• Title/Summary/Keyword: Climatic design

Search Result 156, Processing Time 0.021 seconds

A Study on the Thermal Performance of a Solar House by a F-chart Method (F-chart 설계법(設計法)에 의한 태양열주택(太陽熱住宅)의 난방성능(暖房性能)에 관(關)한 연구(硏究))

  • Lee, Young-Soo;Seoh, Jeong-Ill;Yim, Jang-Soon
    • Solar Energy
    • /
    • v.2 no.2
    • /
    • pp.1-9
    • /
    • 1982
  • This paper presents a method. for estimating the useful output of solar heating sys-terns. Heating load calculations, climatic data and various conditions are used in this procedure to estimate the fraction of the monthly heating load supplied by solar energy for a particular system the design procedure presented in this paper referred to the f-chart method. The results of this study are as follows; 1) The collected energy is not rised lineary to collector area. 2) If the heating area has equivalent solar collector area, the solar energy utilization for space heating is over 90%. 3) Transmittance- absorptance product for radiation at normal incidence, (${\tau}{\alpha}$)/(${\tau}{\alpha}$)n, during most of the heating season is 0.92 for a two-cover collector. 4) Orientation of the collector has little effect on the annual performance of solar heating system within the $15^{\circ}$.

  • PDF

Development of Sliding Roof System for High-rise Construction Factory Using Quality Function Deployment (품질기능전개를 이용한 고층건물 건설공장 구조체의 개폐식 지붕 시스템 개발)

  • Kim, Chang-Won;Kim, Baek-Joong;Cho, Hunhee;Kang, Kyung-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.131-132
    • /
    • 2011
  • Non-working days owing to climatic factors have been negatively affected in productivity of construction, such as delays of project completion times, decrease productivity of construction. Especially non-working days of steel erection work is about 58 days, it is influenced deleteriously to estimating uncertain construction duration. To solve this problem, Construction Factory(CF) and sliding roof system installed CF's upper side are developed in korea recently. This study is proposed the design of sliding roof system through assess relation of requirements and technical characteristics using Quality Function Deployment(QFD). The basis data for applying QFD is collected from literature reviews and questionnaires/interviews targeting system developer, experts and researchers.

  • PDF

Physiological Strains of Asbestos Abatement Work Wearing Protective Clothing in Hot-Humid Environments

  • Tochihara, Yutaka;Ohnaka, Tadakatsu
    • Fashion & Textile Research Journal
    • /
    • v.2 no.5
    • /
    • pp.411-415
    • /
    • 2000
  • To be able to work safely and efficiency, the Threshold Limit Values (TLV) for work in the heat are widely used. Since these TLV are only applicable to workers in regular clothing, TLV should be adjusted when applied to the asbestos removal workers who wear extra impermeable protective clothing. Although abbreviated guidelines for heat stress exposure have been proposed, literature advocating their use in the asbestos removal industry is limited. Therefore, we planed a survey to evaluate the workload of asbestos abatement workers in summer, and an experiment with climatic chambers to evaluate the effects of resting in a cool environment between work periods. From these studies, we got following conclusions. There is a high risk of suffering from heat illness by asbestos abatement work in summer in Japan. It is proposed to create a cool room inside the workplace of asbestos abatement work to reduce thermal stress.

  • PDF

The Distribution Characteristics of Salt Contaminants with Statistical Method in East Coast (통계적 처리방법을 이용한 동해안 염해 오손물의 분포특성)

  • Choi, Nam-Ho;Park, Kang-Sik;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.3
    • /
    • pp.130-135
    • /
    • 2001
  • In this paper, the distribution characteristics of salt contaminants with the distance from sea in East coast, from Sokcho to Pusan of Korea peninsula were investigated to evaluate the design standard of KEPCO. To get the equivalent salt deposit density(ESDD), conventional brush wiping method was used. As the measuring period is comparatively short, and the measuring interval is long to check the maximum value, acquired ESDD data is very lower than the recommended value in the standard. The measured data didn't follow normal distribution, so it should take the statistical treatment. Through normalizing method, we could get a reliable probability data. In the past investigation, the accumulation characteristics of Japan is consulted to set the criterion, but the climatic condition of Korea is different to Japan. With the comparison of precipitation data and some measured data for long tern accumulation, we could set appropriate accumulation factor.

  • PDF

Stack Effect Guidelines for Tall, Mega Tall and Super Tall Buildings

  • Simmonds, Peter;Zhu, Rui
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.4
    • /
    • pp.323-330
    • /
    • 2013
  • The ASHRAE Technical Committee for Tall Buildings, TC 9.12, has defined a tall building as one whose height is greater than 300 feet (91m). Since the publication of the HVAC Design Guide for Tall Commercial Buildings in 2004, there were only about 300 buildings taller than 200 meters; this number has risen to 600 in 2010 and the prediction 765 buildings taller than 200 meters in 2012. There has also been an introduction of two new classes of tall buildings: ${\bullet}$ Mega tall, which are buildings taller than 300 m, and ${\bullet}$ Super tall, which are buildings taller than 600 m. The effect of ambient air temperature over the height of buildings, especially Mega tall and Super tall buildings. The ambient climatic conditions vary with altitude and these changes in ambient conditions can seriously affect load calculations and performance of super and mega tall buildings. This paper presents revised calculations for stack effect for Tall, Mega Tall and Super tall Buildings.

A Study on the Optimum Slope of the Roof for Minimum Cooling Load (냉방부하 최소화를 위한 지붕의 최적기울기에 관한 연구)

  • Tae, Won-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.119-123
    • /
    • 2005
  • The main purpose of this study is to define an optimum slope of the roof that demands minimum cooling load of the building, when the roof is affected by the solar and wind energy. Two different roof shapes were chosen: hip, gabled. The cooling load of building having those roof shapes was calculated through the computer simulation, using DOE program. For the simulation, the angle of the roof and angle of the orientation was changed. In the conclusion of this paper, an optimum slope of the roof which causes minimize cooling load is presented according to the roof shape and orientation. The result of this study could provide a practical design guideline for determining the roof angle for various climatic conditions.

Study on Clean Development Mechanism Baseline Design (청정개발체제(CDM) 기준선 설계에 관한 연구)

  • Jin, Dong-Geun;Ree, Sang-Bok
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2006.04a
    • /
    • pp.129-134
    • /
    • 2006
  • Environmental pollution was begun to rise suffering increase in population with fast economic growth after industrial revolution teeth. Be, air pollution out of them, pollution most seriously happen, and began to cope in greenhouse gas danger from this time. Presents greenhouse gas problem is becoming universal interest ago, and our country is becoming problem. Wish to reduce greenhouse gas in world climatic change convention through Gyoto mekanijeum to reduce greenhouse gas. Wish to present standard for consideration in among CDM business, base line formation out of them.

  • PDF

A Study on Pattern Recognition to Compute Guidelines Based on Evidence for Ecological Healing Environment at Agha Khan Hospital in Karachi - Focused on Human Thermal Comfort Model (HTCM), for Karachi, using Climate Consultant Program

  • Shaikh, Javaria Manzoor;Park, Jae Seung
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.27-35
    • /
    • 2015
  • Purpose: Healthcare is on the whole a personal and critical service that consumer's use, whereas hospitalization is as a rule painful, because nature nurtures and Sun Light Luminosity for healthcare settings is considered healing. The performance and design of climate responsive buildings such as AKU requires a detailed study of attributes of climate both at micro as well as macro level. The therapeutic value of contact with nature through window view, greenery and landscape is calculated there. Method: A two prong strategy is been devised for this article, at micro level three typical morphologies are analysed by creating same environment of neighboring building on sun shading chart, radiation and temperature range. Since the analysis of local climate helps to determine the design strategies for hospital Healing Environment which is suitable for Karachi climate; in order to track the macro climatic behaviour, a considerable analysis of psychometrics chart for AKU Karachi are designed on Climate Consultant (CC) and analysed by Machine Learning. Climate Consultant proposes different design strategies suitable for Karachi. And on the other hand time wise illumination sources for clinical area which are then measured on psychrometric chart- according to singular space: multi patient admission, secondly: acute ambulatory ward, and tertiary: multi windowed space according to the mushrabiyah and sky light pattern. Result: Our findings support the hypothesis that windowed wall is 75-80% more healing wall; an accelerated evidence was found for healing at macro level if the form of the hospital is designed according to the climatologically preferences, whereas at micro level: the light resource becomes the staff attentiveness determinant. In Conclusion evidence was provided that the actual form of luminosity results consequently in satisfaction while light entering from several set of windows and other sources might be valued if design according to the healing environment. The data added on the sun shading chart to calculate rays entraining into space in patient room equal to 124416.21 Watts/ meter $m^2$ is calculated as precise healing rate-and is confirmed by questionnaire from patients belonging from each clinical stage having different illnesses.

The verification about possibility of introducing Window to Floor Ratio as design index for building energy performance

  • Choi, Won-Ki;Lee, Yong-Jun;Lee, Hyun-Soo;Eom, Jae-Yong;Lee, Chung-Kook
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.23-28
    • /
    • 2017
  • Purpose: Many design index that are using in planning phase have been developed. The most popular things among them are Window to Wall Ratio and Surface to Volume Ratio. However there are some limits. Window to Wall Ratio cannot consider building size and Surface to Volume Ratio cannot do Window to Wall Ratio. Accordingly, in this paper, the Window to Floor Ratio was proposed that it can be considered both building size and Window to Wall Ratio. And analyzed correlation of energy demand. Method: For the test, 16 modules with the size of $6m{\times}6m{\times}4m$ were used to make 35 models with the same volume. The simulation was conducted to 945 cases using the window-to-wall ratio of 30, 50 and 70 % in three areas such as Seoul, Gwangju and Jeju and three kinds of windows. And IES_VE was used. Result: The findings above show that the Window to Floor Ratio that can be considered both building size and Window area have to become as design index. It was found out that design criteria with SHGC is necessary, not with the thermal performance (U-value). It is needed to additional analysis about residential building and the effect of 24-hours heating and cooling condition. It plans to carry out research to establish design indicators for climatic conditions in the country and building applications.

Analysis of Design Elements and Barriers to Link the Emission Trading Systems between the Republic of Korea and China (한·중 배출권거래제 연계를 위한 설계요소 및 장애요인 분석)

  • Park, Su Gyeong;Park, Soon chul;Song, Cholho;Lim, Chul-Hee;Lee, Soo Jeong;Lee, Woo-Kyun
    • Journal of Climate Change Research
    • /
    • v.9 no.4
    • /
    • pp.471-485
    • /
    • 2018
  • The Republic of Korea (ROK) has made many efforts to reduce greenhouse gases through a legal framework, making obligations to reach domestic and overseas targets via the Paris Convention in 2015. China recently launched a nation-wide emission trading system (ETS) and has considered extending this ETS to include the ROK. This study examines the possibility of linking the ETS between ROK and China by considering the institutional design elements of the ETS. Additionally, this study provides policy implications to reach Korea's overseas reduction target. For the research methodology, the design elements of both the ROK and China policies were analyzed by categorizing their standard design elements based on the International Carbon Action Partnership. This paper focuses on four main barriers (cap type, borrowing, offset and price ceiling) based on their environmental benefits and analyzes the challenges to combining the design elements between the ROK and China systems. The two ETS commonly share the same cap types, and there is similar institutional progress regarding the offset and price ceiling. In addition to this, note that China has a borrowing system that is opposite to the borrowing system in ROK. According to these findings, there are major challenges to linking the ROK and China systems due to differences in the major design elements. Thus, it is necessary to modify the Korean domestic borrowing system and understand the Chinese institutional processes related to environmental negotiation to achieve further cooperation.