• Title/Summary/Keyword: Clinical performance examination

Search Result 167, Processing Time 0.031 seconds

A Phantom Study for the Optimal Low-dose Protocol in Chest Computed Tomography Examination (흉부 전산화단층촬영검사를 위한 최적의 저선량 프로토콜에 관한 팬텀연구)

  • Kim, Young-Keun;Yang, Sook;Wang, Tae-uk;Kim, Eun-Hye
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.101-107
    • /
    • 2021
  • The purpose of this study was to evaluate optimal CT scan parameters to minimize patient dose to the irradiation and maintain satisfactory image quality in low-dose chest computed tomography (CT) scans. In a chest anthropomorphic phantom, chest CT scans were performed at different kVp and mA within reference of 3.4mGy in volume CT Dose Index (CTDIvol). The following quantitative parameters had been statistically evaluated: image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM). Nine radiographers conducted the blind test to select the optimal kVp-mA combination. Results indicated that the kVp-mA combination of 80kVp-90mA, 100kVp-50mA, 120kVp-30mA and 140kVp-30mA were obtained high SNR and CNR. The 120kVp-30mA combination offered good compromise in the FOM, which showed the quality and dose performance. In the blind test, an image of 80kVp-90mA obtained a high score with 4.7 points, and 120kVp-10mA or 140kVp-10mA with a low tube current were observed severe noise and poor image quality, thus resulting in decreased diagnostic accuracy. On the other hand, in the combination of high kVp and high mA(140kVp-90mA), the image quality was improved, but the radiation dose was also increased. the FOM value of 140kVp-90mA was lower than 120kVp-30mA. The application of appropriate scan parameters in low-dose chest CT scans produced satisfactory results in dose and image quality for the accuracy of the clinical diagnosis.

Intraosseous line insertion education effectiveness for pediatric and emergency medicine residents (소아과와 응급의학과 전공의를 대상으로 한 골강내 주사 실습 교육의 효과 분석)

  • Lee, Jung Woo;Seo, Jun Seok;Kim, Do Kyun;Lee, Ji Sook;Kim, Seonguk;Ryu, Jeong-Min;Kwak, Young Ho
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.10
    • /
    • pp.1058-1064
    • /
    • 2008
  • Purpose : This study aimed to assess current knowledge of and training experiences with the intraosseous (IO) line among emergency medicine (EM) and pediatric residents who care for critically ill children and to evaluate the educational effectiveness of the IO line workshop. Methods : During May and June 2008, a workshops on IO line insertion was held for EM and pediatric residents. The workshop comprised a 45-min lecture and a 15-min hands-on session. A semi-drill type EZ-IO machine was used for education. Self-assessment questionnaires gauged residents knowledge of and experiences with IO line insertion or bone marrow (BM) examination and their confidence with IO line insertion before and after the workshop. Performance tests were completed for skill evaluation. Results : Forty-five pediatric residents and 22 EM residents participated in the workshop. The pre-educational questionnaire revealed that EM residents had more educational experience in IO line insertion than pediatric residents (P<0.001), while pediatric residents reported more experience in BM examination (P<0.001). The post-educational questionnaire showed a statistically significant higher percentage of correct answers (P<0.001). Although the pediatric residents inserted an IO line more quickly (P=0.001), most residents (88.7%) succeeded in IO line insertion on their first attempt; there was no difference in the groups success rates. Both groups showed higher confidence in performing IO line insertion after training (P<0.001). Conclusion : Observed educational effectiveness in both knowledge and confidence of IO line insertion skill suggest educational opportunities for pediatric and EM residents should be increased.

The effects of out of hospital ACLS simulation training on the paramedic's duty ability (구급대원의 전문심장소생술 시뮬레이션훈련이 직무수행융합능력에 미치는 영향)

  • Park, Yoo-Na;Cho, Byung-Jun;Kim, Gyoung-Young
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.4
    • /
    • pp.99-106
    • /
    • 2019
  • The purpose of this study is to analyze the effects of the simulation-based professional cardiac resuscitation training on the performance of professional cardiac resuscitation performed by paramedics in the pre-hospital stage and to provide basic data for effective cardiac resuscitation. This study is an experimental study of the design before and after the control of non-equality. The subjects of this study were 16 newly recruited paramedics from K firefighting school. The simulation training program and evaluation papers used as the evaluation tool were reviewed and commented by 6 ACLS simulation experts (2 emergency medical doctor, 2 emergency medical professors, 2 KALS instructors)Respectively. The training consisted of 30 minutes of theory and 150 minutes of practical training. The lecturer first demonstrated for 5 minutes, and after training by individual debriefing after individual training, individual and team education was conducted The evaluation scale was given a 5 - point Likert scale. The SPSS 22.0 program for Windows was used. The general characteristics of the subjects were analyzed for frequency, the examination of homogeneity between the experimental group and the control group wasfulfilled by t test, and the difference test between the groups of the two groups was performed using the paired t-test. The homogeneity test was able to confirm the homogeneity between experimental group and control group. In the evaluation of six ACLS techniques, it was proven that the experimental group that received the simulation training had better performance in all aspects than the non - training control group. The following are the technical items to be performed. 1. Electrocardiogram 2. Specialized instrument 3. Treatment of fluid 4. Leadership and teamwork 5. Medical guidance 6. Evaluation during transfer. It was proved that paramedics who received simulation training were improved on their job performance ability than general lecture and training group. Therefore, if simulation training and education are applied to a student in the synthetic course or an emergency resident who is engaged in clinical practice, he / she will be able to perform his / her duties more proficiently. It is expected that emergency services provided to patients with cardiac arrest will be improved.

Reduction of Injection Dose in 18F-FDG Fusion PET (PET-CT 검사에서 18F-FDG 투여량 감소에 대한 고찰)

  • Kim, Jong-Pil;Kim, Jae-Il;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.17-21
    • /
    • 2014
  • Purpose With the recent rise of social issue regarding radiation exposure, attention to medical radiation use has been placed under a great spotlight. During PET-CT examination, generally about 40% more of $^{18}F$-FDG is used than EANM recommendation. While maintaining the diagnostic test result, we hope to find optimal injection dose to minimize the $^{18}F$-FDG in patients by utilizing the latest PET-CT scanner which is equiped with the newest technology. Materials and Methods During this experiment, the Biograph Truepoint 40 (siemens, USA) installed in 2007 and mCT 64 (siemens, USA) installed in 2011 were used and evaluated NECR (noise-equivalent counting rate) by using a scatter phantom. For the image quality evaluation of each scanner, we injected 3.7, 4.44 and 5.18 MBq/kg of $^{18}F$-FDG in NEMA IEC Body Phantom and also evaluated SNR between two scanners by using the data acquired at 60, 70, 80, 90, 100, 110 and 120 sec per bed. For the clinical evaluation, actual data of patients who were injected $^{18}F$-FDG 3.7, 4.44, 5.18 MBq/kg were used to compare SNR and draw a final result. Results As a result, mCT 64 peak NECR value was 1.65e+005, which is 10% higher than Turepoint 40. SNR values using the IEC body phantom was 17.9%, 17.4% and 17.1% higher in $^{18}F$-FDG 3.7 MBq/kg, 4.44 MBq/kg and 5.18 MBq/kg. In clinical patients, SNR values of the image mCT 64 was 16.5, which is 25% higher than Turepoint 40 scanner. Conclusion To draw a conclusion from the test result of this experiment, the same quality of SNR could be attained even with 10% reduced injection dose, if when the duration is extended by 10 sec/bed. This optimal result was possible due to enhanced equipment. The NECR (one of the equipment's performance assessment criteria for the scanner) increased by 10% and the SNR (one of the image quality assessment criteria) also increased by 17.5%. Therefore, we can expect to reduce the injection dose without deterioration of image quality. In consequence, it will also help to decrease the patient's anxiety of the radiation exposure.

  • PDF

A Case of Childhood Obstructive Sleep Apnea Syndrome with Co-morbid Attention Deficit Hyperactivity Disorder Treated with Continuous Positive Airway Pressure Treatment (지속적(持續的) 상기도(上氣道) 양압술(陽壓術)을 시행(施行)하여 치료효과(治療效果)를 본 주의력(注意力) 결핍(缺乏).과잉(過剩) 운동장애(運動障碍)를 동반(同伴)한 소아기(小兒基) 폐쇄성(閉鎖性) 수면무호흡증(睡眠無呼吸症) 1례(例))

  • Sohn, Chang-Ho;Shin, Min-Sup;Hong, Kang-E;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.3 no.1
    • /
    • pp.85-95
    • /
    • 1996
  • Obstructive sleep apnea syndrome(OSAS) in childhood is unique and different n-om that in adulthood in several aspects, including pathophysiology, clinical features, diagnostic criteria, complications, management, and prognosis. Characteristic features of childhood OSAS in comparison with the adult form are the variety of severe complications such as developmental delay, more prominent behavioral and cognitive impairments, vivid cardiovascular symptoms, and increased death risk, warranting a special attention to the possible diagnosis of OSAS in children who snore. However, the childhood OSAS is often neglected and unrecognized. We, therefore, report a case of very severe OSAS in a 5-year-old boy who was sucessfully treated with continuous positive airway pressure(CPAP) treatment. Interestingly, the patient was comor-bid with the attention deficit hyperactivity disorder. Prior to the initial visit to us, adenotonsillectomy had been done at the age of 4 with no significant improvement of apneic symptoms and heavy snoring. On the initial diagnostic procedures, marked degree of snoring was audible even in the daytime wake state and the patient was observed to be very hyperactive. Increased pulmonary vascularity with borderline cardiomegaly was noted on chest X-ray. The baseline polysomnography revealed that the patient was very sleep-apneic and snored very heavily, with the respiratory disturbance index(RDI) of 46.9 per hour of sleep, the mean SaO2 of 78.8%, and the lowest SaO2 of 40.0%(the lowest detectable oxygen level by the applied oxymeter). The second night polysomnography was done for CPAP titration and the optimal pressure turned out to be $8.0\;cmH_2O$. The applied CPAP treatment was well tolerated by the patient and was found to be very effective in alleviating heavy snoring and severe repetitive sleep apneas. After 18 months of the CPAP treatment, the patient was followed up with nocturnal polysomnography(baseline and CPAP nights) and clinical examination. Sleep apneas were still present without CPAP on the baseline night. However, the severity of OSAS was significantly decreased(RDI of 15.7, mean SaO2 of 96.2%, and the lowest SaO2 of 83.0%), compared to the initial polysomnographic findings before initiation of long-term CPAP treatment. Wechsler intelligence tests done before and after the CPAP treatment were compared with each other and surprising improvement of intelligence(total 9 points, performance 16 points) was noted. Clinically he was found to be markedly improved in his attention deficit hyperactive behavior after CPAP treatment, but with minimal change of TOVA(test of variables of attention) scores except conversion of reaction time score into normal range. On the chest X-ray taken after 18 months of CPAP application, the initial cardiopulmonary abnormalities were not found at all. We found that the CPAP treatment in a young child is very effective, safe, and well-tolerated and also improves the co-morbid attention deficit hyperactive symptoms. Overall, the growth and development of the child has been facilitated with the long-term use of CPAP. Cardiovascular complications induced by OSAS have been also normalized with CPAP treatment. We suggest that early diagnosis and active treatment intervention of OSAS in children are crucial in preventing and ameliorating possible serious complications caused by repetitive sleep apneas and consequent hypoxic damage during sleep.

  • PDF

The Radiation Therapy for Spinal Cord Compression in Hematologic Malignancy (혈암에서 발생한 척추압박증상의 방사선 치료)

  • Kim In Ah;Choi Ihl Bohng;Chung Su Mi;Kang Ki Mun;Kay Chul Seong;Choi Byung Ok;Jang Ji Young;Shinn Kyung Sub;Kim Chun Choo
    • Radiation Oncology Journal
    • /
    • v.12 no.3
    • /
    • pp.393-399
    • /
    • 1994
  • Spinal cord compression, an oncologic emergency, is a rare complication of hematologic malignancy Our experience was obtained with a series 32 Patients following retrospective analysis for assessing the role of radiation therapy and identifying the prognostic factors affecting on treatment outcome. Diagnosis was usually made by means of radiologic study such as myelography or computerized tomography (CT) or magnetic resonance imaging (MRI) and neurologic examination. Five cases were diagnosed by subjective symptom only with high index of suspicion. In 31 cases, the treatment consisted in radiation therapy alone and the remained one patient had laminectomy before radiation therapy because of diagnostic doubts. Total treatment doses ranged from 800 cGy to 4000 cGy with median of 2000 cGy. Initially large fraction size more than 250 cGy were used in 13 patients with rapidly progressed neurologic deficit. The clinical parameters considered in evaluating the response to treatment were backache, motor-sensory performance and sphincter function. Half of all patients showed good response. Partial response and no response were noted in $37.5\%$ and $12.5\%$, respectively. Our results showed higher response rate than those of other solid tumor series. The degree of neurologic deficit at that time of diagnosis was the most important predictor of treatment outcome. The elapsed time from development of symptoms to start of treatment was significantly affected on the outcome. But histology of primary tumor total dose and use of initial large fraction size were not significantly affect on the outcome. These results confirmed the value of early diagnosis and treatment especially in radiosensitive hematologic malignancy.

  • PDF

Applicability of American and European Spirometry Repeatability Criteria to Korean Adults (한국 성인을 대상으로 한 미국 및 유럽 폐활량 검사 재현성 기준의 유용성)

  • Park, Byung Hoon;Park, Moo Suk;Jung, Woo Young;Byun, Min Kwang;Park, Seon Cheol;Shin, Sang Yun;Jeon, Han Ho;Jung, Kyung Soo;Moon, Ji Ae;Kim, Se Kyu;Chang, Joon;Kim, Sung Kyu;Ahn, Song Vogue;Oh, Yeon-Mok;Lee, Sang Do;Kim, Young Sam
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.5
    • /
    • pp.405-411
    • /
    • 2007
  • Background: The objective of this study was to evaluate the clinical applicability of the repeatability criteria recommended by the American Thoracic Society/European Respiratory Society (ATS/ERS) spirometry guidelines and to determine which factors affect the repeatability of spirometry in Korean adults. Methods: We reviewed the spirometry data of 4,663 Korean adults from the Korean National Health and Nutritional Examination Survey (KNHANES) Chronic Obstructive Pulmonary Disease Cohort (COPD cohort) and the Community-based Cohort Study VI-Fishing village/Islands (community cohort). We measured the anthropometric factors and differences between the highest and second-highest FVC (dFVC) and $FEV_1$ ($dFEV_1$) from prebronchodilator spirometry. Analyses included the distribution of dFVC and $dFEV_1$, comparison of the values meeting the 1994 ATS repeatability criteria with the values meeting the 2005 ATS/ERS repeatability criteria, and the performance of linear regression for evaluating the influence of subject characteristics and the change of criteria on the spiro-metric variability. Results: About 95% of subjects were able to reproduce FVC and $FEV_1$ within 150 ml. The KNHANES based on the 1994 ATS guidelines showed poorer repeatability than the COPD cohort and community cohort based on the 2005 ATS/ERS guidelines. Demographic and anthropometric factors had little effect on repeatability, explaining only 0.5 to 3%. Conclusion: We conclude that the new spirometry repeatability criteria recommended by the 2005 ATS/ERS guidelines is also applicable to Korean adults. The repeatability of spirometry depends little on individual characteristics when an experienced technician performs testing. Therefore, we suggest that sustained efforts for public awareness of new repeatability criteria, quality control of spirograms, and education of personnel are needed for reliable spirometric results.