• Title/Summary/Keyword: Clearances

Search Result 199, Processing Time 0.027 seconds

A Study on Null Characteristics of 4-way Spool Valve (4방향 스풀밸브의 중립특성에 관한 연구)

  • Ham, Young-Bog;Yun, So-Nam;Lee, Geun-Ho;Kim, Sung-Dong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.8
    • /
    • pp.165-171
    • /
    • 2000
  • In this study the 4-way spool valve characteristics are clearly defined and clearly defined and proposed new type of spool valve. This paper presents governing equations of the flow through clearances between sleeve and spool as a model of orifice flow for null characteristics analysis and programmed analysis software of it. This software is possible to basically analysis that not only which case of open center closed center or critical center but _ -displacement of spool lab position boundary region and spool opening of the valve and to estimate the pressure variation in the spool and external leak flow variation. We are convinced that the scale of load pressure difference is changed as lab condition of valve and this scale is changed with boundary point on the annular clearance. It is vary useful to designer and user of spool valve with this design data and analysis software.

  • PDF

Physiological Pharmacokinetic Model of Ceftriaxone Disposition in the Rat and the Effect of Caffeine on the Model

  • Kwon, Kwang-Il;Bourne, David-W.A.
    • Archives of Pharmacal Research
    • /
    • v.13 no.3
    • /
    • pp.227-232
    • /
    • 1990
  • A Physiologically based pharmacokinetic model was used to describe the distribition and elimination of cefriazone in the rat. To validate the practical application of the model, the effect of cffeine on the model was also examined. The model consisted of eleven compartments representing the major sites for ceftriaxone distribution including carcass which served as a residual compartment. Elimination was represented by renal and hepatic (metabolic biliary )excretion with GI secretion and re-absorption. The drug concentrations in most of the tissues were simulated using flow limited equations while brain levels were simulated using membrane limited passive diffusion distribution. The experimental data were obtained by averaging the concentration of drug in the plasma and tissues of five rats after i. v. injection of cefriazone 100 mg/kg without and with caffeine 20 mg/kg. The data for the amount of ceftriazone excreted in urine and gut contents were used to apportion total body clearance. HPLC with UV detection was used for the assay with 0.1-0.2 $\mu$g/ml sensitivity. The great majority of drug concentrations with and without caffeine show reasonably good agreements to the simulation results within 20%. The effect of caffeine on renal and hepatic clearances was apparent with 18.8% and 18.6% increase in the model values, respectively.

  • PDF

Analysis of Factors Driving the Participation of Small Scale Renewable Power Providers in the Power Brokerage Market (소규모 재생발전사업자의 중개시장참여 촉진요인 분석)

  • Li, Dmitriy;Bae, Jeong Hwan
    • New & Renewable Energy
    • /
    • v.18 no.3
    • /
    • pp.32-42
    • /
    • 2022
  • Rapid spread of intermittent renewable energy has amplified the instability and uncertainty of power systems. The Korea Power Exchange (KPX) promoted efficient management by opening the power brokerage market in 2019. By combining small-scale intermittent renewable energy with a flexible facility through the power brokerage market, the KPX aims to develop a virtual power plant system that will allow the conversion of existing intermittent renewable energy into collective power plants. However, the participation rate of renewable power owners in the power brokerage market is relatively low because other markets such as the small solar power contract market or the Korea Electric Power Corporation power purchase agreement are more profitable. In this study, we used a choice experiment to determine the attributes affecting the participation rate in the power brokerage market for 113 renewable power owners and estimate the value of the power brokerage market. According to the estimation results, a low smart meter installation cost, low profit variations, long contract periods, and few clearances increased the probability of participation. Moreover, the average value of the power brokerage market was estimated to be 2.63 million KRW per power owner.

Sway Added Mass of a Rectangular Cylinder in a Restricted Water

  • Hwang, J.H.;Rhee, K.P.;Kang, C.K.
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.19 no.1
    • /
    • pp.3-14
    • /
    • 1982
  • In this paper, the sway added mass of a rectangular cylinder in a restricted water is considered by applying Hamilton's principle as the frequency tends to zero. The present method is an extension of Isshiki's method proposed in 1978. In the present method, it is assumed that the fluid velocity distribution in each subdomain of the fluid can be represented by higher order polynomials while Isshiki assumed linear velocity distribution. The fluid flow is assumed as a rotational motion in the present analysis. However, the results obtained from the present method show good agreement with Bai's numerical results for the case of large clearances between a canal wall and a cylinder. From Kelvin's minimum energy theorem, we can see that the value of sway added mass obtained from the present method approaches the upper bound. The approximate formula obtained in the present study takes a simple form which consists of the dimensions of the canal and the cylinder. The present formulae are derived for the cases of a rectangular cylinder swaying at the center of a narrow or wide canal relative to a cylinder, at off-center location in a canal, and in the restricted water with a single wall. From the results of numerical calculation, it is concluded that the sway added mass in restricted waters is more affected by water depth than clearance between a wall and a cylinder.

  • PDF

Variation of Operating Clearance Depending on Cooling Methods of High-Speed Roller Bearings for Aerospace Applications (항공용 고속 롤러베어링의 냉각 방식에 따른 작동간극 변화)

  • Jisu Park
    • Tribology and Lubricants
    • /
    • v.39 no.4
    • /
    • pp.123-132
    • /
    • 2023
  • In this study, the expansion, stress, and operating clearance of bearing elements during operation are observed using the inner/outer ring temperature test data of a 3.0×106 DN-class roller bearing. The operating clearance characteristics of inner-/outer-ring cooling (IORC) bearings are compared to those of inner-ring cooling (IRC) bearings. For IRC bearings, the thermal expansion of the outer ring is the most important factor in clearance variation. As a result, the operating clearance is less than the initial clearance of 61 ㎛, and the operating clearance decreases to 0.5 ㎛ at 25,500 rpm. Conversely, the temperature of the outer ring of IORC bearings is lower than that of IRC bearings, so the operating clearance is kept smaller. When the coolant flow rate to the outer ring is approximately 1.5 to 2.0 L/min, the temperature difference between the inner and outer rings is minimized and the operating clearance is maintained at a significantly lower level than IRC bearings. Small operating clearances are expected to be effective in reducing cage slip and skid damage in roller bearings. The results and analysis procedures of this study can be utilized to design of bearing clearance, lubricant flow rate, and assembled interference in the early design stage of aerospace roller bearings.

Approach towards qualification of TCP/IP network components of PFBR

  • Aditya Gour;Tom Mathews;R.P. Behera
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.3975-3984
    • /
    • 2022
  • Distributed control system architecture is adopted for I&C systems of Prototype Fast Breeder Reactor, where the geographically distributed control systems are connected to centralized servers & display stations via switched Ethernet networks. TCP/IP communication plays a significant role in the successful operations of this architecture. The communication tasks at control nodes are taken care by TCP/IP offload modules; local area switched network is realized using layer-2/3 switches, which are finally connected to network interfaces of centralized servers & display stations. Safety, security, reliability, and fault tolerance of control systems used for safety-related applications of nuclear power plants is ensured by indigenous design and qualification as per guidelines laid down by regulatory authorities. In the case of commercially available components, appropriate suitability analysis is required for getting the operation clearances from regulatory authorities. This paper details the proposed approach for the suitability analysis of TCP/IP communication nodes, including control systems at the field, network switches, and servers/display stations. Development of test platform using commercially available tools and diagnostics software engineered for control nodes/display stations are described. Each TCP link behavior with impaired packets and multiple traffic loads is described, followed by benchmarking of the network switch's routing characteristics and security features.

Characteristics of Ti Platinization for Fabrication Sn-modified Platinized Ti Electrode (Sn-modified Platinized Ti 전극 제조를 위한 Ti의 백금 도금 특성)

  • Kim, Kwang-Wook;Kim, Seong-Min;Lee, Eil-Hee
    • Korean Chemical Engineering Research
    • /
    • v.45 no.2
    • /
    • pp.124-132
    • /
    • 2007
  • This work investigated a fabrication way of stable platinized Ti electrode and evaluated the electrochemical characteristics of the Sn-modified platinized Ti electrode in nitrate solution. A Pt electro-plating way to form some open special clearances within the Pt coating layer on etched Ti substrate was very important to remove effectively the residual contaminate due to plating solution out of the fabricated electrode surface and to maximize the actual electrode surface area contacting solution. Both boiling and electro-cleaning processes of the fabricated electrode was essential to obtain a stable platinized-Pt electrode with reproducible and stable surface property which was necessary for the correct evaluation of Sn coverage on the electrode. The electro-cleaning caused a morphology change of the platinized Ti electrode surface with some downy hair-like polyps formed during the deposition disappearing, which made the electrode stable. The Sn-modified platinized Ti electrode in this work showed the best electro-activity for nitrate reduction, when it was fabricated through the Pt electro-plating of about 30 minutes.

Wind Tunnel Test on the Aerodynamic Characteristics of a PARWIG Craft (PARWIG선의 공력특성에 관한 풍동실험)

  • H.H. Chun;J.H. Chang;K.J. Paik;M.S. Shin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.37 no.3
    • /
    • pp.57-68
    • /
    • 2000
  • The Power Augmented Ram(PAR) effect, which blows the down stream of the propellers into the underside of the wings and hence increases the pressure between the lower surface of the wings and the sea surface, is known significantly to enhance the performance of the WIG concept by reducing the take-off and landing speeds. The aerodynamic characteristics of a 20 passenger PARWIG are investigated by wind tunnel tests with the 1/20 scale model. The efflux of the forward mounted propellers are simulated by jet flows with a blower and duct system. The lift, drag, and pitch moment of the model with various ground clearances, angles of attack and flap angles are measured for the various jet velocities, jet nozzle angles, horizontal and vertical positions of the nozzle, and the nozzle diameters. The aerodynamic characteristics of the PARWIG due to these parametric changes are compared and pertinent discussions are included. It is shown that the proper use of the PAR can increase the lift coefficient of as much as up to 4.

  • PDF

Pharmacokinetics of Tobramycin in Patients with Hematologic Malignancy (혈액암 환자에 있어서의 Tobramycin Pharmacokinetics)

  • Yeom, Mikyong;Shin, Wan-Gyoon;Lee, Min-Hwa
    • Korean Journal of Clinical Pharmacy
    • /
    • v.1 no.1
    • /
    • pp.31-36
    • /
    • 1991
  • Tobramycin is one of the most frequently selected agents for pharmacokinetic drug monitoring because of its narrow therapeutic index and essential role for the management of serious infections, especially gram-negative infections. Its pharmacokinetic parameters are dependent on race, sex, age, ideal body weight. disease states, and etc. Therefore, to schedule the dosing of tobramycin, the individual pharmacokinetic parameters such as half-life and volume of distribution are needed. However, these pharmacokinetic parameters have never been reported in Koreans. The purposes of this study were to evaluate the volume of distribution of tobramycin in cancer patients who had normal renal function, to compare the mean values of Vd reported in the literature, and to compare the measured half-life with the expected half-life based on ABW, LBW, and IBW, respectively. Venous blood samples were collected just before and thirty minutes after dosing during steady state. Serum tobramycin concentrations were determined by $TD_x$ (fluorescence immunoassay). IBW were measured by the method of Devine: and LBW were measured by the method of Hallynck. Creatinine clearances (CLcr) of the patients were estimated using the Cockcroft and Gault equation. Elimination rate constants (kel) were determined using the Welling and Craig equation. Infusion rate (ko), volume of distribution (Vd), and half-life $(t_{1/2})$ were determined using the Saw chuk and Zaske equation. The volume of distribution Was $27\%$ greater than the Schentag's study (0.26 vs 0.33 l/kg), but the half-life was similar to the Levy's study. The predicted half-lives based on IBW were the closest to actual half-lives (1.85 vs 2.01 hr).

  • PDF

A Study on Partial Admission Characteristics of a Multi-Stage Small-Scaled Turbine (다단 소형 터빈에서의 부분분사 특성에 관한 연구)

  • Cho, Chong-Hyun;Jeong, Woo-Chun;Kim, Chae-Sil;Cho, Soo-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.9
    • /
    • pp.943-954
    • /
    • 2010
  • In this study, a radial inflow type turbine was applied and the outer diameter of the turbine rotor was 108 mm. The turbine blade on a circular plate disc was designed as an axial-type because its partial admission rate was 1.4-4.1%. The turbine consisted of three stages. The performance test has been conducted with various admission rates, tip clearances and nozzle flow angles. The turbine output power was measured on each stage. The turbine performance was obtained in a wide rotational speed range in order to compare its performance according to various operating conditions. The net specific output torque was also measured to compare its overall performance. Computational analysis was conducted for predicting turbine performance. The computed results were in good agreement with the experimental results.