Sludge Thickening Performance of the Filtration Bio-reactor Equipped with Shadow Mask Filter Module (Shadow mask 여과 모듈을 이용한 슬러지 농축 특성)

  • Jung, Yong-Jun;Kwon, Koo-Ho;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.29-33
    • /
    • 2005
  • In order to recycle the waste material and to develop the thickening unit of waste activated sludge from wastewater treatment facilities, the filtration bio-reactor equipped with a shadow mask filter module was employed for this work from which the operating properties and parameters were drawn. The sludge thickening and filtration unit is made of cylindrical acryl tank(12cm i.d. ${\times}$ 58cm height: working volume of 6L), where the flat-sheet type of shadow mask filter module(pore size: 220~250um, opening area: 34.8~39.6%) was installed and the effluent was withdrawn from the effluent port at the lowest point of the reactor, and the filtration was performed only by the hydraulic pressure. For evaluating the operating performance of this reactor, some parameters such as the solid-liquid separation of different biomass concentrations, the water quality of filtrate, the aeration cleaning time and the cleaning effect were investigated. Depending on the MLSS concentrations, the different time to withdraw 3L of filtrate was required in which the longer filtration time was necessary for the higher MLSS concentrations caused by the thicker formation of cake layer: 40 minutes for 5,000 mg/L, 70 minutes for 10,000 mg/L and 100 minutes for 15,000 mg/L, where the concentrations of SS were 8.9, 6.7 and 6.5 mg/L, respectively. Under the same operating conditions (the intensity of aeration cleaning: 80 L/min, MLSS: 10,000 mg/L), the proper aeration cleaning time was revealed 30 seconds, and the stable formation of cake layer was in the range of 10 to 15 minutes. Therefore, the shadow mask considered as a waste material can be of use as a filter material for the sludge thickening system.

Effect of cleaning process and surface morphology of silicon wafer for surface passivation enhancement of a-Si/c-Si heterojunction solar cells (실리콘 기판 습식 세정 및 표면 형상에 따른 a-Si:H/c-Si 이종접합 태양전지 패시배이션 특성)

  • Song, JunYong;Jeong, Daeyoung;Kim, Chan Seok;Park, Sang Hyun;Cho, Jun-Sik;Yun, Kyounghun;Song, Jinsoo;Lee, JeongChul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.99.2-99.2
    • /
    • 2010
  • This paper investigates the dependence of a-Si:H/c-Si passivation and heterojunction solar cell performances on various cleaning processes of silicon wafer and surface morphology. It is observed that passivation quality of a-Si:H thin-films on c-Si wafer highly depends on wafer surface conditions. The MCLT(Minority carrier life time) of wafer incorporating intrinsic (i) a-Si:H as a passivation layer shows sensitive variation with cleaning process and surface morpholgy. By applying improved cleaning processes and surface morphology we can obtain the MCLT of $200{\mu}sec$ after H-termination and above 1.5msec after i a-Si:H thin film deposition, which has implied open circuit voltage of 0.720V.

  • PDF

Comparison of physical cleaning applied to chemical backwashing of wastewater reuse membrane system (하수재이용 막여과 공정에서 약품 역세에서의 물리세정 영향 비교 평가)

  • Lee, Chang-Ha;Kim, Young-Hoon;Jeon, Min-Jung;Lee, Yong-Soo;Jang, Am;Kim Hyung-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.981-987
    • /
    • 2011
  • Biologically treated water contains a large quantity of organic matters and microorganisms which can cause various problems to membrane. The membrane fouling occurred by these reasons is hard to control by single physical cleaning. This study analyzes the efficiency of aeration with chemical backwashing and foulants removal during chemical backwashing. The cleaning efficiency improves when the chemical concentration is high and the contact time of chemical is long. Chemical backwashing with aeration shows exceptional cleaning efficiency which leads the physical cleaning is required during chemical backwashing since it forms flow inside the membrane submerged tank. From the foulants removal analysis, the particles such as turbidity and TOC removal rate increase when the aeration is applied. Dissolved matter of DOC and UV254 removal is dependent on higher chemical concentration. According to FTIR analysis, one of major foulants, the polysaccharide is controlled by the chemical backwashing with aeration condition.

Development of Wafer Cleaning Equipment Using Nano Bubble and Megasonic Ultrasound (나노 버블과 메가소닉 초음파를 이용한 반도체 웨이퍼 세정장치 개발)

  • Nohyu Kim;Sang Hoon Lee;Sang Yoon;Yong-Rae Jung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.4
    • /
    • pp.66-71
    • /
    • 2023
  • This paper describes a hybrid cleaning method of silicon wafer combining nano-bubble and ultrasound to remove sub-micron particles and contaminants with minimal damage to the wafer surface. In the megasonic cleaning process of semiconductor manufacturing, the cavitation induced by ultrasound can oscillate and collapse violently often with re-entrant jet formation leading to surface damage. The smaller size of cavitation bubbles leads to more stable oscillations with more thermal and viscous damping, thus to less erosive surface cleaning. In this study, ultrasonic energy was applied to the wafer surface in the DI water to excite nano-bubbles at resonance to remove contaminant particles from the surface. A patented nano-bubble generator was developed for the generation of nano-bubbles with concentration of 1×109 bubbles/ml and nominal nano-bubble diameter of 150 nm. Ultrasonic nano-bubble technology improved a contaminant removal efficiency more than 97% for artificial nano-sized particles of alumina and Latex with significant reduction in cleaning time without damage to the wafer surface.

  • PDF

Development of a Process for Clean-Washed Rice Processing (I) - Mass Balance Analysis - (씻지 않은 쌀의 가공 공정 개발 (I) - 질량수지 분석 -)

  • 장동일;한우석;김동철;이상효
    • Journal of Biosystems Engineering
    • /
    • v.24 no.4
    • /
    • pp.317-324
    • /
    • 1999
  • This study was conducted to decide several design criterion for clean-washed rice processing system development. A Computer simulation was used to predict and analyze the mass balances and moisture changes of the process of clean-washed rice processing system. The following results were obtained from this study. 1. In order to attain the processing capacity of 1,000kg/h of the clean-washed rice processing system, that of the system was designed as 1,400kg/h which was based on the safety factor of 40% and handling capability of mass variations occurred during processing. 2. It was analyzed that the proper time required for aqueous cleaning process should be within one minute. 2. It was analyzed that the proper time required for aqueous cleaning process should be within one minute. 3. The final moisture content of clean-washed rice was controlled being 15%(w.b.) for the sake of safe storage. 4. It was proven that the optimum drying time was three minutes for the clean-washed rice dried by a rotary dryer.

  • PDF

Design of Real Time Complex Proportion Method Automatic Chlorine Input System using RTOS (RTOS를 이용한 실시간 복합비례방식 자동 염소투입기 시스템 설계)

  • Kim, Si-Hwan;Lin, Chi-Ho
    • Journal of IKEEE
    • /
    • v.6 no.2 s.11
    • /
    • pp.146-151
    • /
    • 2002
  • This paper proposes a method that regulate a chlorine density to real time using RTOS. The most of a cleaning bed make use of the flux method to input chlorine. But, This method is difficult to control of chlorine's amount because Amount used of water is difference in each time or according to season. In this paper, we have designed a two method to flux and remain chlorine. Each task is programmed to cope with changeable external environment. The efficiency of the proposed system is shown by comparison results for performance of the proposal system with cleaning bed using a flux method.

  • PDF

Evaluation of adenosine triphosphate testing for on-farm cleanliness monitoring compared to microbiological testing in an empty pig farrowing unit

  • Yi, Seung-Won;Cho, Ara;Kim, Eunju;Oh, Sang-Ik;Roh, Jae Hee;Jung, Young-Hun;Choe, Changyong;Yoo, Jae Gyu;Do, Yoon Jung
    • Journal of Animal Science and Technology
    • /
    • v.62 no.5
    • /
    • pp.682-691
    • /
    • 2020
  • Careful cleaning and disinfection of pigpens is essential to prevent disease spread and avoid the resultant economic losses. Hygiene in pigpens is generally evaluated by visual monitoring supplemented with bacteriological monitoring, which includes counting the total aerobic bacteria (TAB) and/or fecal indicator bacteria (FIB). However, these methods present drawbacks such as time and labor requirements. As adenosine triphosphate (ATP) is ubiquitous in all living organisms including microorganisms, this study aimed to directly compare the results of microbial assessment and ATP quantification, and to suggest possible detailed application methods of the ATP test for hygiene evaluation in pigpens of a farrowing unit. Before and after standard cleaning procedures, samples were collected from the floor corner, floor center, and feeding trough of four pigpens at different time points. No FIB were detected and both the TAB and ATP levels were significantly decreased in the floor center area after cleaning. FIB were continuously detected after cleaning and disinfection of the floor corners, and there was no significant ATP level reduction. The feeding trough did not show any significant difference in these values before and after cleaning, indicating insufficient cleaning of this area. The levels of TAB and ATP after cleaning were significantly correlated and the average ATP value was significantly lower in the absence of FIB than in their presence. In the absence of standard references, a more thorough hygiene management could be achieved evenly by supplementing cleaning or disinfection based on the lowest ATP results obtained at the cleanest test site, which in the present study was the floor center. Overall, these results indicate that the on-farm ATP test can be used to determine the cleanliness status, in addition to visual inspection, as an alternative to laboratory culture-based testing for the presence of microorganisms.

Effects of Isothermal Stabilization Process and Ultrasonic Cleaning on the Characteristics of Rayon Fabrics (레이온직물의 특성에 미치는 등온 안정화공정 및 초음파세척의 영향)

  • Cho, Chaewook;Cho, Donghwan;Park, Jong Kyoo;Lee, Jae Yeol
    • Journal of Adhesion and Interface
    • /
    • v.14 no.1
    • /
    • pp.21-27
    • /
    • 2013
  • Cellulose-based rayon fibers or fabrics can be thermally decomposed very fast within a narrow temperature window during stabilization process. Therefore the stabilization stage is critically important for producing rayon-based carbon fibers. Consequently, in the present study the effects of isothermal stabilization and ultrasonic cleaning on the weight loss, chemical composition, microstructure, and fabric texture of cellulose-based rayon fabrics were explored. The temperature of the isothermal stabilization process performed in the range of $200{\sim}240^{\circ}C$ influenced the processing time, carbon and oxygen contents, cellulose structural change, and fabric texture. The ultrasonic cleaning, which was conducted prior to the stabilization process, played a role in shortening the stabilization time, increasing the carbon contents, decreasing the oxygen contents, and changing the XRD pattern. Also, it was considered that the ultrasonic cleaning contributed to retarding the weight loss, to reducing the thermal shrinkage, and further to reducing the fast physical change of rayon fabrics.

Ergonomics Job Hazard Evaluation of Building Cleaners

  • Lee, Kyung-Sun;Lee, In-Seok;Kim, Hyun-Joo;Jung-Choi, KyungHee;Bahk, Jin-Wook;Jung, Myung-Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.3
    • /
    • pp.427-435
    • /
    • 2011
  • Objective: The objective of this study was to evaluate a work of building cleaners using the ergonomic methods. Background: Previous studies about cleaning worker describe typical physical demands of this work. They found that the most significant risk factors associated with the physical work of cleaners are static loads and repetitive movements and high output of force. Method: A head of ergonomics estimation was work analysis(define of combined task, work tool, work time and frequency of combined task) and posture analysis of worker. Results: The results showed that combined task of building cleaners was classification sweeping, mopping(wet), mopping(oil), moving barrels/carts, dumping trash bags, scrubbing, arrangement of cleaning tool, arrangement of circumferential, moving of cleaning tool, and waiting. The work time of combined task such as mopping(wet) and scrubbing indicated high ratio. The posture analysis of building cleaners indicated high value in bending of the head, lower arm, and hands. Conclusion: The findings appear to indicate that building cleaner were related to high risk of work-related musculoskeletal disorders. So, building cleaner would be required an interventional strategy, improvement of cleaning tools and working environment. Application: If ergonomics rule can be integrated into existing cleaning tools and work environments, the risk of occupational injuries will be reduced.

Quantitative Real-Time PCR of Porcine Parvovirus as a Model Virus for Cleaning Validation of Chromatography during Manufacture of Plasma Derivatives (혈장분획제제 제조공정에서 크로마토그래피 세척 검증을 위한 모델바이러스로서의 Porcine Parvovirus 정량)

  • Kil Tae Gun;Kim Won Jung;Lee Dong Hyuk;Kang Yong;Sung Hark Mo;Yoo Si Hyung;Park Sue-Nie;Kim In Seop
    • Korean Journal of Microbiology
    • /
    • v.41 no.3
    • /
    • pp.216-224
    • /
    • 2005
  • Chromatography has now been used successfully to provide the requisite purity for human plasma-derived biop-harmaceuticals such as coagulation factors and immunoglobulins. Recently, increasing attention has been focused on establishing efficient cleaning procedures to prevent potential contamination by microorganisms as well as carry-over contamination from batch to batch. The purpose of present study was to develop a cleaning validation system for the assurance of virus removal and/or inactivation during chromatography process. In order to establish an assay system for the validation of virus clearance during chromatography cleaning process, a quantitative real-time PCR method for porcine parvovirus(PPV) was developed, since PPV, a model virus for human parvovirus B19, has a high resistance to a range of physico-chemical treatment. Specific primers for amplification of PPV DNA was selected, and PPV DNA was quantified by use of SYBR Green I. The sensitivity of the assay was calculated to be 1.5 $TCID_{50}/ml$. The established real-time PCR assay was successfully applied to the validation of PPV removal and cleaning during SP-Sepharose cation chromatography for thrombin purification and Q-Sepharose anion chromatography for factor VIII purification. The comparative results obtained by real-time PCR assay and infectivity titrations suggested that the real-time PCR assay could be a useful method for chromatography cleaning validation and that it could have an additive effect on the interpretation and evaluation of virus clearance during the virus removal process.