• 제목/요약/키워드: Clearance Level

검색결과 213건 처리시간 0.022초

환경물질을 제외한 전자부품의 신뢰성평가 방법 연구 -Pb와 Br을 제거한 PWB를 중심으로- (Reliability Assessment Methods for Electronic Component Removed Environmental Materials - focused on Printed Wiring Board without Pb and Br -)

  • 이종범;조재립
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제5권2호
    • /
    • pp.241-259
    • /
    • 2005
  • The environmental problem is a main subject of the 21C and an environment destruction phenomenon by various kinds of environmental materials is reaching serious level. Nations to be classified as the environmental developed country, are born again environmental rich country. And they earn a large income by trade Every kind environmental resource in an international commercial transaction. Especially, the study that a reliability assessment method to prevent to reliability problem to be happened when the solder lead(lead-free solder), non-cd component, non-bromide component(without the polybrominated biphenyls(PBB) and polybrominated diphenyl ethers(PBDE))and hexavalent chromium(Cr VI) clearance component and mercury-free applied to electronic equipment is progressed. As the result of the study for applying of a reliability assessment technique of lead-free solder that recognized the most of urgent problem at the company, combination accelerated life test could taken by adding and appling the part of a humidity acceleration part to Eyring Model which is proposed by R.E.Thomas. The reliability assessment methods study of PWB clean environmental materials is expected to respond to a reliability elevation and environmental material regulation policy spreading all over the world by beginning form Europe.

  • PDF

전향 축류형 홴에서의 익단 누설 유동 구조 (Structure of Tip Leakage Flow in a Forward-Swept Axial-Flow Fan)

  • 이공희;명환주;백제현
    • 대한기계학회논문집B
    • /
    • 제27권7호
    • /
    • pp.883-892
    • /
    • 2003
  • The experiment using three-dimensional laser Dopperr velocimetery (LDV) measurements and the computation using the Reynolds stress model of the commercial code, FLUENT, were conducted to give a clear understanding on the structure of tip leakage flow in a forward-swept axial-flow fan operating at the maximum efficiency condition. The tip leakage vortex was generated near the position of the minimum wall static pressure, which was located at approximately 12% chord downstream from the leading edge of blade suction side, and developed along the centerline of the pressure trough within the blade passages. A reverse flow between the blade tip region and the casing, induced by tip leakage vortex, acted as a blockage on the through-flow. As a result, high momentum flux was observed below the tip leakage vortex. As the tip leakage vortex proceeded to the aft part of the blade passage, the strength of tip leakage vortex decreased due to the strong interaction with the through-flow and casing boundary layer, and the diffusion of tip leakage vortex caused by high turbulence. In comparison with LDV measurement data, the computed results predicted the complex viscous flow patterns inside the tip region, including the locus of tip leakage vortex center, in a reliable level.

Sepsis Mortality in CIITA Deficient Mice is Associated with Excessive Release of High-mobility Group Box 1

  • Kim, Ji-Young;Kim, Ju-Hyun;Seo, Jae-Nam;Oh, Kwon-Ik
    • IMMUNE NETWORK
    • /
    • 제8권2호
    • /
    • pp.39-45
    • /
    • 2008
  • Background: Down regulation of major histocompatibility complex class II transactivator (CIITA) has been identified as a major factor of immunosuppression in sepsis and the level of CIITA expression inversely correlates with the degree of severity. However, it has not been fully elucidated whether the lower expression of CIITA is a cause of disease process or a just associated sign. Here we determined whether the CIITA deficiency decreased survival rate using murine sepsis model. Methods: Major histocompatibility complex class II (MHC-II) deficient, CIITA deficient and wild type B6 mice were subjected to cecal ligation puncture (CLP) surgery. CIITA and recombination activation gene (RAG)-1 double deficient mice were generated to test the role of lymphocytes in CIITA-associated sepsis progression. Results: Sepsis mortality was enhanced in CIITA deficient mice, not by impaired bacterial clearance resulted from CD4 T cell depletion, but hyper-inflammatory response such as excessive release of a pro-inflammatory cytokine, high-mobility group box 1 (HMGB1). Conclusion: Our results demonstrate that CIITA deficiency affects the course of sepsis via the unexpected function of CIITA, regulation of cytokine release.

임파종환자에서 반코마이신의 임상약물동태 (Clinical Pharmacokinetics of Vancomycin in Lymphoma Patients and Normal Volunteers)

  • 김재호;최준식;이진환
    • 한국임상약학회지
    • /
    • 제9권2호
    • /
    • pp.88-91
    • /
    • 1999
  • The purpose of this study was to compare the pkarmacokinetic parameters of vancomycin using a 2-compartment model in 8 Korean healthy volunteers and 8 lymphoma patients. Vancomycin (1.0 g) was administered by IV infusion over 60 minutes. The $\beta-phase$ rate constant $(\beta)$, apparent volume of distribution at steady srate $(V_{ss})$, total body clearance (CL) and area under the plasma level-time curve (AUC) of vancomycin in healthy volunteers were $0.15\pm0.02\;hr^{-1},\;33.8\pm4.12\;L/kg,\;5.36\pm0.61\;L/hr\;and\;185.8\pm20.5\;{\mu}g/ml{\cdot}hr$, respectively. The corresponding values in lymphoma patients ere $0.09\pm0.02\;hr^{-1},\;38.2\pm5.11\;L/kg,\;4.58\pm0.52\;L/hr\;and\;218.3\pm22.9\;{\mu}g/ml{\cdot}hr$. There were significant differences (p<0.05) in ${\beta}$ and CL between healthy volunteers and lymphoma patients.

  • PDF

자율주행 자동차의 제어권 전환 시간 확보를 위한 차간 통신 기반 종방향 제어 알고리즘 개발 (Development of a Longitudinal Control Algorithm based on V2V Communication for Ensuring Takeover Time of Autonomous Vehicle)

  • 이혜원;송태준;윤영민;오광석;이경수
    • 자동차안전학회지
    • /
    • 제12권1호
    • /
    • pp.15-25
    • /
    • 2020
  • This paper presents a longitudinal control algorithm for ensuring takeover time of autonomous vehicle using V2V communication. In the autonomous driving of more than level 3, autonomous systems should control the vehicles by itself partially. However if the driver's intervention is required for functional safety, the driver should take over the control reasonably. Autonomous driving system has to be designed so that drivers can take over the control from autonomous vehicle reasonably for driving safety. In this study, control algorithm considering takeover time has been developed based on computation method of takeover time. Takeover time is analysed by conditions of longitudinal velocity of preceding vehicle in time-velocity plane. In addition, desired clearance is derived based on takeover time. The performance evaluation of the proposed algorithm in this study was conducted using 3D vehicle model with actual driving data in Matlab/Simulink environment. The results of the performance evaluation show that the longitudinal control algorithm can control while securing takeover time reasonably.

환경물질을 제외한 전자부품의 신뢰성평가 방법 연구 -Pb와 Br을 제거한 PWB를 중심으로- (Reliability Assessment Methods for Electronic Component Removed Environmental Materials - focused on Printed Wiring Board without Pb and Br -)

  • 이종범;조재립
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2005년도 학술발표대회 논문집
    • /
    • pp.393-404
    • /
    • 2005
  • The environmental problem is a main subject of the 21C and an environment destruction phenomenon by various kinds of environmental materials is reaching serious level. Nations to be classified as the environmental developed country, are born again environmental rich country. And they earn a large income by trade Every kind environmental resource in an international commercial transaction. Especially, the study that a reliability assessment method to prevent to reliability problem to be happened when the solder lead(lead-free solder), non-cd component, non-bromide component(without the polybrominated biphenyls(PBB) and polybrominated diphenyl ethers(PBDE))and hexavalent chromium(Cr VI) clearance component and mercury-free applied to electronic equipment is progressed. As the result of the study for applying of a reliability assessment technique of lead-free solder that recognized the most of urgent problem at the company, combination accelerated life test could taken by adding and appling the part of a humidity acceleration part to Eyring Model which is proposed by R.E.Thomas. The reliability assessment methods study of PWB clean environmental materials is expected to respond to a reliability elevation and environmental material regulation policy spreading all over the world by beginning form Europe.

  • PDF

Proposing a Simple Radiation Scale for the Public: Radiation Index

  • Cho, Gyuseong;Kim, Jong Hyun;Park, Tae Soon;Cho, Kunwoo
    • Nuclear Engineering and Technology
    • /
    • 제49권3호
    • /
    • pp.598-608
    • /
    • 2017
  • A new radiation scale is proposed. With empathy toward the vast majority of people who are not well versed in radiation and related matters, and thus suffering from misunderstanding that breeds unnecessary fear of radiation, the aim of proposing a new radiation scale, radiation index (RAIN), is to put the general public at ease with the concept of radiation. RAIN is defined in dimensionless numbers that relate any specific radiation dose to a properly defined reference level. As RAIN is expressed in plain numbers without an attached scientific unit, the public will feel comfortable with its friendly look, which in turn should help them understand radiation dose levels easily and allay their anxieties about radiation. The expanded awareness and proper understanding of radiation will empower the public to feel that they are not hopeless victims of radiation. The correspondence between RAIN and the specific accumulated dose is established. The equivalence will allow RAIN to serve as a common language of communication for the general public with which they can converse with radiation experts to discuss matters related to radiation safety, radiation diagnosis and therapy, nuclear accidents, and other related matters. Such fruitful dialogues will ultimately enhance public acceptance of radiation and associated technologies.

재사용 파이프서포트(V2)의 품질관리 향상에 관한 연구 (A Study on Quality Management Improvement of Used Pipe Support(V2))

  • 박종근;최명기
    • 한국안전학회지
    • /
    • 제34권3호
    • /
    • pp.36-41
    • /
    • 2019
  • As the prefabricated shoring system structure, which is a temporary structure, is often collapsed due to various reasons during concrete pouring, and directly affects not only the safety of the workers but also the quality of the final building, it is necessary to ensure the safety. It is considered that the pipe supports which are widely used as the prefabricated shoring materials in the construction site do not satisfy the performance criteria in many cases. Therefore, this study investigated the detailed conditions for satisfying the performance criteria and suggested the factors for improving the quality control level in order to prevent collapse accidents due to pipe supports reused at the construction site, As the results of test in order to understand the effect of the pipe supports (V2), which are being reused in the field, on the performance by factor, the performance was evaluated to be high in case of the small female screw clearance and the supporting pin with 12mm in diameter or larger.

Quantification of Fargesin in Mouse Plasma Using Liquid Chromatography-High Resolution Mass Spectrometry: Application to Pharmacokinetics of Fargesin in Mice

  • Lee, Min Seo;Lim, Chang Ho;Bang, Young Yoon;Lee, Hye Suk
    • Mass Spectrometry Letters
    • /
    • 제13권1호
    • /
    • pp.20-25
    • /
    • 2022
  • Fargesin, a tetrahydrofurofuranoid lignan isolated from Flos Magnoliae, shows anti-inflammatory, anti-oxidative, anti-allergic, and anti-hypertensive activities. To evaluate the pharmacokinetics of fargesin in mice, a sensitive, simple, and selective liquid chromatography-high resolution mass spectrometric method using electrospray ionization and parallel reaction monitoring mode was developed and validated for the quantification of fargesin in mouse plasma. Protein precipitation of 6 µL mouse plasma with methanol was used as sample clean-up procedure. The standard curve was linear over the range of 0.2-500 ng/mL in mouse plasma with the lower limit of quantification level at 0.2 ng/mL. The intra- and inter-day coefficient variations and accuracies for fargesin at four quality control concentrations including were 3.6-11.3% and 90.0-106.6%, respectively. Intravenously injected fargesin disappeared rapidly from the plasma with high clearance values (53.2-55.5 mL/min/kg) at 1, 2, and 4 mg/kg doses. Absolute bioavailability of fargesin was 4.1-9.6% after oral administration of fargesin at doses of 1, 2, and 4 mg/kg to mice.

Do jejunal veins matter during pancreaticoduodenectomy?

  • Mee Joo Kang;Sung-Sik Han;Sang-Jae Park;Hyeong Min Park;Sun-Whe Kim
    • 한국간담췌외과학회지
    • /
    • 제26권3호
    • /
    • pp.229-234
    • /
    • 2022
  • When planning pancreaticoduodenectomy for pancreatic head cancer, the prevalence of anatomical variation of the proximal jejunal vein (PJV), the associated short-term surgical outcomes, and the level of PJV convergence to the superior mesenteric vein must be carefully analyzed from both technical and oncological points of view. The prevalence of the first jejunal trunk (FJT) and PJV located ventral to the superior mesenteric artery is 58%-88% and 13%-37%, respectively. Patients with the FJT had a larger amount of intraoperative bleeding and a higher proportion of patients requiring transfusions compared to those without a common trunk. The risk of transfusion was higher in patients with ventral PJV compared to those with dorsal PJV. Although less frequent, sacrificing the FJT can result in fatal venous congestion of the jejunum. Therefore, a well-planned approach for pancreaticoduodenectomy, based on preoperative evaluation of anatomical variation in the PJV, may help reduce intraoperative bleeding and postoperative morbidity. Additionally, the importance of invasion into the PJVs should be revisited in terms of resectability and oncological clearance.