• Title/Summary/Keyword: Climatic environment chamber

Search Result 22, Processing Time 0.028 seconds

Performance Evaluation of Paving Blocks Based Ambient Temperature Reduction Using a Climatic Environment Chamber (기후환경챔버를 활용한 블록의 공기온도 저감 성능평가)

  • Ko, Jong Hwan;Park, Dae Geun;Kim, Yong Gil;Kim, Sang Rae
    • Ecology and Resilient Infrastructure
    • /
    • v.4 no.4
    • /
    • pp.187-192
    • /
    • 2017
  • This study evaluated the reduction performance of ambient temperature and the amount of evaporation that takes place depends on the temperature difference of paving blocks which are used in the sidewalk, roadway, parking lot, park, plaza, and etc. The water-retentive block of the LID (Low Impact Development) practice was compared with the conventional concrete block. For the quantitative performance evaluation, experiments were performed in a climatic environment chamber capable of controlling the climatic environment (solar radiation, temperature, humidity, rainfall, and snowfall). The method for performance evaluation was proposed using temperature, humidity, and ambient air of paving blocks which changes according to the solar radiation and the wind speed after the rainfall. As a result, the evaporation amount of the water-retentive block was 2.6 times higher than that of the concrete block, the surface temperature of water-retentive block was $10^{\circ}C$ lower than the concrete block, and the air temperature of water-retentive block was $4.6^{\circ}C$ lower than the concrete block. Therefore, it is analyzed that the water-retentive block with a large amount of evaporation is more effective in reducing the urban heat island phenomenon as compared with the concrete block.

Study on Improvement of Working Environment in Plastic House to Prevent Plastic House Syndrome (하우스증 예방을 위한 비닐하우스내 작업환경 개선에 관한 연구)

  • 김명주;최정화
    • Korean Journal of Rural Living Science
    • /
    • v.5 no.2
    • /
    • pp.107-115
    • /
    • 1994
  • This study was conducted to provide a counterplan for preventing so celled “plastic house syndrome” revealed among farmers spending much time in the plastic houses. For this, working environment inside a plastic house was observed. Then, experiments were carried out mostly in a climatic chamber with three kinds of working posture on uneven($D_1-F_1$) or even($D_2-F_2$) ground surface. Tested work loads with three kinds of working posture were : moving in a sitting posture with attaching breast to legs and waving arms ($A_1$), moving in a bending posture with waving arms ($B_1$), and moving a 6kg weighting luggage in a standing posture ($C_1$) Physiological responses in the workers to three different work loads were observed in a climatic chamber, with or without using some instruments, to evaluate work efficiencies. The results obtained are summerized as follows. 1. $C_1$ was the hardest work and $B_1$ was harder than $A_1$ on the even ground. 2. Worker's physiological fatigue and physical loads remarkably decreased when using the instruments such as a chair and a cart with some rollers on the even ground. 3. Working with pushing a cart($F_1$) was the hardest work, and standing($D_1$) was harder than walking($E_1$) on the uneven ground. 4. Worker's physiological fatigues and physical loads remarkably decreased on the even ground. 5. Similar results were obtained when the same experiment was carried out in a plastic house.

  • PDF

Study on the International Climatic Testing Standard for Passenger Car (철도차량의 국제 기후환경 시험규격의 수행방안 연구)

  • Yoon, Young-Kwan;Cho, Young-Min;Choi, Jin-Sik;Jung, Woo-Sung;Kwon, Soon-Bark;Park, Duck-Shin
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1327-1334
    • /
    • 2011
  • subway has became citizen's feet which can transport over 24 million people since the era of high oil price started. Because the request of passengers for more comfortable thermal comfort is drastically increasing, the importance of comfortable environment in the passenger car is more stressed. This paper suggests an indicator whether railroad car is fitted with suitable cooling and heating equipment by applying the international climatic testing method, UIC 553, 553-1. Specified ambient temperature, humidity, solar irradiation condition, as well as extreme outside condition, can be achieved by using an environmental chamber. The change temperature and humidity in the passenger space can be monitored to judge if the passenger room is nicely air-conditioned.

  • PDF

Efficacy of Cooling Vests for Alleviating Heat Strain of Farm Workers in Summer (여름철 농민의 서열 부담 경감을 위한 냉각조끼의 성능 평가)

  • Choi Jeong-Wha;Kim Myung-Ju;Lee Joo-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.8 s.145
    • /
    • pp.1176-1187
    • /
    • 2005
  • The purpose of this study was to evaluate the efficiency of cooling vests developed for farm workers harvesting red pepper in summer. The study was performed using the following two steps: 1) Climatic chamber test, 2) Field test. For the chamber test, a work environment was simulated as $33^{\circ}C$ and $65\%$RH, and the thermo-physiological and subjective responses were measured with and without cooling vests. Twelve young males participated as subjects. For the field test, three farmers participated while harvesting red pepper on the form, in summer. The measurements used were same as in the chamber test. Subjects were tested without any cooling vests, as a control. They were tested wearing vests with 2 frozen gel packs (CV2: Cooling area, $308cm^2$), and vests with 4 frozen gel packs (CV4: Sooting area, $616cm^2$). As a result of the chamber test, rectal temperature($T_{re}$) and mean skin temperature( $T_{sk}$) were lower in both CVs than in Control, and this tendency was statistically significant in CV4 (p<.05). Clothing microclimate temperature ($T_{clo}$) and total sweat rate (TSR) were significantly lower when wearing cooling vests (p<.05) Heart rate (HR) was also lower in wearing cooling vests than in Control, and the speed of recovery to the comfort level was faster when the subjects wore cooling vests. In addition, subjects felt 'less hot, less humid, and less uncomfortable' in both CVs than in Control. Field tests showed a similar tendency with the chamber tests. In particular, wearing the cooling vest was effective in restraining the raise of $T_{clo}$ on the back. It can be concluded that the cooling vest was effective in alleviating heat strain and discomfort in both the chamber test and the field test, despite the cooling area of the cooling vest being just $3.4\%$ of the body surface area ($616cm^2$).

Performance evaluation of Surface Temperature Reduction by using Green infrastructure Surface Temperature Measurement for Urban Heat Island Mitigation (도시열섬완화를 위한 그린인프라시설의 표면온도 저감 성능평가)

  • Ko, Jong Hwan;Bae, Woo Bin;Park, Dae Geun;Jung, Won Kyong;Park, Yun mi;Kim, Yong Gil;Kim, Sang Rae
    • Ecology and Resilient Infrastructure
    • /
    • v.5 no.4
    • /
    • pp.257-263
    • /
    • 2018
  • This study is to develop a GSTM (Green infrastructure Surface Temperature Measurment) equipment for reducing the surface temperature of GI by using LID Method. The tests were conducted including GI products such as Greening block, Pervious Block, Soil Block and so on. The GSTM equipment developed by considering the literature surveys are characterized as follows. The non-contact infrared temperature sensor was used to measure the surface temperature, and it was improved to measure the overall average temperature including the center and the corner temperature of the specimen. The developed GSTM equipment was used to compare performance of asphalt and GI products. As a result, the Greening Block show a high difference of $18.4^{\circ}C$ and it contributes to the decrease of surface temperature.

Diagnosis of Office Occupant's Adaptation Level for Thermal Environment (사무실 근무자의 온열환경에 대한 적응수준 진단)

  • Kim, Yang-Weon
    • Korean Journal of Human Ecology
    • /
    • v.12 no.5
    • /
    • pp.747-754
    • /
    • 2003
  • The actual clothing conditions were surveyed to diagnose clothing condition of Korean female in the view point of the adaptation to the thermal environment according to seasonal changes. Then, clothing microclimate, physiological responses, and subjective sensation were investigated through wearing trials on human body in climatic chamber based on the results from the survey. Factors to evaluate validity of clothing condition were clothing weight, clothing microclimate, physiological response of human body, and subjective sensation. The results were as follows: 1. Clothing weight per body surface area of the season was $856g/m^{2}$, $439g/m^{2}$ in summer, $630g/m^{2}$ in fall, and $1184g/m^{2}$ in winter. Cold - resistance of Korean female in office was superior to Japanese, inferior to residents of rural areas of Korea, and similar to male in office. However, in heat - resistance, female in office was inferior to residents of rural areas of Korea. 2. In spring, fall, winter, clothing microclimate temperature was a little higher than that in summer. Therefore, it was not a desirable wearing condition even though the clothing microclimate was comfortable zone. 3. Mean skin temperature of female in office was including within the range of Winslow's comfortable zone, but the range of comfortable zone in mean skin temperature of female was more narrow than Winslow's. Thus, it has problem for female to adaptation to thermal environment.

  • PDF

Study of the Effects of Ambient Temperature and Car Heater Power on the Train Cabin Temperature (외기 온도와 난방 출력의 철도차량 객실 온도에 대한 영향 연구)

  • Cho, Youngmin;Park, Duck-Shin;Kwon, Soon-Bark;Jung, Woo-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5877-5884
    • /
    • 2014
  • Recently, abnormally cold weather has been reported more frequently in winter due to the climate change and abnormal weather changes. On the other hand, the heating capacity of a railcar may be not enough to warm the cabin under severe cold climatic conditions, which is one of the reasons for the passengers' complaints about heating. In this study, the effects of ambient temperature and heater power on the cabin temperature was investigated to obtain the minimum ambient temperature for the tested railcar. The test railcar was placed in a large-climatic chamber, and various ambient temperature conditions were simulated. The effects of the heater output were investigated by monitoring the cabin temperature under a range of heater output conditions. The mean cabin temperature was $14.0^{\circ}C$, which was far lower than the required minimum temperature of $18^{\circ}C$, under a $-10^{\circ}C$ ambient temperature condition with the maximum heat power. When the ambient temperature was set to $0^{\circ}C$ and $10^{\circ}C$, the maximum achievable cabin temperature was $26.1^{\circ}C$ and $34.0^{\circ}C$. Through calculations using the interpolation method, the minimum ambient temperature to maintain an $18^{\circ}C$ cabin temperature was $-6.7^{\circ}C$ for this car. The vertical temperature difference was higher with a higher power output and higher ambient temperature. The maximum vertical temperature difference was higher than $10^{\circ}C$ in some cases. However, the horizontal temperature difference vs. low temperature (< $2^{\circ}C$) was independent of the power output and ambient temperature. As a result, it is very important to reduce the vertical temperature difference to achieve good heating performance.

Study on Atmospheric Corrosion for Two Different Marine Environments in India

  • Saha, Jayanta Kumar
    • Corrosion Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.120-127
    • /
    • 2007
  • In any developing nation major investment goes for infrastructure and it is not exception in India. Good numbers of buildings, bridges, shopping malls, car parks etc. are coming up with steel for sustainable development. Thus protecting the structures from corrosion are the challenges faced by professionals for all types of steel structures. About 3% of GDP is accounted for loss due to corrosion. To combat this up to date corrosion map is called for as the country has wide variation of climatic zones with vastcoastline. Logically organic paint system can be prescribed based on the corrosion rate on bare steel with respect to environment. Present paper will emphasis on the study conducted on two types of structural steel coated with organic paint located in twomarine environment having been exposed for three years, Test coupons made from steels both bare and coated are deployed at two field stations having marine (Digha) and industrial marine (Channai) environments. Various tests like AC impedance DC corrosion, polarisation, salt spray test, $SO_2$ chamber and Raman spectroscopy were carried out both in laboratory on fresh as well as coupons collected from exposure sites. Rust formed on the bare and scribed coated coupons are investigated. It is found that normal marine environment at Digha exhibits higher corrosion rate than polluted marine environment in Channai. Rust analysis indicates formation of ${\propto}$-FeoOH protects or reduces corrosion rate at Channai and formation of non-protective ${\gamma}$-FeoOH increases corrosion rate at Digha. The slower corrosion rate in Channai than at Digha is attributed due to availability of $SO_2$, in the environment, which converts non‐protective rust ${\gamma}$-FeoOH to protective rust ${\propto}$-FeoOH. While comparing the damage on the coated panels it is found that low alloy structural steel provides less damage than plain carbon steel. From the experimentations a suitable paint system specification is drawn for identical environments for low medium and high durability.

Physiological Responses and Subjective Sensations by Clo Values at -10℃ (환경온도 -10℃에서 Clo값에 따른 인체 생리반응 및 주관적 감각)

  • Kim, Ji-Yeun;Song, Min-Kyu;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.12 no.4
    • /
    • pp.531-537
    • /
    • 2010
  • The purpose of this study was to review physiological responses and subjective sensations in the cold environment when the subjects wore ensemble with different clo values. Seven healthy male subjects participated in this experiment. This experiment was conducted in a climatic chamber with $-10^sC$ and 50%RH. Subjects wore five different kinds of ensemble[C1 (4.453 clo), C2 (3.452 clo), C3 (2.865 clo), C4 (2.387 clo), and C5 (2.280 clo)]. The experiment was composed of 20 min of rest period, 20min of treadmill exercise(6 km/h) period, 30 min of recovery period. We monitored skin temperature on 7 sites, clothing microclimate and subjective sensations. The clo value had positive correlations with mean skin temperature and clothing microclimate. The subjects feel more warm and humid as the clo value goes up. The subjects reported comfort when they wore C1 and C2 ensemble having over 3 clo value. However, they felt less comfortable during the exercise period since there was high humidity. Skin temperature on the extremities were more dramatically changed by the exercise rather than clo value. Thus it seems that in the cold environment, heat balance can mostly be controlled by the choice of clothing, and the clothes with high clo values can provide higher insulation. In conclusion, our findings suggest that it would be more effective to control clo value depending on the activity level for maintaining comfort level in the cold environment.

Study on Optimal Design and Performance Test of Chilled Beam Unit (칠드빔 유니트의 최적설계 및 성능평가 연구)

  • Kim, Jung-Yup;Shin, Hyun-Jun;Joo, Sang-Hyun;Kim, Ji-Seok
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.5
    • /
    • pp.11-18
    • /
    • 2014
  • Chilled Beam system is the kind of water-air system which reduces the conveyance energy for air conditioning as well as allows efficient installation and comfortable indoor environment, and has been increasingly popular mainly in Europe. To effectively install such Chilled Beam system domestically, it is necessary to develop the product considering domestic climatic condition and the requirements for air conditioning system, and particularly the way to deal with condensation during operation of cooling system in summer shall be provided. In this study, the optimal design on induction structure of Chilled Beam unit was carried out through a numerical method, and the performance test for the prototype of unit was conducted in a real-scale experiment facilities of Chilled Beam unit. While the flowrate of 1st air is 101.3 CMH, the pressure in pressure chamber is 158.7 Pa and the cooling capacities of 1st air side and 2nd air side are 498.1 W and 709.5 W respectively.