Associations between Sleep Quality, Daytime Sleepiness, with Perceived Errors during Nursing Work among Hospital Nurses (간호사의 수면의 질, 주간졸음 및 간호업무 중 인지한 오류 경험과의 관련성)

  • Kim, Mi Sung;Kim, Jang-Rak;Park, Ki-Soo;Kang, Young Sil;Choe, Sung Pil Michael
    • Journal of agricultural medicine and community health
    • /
    • v.38 no.4
    • /
    • pp.229-242
    • /
    • 2013
  • Objectives: The objective of this study was to identify the influence of shift work on sleep quality, daytime sleepiness, and perceived errors during nursing work among hospital nurses. Methods: The study subjects were 209 hospital nurses working in two general hospitals in South Korea. The data were collected through self-administered questionnaires in May 2013. Sleep quality was measured using Korea Pittsburgh Sleep Quality Index (PSQI-K), daytime sleepiness was measured using Epworth Sleepiness Scale (ESS), and perceived errors in past 6 months during nursing duty hours with the tool developed in this study. Results: The sleep quality was significantly worse among rotating shift nurses when compared to fixed day duty nurses. However, the odds ratio (OR) of 1.92 [95% confidence interval(CI): 0.58-6.37] adjusted for sociodemographic variables, health behaviors, and working environment in logistic regression was not significant. There was no significant difference in the daytime sleepiness between rotating shift nurses and fixed day duty nurses in both simple and multivariable analyses. There were significantly more perceived errors in rotating shift nurses than fixed day duty nurses. However, the OR of 1.26 (95% CI: 0.38-4.21) adjusted for sociodemographic variables, health behaviors, working environment, sleep quality, and daytime sleepiness in logistic regression was not significant. Depression (OR=3.31, 95% CI: 1.11-9.84) and daytime sleepiness(OR=1.18, 95% CI: 1.07-1.30) were significantly associated with perceived errors in logistic regression. Conclusion: This study suggested shift work among hospital nurses had no independent influence of sleep quality, daytime sleepiness, and perceived errors. However, daytime sleepiness had independent influence of perceived errors. More studies are warranted to achieve more reliable conclusion.

PRELIMINARY STUDY OF MENTAL REPRESENTATIONS OF PRESCHOOL CHILDREN EXPERIENCING SINGLE, SEVERE TRAUMA (심한 정신적 외상 경험을 한 학령 전기 아동의 정신적 표상에 대한 예비연구)

  • Eon, So-Yong;Song, Won-Woung;Oh, Kyung-Ja;Choi, Eui-Gyum;Shim, Eun-Ji;Shin, Yee-Jin
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.15 no.1
    • /
    • pp.61-74
    • /
    • 2004
  • Objectives:This study was performed to introduce a psychoeducational family therapy model for the families of schizophrenic patient and to investigate the effect of this model on the changes in coping style and depressive symptoms of the family members, and in perception of emotional support by families and depressive symptoms of patients. Methods:Nine preschool children, 3-5 years old, experiencing physical injuries caused by attack from a psychotic patient at kindergarten, were evaluated for psychological assessments;Intelligence test, MSSB(MacArthur Story-Stem Battery), H-T-P test(House-Tree-Person test). And their parents completed rating scale, KPI-C(Korean Personality Inventory for Children about children’s psychological conditions). Results:With respects to the contents and emotional reactions of MSSB, 9 preschool children showed generally high levels of anxiety, depression, avoidance, aggression, probably related to the traumatic experiences. Even though children couldn't verbally report directly about their traumatic experiences, in both MSSB, structured play narrative assessment tool, and HPT, free drawing and association test, they demonstrated psychiatric problems through reenactment plays, regardless of clinical diagnoses. Conclusion:Present study allowed us the chance to see beyond the outer pathological behaviors of PTSD in preschool children, through deeper evaluations of their mental representation. These preliminary data suggest deep understanding of internal representation would be of help for thorough evaluations and treatment plan for preschool children, experiencing severe trauma.

  • PDF

Relationship between Depressive Symptoms and Sleep Parameters in Patients with Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증 환자의 우울증상 정도에 따른 수면 양상)

  • Won, Chang-Yeon;Lee, Seung-Hee;So, Min-Ah;Lee, Jin-Sung;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.14 no.2
    • /
    • pp.92-98
    • /
    • 2007
  • Objectives: Obstructive sleep apnea syndrome (OSAS) is the most common form of sleep-disordered breathing and often presents with comorbid depressive symptoms. In this study, we evaluated the relationship between depressive symptoms and sleep parameters as measured by nocturnal polysomnography (NPSG) and simultaneous wrist actigraphy. Methods: Two hundred sixty-four subjects with clinically suspected cases of OSAS underwent one-night polysomnography, while simultaneously wearing a wrist actigraphy device. They also completed two questionnaires;the Epworth Sleepiness Scale-Korean version (ESS-K) and the Beck Depression Inventory (BDI). Of the cases studied, 105 subjects were proven by NSPG to have OSAS without other sleep disorders. NPSG and wrist actigraphy data from the subjects were analyzed. Pearson correlation and paired t-test were used in order to evaluate the relationship between depressive symptoms and sleep-parameters. Results: Mean age of the subjects was $46.1{\pm}13.1$ years. Means of the ESS-K score and BDI scores were $10.9{\pm}4.7$ and $12.8{\pm}8.1$, respectively. NPSG sleep parameters significantly differed from those of wrist actigraphy. There was no correlation found between subjects' respiratory disturbance index (RDI) and BDI scores. When directly comparing sleep parameters between subjects who were more depressed versus subjects who were less depressed, both total sleep time and sleep efficiency were decreased in the more depressed. A correlation between RDI and ESS-K scores was also found in the more depressed group. Conclusions: Although our findings suggest that there is no relationship between RDI and depressive symptoms, there are other significant differences in the sleep parameters between subjects who are more depressed versus those without depression. We recommend that patients with depression should also be evaluated for clinical symptoms of OSAS.

  • PDF

The Accuracy of the Digital Imaging System and the Frequency Dependent Type Apex Locator in Root Canal Length Measurement (근관장 측정에 있어서 디지털 영상 처리기와 주파수 의존형 측정기의 정확도)

  • Lee Byaung-Rib;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.435-459
    • /
    • 1998
  • In order to achieve a successful endodontic treatment, root canals must be obturated three-dimensionally without causing any damage to apical tissues. Accurate length determination of the root canal is critical in this case. For this reason, I've used the conventional periapical radiography, Digora/sup (R)/(digital imaging system) and Root ZX/sup (R)/(the frequency dependent type apex locator) to measure the length of the canal and compare it with the true length obtained by cutting the tooth in half and measuring the length between the occlusal surface and the apical foramen. From the information obtained by these measurements, I was able to evaluate the accuracy and clinical usefulness of each systems. whether the thickness of files used in endodontic therapy has any effect on the measuring systems was also evaluated in an effort to simplify the treatment planning phase of endodontic treatment. 29 canals of 29 sound premolars were measured with #15, #20, #25 files by 3 different dentists each using the periapical radiography. Digora/sup (R)/ and Root ZX/sup (R)/. The measurements were then compared with the true length. The results were as follows: 1. In comparing mean discrepancies between measurements obtained by using periapical radiography(mean error: -0.449±0.444 mm), Digora/sup (R)/(mean error: -0.417±0.415 mm) and Root ZX/sup (R)/(mean error: 0.123±0.458 mm) with true length. periapical radiography and Digora/sup (R)/ system had statistically significant differences(p<0.05) in most cases while Root ZX/sup (R)/ showed none(p>0.05). 2. By subtracting values obtained by using periapical radiography, Digora/sup (R)/ and Root ZX/sup (R)/ from the true length and making a distribution table of their absolute values. the following analysis was possible. In the case of periapical film. 140 out of 261<53.6%) were clinically acceptable satisfying the margin of error of less than 0.5 mm. 151 out of 261 (53,6%) were acceptable in the Digora/sup (R)/ system while Root ZX/sup (R)/ had 197 out of 261(75.5%) within the limits of 0.5mm margin of error. 3. In determining whether the thickness of files has any effect on measuring methoths, no statistically significant differences were found(p>0.05). 4. In comparing data obtained from these methods in order to evaluate the difference among measuring methods, there was no statistically significant difference between periapical radiography and Digora/sup (R)/ system(p>0.05), but there was statistically significant difference between Root ZX/sup (R)/ and periapical radiography(p<0.05). Also there was statistically significant difference between Root ZX/sup (R)/ and Digora/sup (R)/ system(p<0.05). In conclusion, Root ZX/sup (R)/ was more accurate when compared with the Digora/sup (R)/ system and periapical radiography and seems to be more effective clinically in determining root canal length. But Root ZX/sup (R)/ has its limits in determining root morphology and number of roots and its accuracy becomes questionable when apical foramen is open due to unknown reasons. Therefore the combined use of Root ZX/sup (R)/ and the periapical radiography are mandatory. Digora/sup (R)/ system seems to be more effective when periapical radiographs are needed in a short period of time because of its short processing time and less exposure.

  • PDF

Clinical Application of in Vivo Dosimetry System in Radiotherapy of Pelvis (골반부 방사선 치료 환자에서 in vivo 선량측정시스템의 임상적용)

  • Kim, Bo-Kyung;Chie, Eui-Kyu;Huh, Soon-Nyung;Lee, Hyoung-Koo;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.37-49
    • /
    • 2002
  • The accuracy of radiation dose delivery to target volume is one of the most important factors for good local control and less treatment complication. In vivo dosimetry is an essential QA procedure to confirm the radiation dose delivered to the patients. Transmission dose measurement is a useful method of in vivo dosimetry and it's advantages are non-invasiveness, simplicity and no additional efforts needed for dosimetry. In our department, in vivo dosimetry system using measurement of transmission dose was manufactured and algorithms for estimation of transmission dose were developed and tested with phantom in various conditions successfully. This system was applied in clinic to test stability, reproducibility and applicability to daily treatment and the accuracy of the algorithm. Transmission dose measurement was performed over three weeks. To test the reproducibility of this system, X-tay output was measured before daily treatment and then every hour during treatment time in reference condition(field size; $10 cm{\times} 10 cm$, 100 MU). Data of 11 patients whose pelvis were treated more than three times were analyzed. The reproducibility of the dosimetry system was acceptable with variations of measurement during each day and over 3 week period within ${\pm}2.0%$. On anterior- posterior and posterior fields, mean errors were between -5.20% and +2.20% without bone correction and between -0.62% and +3.32% with bone correction. On right and left lateral fields, mean errors were between -10.80% and +3.46% without bone correction and between -0.55% and +3.50% with bone correction. As the results, we could confirm the reproducibility and stability of our dosimetry system and its applicability in daily radiation treatment. We could also find that inhomogeneity correction for bone is essential and the estimated transmission doses are relatively accurate.

Prognostic Factors for Survival in Patients with Stage IV non-small Cell Lung Cancer (제 IV병기 비소세포폐암의 예후인자)

  • Kim, Myung-Hoon;Park, Hee-Sun;Kang, Hyun-Mo;Jang, Pil-Soon;Lee, Yun-Sun;An, Jin-Yong;Kwon, Sun-Jung;Jung, Sung-Soo;Kim, Ju-Ock;Kim, Sun-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.4
    • /
    • pp.379-388
    • /
    • 2002
  • Background : Although patients with stage IV non-small cell lung cancer are known to have a poor prognosis, the prognostic factors for survival have not been well evaluated. Such factors may be different from those for overall survival. This study was performed to analyze the prognostic factors for survuval and the variation of survival according to metastatic organ, in patients with stage IV non-small cell lung cancer. Materials and Methods : From January 1997 to December 2000, 151 patients with confirmed stage IV non-small cell lung cancer were enrolled into this study retrospectively. The clinical and laboratory data were analyzed using univareate Kaplan-Meied and Multivariate Cox regression models. Results : On univariate analysis, age, performance status, serum albumin level, weight loss, forced expiratory volume in one second (FEV1), systemic chemotherapy, the number of metastatic organs and serum lactate dehydrogenase (LDH) level were significant factors (p<0.05). In multivariate analysis, important factors for survival were ECOG performance (relative risk of death [RR]: 2.709), systemic chemotherapy (RR: 1.944), serum LDH level (RR: 1.819) and FEV1 (RR: 1.774) (p<0.05), Metastasis to the brain and liver was also a significant factor on univariate analysis). The presence of single lung metastasis was associated with better survival than that of other metastatic organs (p=0.000). Conclusion : We confirmed that performance status and systemic chemotherapy were independent prognostic factors, as has been recognized. The survival of stage IV non-small cell lung cancer patients was different according to the metastatic organs. Among the metastatic sites, only patients with metastasis to the lung showed bettrer survival than that of other sites, while metastasis of the brain or liver was associated with worse survival than that of other sites.

Etiologies and Prognostic Factors of Chronic Cor Pulmonale (만성 폐성심의 원인 질환 빛 예후 인자에 관한 연구)

  • Park, Yoong-In;Kim, Sang-Hyun;Ha, Jae-Kyung;Kim, Seong-Ho;An, Byoung-Jae;Bae, Woo-Hyung;Lee, Hyeon-Gook;Chun, Kook-Jin;Hong, Taek-Jong;Park, Soon-Kew;Shin, Yung-Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.5
    • /
    • pp.609-617
    • /
    • 1999
  • Background: The aims of this study were to assess the etiologies, survival and prognostic factors of patients with chronic cor pulmonale visited Pusan National University Hospital. Methods : This study included 103 patients with chronic cor pulmonale. There were 67 men and 36 women. The diagnosis of chronic cor pulmonale was primarily based on the presence of underlying lung disorder and echocardiographic finding of enlarged or hypertrophied right ventricle. Other clinical data including patients' symptoms and signs, findings of arterial blood gas analysis, hematologic and biochemical laboratory and pulmonary function test were assessed. Results: The most common underlying lung disorder was pulmonary tuberculosis(59.2%) and chronic obstructive pulmonary disease was the next(28.2%). The survival rate was 57% in one year, 45% in two years, and 34% in three years. The prognostic factors were maximal voluntary ventilation(MVV), forced vital capaoity(FVC), $FEV_1$ serum Na, vital capacity(VC), serum albumin and peak expiratory flow(PEF) in univariate analysis. And in multivariate analysis, serum albumin(p=0.0144) and VC(p=0.0078) were statistically significant. Conclusion: Pulmonary tuberculosis was the most important underlying lung disorder in chronic cor pulmonale. The survival rate was 57% in one year, 45% in two years, and 34% in three years. Serum albumin (p=0.0144) and VC(p=0.0078) were statistically significant prognostic factors.

  • PDF

Clinical Significance of Serum PDGF-BB and IGF-1 in Coal Workers' Pneumoconiosis (석탄광부 진폐증 환자에서 PDGF-BB, IGF-1의 의의)

  • Shin, Pyo Jin;Yong, Suk Joong;Shin, Kye Chul;Lee, Won Yeon;Kim, Shin Tae;Cha, Bong Suk;Jeon, Geun Jae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.4
    • /
    • pp.338-345
    • /
    • 2002
  • Background : Coal workers' pneumoconiosis(CWP) is a fibrotic lung disease resulting from the chronic inhalation of coal dust. Various cytokines and growth factors secreted from macrophages and monocytes play a key role in the pathogenesis of pneumoconiosis. The platelet-derived growth factor (PDGF)-BB and the insulin-like growth factor(IGF)-1 secreated from the macrophages and monocytes are believed to stimulate the accumulation of mesenchymal cells and fibrosis of the lower respiratory tract that is observed in fibrotic lung disease. The serum concentraion of PDGF-BB and IGF-1 in 30 CWP patients and 10 healthy controls were measured in order to determine if PDGF-BB and IGF-1 can be used as sensitive biomarkers in CWP. Method : Serum was collected from 30 patients with CWP(13 with simple CWP and 17 with complicated CWP) and 10 healthy controls. The serum concentrations of PDGF-BB and IGF-1 were measured using ELISA (R&D system, Minneapolis, MN). Results : The serum PDGF-BB concentration in patients with complicated CWP($10083.76{\pm}639.07pg/mL$) was significantly higher than in the patients with simple CWP ($8493.88{\pm}848.51pg/mL$) and the healthy controls ($3726.17{\pm}292.20pg/mL$) (p<0.05). Compared to the healthy controls ($413.40{\pm}1.94ng/mL$), there was no significant difference in the serum IGF-1 concentration in patients with simple ($366.77{\pm}183.67ng/mL$) and complicated CWP ($403.18{\pm}15.39ng/mL$) (p>0.05). Conclusion : These results show the important role of the PDGF-BB mediated pathways in the pathogenesis of CWP. These data suggests that the PDGF-BB serum concentration is a useful biomarkers of the fibrotic extent in CWP patients.

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

Normative data of penile length in Korean newborns (한국인 신생아 음경 길이에 대한 연구)

  • Kim, Sang Yeob;Jun, Jae Sung;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.9
    • /
    • pp.944-949
    • /
    • 2008
  • Purpose : As modern society has became more open, interest in healthy internal and external growth has increased, including that pertaining to penile length in children. A micropenis is defined as one where penile length is more than 2 SD (standard deviation) below the mean, and it can be traced back to chromosome and endocrine disorders. The authors executed this study to suggest guidelines for the study of the micropenis and standard information for penile length in Korean newborns. Methods : The subjects of this study were 168 male infants between 37 and 42 weeks of gestational age, none of whom had any complications during pregnancy or birth; each had been born in Daegu Fatima Hospital between February and June 2007. Penile length was measured using conventional stretched penile length measurement (CPLM) and syringe methods. Results : Penile length was $3.02{\pm}0.25cm$ (F=36.467, $R^2=0.180$, P<0.001) when measured with CPLM, and $3.29{\pm}0.26cm$ (F=9.149, $R^2=0.052$, P<0.001) with the syringe method. There was no statistically significant difference in the penile length of newborn infants as a result of taking measurements with the two methods, and both methods showed significance at 0.631 in terms of Pearson's correlation coefficient, at the level of P=0.01. Conclusion : In this study, penile length tended to be longer when gestational age was longer, and a micropenis can be assumed to be one less than 2.5 cm using CPLM and less than 2.8 cm using the syringe method. In the case of a concealed penis, the syringe method is helpful. When a micropenis is assumed, close observation by outpatient department personnel, and additional endocrine and chromosome studies should be undertaken after sufficiently consulting the parents.