• Title/Summary/Keyword: Clinical ECG

Search Result 171, Processing Time 0.033 seconds

Using the X-ray Image, Augmented Reality based electrocardiogram measurement system Development (X-ray 이미지를 활용한 증강현실 기반 심전도 측정시스템 개발)

  • Lee, Kwang-In;Jang, Jin-Soo;Lee, Tae-Ro
    • Journal of Digital Convergence
    • /
    • v.14 no.9
    • /
    • pp.331-339
    • /
    • 2016
  • Chronic diseases are increasing nowadays as daily habits changed due to economic growth. Among chronic diseases, heart cerebrovascular disease is one of the major causes of death in South Korea that accounts for approximately 20% of mortality. Tests to measure anomaly of the heart is ECG tests, which measures and analyzes the electrical heart activity. Any mistakes in lead attachment location critically affects ECG testings, and statistical facts showed that only 2.8% of the nurses properly located leads to patients. As a solution, this paper proposes a system based on a projection-based augmented reality technology to generate X-ray images to the patient's chest to point out exact attachment locations of ECG leads. Evaluation comparison results showed a 2.6 cm difference between the conventional system and the proposed system. ECG test results also showed significant signal differences between the systems in leads V1, V2, and V3. The ECG measured accurately by the proposed system would help greatly in patient management and clinical decisions of clinicians.

Variant angina diagnosed on pre-hospital 12-lead electrocardiogram: A case report (병원 전 12-Lead ECG 측정을 통해 진단된 이형성 협심증 1례)

  • Kim, Ji-Won;Ki, Eunyoung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.25 no.1
    • /
    • pp.243-249
    • /
    • 2021
  • A decrease in coronary blood flow leads to an imbalance between the supply of oxygen to the myocardium and its demand, and reversible or irreversible damage to the myocardium could occur depending on the severity of the resultant ischemia and the duration of the imbalance. This imbalance results in a cascade of ischemic reactions in the following order: metabolic abnormalities, diastolic dysfunction, systolic dysfunction, and electrocardiogram changes. Variant angina is caused by the closure of the coronary artery due to reversible coronary artery spasm, resulting in myocardial ischemia and subsequent chest pain as a clinical symptom. Variant angina may be observed as ST segment elevation in electrocardiogram measured when present in chest pain. However, 12-lead electrocardiogram performed after the patient's chest pain resolves does not help in the diagnosis. Since the duration of chest pain appears to be <15 minutes, it is important to perform the 12-lead electrocardiogram when clinical symptoms are present. If nitroglycerin is administered without performing 12-lead electrocardiogram by 119 pre-hospital paramedics, the chest pain would be resolved, making it impossible to identify changes in the ST segment. Before administration of nitroglycerin, changes in the ST segment must be recorded by performing 12-lead electrocardiogram.

Assessment of covariate-effect of sleeping behavior on heart rate variability during a clinical trial (임상시험 중 수면행위가 심박변이도에 미치는 영향 분석)

  • Lee, Jeon;Oh, Dal-Seok;Lee, Hae-Jung;Choi, Sun-Mi;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.3
    • /
    • pp.97-103
    • /
    • 2007
  • The object of this study is to evaluate confounding effect of sleeping behavior on heart rate variability (HRV) in healthy volunteers during a randomized clinical trial. From 6 healthy volunteer, we acquired circadian electrocardiography(ECG) with a Holter monitoring device(DigiTrak Plus, Philips). The compatible analytical program, Zymed, was used for calculation of RR intervals of 24h ECG signal. Then, we generated HRV signals and calculated 9 HRV parameters in time domain and frequency domain for every 30 minute with Matlab 6.x software. We also encoded participants' activities as follows; stable condition(1), sleeping behavior(2), eating behavior(3), and undefined condition(4). Using SPSS 12.0, we tested if there was any difference between HRV parameters of day-time and night-time and between those of a subject in stable condition and in sleeping behavior. As a result, one of the most important parameter-LF/HF ratio, which indicates the autonomic balance between sympathetic and parasympathetic nervous systems, as same the other parameters, showed large inter-individual variations in circadian profiles. And, the mean LF/HF ratio of each participant was different between in stable condition and in sleeping behavior (p<.05). Consequently, the effect of sleeping behavior must be considered when one or more of HRV parameters, especially LF/HF ratio, are used as assessment index in clinical studies.

  • PDF

Prognostic Value of Inferior Shift of P wave Axis after Catheter Ablation for Longstanding Persistent Atrial Fibrillation based on Dallas Lesion Set Including Anterior Line

  • Shin, Dong Geum;Kim, Tae-Hoon;Jeong, Hyunmin;Kim, Alexander;Uhm, Jae-Sun;Joung, Boyoung;Lee, Moon-Hyoung;Hwang, Chun;Pak, Hui-Nam
    • International Journal of Arrhythmia
    • /
    • 제18권2호
    • /
    • pp.66-76
    • /
    • 2017
  • Background and Objectives: Although an anterior linear ablation is an effective lesion set in radiofrequency catheter ablation (RFCA) for longstanding persistent atrial fibrillation (L-PeAF), its durability for bidirectional block (BDB) is only about 60% at repeat procedure. We hypothesized that changes in electrocardiogram (ECG) may predict an anterior line block state and the clinical outcome of L-PeAF ablation. Subjects and Methods: We studied 304 L-PeAF patients (77% male, $60{\pm}10yrs$), who consistently underwent RFCA Dallas lesion set (circumferential pulmonary vein isolation, posterior box lesion, and anterior line) protocol with subsequent comparison of pre-procedural and post-procedural P wave axes, and one year follow-up (n=205) sinus rhythm (SR) ECGs. Results: 1. P wave axis shifted inferiorly at immediate post-procedure (p<0.001), and was independently correlated with BDB of anterior line (${\ss}=10.4$, 95% confidence interval [CI] 2.79-17.94, p=0.008). 2. The degree of post-procedural inferior shift of P wave axis did not reflect clinical recurrence within one-year (n=205, p=0.923), potentially due to conduction recovery of an anterior line. However, among 160 patients without clinical recurrence within one-year, P wave axis at one-year ECG was independently associated with very late recurrence of AF after one-year (n=160, hazard ratio [HR] 0.98; 95% CI 0.97-0.99, p=0.001), during $45.6{\pm}16.7$ months of follow-up. 3. Among 22 patients who underwent repeat procedures, P wave axis shift was more significant in patients with maintained BDB of an anterior line than in those without (p=0.015). Conclusion: An inferior shift of P wave axis reflects the achievement and the maintenance of an anterior line BDB, and is associated with better long-term clinical outcome after catheter ablation for L-PeAF based on Dallas lesion set.

ST-T Changes of Multichannel Magnetocardiographic Pattern in Myocardial Ischemia (허혈에 의한 다채널 심자도의 ST-T 변화)

  • Kwon, H.;Kim, K.;Lee, Y.H.;Kim, J.M.;Lim, H.K.;Park, Y.K.;Chung, N.;Ko, Y.G.;Joung, B.;Kim, J.B.;Cho, J.R.
    • Progress in Superconductivity
    • /
    • v.9 no.1
    • /
    • pp.35-39
    • /
    • 2007
  • Myocardial ischemia causes heterogeneity of ventricular repolarization and sometimes produces changes of the ST-T wave in ECG. Therefore, morphological changes of ST-T waveform in ECG have a clinical significance in diagnosing myocardial ischemia. In this study, we investigated the ST-T changes caused by myocardial ischemia in magnetocardiography (MCG). We analyzed MCG patterns of biphasic T, ST segment deviations from baseline, main current angle of $T_{peak}$ and $T_{peak}$ dispersion in 300 CAD patients without ST elevation in ECG, 122 symptomatic patients and 48 normal subjects. MCGs were recorded by multichannel SQUID system in a magnetically shielded room. As results, we found that appearances of the abnormality were strongly correlated with the severity of myocardial ischemia. Also we found that the percentage of the patients showing MCG changes were higher than those in ECG. These results show that morphological changes of ST-T waveform in MCG can be used as a marker of myocardial ischemia.

  • PDF

Frequent Pattern Bayesian Classification for ECG Pattern Diagnosis (심전도 패턴 판별을 위한 빈발 패턴 베이지안 분류)

  • Noh, Gi-Yeong;Kim, Wuon-Shik;Lee, Hun-Gyu;Lee, Sang-Tae;Ryu, Keun-Ho
    • The KIPS Transactions:PartD
    • /
    • v.11D no.5
    • /
    • pp.1031-1040
    • /
    • 2004
  • Electrocardiogram being the recording of the heart's electrical activity provides valuable clinical information about heart's status. Many re-searches have been pursued for heart disease diagnosis using ECG so far. However, electrocardio-graph uses foreign diagnosis algorithm due to inaccuracy of diagnosis results for a heart disease. This paper suggests ECG data collection, data preprocessing and heart disease pattern classification using data mining. This classification technique is the FB(Frequent pattern Bayesian) classifier and is a combination of two data mining problems, naive bayesian and frequent pattern mining. FB uses Product Approximation construction that uses the discovered frequent patterns. Therefore, this method overcomes weakness of naive bayesian which makes the assumption of class conditional independence.

A Lightweight HL7 Message Strategy for Real-Time ECG Monitoring (실시간 심전도 모니터링을 위한 HL7 메시지 간소화 전략)

  • Lee, Kuyeon;Kang, Kyungtae;Lee, Jaemyoun;Park, Juyoung
    • KIISE Transactions on Computing Practices
    • /
    • v.21 no.3
    • /
    • pp.183-191
    • /
    • 2015
  • Recent developments in IT have made real-time ECG monitoring possible, and this represents a promising application for the emerging HL7 standard for the exchange of clinical information. However, applying the HL7 standard directly to real-time ECG monitoring causes problems, because the partial duplication of data within an HL7 message increases the amount of data to be transmitted, and the time taken to process it. We reduce these overheads by Feature Scaling, by standardizing the range of independent variables or features of data, while nevertheless generating HL7-compliant messages. We also use a De-Duplication algorithm to eliminate the partial repetition of the OBX field in an HL7 ORU message. Our strategy shortens the time required to create messages by 51%, and reduces the size of messages by 1/8, compared to naive HL7 coding.

Design of a Digital Modem for ECG Data Transmission (심전도 데이터 전송용 디지탈 모뎀의 설계에 관한 연구)

  • 이명호;황시돌
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.53-58
    • /
    • 1986
  • This paper represent the design of a digital modem which transmits the ECG data from an ambulatory arrhythmia monitor over the telephone lines to a large hospital for the instantaneous interpretations. The digital modem provides on-line communications between the patient and the central computer located near cardiologists. For commercial telephone lines, the transmitting error rates of the digital modem were measured 200 times at a speed of 300 baud. In those measurements, the block errors-results, due to the misinterpretation of start and stop bits, did not occur, The data bit errors which were due to a single bit interpreted incorrectly were 0.78 (bits/10 ) . Since the acceptable data bit error limit is 10 per 106 bits transmitted, the digital modem designed in this paper can be used for the clinical applications without any difficulty.

  • PDF

Remote Vital Signal Monitoring System Based on Wireless Sensor Network Using Ad-Hoc Routing

  • Walia Gaurav;Lee Young-Dong;Chung Wan-Young
    • Journal of information and communication convergence engineering
    • /
    • v.4 no.2
    • /
    • pp.67-70
    • /
    • 2006
  • A distributed healthcare monitoring system prototype for clinical and trauma patients was developed, using wireless sensor network node. The proposed system aimed to measure various vital physiological health parameters like ECG and body temperature of patients and elderly persons, and transfer his/her health status wirelessly in Ad-hoc network to remote base station which was connected to doctor's PDA/PC or to a hospital's main Server using wireless sensor node. The system also aims to save the cost of healthcare facility for patients and the operating power of the system because sensor network is deployed widely and the distance from sensor to base station was shorter than in general centralized system. The wireless data communication will follow IEEE 802.15.4 frequency communication with ad-hoc routing thus enabling every motes attached to patients, to form a wireless data network to send data to base-station, providing mobility and convenience to the users in home environment.

Changes of ECG and Electrolyte in Dogs with Experimental Obstruction of Duodenum (개에 있어서 실험적 십이지장 폐색시 심전도와 전해질의 변화)

  • 최인혁;조영숙
    • Journal of Veterinary Clinics
    • /
    • v.15 no.2
    • /
    • pp.432-441
    • /
    • 1998
  • The electrocardiogram (ECG) and electrolytes were measured to obtain diagnostic data after experimental obstruction of duodenum in 8 dogs. Clinical signs of these appeared lower heart rate, temperatures respiration and blood pressure than signs of preoperation. In changes of electrolytes and acid-base balances, all dogs appeared hyponatremiai hypochloremia, metabolic alkalosis, and increased pHi HCO3, scot in blood, but potassium values appeared to increase in 3 cases fl-inc.) and to decrease in 5 cases (K- dec.) Two of three in K-inc. and three of five in K-dec. died at 60 hrs and 72 hrs after obstruction respectly. In changes of ECGI amplitudes of the K-inc cases appeared high in T wave and low in R wave, but amplitudes of the K-dec cases appeared low T waver 57 segment and high in R wave. Conduction times of the K-inc appeared the shorted PR intervals but the K-dec appeared the prolonged PR interval. The changes of these appeared apparently in lead II.

  • PDF