI 심근관류 SPECT을 이용하여 당뇨병 환자에서 관동맥질환의 빈도를 평가하고 전통적인 심장위험 인자들을 포함한 여러 임상시험인자들 중에서 진단이 필요한 고위험군 환자들을 예측할 수 있는 인자들을 알아보고자 하였다. 대상 및 방법 : 2000년 1월부터 2004년 7월 사이에 심근관류 SPECT 검사가 의뢰된 203명의 당뇨병환자(남 64명, 평균연령 $64.9{\pm}9.0$세)를 대상으로 하였다. 심장사망 및 비치명적 심근경색을 중증심장사건으로 정의하였고, 검사 후 60일 이후에 경피적 관동맥성형술이나 관동맥 우회수술을 시행한 정도의 심근허혈의 악화를 경증심장사건으로 정의하였다. 환자들은 운동 부하 (n=6) 혹은 adenosine (n=197) 부하 Tc-99m MIBI 심근관류 SPECT을 시행하였다. 이중검출기(ADAC, USA) 혹은 삼중검출기 감마카메라(PRISM 3000, Picker, USA)를 이용하여 SPECT 영상을 획득하였다. 결과: 심근관류 SPECT 결과 관동맥질환이 진단된 환자들은 58명으로 전체 대상 환자 중 28.6%였다. 총 11건의 중증심장사건, 즉 비치명적 심근경색이 발생하였고 10건의 경증심장사건이 관찰되었다. 전체 대상 당뇨병 환자들의 연간 심장사건 발생률은 1.1%였다. 임상인자들의 단변량 분석 결과, 전형적인 협심증상, 말초혈관병증, 다발성 말초신경병증, 그리고 안정시 심전도상 이상이 심장사건의 발생과 유의한 관련성이 있는 것으로 나타났다. 다변량 분석에서는 전형적인 협심증상, 말초혈관병증, 그리고 안정시 심전도상 이상만이 비치명적 심근경색 발생에 대한 독립적인 예측인자인 것으로 나타났다. SPECT 검사상 관류 이상 소견이 있었던 환자들에게서 중증 심장사건이 일어나는 빈도도 높았으나 심장사건의 독립적인 예측인자는 아니었다. 결론: 당뇨병 환자에서 관동맥질환의 빈도는 정상건강인들에 비해 높았다. 특히 남자, 20년 이상의 긴 당뇨병 이환 기간, 말초혈관병증, 다발성 말초신경병증, 또는 안정시 심전도 이상을 가지고 있는 환자들에서 유의하게 더 높은 빈도로 관동맥질환이 나타남을 알 수 있었다. 그리고 전형적인 협심증상, 말초혈관병증, 다발성 말초신경병증, 안정시 심전도 이상이 있는 환자들에서 이후 중증 심장사건이 발생할 위험이 더 큰 것으로 나타났다.

수부 다한증에서 흉부교감신경 절제술의 성적 (Clinical Outcomes of Thoracic Sympathicotomy for Palmar Hyperhidrosis)

  • 이장훈;이정철
    • Journal of Chest Surgery
    • /
    • 제41권1호
    • /
    • pp.89-94
    • /
    • 2008
  • 배경: 수부 다한증의 치료로 3번 늑골 위 교감신경 절제술이 널리 이용된다. 본 연구에서는 수부 다한증으로 3번 늑골 위 교감신경 절단술을 받은 환자들의 중장기 성적을 추적하여 환자의 만족도를 연구하고자 하였다. 대상 및 방법: 2001년 1월부터 2006년 12월까지 3번 늑골위 교감신경 절단술을 시행받은 환자 225명 중 의무기록 관찰과 전화 설문 조사가 가능한 환자 200명을 대상으로 하였다. 평균 추적기간은 51.7개월($11{\sim}80$개월)이었다. 수술 후 손에 땀이 나는 정도를 알기 위해 손이 너무 마른다(grade 1), 적당하다(grade 2), 땀이 나지만 술 전보다 감소했다(grade 3), 수술 전과 비슷하게 땀이 다시 난다(grade 4)로 나누어 조사하였다. 보상성 다한증의 발생과 일상생활에 불편이 있는지를 알아보기 위해 보상성 다한증이 없다(grade 0), 약간 있지만 생활에 불편은 없다(grade 1), 생활에 조금 불편을 느낀다(grade 2), 생활에 불편함이 크다(grade 3)로 나누어 조사하였다. 수술 후 만족도에 대해서는 매우 만족(very good), 만족(good), 보통(regular), 불만족(deficient)의 4가지로 나누어 조사하였다. 결과: 보상성 다한증이 발생한 군과 발생하지 않은 군 사이에 임상적 지표는 유의한 차이가 없었다. 보상성 다한증의 발생률은 83.5%였고 체간과 하지에 많은 분포를 보였다. 보상성 다한증의 정도는 환자의 body mass index와 유의한 관련이 있었고 계절과 주위 온도에 영향을 받으며 정신적 긴장이 보상성 다한증을 악화시키는 것으로 밝혀졌다. 결론: 수술 결과에 대한 만족도는 61.5%로 기대 이하의 만족도를 나타내었다. 술 후 만족도는 보상성 다한증의 발생과 정도에 밀접한 관계가 있는 것으로 나타나 보상성 다한증을 줄이는 것이 환자의 만족도를 높이는 방법이라 생각된다.표준 어음청력검사표의 완성등 적절한 조치가 이루어져야할 것으로 촉구되었다.사항의 응답재료를 검토한 바 있기에 보고하는 바이다.시도는 우리나라 광양만 내에 존재하는 해양 바이러스의 생태적 분포 연구를 다루는 첫 번째 실험으로 사료된다.탄산염암 지역은 Ca-$HCO_3$형, 혼펠스 지역은 Na-K형과 $CO_3+HCO_3$형이 우세한 것으로 나타났다. 본 연구를 통해 달천 폐광산 지역의 광미적재지에서 $Ca^{2+},\;Mg^{2+}$$SO_4^{2-}$ 성분이 지하수에 다량 용해되어 지하수의 주 흐름 방향에 위치한 기반암 지하수에 유입되었음을 알 수 있었다.tic monks could not wear. to express their deep faith. So the rules of the samgha has been distorted. The samgha has enlarged day by day as a great huge religious association. There are many different shapes of Kasaya. The Buddhist samgha need to establish a minute and rigid rules of Kasaya to order living of monks and to teach the moral and educational life to ordinary people. That book of rule is Vinaya pitaka(율장) . There are many kinds of Vinaya pitaka. This paper surveys the rules of Kasaya from Southern Vinaya pitaka(남전율장). This study will be the basic ground to research the Korean Buddhist

미만형 위암에서 임상병리학적 인자와 Hsp70, BAG1과 Raf-1 발현간의 상관성 (Correlation between Clinicopathology and Expression of HSP70, BAG1 and Raf-1 in Human Diffuse Type Gastric Carcinoma)

  • 정상봉;이현욱;정경태
    • 생명과학회지
    • /
    • 제26권1호
    • /
    • pp.101-108
    • /
    • 2016
  • 본 연구에서는 미만형 위암조직에서의 임상병리학적 인자와 HSP70, BAG1, Raf-1의 발현간의 상관관계를 평가하고자 하였다. Hsp70은 열충격단백질(heat shock protein)의 환경적 스트레스로부터 세포를 보호하는 분자생물학적 chaperone으로 작용하는 것뿐 아니라 anti-apoptotic 작용을 통하여 암세포의 생존과 전이를 촉진시키는 것으로 알려져 있다. Proto-oncogene의 일종인 Raf는 사람을 포함한 진핵세포의 생장에 관여하는 중요한 신호전달경로인 mitogen-activated protein kinase (MAPK)경로의 중심인자로서 다양한 암에서 그 발현이 증가한다고 알려져 있다. Bcl-2에 결합하여 세포사멸을 저해하는 것으로 처음 보고된 Bcl-2-associated athanogene-1 (BAG-1)은 다양한 암에서 그 발현이 증가된다고 보고되었다. 또한 BAG-1은 HSP70과 상호작용하여 Raf-1-ERK signal pathway와 cell growth를 조절하는 것으로 보고되었다. Hsp70의 발현은 임파절 전이가 있는 경우 24례(64.9%)에서 양성, 13례(35.1%)에서 음성을 보였으며, 임파절 전이가 없는 경우 6례(26.1%)에서 양성, 17례(73.9%)에서 음성을 보여 임파절의 전이가 있는 경우가 임파절 전이가 없는 경우에 비해 유의하게 높은 발현율을 보였다(p=0.007). N-stage에 따른 발현은 N-stage가 증가함에 따라 발현율이 유의하게 증가하였다(p=0.006). BAG1의발현은 전체 대상 환자 중 43례(71.7%)에서 양성, 17례(28.3%)에서 음성소견을 보였으며, 65세 미만에서 65세 이상에 비해 유의하게 높은 발현율을 보였다(p=0.035). RAF1의 경우 전체 대상 환자 중 45례(75.0%)에서 양성, 15례(25.0%)에서 음성소견을 보였으며, BAG1 양성환자에서 RAF1의 발현이 유의하게 증가 하였다(p=0.021). 본연구 결과 Hsp70은 종양의 진행과 상관성이 있을 것으로 생각되어지며, BAG1과 Raf-1은 미만형위 암의 진단적 마커로 유용할 것으로 사료된다.

치과용 레진 시멘트의 중합 수축률 특성에 관한 연구 (In vitro study of Polymerization shrinkage-strain kinetics of dental resin cements)

  • 김태훈;양재호;이재봉;한중석;김성훈
    • 대한치과보철학회지
    • /
    • 제48권1호
    • /
    • pp.55-60
    • /
    • 2010
  • 연구 목적: 치과용 레진시멘트의 중합 수축은 수복물이 치아에 정확하게 합착되는 것을 방해하고, 내부 응력의 원인이 되어 치아에 여러 문제점을 일으킬 수 있다. 이러한 임상적인 문제점을 줄이기 위해서 사용하는 치과용 레진시멘트의 중합 수축률에 대해 아는 것이 중요하다. 본 연구에서는 상업적으로 이용되고 있는 몇 가지 레진시멘트의 시간에 따른 중합 수축률을 측정, 서로 비교하고자 하였다. 연구 재료 및 방법: 3종류의 자가 중합형 레진시멘트(Fujicem, Superbond, M bond)와 3종류의 이원 중합형 레진시멘트(Maxcem, Panavia F, Variolink II) 별로 각각 5개의 시편을 이용하였다. 각 재료의 중합 수축률은 Bonded disk method를 이용하여 측정하였다. 안쪽 직경 16 mm, 두께 1 mm 의 동으로 제작된 링을 유리판 ($74\;mm\;{\times}\;25\;mm\;{\times}\;3\;mm$) 위의 중앙에 위치시켜 부착하고, 그 유리판 중앙에 실험 재료를 구 형태로 만들어 올리고, 다른 유리판으로 눌러서 원판 형태 (직경 8 mm, 두께 1 mm)의 시편을 제작하였다. 시편의 중합 수축률은 재료가 중합이 시작된 후 120분동안, $23^{\circ}C$에서 측정하였다. 시간에 따른 수축량에 대한 kinetics curve를얻고, 각 실험 재료의 수축률의 평균값 (%)과 표준편차를 구한 뒤, one-way ANOVA 및 Scheffe post hoc test를 유의수준 0.05 에서 처리하여 그 결과 값을 비교하였다. 결과: 1. 실험에 사용된 Fujicem, Maxcem, M bond, Panavia F, Superbond, Variolink II 은 중합이 시작 된 120 분 후의 중합 수축률이 각각 3.72%, 4.19%, 4.13%, 2.44%, 7.57%, 2.90%의 값을 보였다. 2. Panavia F가 중합 수축률이 가장 작았고, Superbond가 중합 수축률이 가장 컸다 (P<.05). 3. Maxcem 과 M Bond 간에는 유의한 차이가 없었다 (P>.05). 4. 6종류의 레진 시멘트에서 90% 이상의 대부분의 수축은 중합이 개시된 30분 내에 거의 일어났다. 결론: 자가 중합형 레진시멘트의 혼합 후 나타나는 중합 수축이 이원 중합형 레진시멘트보다 천천히 일어나지만, 혼합 120분 뒤의 중합 수축은 이원 중합형 레진 시멘트 보다 유의할 정도로 높았다. 치과용 레진시멘트의 중합 수축은 혼합한 후 30 분내에 대부분 일어난다.

조산아에서 발생하는 부신기능부전과 연관된 저혈압의 임상상 (Clinical Picture of Adrenal Insufficiency-associated Hypotension in Preterm Infants)

  • 최은진;손진아;이은희;이주영;이현주;정혜림;이진아;최창원;김이경;김한석;김병일;최중환
    • Neonatal Medicine
    • /
    • 제18권1호
    • /
    • pp.82-88
    • /
    • 2011
  • 목적: 본 연구에서는 부신기능부전과 연관된 저혈압의 임상적 특성과 hydrocortisone 투여에 대한 치료반응을 알아보고자 하였다. 방법: 2007년 1월 1일부터 2009년 8월 31일까지 분당서울대학교병원에서 출생하여 신생아집중치료실에 입원했던 재태주령 32주 미만의 미숙아 158명 중 미숙아 부신기능부전과 연관된 저혈압이 발생하였던 12명의 환아를 대상으로 하였고 이들의 임상적 특성과 hydrocortisone 투여 전과 후의 평균혈압, 소변량, 혈청 전해질 검사 소견을 비교하였다. 결과: 환아의 재태주령은 27.8${\pm}$2.5주, 출생체중은 1,110${\pm}$307g이었고 부신기능부전과 연관된 저혈압이 발생한 시기는 생후19${\pm}$7일, 월경 후 주령으로는 30.6${\pm}$2.4주이었고 당시 체중은 1,285${\pm}$365 g이었다. Dopamine 투여에도 저혈압이 발생한 미숙아는 hydrocortisone을 4.0 mg/kg/day의 스트레스 용량으로 시작해 2.2${\pm}$0.7일간 유지 후 감량하였으며 hydrocortisone 투여 전의 혈청 cortisol 농도는 11.6${\pm}$4.1 mg/dL이었다. Hydrocortisone 투여 당시와 2, 4, 6시간 후의 평균혈압은 25.0${\pm}$5.4 mmHg에서 35.0${\pm}$5.3 mmHg, 38.3${\pm}$8.0 mmHg 그리고 41.9${\pm}$6.5 mmHg 로 증가되다가 그 후로는 안정적으로 유지되었고 소변량도 hydrocortisone 투여 전에 0.9${\pm}$0.6 mL/kg/hr에서 치료 6시간 후 4.1${\pm}$3.4 mL/kg/hr로 증가되었다. 치료시작당시와 12시간 후의 dopamine 용량은 11.0${\pm}$2.9 ${\mu}g$/kg/min에서 8.0${\pm}$2.3 $\mu$g/kg/min로 감량되었고 24시간 후에는 5.5${\pm}$3.4 ${\mu}g$/kg/min까지 감량되었다. 혈청 $Na^+$ 농도는 hydrocortisone 투여 전 130${\pm}$4 mEq/L에서 투여 12시간 후 136${\pm}$4mEq/L로 증가되었고 혈청 $K^+$ 농도는 hydrocortisone 투여 전6.1${\pm}$1.1 mEq/L에서 투여 12시간 후 4.6${\pm}$0.6 mEq/L로 감소하였다. 결론: 미숙아에서 부신기능부전과 연관된 저혈압이 발생한 경우 hydrocortisone의 투여는 신속히 혈압을 상승시키고 소변량을 증가시켰으며 전해질 농도를 정상화시켰다.

하악과두흡수 환자의 임상적 평가 및 악안면 골격형태에 대한 연구 (Clinical Assessment and Cephalometric Characteristics in Patients with Condylar Resorption)

  • 구선주;김균요;허윤경;채종문;최재갑
    • Journal of Oral Medicine and Pain
    • /
    • 제34권1호
    • /
    • pp.91-102
    • /
    • 2009
  • 2006년 한 해 동안 경북대학교 구강내과에 측두하악장애를 주소로 내원한 전체 환자 중에 파노라마 방사선 사진 상에서 인정될만한 하악과두흡수가 관찰된 환자를 대상으로 측모두부방사선 사진을 촬영하였으며, 측두하악장애의 임상적 평가와 악안면 골격형태를 분석하여 다음과 같은 결론을 얻었다. 1. 임상적 평가 1) 측두하악장애를 주소로 내원한 총 환자 수는 2419명 이었고 그중 224명 약 9.3%가 과두흡수를 나타내었다. 과두흡수가 있는 환자군 중 여자는 183명(81.7%)이고 남자는 41명(18.3%)으로 여자에서 월등히 많이 유발되었다. 환자의 연령은 12세에서 70세에 걸쳐 분포되었으며 평균 연령은 30.6세였다. 연령분포는 10대가 26.3%(59명), 20대가 34.8%(78명), 30대가 13.8%(31명), 40대가 11.2%(25명), 50대가 7.1%(16명), 60대가 6.3%(14명), 그리고 70대가 0.4%(1명)로 나타났다. 2) 과두흡수 부위의 통증을 호소한 경우는 145명, 통증을 호소하지 않은 경우가 79명이었다. 3) 과두흡수 환자 중 이갈이 습관을 53명, 이깨물기 습관은 80명이 호소하였으며, 다른 기타 습관들을 보고한 경우가 204명이었다. 4) 과두흡수 부위의 통증을 호소한 환자의 치료기간은 1개월 미만이 81명으로 전체적으로 치료기간이 짧게 나타났다. 2. 악안면 골격 형태 평가 전체 과두흡수 환자 224명중 18세 이상의 186명(여자 155명, 남자 31명)만이 한국 성인 정상교합자의 측모두부방사선사진 계측연구 결과와 비교하였다. 1) SNA, SNB는 남녀 모두에서 유의한 작은 값을 나타냈고, ANB항목에서는 남자는 평균 3.57 여자는 5.05으로 여자 환자에서 큰 값을 보여 남자에 비해 하악이 더 후퇴되어 있음을 알 수 있다. 2) 남녀 모두 SN-GoMe, FMA의 각도가 과두흡수 환자에서 유의하게 상당히 커져 있음을 보였다. FMA는 남자는 평균 30.44, 여자는 31.69로 여자에서 수직적 성장이 더 크게 나타났다. 3) 총후안면고경(posterior facial height)이 과두흡수 군에서 모두 작은 것이 특징으로 보였으며, 총전안면고경(Anterior facial height)은 과두흡수 환자군에서 남녀 모두 정상군에 비해 차이가 없었다. 저자의 연구에서 얻어진 결과에 의해 하악과두흡수는 정형외과적으로 퇴행성관절염과는 달리 젊은 여성에서 유병률이 높았으며 이는 남성보다 여성에서 수직적 골격 성장 양상으로 인해 하악과두 전방부의 압축응력을 증가시키는 위험요인을 가진 환자에서 발현이 높은 것으로 생각되며 그리고 노년층보다는 젊은 사람에서 이상기능활동으로 인한 부하의 증가 때문이라 생각한다. 하악과두흡수를 보이는 환자들의 치료기간이 대체적으로 짧으며, 나이가 증가함에 따라 내원하는 환자수가 증가하지 않는다는 것은 이 질환이 자기한정적임을 알 수 있고, 생리적 내성 범위 이상의 부하가 가해져 발생한 하악과두의 재형성 과정으로 생각한다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

구안와사(口眼喎斜)에 대한 한의(韓醫) 및 한(韓)·서의(西醫) 협진(協診) 치료(治療)의 임상(臨床) 관찰(觀察) (Comparative Clinical Study between Oriental Medicine and Oriental-western Medicine Treatment on Facial Nerve Paralysis)

  • 강미정;김기현;황현서
    • Journal of Acupuncture Research
    • /
    • 제17권1호
    • /
    • pp.55-66
    • /
    • 2000
  • The following results have been obtaind after examing 72patients with facial paralysis who were hospitalzed and treated through the time period of December 1st, 1996 to November 30th, 1999 at the Department of Acupuncture and Moxibustion of Seoul Oriental Medicine, Kyungwon University. During the examination, those 72 patients were divided into two groups, and One group was treated by oriental-western treatment, the other group was treated by oriental treatment. Oriental treatments were acupuncture and moxibustion, herb medicine, physical treatment and hygienic treatment. The one of main western treatments is steroid therapy. The results were obtained as follows : 1. In regard to signs at the first medical examination, lacrimation was showed highest number and facial paralysis, dysgeusia, hyperacusis were showed in numerical order. 2. In regard to prescription of oriental herb medicine, Kamissangbotang(加味雙補湯) was prescribed in greatest numbers and Boyangwhanotang(補陽還五湯), Kamiboiktang(加味補益湯), Ligigepungtang(理氣祛風湯) were prescribed in numerical order. 3. In regard to treatment number, 10~19 times for treatment was showed highest number and 1~9 times, 20~29 times, 40~49 times were showed in numerical order . 4. In regard to mean treatment times about injury region and main sign, the effect of oriental-western treatment was showed as follows: lacrimal gland disorder, hyperacusis, dysgeusia, facial paralysis were treated for 15.1, 27, 13.2 and 21.4 times, repectively. The effect of oriental treatment was showed as follows: lacrimal gland disorder, hyperacusis, dysgeusia, facial paralysis were treated for 34.8, 22.1, 33.8 and 16.3 times, respectively. 5. In regard ta the effect of treatment about injury region and main sign, oriental-western treatment was showed as follows: cases of lacrimal gland disorder were showed 1 of excellent case, 1 of fair case, 5 of good cases. In hyperacusis patients, there was showed 1 of fair case. In dysgeusia patients, there was showed 1 of excellent case, 3 of fair cases, 1 of good case. In facial paralysis, there were showed 5 of fair cases. Oriental treatment was showed as follows: In lacrimal gland disorder, the excellent were 4 cases, the fair were 10 cases, the good were 3 cases and the poor were 4 cases, In hyperacusis, the fair were 5 cases, the poor 2 cases. In dysgeusia, the excellent were 4 cases, the fair were 1 case, the good were 1 case and the poor was 1 case, In facial paralysis, the excellent were 9 cases, the fair were 4 cases, the good 3 cases and the poor were 3 cases. 6. The effect of total treatment was as follows: 30 cases were showed fair effect, 19 cases were showed excellent effect, 13 cases were showed good effect and 10 cases were showed poor effect. 7. In regard to attack factor, overlabour was showed highest number and wind-cold, mental stress, trauma, ear disease, common cold, dental diseae, reason unknwon were showed in numerical order. 8. In regard to premonitory symptoms, non significant symptoms were in 38 cases, the pain of peri-stylomastoid region were in 38 cases and headache, dysaesthesia of periorbit, dysgeusia, stomatitis, eyelid tic were showed in numerical order. 9. In regard to sex, male were 33 cases and female were 39 cases. The distribution of age was disclosed that thirty, forty, fifty, seventy, sixty, twenty and below twenty years were revealed in turn. Sex and paralytic side were showed as follows: male-left were 15 cases, male-right were 18 cases, female-left were 19 cases and female-right were 19 cases. In regard to attack frequence in month, March was showed highest number and January, April, May, August, October, etc were showed in numerical order. In regard to attack frequence in season, spring was showed highest number and winter, summer, fall were showed in numerical order, but attack frequence between four seasons wasn't showed significant difference.

  • PDF