• Title/Summary/Keyword: Clear heat

Search Result 357, Processing Time 0.033 seconds

Analysis of herbal formulation about a series of Chijasi-tang in Dongeuibogam (동의보감(東醫寶鑑)에 수록된 치자시탕(梔子豉湯) 가미방(加味方) 분석(分析))

  • JeGal, Kyung-Hwan;Kim, Young-Woo;Byun, Sung-Hui
    • Herbal Formula Science
    • /
    • v.20 no.2
    • /
    • pp.177-186
    • /
    • 2012
  • In this study, we selected some herbal formulation about a series of Chijasi-tang in Dongeuibogam by using web-based open program;Prescription Lineage Graph (http://164.125.206.43/PrescriptionLineageGraph.aspx). And we compared and analyzed the changes of efficacy, major target symptoms of each herbal formulation according to compositional variation of each herbal formulation. Chijasi-tang, first appeared in Sanghanlun, consists of Capejasmine and Fermented soybean, and it is mainly used to treat insomnia due to vexation, heartburn and yellow greasy tongue fur. Capejasmine can clear away irritable feverish sensation in chest by flowing downward the heat, and Fermented soybean can disperse stagnated heat throughout the chest by expelling stagnated heat from the exterior In the case of the heat stagnation caused by relapsing of disease due to overstain, Chisijisil-tang can be used. And if symptom appear more on the upper or exterior than a case of Chisijisil-tang, Seosisi-tang could be more suitable, if half exterior and half interior, Omae-tang could be for it. In addition, if symptom caused by relapsing due to improper diet, Chisijihwang-tang could be proper formulation. In the case of the heat stagnation body inside and jaundice, if it is caused by alcohol, Chijadaehwang-tang could be used for the purpose of urgent purgation, Galchul-tang would be suitable for helping the function of the spleen and the stomach and for treatment of damp-heat of the spleen and the stomach. And if it is caused by pandemic infection, Jangdal-hwan would be good formulation for it. Samhwangseokgo-tang and Yangdokchija-tang could be appropriate formulation for the raging of noxious heat and pathogenic fire caused by febrile disease with toxic yang. Daehwangeum-ja is for severe constipation due to heat-dryness with stagnated fever, Haebaek-tang is appropriate for severe diarrhea due to heat type change of Soeum. According to the result of our investigation, although there are various target causes and symptoms of each herbal formulations, whatever pathogenetic cause is, the stagnated heat in interior side is the basis of symptoms. Therefore, the purpose of including Chijasi-tang in composition of each herbal formulation is treatment of the stagnated heat. For such reason, on the fundamental or ancillary basis of Chijasi-tang plus some herbs for each therapeutic purpose.

Finite Element Analysis on Heat of Hydration with Reinforcing Steel Bars (철근의 영향을 고려한 수화열 유한요소해석)

  • Yoon Dong-Yong;Yang Ok-Bin;Min Chang-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.1 s.85
    • /
    • pp.43-49
    • /
    • 2005
  • In the concrete structures, the magnitude and distribution of the temperature due to the heat of hydration are related to the thermal properties of each component composed of the concrete, the initial temperature, the type of formwork, and the ambient temperature of exposed surfaces. Even though the reinforcing steel bar has completely different thermal properties, it has been excluded. In the thermal analysis on the concrete structures. In this study, finite element analysis was performed on the concrete structures including the reinforcing steel in order to investigate their effect on temperature and stress distribution due to the heat of hydration. As the steel ratio increased, the maximum temperature and the internal-external temperature difference decreased by 32.5% and 10%, respectively. It is clear that the inclusion of reinforcing steel bars on the heat of hydration analysis is indispensable to obtain realistic solutions for the prediction of the maximum temperature and stresses

A Research on the Epidermic disease of Abdominal Impulse etc. in SangHanMyungRiSokLon (상한명리속론(傷寒明理續論).동기(動氣)외 8증(證)에 대한 연구(硏究))

  • Shin, Je-Sung;Sheen, Yeong-Il
    • Journal of Korean Medical classics
    • /
    • v.19 no.2 s.33
    • /
    • pp.248-265
    • /
    • 2006
  • Impulse of ki refers to palpitation around the navel, it is mostly caused by impairment of yang due to erroneous sweating, deficiency of the spleen yang. Behcet's syndrome caused by prolonged damp-heat and pathogenic germs. Its symptoms are characterized by conjunctival congestion, blue canthus and ulceration of the oral cavity, restlessness all the time, etc. It is advisable to follow the therapeutic principles of clearing away heat and drying damp, detoxicating and sterilizing. Lily disease is one of the emotional disease. It caused by yin deficiency of the heart and lung, found in mental depression or convalescence after a critical disease. Its symptoms are characterized by restlessness, reticence, insomnia, failure to walk, poor appetite, a subjective hot or cold, bitter taste and dark urine. It is advisable to follow the therapeutic principle of nourishing yin to clear away heat. Cholera refers to the disease marked by sudden severe vomiting and diarrhea, and colic of the heart and the abdomen. It is mostly caused by deficiency of the ki in the middle-energizer, emotional stress, etc. It is characterized by such symptoms as sudden severe vomiting and diarrhea, restlessness, etc. It is advisable to follow the therapeutic principles of warming yang and removing toxic substances, and strengthening the spleen and stomach. Heat invasion of blood chamber due to affection of the exterior pathogens, pathogenic heat invading the blood in deficiency and fighting with the blood. Its symptoms are marked by fever, feeling of the fullness, etc. There are deficiency of blood, hot blood and stasis of blood. The different therapeutic treatment should be taken according to different types thereof.

  • PDF

A Case Study on Field Construction of Cold Weather Mass Concreting Using Double Bubble Sheets and Hydration Heat Difference Method (이중 버블시트 및 수화발열량차 공법에 의한 한중매스콘크리트의 현장적용 연구)

  • Kim Jong;Yoon Jae-Ryung;Jeon Chung-Keun;Shin Dong-An;Oh Seon-Gyo;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.15-18
    • /
    • 2006
  • The test result of mat concrete applying both hydration heat difference and insulation curing method on new construction of Cheongju university educational building are summarized as following. Both fresh concrete and compressive strength properties were satisfied In aimed value. Setting time of concrete incorporating 15% of fly ash(FA) retarded 1.2 hour than control concrete. Temperature history of mali concrete indicated that the highest temperature of center was exhibited at $126^{\circ}C$ after 51 hours while the highest temperature of upper section was $10.6^{\circ}C$ after 46 hours. Temperature Difference between center and surface was managed at less than $6^{\circ}C$ during whole curing period. In addition the temperature of upper section secured more than $3.3^{\circ}C$ while the temperature of outside was indicated at less than $-10^{\circ}C$. Maturity by parts of construction secured more than $30^{\circ}C$ DD higher than outside at 3 days. The more number of times, applying insulation curing method by double bubble sheets, increased, the higher economic effect was secured. Overall it was clear that applying both double bubble sheets and hydration heat difference method on this new construction can resist hydration heat crack, early frost demage and strength decrease. It also significantly contributed quality improvement of cold weather concreting

  • PDF

Heat transfer characteristics with materials of the filler and flow path in vehicle washer heater system (차량워셔액 가열시스템에서 충전재 및 유로의 재질에 따른 열전달 특성 연구)

  • Cha, Woo Sub;Kim, Tae Kwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2628-2634
    • /
    • 2014
  • Vehicle washer heater system is more widely adopted to defrost a window or to clear the windshield glass in winter season. The washer heater system should be designed to heat up washer fluid rapidly to the target temperature for only a short time. A numerical analysis has been carried out to analyze the heat transfer characteristics with materials of inside parts in vehicle washer heater system with filler and flow path. ANSYS - FLUENT software is employed for the analysis. The axial symmetry model is three-dimensional and unsteady. It applies to the coupled method which is one of pressure based. Through this result, it was obtained to find the optimal material condition for the filler and flow path in washer system. For material of filler, the air with lower density was heated more rapidly rather than silicon carbide(SiC). For material of flow path, copper with the heat transfer coefficient of approximately four times greater than the nickel gives us higher efficiency. That is the reason why the heating time of methanol was reduced to make uniform temperature in washer heater system.

Non Destructive Technique for Steel Corrosion Detection Using Heat Induction and IR Thermography (열유도 장치와 적외선 열화상을 이용한 철근부식탐지 비파괴 평가기법)

  • Kwon, Seung Jun;Park, Sang Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.2
    • /
    • pp.40-48
    • /
    • 2012
  • Steel corrosion in concrete is a main cause of deterioration and early failure of concrete structures. A novel integration of electromagnetic heat induction and infrared (IR) thermography is proposed for nondestructive detection of steel corrosion in concrete, by taking advantage of the difference in thermal characteristics of corroded and non-corroded steel. This paper focuses on experimental investigation of the concept. An inductive heater is developed to remotely heat the embedded steel from concrete surface, which is integrated with an IR camera. Concrete samples with different cover depths are prepared. Each sample is embedded with a single rebar in the middle, resulting an identical cover depth from the front and the back surfaces, which enable heat induction from one surface and IR imaging from the other simultaneously. The impressed current (IC) method is adopted to induce accelerated corrosion on the rebar. IR video images are recorded during the entire heating and cooling periods. The test results demonstrate a clear difference in thermal characteristics between corroded and non-corroded samples. The corroded sample shows higher rates of heating and cooling than those of the non-corroded sample. This study demonstrates a potential for nondestructive detection of rebar corrosion in concrete.

The Efficiency of External Heat Sources for Infrared Thermography Applied Concrete Structures and the Improvement of the Defect-identification (열화상 기법을 이용한 콘크리트 구조물 결함 검출시 열원의 효율 비교 및 결함검출 능력 향상)

  • Sim, Jun-Gi;Moon, Do-Young;Chung, Lan;Lee, Jong-Seh;Zi, Goangseup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.5 s.57
    • /
    • pp.169-179
    • /
    • 2009
  • The purpose of this paper is to find an efficient heat source to amplify the surface temperature of damaged concrete structures for infrared thermography. we compare two different heat sources of far-infrared lamp and halogen lamp each other for their efficiency. The two heat sources were applied to the concrete specimens. Two different concrete specimens were used: one was the concrete containing internal void and the other was wrapped with partially unbonded fiber reinforced polymer sheet. it was found that the far-infrared lamp was more efficient than the halogen lamp. In addition, we propose a new algorithm to make the damage zone displayed clear in the image obtained from the thermographic operation. The algorithm is a combination of Gauss filtering process and the Prewitt mask operation.

The Latent Heat Exchange on the Ground (지표면 잠열 이동에 관한 연구)

  • Lee, Bu-Yong;Haginoya, Shigenori
    • Journal of Environmental Science International
    • /
    • v.20 no.8
    • /
    • pp.1061-1068
    • /
    • 2011
  • Evapotranspiration is one of the important elements related water cycle and there is many kind of measurement method of evapotranspiration today. This study developed mini lysimeter for the purpose of direct measurement of evapotranspiration and installed on 5th, July, 2010 at the field of MRI which located at Tsukuba, Ibaraki, Japan for continuous measurement and understand relation between evapotranspiration and meteorological elements expecially radiation elements. And compared the evapotranspiration data of lysimeter with Bowen Ratio Method. The result of this study is as follows; There is high related with solar radiation and evapotranspiration with $R^2$=0.947. and 46 % of solar radiation converted into evapotranspiration during clear 5 days. In net radiation also highly related with evapotranspiration, we can derive evapotranspiration is mainly controlled by radiation energy in clear days. From the 104 days data, there is only 9 % difference between Bowen Ratio Method and evapotranspiration of lysimeter which was developed from this study is very useful to estimate evapotranspiration at field site with simple and high accuracy. High accuracy and resolution measurement of evapotranspiration by lysimeter can give a chance further study of meteorological phenomena of on ground expecially in night time condensation which means abnormal energy flow.

Synthesis, Crystallization Behaviors and Conductivity of $\beta$-Alumina from Aluminum Isopropoxide and Sodium Hydroxide (Aluminum Isopropoxide와 Sodium Hydroxide로부터 $\beta$-Alumina의 합성과 결정화 과정 및 전도도)

  • 양유철;박용민;김형욱;손영국
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.9
    • /
    • pp.1076-1084
    • /
    • 1995
  • A mixture of aluminum isopropoxide (Al(OC3H7i)3) solution and sodium hydroxide (NaOH) solution was hydrolyzed in the range between pH 1~14. the powder obtained from sol-gel process was calcined at several temperatures and crystallization behaviors of various samples were investigated. The hydrolyzed sols of pH 1~6 wre clear, or near clear. On the other hand, powder precipitated from sols of pH 7~14. The sample obtained from pH 3 solution crystallized via complicated route, and $\beta$-Al2O3 and $\beta$"-Al2O3 phases appeared at lower temperature than samples from other pH conditions. And the quantity of remained $\beta$"-Al2O3 phase after heat treatment at 150$0^{\circ}C$ was more than samples from other pH conditions. After sintering, ionic conductivities were 1.3$\times$10-4S.cm-1 to 0.76$\times$10-4S.cm-1.0-4S.cm-1.

  • PDF

Comparison of Marine Insolation Estimating Methods in the Adriatic Sea

  • Byun, Do-Seong;Pinardi, Nadia
    • Ocean Science Journal
    • /
    • v.42 no.4
    • /
    • pp.211-222
    • /
    • 2007
  • We compare insolation results calculated from two well-known empirical formulas (Socket and Beaudry's SB73 formula and the original Smithsonian (SMS) formula) and a radiative transfer model using input data predicted from meteorological weather-forecast models, and review the accuracy of each method. Comparison of annual mean daily irradiance values for clear-sky conditions between the two formulas shows that, relative to the SMS, the SB73 underestimates spring values by 9 W $m^{-2}$ in the northern Adriatic Sea, although overall there is a good agreement between the annual results calculated with the two formulas. We also elucidate the effect on SMS of changing the 'Sun-Earth distance factor (f)', a parameter which is commonly assumed to be constant in the oceanographic context. Results show that the mean daily solar radiation for clear-sky conditions in the northern Adriatic Sea can be reduced as much as 12 W $m^{-2}$ during summer due to a decrease in the f value. Lastly, surface irradiance values calculated from a simple radiative transfer model (GM02) for clear-sky conditions are compared to those from SB73 and SMS. Comparison with iu situ data in the northern Adriatic Sea shows that the GM02 estimate gives more realistic surface irradiance values than SMS, particularly during summer. Additionally, irradiance values calculated by GM02 using the buoy meteorological fields and ECMWF (The European Centre for Medium Range Weather Forecasts) meteorological data show the suitability of the ECMWF data usage. Through tests of GM02 sensitivity to key regional meteorological factors, we explore the main factors contributing significantly to a reduction in summertime solar irradiance in the Adriatic Sea.