• Title/Summary/Keyword: Cleaning System

Search Result 825, Processing Time 0.022 seconds

Fabric Dyeing with Lichen Parmotrema austrosinence and Improvement of Dyeability by Chitosan Treatment (Parmotrema austrosinence(지의류)를 이용한 직물염색과 키토산 처리에 의한 염색성 향상)

  • Yoo, Hye-Ja;Lee, Hye-Ja;Rhie, Jeon-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.6
    • /
    • pp.882-889
    • /
    • 2008
  • Three fabrics, 100% silk, nylon and cotton each, were dyed with a lichen dye solution prepared by a fermentation method under conditions of varying dyebath pH and temperature. To verify the effect of chitosan on fabric dyeing, the 100% cotton fabric was treated with a chitosan solution before dyeing. The K/S, CIE $L^*$, $a^*$, $b^*$, ${\Delta}E$ and Munsell values of the dyed samples were measured. Colorfastness of each sample was also investigated. The maximum K/S value was measured at 520nm wavelength for the dyed silk fabric and at 480nm for the dyed cotton and nylon. The K/S values for the dyed silk fabric were much greater than those of the other fabrics. The dyed silk fabric showed a red tone on the Munsell color system, and the dyed nylon and cotton fabrics a yellowish red tone. Dye affinity to fabrics was better in a neutral or acidic dyebath. As dyeing temperature increased, K/S values increased for the dyed nylon and cotton fabrics but not for the silk. Dyeability of cotton fabrics could improve by Chitosan treatment. As for most natural dyes, colorfastness of all dyed samples was poor. The silk fabric showed an excellent dry cleaning fastness of Grade 5.

Adhesion Characteristics and the High Pressure Resistance of Biofilm Bacteria in Seawater Reverse Osmosis Desalination Process (역삼투 해수담수화 공정 내 바이오필름 형성 미생물의 부착 및 고압내성 특성)

  • Jung, Ji-Yeon;Lee, Jin-Wook;Kim, Sung-Youn;Kim, In-S.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.51-57
    • /
    • 2009
  • Biofouling in seawater reverse osmosis (SWRO) desalination process causes many problems such as flux decline, biodegradation of membrane, increased cleaning time, and increased energy consumption and operational cost. Therefore biofouling is considered as the most critical problem in system operation. To control biofouling in early stage, detection of the most problematic bacteria causing biofouling is required. In this study, six model bacteria were chosen; Bacillus sp., Flavobacterium sp., Mycobacterium sp., Pseudomonas aeruginosa, Pseudomonas fluorescens, and Rhodobacter sp. based on report in the literature and phylogenetic analysis of seawater intake and fouled RO membrane. The adhesion to RO membrane, the high pressure resistance, and the hydrophobicity of the six model bacteria were examined to find out their fouling potential. Rhodobacter sp. and Mycobacterium sp. were found to attach very well to RO membrane surface compared to others used in this study. The test of hydrophobicity revealed that the bacteria which have high hydrophobicity or similar contact angle with RO membrane ($63^{\circ}$ of contact angle) easily attached to RO membrane surface. P. aeruginosa which is highly hydrophilic ($23.07^{\circ}$ of contact angle) showed the least adhesion characteristic among six model bacteria. After applying a pressure of 800 psi to the sample, Rhodobacter sp. was found to show the highest reduction rate; with 59-73% of the cells removed from the membrane under pressure. P. fluorescens on the other hand analyzed as the most pressure resistant bacteria among six model bacteria. The difference between reduction rates using direct counting and plate counting indicates that the viability of each model bacteria was affected significantly from the high pressure. Most cells subjected to high pressure were unable to form colonies even thought they maintained their structural integrity.

A Study of Heavy Metal-Contaminated Soil Remediation with a EDTA and Boric acid Composite(I): Pb (EDTA와 붕산 혼합용출제를 이용한 중금속으로 오염된 토양의 처리에 관한 연구(I): 납)

  • Lee Jong-Yeol;Kim Yong-Soo;Kwon Young-Ho;Kong Sung-Ho;Park Shin-Young;Lee Chang-Hwan;Sung Hae-Ryun
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.4
    • /
    • pp.1-7
    • /
    • 2004
  • To choose a organic acid and in-organic acid composite which is the most effective in soil-flushing process cleaning lead-contaminated sites, lead removal rates were investigated in the experiments with some organic acids; 0.01M of EDTA showed the highest lead-extraction rate ($69.4\%$) compared to the other organic acids. Furthermore, the lead removal rates were measured with 0.01M of EDIA and 0.1M of in-organic acid ; a EDTA and boric acid composite showed the highest lead-extraction rate ($68.8\%$) at pH5 compared to the other composites. As the concentration of boric acid was increased from 0.1M to 0.4M in a 0.01M of EDTA and boric acid composite, lead removal rate was decreased from $68\%\;to\;45\%$. But as the concentration of EDTA was increased from 0.01M to 0.04M in a EDTA and 0.1M of boric acid composite, permeability was decreased from $6.98{\times}10^{-4}cm/sec$ (0.01M of EDTA) to $5.99{\times}10^{-4}cm/sec$ (0.04M of EDTA). However, permeability was increased from $4.41{\times}10^{-4}cm/sec$ (0.03M of EDTA) to $6.26{\times}10^{-4}cm/sec$ (0.03M of EDTA and 0.1M of boric acid composite). indicating EDTA could increase lead dissolution/extraction rate and decrease permeability. In this system, lead remediation rate is the function of lead dissolution rate from soils and permeability of the composite into soils, and the optimized [EDTA]/[Boric acid] ratio is [0.01M]/[0.1M].

Evaluation of Dental Hygienist Job Validity according to Judgment Standard of Medical Practice in Medical Law (의료행위 기준에 따른 치과위생사 직무 타당도 평가)

  • Bae, Soo-Myoung;Shin, Sun-Jung;Lee, Hyo-Jin;Shin, Bo-Mi
    • Journal of dental hygiene science
    • /
    • v.18 no.6
    • /
    • pp.357-366
    • /
    • 2018
  • The purpose of this study was to evaluate the validity of dental hygienist job according to judgment standard of medical practice in medical law. In this study, we conducted a self-administered questionnaire survey to evaluate the validity of dental hygienist job for 12 professors of dental college in Gangneung-Wonju National University from November 10 to 20, 2017. We investigated whether the dental hygienist job conforms to the three criteria of medical practice such as disease prevention and treatment, patient care, and health hazard. The response rates were scored and classified into four categories according to the final score. As a result of this study, dental hygienist job are classified into four categories according to judgment standard of medical practice. The higher the level of the category, the higher the degree of difficulty, and the higher the level of expertise and skills required. More than 50% of respondents answered that measuring the gingival pocket, bleeding on probing, professional tooth cleaning, oral health education, counseling after dental treatment are all three criteria for medical treatment. And these were classified into Level 4 group which requires the difficulty and expertise in the final score 4.3. It is necessary to develop and utilize standardized guidelines on the level of knowledge, education, and qualification standards required for dental practice in order to effectively allocate work among the dental personnel while ensuring the health rights of patients in the dental clinic field in Korea. In addition, there is a need to evaluate the various aspects of cost effectiveness, dental health service productivity, and health promotion contribution to dental hygienist jobs, And based on this evidence, it is necessary to continue to expand and adjust the dental hygienist job and to reorganize the dental workforce system.

Analysis of Critical Control Points through Field Assessment of Sanitation Management Practices in Foodservice Establishments (현장실사를 통한 급식유헝별 위생관리실태 분석)

  • Kwak Tong-Kyung;Lee Kyung-Mi;Chang Hye-Ja;Kang Yong-Jae;Hong Wan-Soo;Moon Hye-Kyung
    • Korean journal of food and cookery science
    • /
    • v.21 no.3 s.87
    • /
    • pp.290-300
    • /
    • 2005
  • Increased sanitation management of foodservice establishments is required because most of the reported foodborne-disease outbreaks were in the foodservice industry. The purpose of this study was to determine the important control points for good sanitation. In this study, we inspected twenty foodservice establishments in Seoul, Kyunggi, Kyungnam with a self-developed monitoring tool. These foodservice establishments included secondary schools, universities, and industries. Six of them had appointed as the HACCP-certified establishments from the Korea Food and Drug Administration. The inspection was conducted from June to August in 2002. The inspection tool consisted of nine dimensions and sixty-five items. The dimensions were 'personal sanitation', 'supply of raw food', 'food storage', 'handling of raw food and ready-to-eat', 'cleaning and sterilization', 'waste control', 'pest control', and 'control of establishment and equipment' The highest possible score of this inspection tool is 105 points. Statistical data analysis was completed using the SPSS Package(11.0) for descriptive analysis Kruskal-Wallis. The score for the secondary schools (83.6 points) was higher than for the others and number of in compliance item was 50.9 on average. Therefore, we concluded that the secondary schools' sanitation condition was good. The foodservice establishments acquired HACCP certification was 89.7 points, which was significantly higher than that of establishments not applying foodservices in total score. Instituting the HACCP system in a foodservice is very effective for sanitation management. Many out of the compliance observations were found in the dimensions of 'waste control', 'control of establishment and equipment', and 'supply of raw food' 'Clean condition of refrigerator' item was $65\%$ out of the compliance that was the highest percent in this study. 'Notify and observance of heating/reheating temperature' was $45\%$ out of compliance. Items which were over $30\%$ out of compliance were 'sterilization of knifes and chopping boards in cooking', 'education of workers', 'maintain refrigerator temperature blow $5^{\circ}C$', and 'countermeasure of infection workers' In the results, most of the foodservice establishments were poorly managed in temperature control and cross-contamination. The important control points revealed in this study were preventing contamination, cooking temperature compliance, management of raw food and refrigerator. Therefore foodservice establishments should pay attention to education and training about important control points. The systematic sanitation management monitoring tool developed in this study can be effectively applied for conducting self-inspection and improving the sanitary conditions of their own foodservice operations.