• Title/Summary/Keyword: Cleaning equipment

Search Result 204, Processing Time 0.027 seconds

A method for properties evaluation of activated charcoal sorbents in iodine capture under dynamic conditions

  • Magomedbekov, Eldar P.;Obruchikov, Alexander V.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.641-645
    • /
    • 2019
  • Experimental equipment for studying the sorption properties of iodine sorbents using radioactive methyliodide has been developed. The sorption capacity index ${\alpha}$ is proposed as a criterion parameter for assessing the quality of impregnated activated charcoals. It was found that this parameter does not depend on the dynamic conditions during the sorbent test. It was shown that values of the sorption capacity index allow to recommend iodine sorbents for industrial gas cleaning processes.

Tuberculosis Infection Control in Health-Care Facilities: Environmental Control and Personal Protection

  • Lee, Ji Yeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.79 no.4
    • /
    • pp.234-240
    • /
    • 2016
  • Transmission of tuberculosis (TB) is a recognized risk to patients and healthcare workers in healthcare settings. The literature review suggests that implementation of combination control measures reduces the risk of TB transmission. Guidelines suggest a three-level hierarchy of controls including administrative, environmental, and respiratory protection. Among environmental controls, installation of ventilation systems is a priority because ventilation reduces the number of infectious particles in the air. Natural ventilation is cost-effective but depends on climatic conditions. Supplemented intervention such as air-cleaning methods including high efficiency particulate air filtration and ultraviolet germicidal irradiation should be considered in areas where adequate ventilation is difficult to achieve. Personal protective equipment including particulate respirators provides additional benefit when administrative and environmental controls cannot assure protection.

Design of a Monitoring System for Controlling the Wet Station Equipment (Wet Station 장비를 제어하기 위한 모니터링 시스템의 설계)

  • Im, Seong-Rak;Han, Gwang-Rok;Choe, Yong-Yeop
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.5
    • /
    • pp.1385-1392
    • /
    • 1999
  • This paper describes the design of the monitoring system for monitoring the current status and indirect controlling of the Wet Station Equipment which is used for cleaning the wafer. Most of the conventional monitoring system depend on the special hardware and software. Basic design goal of monitoring system is provide the convenience for the use and the portability for the system. In order for the system to fulfil its requirements, it was designed using GUI (Graphical User Interface) facility based on the windows NT environment of IBM PC compatible and EtherNet board based on the TCP/IP protocol.

  • PDF

Exposure Assessment of Dust, Ultra Fine Dust(Particulate Matter 2.5, PM2.5) and Black Carbon among Aircraft Cabin Cleaners (항공기 기내 청소노동자의 분진, 초미세먼지(PM2.5) 및 블랙카본 노출수준 평가)

  • Hyunhee Park;Sedong Kim;Sungho Kim;Seung-Hyun Park
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.2
    • /
    • pp.171-187
    • /
    • 2023
  • Objectives: Aircraft cabin cleaning work is characterized by being performed within a limited time in a narrow and enclosed space. The objective of this study was to evaluate the exposure levels to dust, ultra fine dust(PM2.5) and black carbon(BC) among aircraft cabin cleaners. Methods: Active personal air sampling for respirable dust(n=73) and BC(n=47) was conducted during quick transit cleaning(cabin general and vacuum-specific) and seat cover replacement and total dust and PM2.5 were area-air-sampled as well. Also, size distribution of particle was identified with the cleaning workers targeted. Dusts were collected with PVC filters using gravimetric analysis. The concentration of PM2.5 and the particle size distribution were measured with real-time direct reading portable equipment using light scattering analysis. The concentration of BC was measured by aethalometer(filter-based real-time light absorption analysis instrument). Results: The geometric mean of respirable dust was the highest at vacuum cleaning as 74.4 ㎍/m3, following by replacing seat covers as 49.3 ㎍/m3 and cabin general cleaning as 47.8 ㎍/m3 . The arithmetic mean of PM2.5 was 4.83 ~ 9.89 ㎍/m3 inside the cabin, and 28.5~44.5 ㎍/m3 outside the cabin(from bus and outdoor waiting space). From size distribution, PM2.5/PM10 ratio was 0.54 at quick transit cleaning and 0.41 at replacing seat covers. The average concentration of BC was 2~7 ㎍/m3, showing a high correlation with the PM2.5 concentration. Conclusions: The hazards concentration levels of aircraft cabin cleaners were very similar to those of roadside outdoor workers. As the main source of pollution is estimated to be diesel vehicles operating at airports, and it is necessary to replace older vehicles, strengthen pollutant emission control regulations, and introduce electric vehicles. In addition, it is necessary to provide as part of airport-inftastructure a stable standby waiting space for aircraft cabin cleaners and introduce a systematic safety and health management system for all workers in the aviation industry.

A Study on Hazard Analysis and Critical Control Points(HACCP) in School Lunch by Analyzing Food Cooking Processes (초등학교급식 식단에 대한 조리공정별 HACCP에 관한 연구)

  • Bin, Sung-Oh;Kim, Moon-Ju
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.8 no.2
    • /
    • pp.79-95
    • /
    • 2007
  • A study was conducted in order to develope HACCP model in school lunch in Korea. Results: 1. Of 22 menus 4(18%) were non heating processes (#1), 2(9%) were food handling by using hands (#2), and 16(73%) were heating processes (#3). Of 279 menus 36(12.9%) belong to process #1, 8(2.9%) to process #2, and 235(84%) to process #3. 2. The critical control points for process #1 were contamination by hands of food handlers, and unsanitary food preparation habits of food handlers. Those for process #2 were improper heating temperature, contaminations by food handlers' hands, and unsanitary food handling habits, and cross contamination by unclean utensils and equipment. 3. Management criteria for the CCPs were conditions of food storage, refrigeration, freezing, food cooking temperature, personal hygiene, washing and sanitization of utensils and equipment. 4. Monitoring criteria for CCPs were observation, temperature checking, inspection of utensils and equipment, and practice of good personal hygiene. 5. Corrective actions were refusal of unsafe products, correction of improper temperature, proper cleaning and sanitization, and proper reheating time and temperature.

  • PDF

Remotely Operated Decontamination Systems for Use in DFDF

  • Kim, Kiho;Park, Jangjin;Myungseung Yang
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.438-446
    • /
    • 2003
  • This paper presents the development of the remotely operated decontamination systems for use in a highly radioactive zone of the DUPIC Fuel Development facility of the Irradiated Material Examination Facility at the Korea Atomic Energy Research Institute. The remotely operated decontamination systems were designed to completely eliminate human interaction with hazardous radioactive contaminants. These decontamination systems are mainly classified into three systems depending on the task environment - a fabrication equipment decontamination system, a hot-cell floor decontamination system, and an isolation room floor decontamination system. A decontamination system for contaminated fabrication equipment utilizes dry ice pellet blasting method to decontaminate contaminated surface of the equipment. The decontamination systems for the hot-cell floor and isolation room floor employ a vacuum cleaning method to decontaminate the contaminated floor and collect loose dry spent nuclear fuel debris and other radioactive waste placed on the floor. The human operator from the out-of-cell performs a series of decontamination tasks remotely by manipulating decontamination systems located in-cell via a handcontroller with the aid of vision feedback information. The environmental, functional and mechanical design considerations, control system and capabilities of the remotely operated decontamination systems at a high radioactive environment are also described.

  • PDF

A Study on the Multizone Modeling for Preventing Transmission of Air Borne Contagion (실내 미생물오염 전파방지를 위한 멀티존 모델링에 관한 연구)

  • Choi, Sang-Gon;Lee, Hyun-Woo;Hong, Jin-Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.11
    • /
    • pp.933-940
    • /
    • 2006
  • In this study multi-zone modeling program CONTAM 2.4 developed by NIST is used for estimating the air disinfection rate of the interior of a room which is set up the indoor air disinfection system with filter and ultra violet germicidal irradiation (UVGI). Developed models those enable to predict the transmission of air home contagion such as bacteria and fungus generated in our daily life are useful model for designning air cleaning & ventilation system of building. Also, results indicate that these models are enable to compute the real situation that is almost impossible of carrying out experiment in an actual condition due to biohazard problems and suggest that engineers will use these models as a design tool for the future immune building system.

Study of the used deuterium absorption material disposal

  • Kim, Dong-Gyung;Kim, Myung-Chul;Lee, Bum-Sig;Lee, Sang-Gu
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.64-72
    • /
    • 2004
  • The dryer (ten per unit) are operating to remove tritium in PHWR(Pressurized Heavy Water Reactor). There are coming out heavy water adsorbent from operating the dryer (95 drums for ten year per unit) The amount of radioactivity of heavy water adsorbent almost exceed ninety times more than disposal limit-in-itself showed by The Ministry of Science and Technology. It has to be disposed whole radioactive waste products, however there are problems of increase at the expense of their permanent disposal. In this research, We have studied how to remove kinds of nuclear materials and amount of tritium with in heavy water adsorbent. As the result we could develop disposal equipment and apply it. D20 adsorbent have to contain below Gamma nuclide O.3Bq/g and tritium 100Bq/g "The Regulation for disposal of the radioactivity wastes" showed by The Ministry of Science and Technology. There fore. So as to remove amount of tritium and kinds of nuclear materials (DTO) we needed a equipment. Also we have studied how to remove effectively radioactivity with in Adsorbent. As cleaning heavy water adsorbent and drying on each condition (temperature for drying and hours for cleaning). Because there is something to return heavy water adsorbent by removing impurities within adsorbent when it is dried o high temperature. After operating, we have been applying this research to the way to dispose heavy water adsorbent. Through this we could reduce solid waste products and the expense of permanent disposal of radioactive waste products and also we could contribute nuclear power plant run safely. According to the result we could keep the best condition of radiation safety super vision and we could help people believe in safety with Radioactivity wastes control for harmony with Environment.

  • PDF

Food Sanitation Management at Foodservice of Correctional Institutions in Korea (교정시설 급식에서의 위생관리 실태조사)

  • Cho, In-Jae;Lee, Hye-Sang
    • Journal of the Korean Dietetic Association
    • /
    • v.17 no.3
    • /
    • pp.302-312
    • /
    • 2011
  • The purpose of this study was to investigate the equipment ratio of sanitary facility/equipment as well as the sanitary management performance level at foodservice of correctional institutions in Korea. For this purpose, a total of 47 questionnaires were distributed to dietitians working at correctional institutions during the period from March 20th to May 18th of 2008. A total of 38 questionnaires (response rate 81%) was analyzed using SPSS (windows ver. 14.0). The majority of the respondents were females (65.8%), 35 years or older (55.3%), with 7 years or longer experiences (65.8%), and with education level of university or higher (60.5%). Among the institutions, 39.5% had less than 500, 28.9% had 501 or more but less than 1,200, and 31.6% had 1,201 or more inmates. The equipment ratio of the sanitary facilities/equipment was 49.7%, which was relatively low. Most dietitians perceived 'limited availability of facilities and equipment' and 'the lack of support from financing department' as the major barriers in implementing a desirable sanitary system. On the other hand, perceived sanitary management performance was rated by the respondents as being between 2.55 to 4.50 (5-point Likert scale)-'Cleaning hands properly as specified' showed the lowest performance, whereas 'Sampling preserved meals by standard methodology' showed the highest. The results of this study suggest that a sanitary education program designed for inmate food handlers is needed for successful sanitary management.

Comparison of PCB Surface Treatment Effect Using UV Equipment and Atmospheric Pressure Plasma Equipment (UV 장비 및 대기압 플라즈마 장비를 이용한 PCB 표면 처리 효과 비교)

  • Ryu, Sun-Joong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.3
    • /
    • pp.53-59
    • /
    • 2009
  • Low pressure mercury lamp type UV equipments have been widely used for cleaning and modification of PCB surfaces. To enhance the productivity of the process, we newly developed remote DBD type atmospheric pressure plasma equipment. The productivity of both equipments could be compared by measuring surface contact angle for various transferring speed. By the result of the measurement, we could verify that the productivity of the atmospheric pressure plasma be superior to the productivity of the UV equipment. XPS experiments confirmed that the surface effect of the UV and atmospheric pressure plasma processing are similar for each other. Organic contamination level was reduced after the processing and some surface elements were oxidized for both cases. Finally, the atmospheric pressure plasma equipment was adapted to flip chip BGA's flux printing process and it was concluded that the printing uniformity be enhanced by the atmospheric pressure plasma surface treatment.

  • PDF