• Title/Summary/Keyword: Cleaning System

Search Result 830, Processing Time 0.031 seconds

Improvement of existing drainage system for leakage treatment in exiting underground structures (운영중인 지하구조물의 누수처리를 위한 유도배수공법의 개선)

  • Kim, Dong-Gyou;Yim, Min-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.4
    • /
    • pp.669-683
    • /
    • 2017
  • The objective of this study is to propose a modification of the previously proposed drainage system for catching the partial leakage of underground concrete structures. Two techniques were proposed for applying the drainage system only to the leaking parts. One was for conveying leaking groundwater to the collection point in the drainage system and the other was for conveying the collected groundwater to the primary drainage system of the underground concrete structure. Four waterproofing materials for conveying leaking groundwater to the catchment point of the drainage system, Durkflex made of porous rubber material, KE-45 silicone adhesive with super strong adhesion, Hotty-gel made of polymeric materials and general silicone adhesive were evaluated for waterproofing performance. Hotty-gel only showed perfect waterproof performance and the other three waterproof materials leaked. The modified drainage system with Hotty-gel and drainage pipe with fixed saddle to convey the leaking groundwater from the catchment point to the primary drainage system were tested on the concrete retaining wall. The waterproof performance and the drainage performance were evaluated by injecting 1,000 ml of water in the back of the modified drainage system at the 7-day, 14-day, 21-day, 28-day, 2-month and 3-month. There was no problem in waterproof performance and drainage performance of the modified drainage system during 3 months. In order to evaluate the construction period and construction cost of the modified drainage system, it was compared with the existing leaching repair method in surface cleaning stage, leakage treatment stage, and protective barrier stage. Total construction period and construction cost were compared in considering the contents of work, repair material, construction equipment, working time, and total number of workers. As a result of comparing and analyzing in each construction stage, it was concluded that the modified drainage system could save construction period and construction cost compared to the existing leaching repair method.

Development Status of BTL (Biomass to Liquid) Technology (BTL(Biomass to Liquid) 기술 현황)

  • Chae, Ho-Jeong;Jeong, Kwang-Eun;Kim, Chul-Ung;Jeong, Soon-Yong
    • Journal of Energy Engineering
    • /
    • v.16 no.2
    • /
    • pp.83-92
    • /
    • 2007
  • In view of stringent environment regulations to control the emission of green house gases and also depleting fossil fuel reserves, it is high quality desirable to develop alternative technologies to produce high quality fuels. To this end Biomass to Liquid (BTL) technology has received much attention in recent years. BTL process generally consists of gasification of biomass to produce bio-syngas, cleaning and control of $H_{2}/CO$ mole ratio of bio-syngas and Fischer-Tropsch synthesis & upgrading systems. Choren, Germany has first developed the commercial BTL process using unique gasification system i.e., Carbo-V. A new technology to remove tars and BTX has been developed by ECN in Netherlands employing a gasification system combined with OLGA technology. Several other countries including USA and Japan are showing great interest in BTL technology. Thus in view of our national energy security and also the environmental regulations, it is essential to develop alternative technologies like BTL in order to meet the increasing demand of energy though our insufficient biomass resources. In this paper we present an overview and development status of BTL-diesel technology.

The Analysis of PM10 Concentration and Emission Contribution in the Major Cities of Korea (한반도 주요 대도시의 PM10 농도 특성 및 배출량과의 상관성 분석)

  • Kang, Minsung;Kim, Yoo-Keun;Kim, Taehee;Kang, Yoon-Hee;Jeong, Ju-Hee
    • Journal of Environmental Science International
    • /
    • v.25 no.8
    • /
    • pp.1065-1076
    • /
    • 2016
  • This study analyzes the $PM_{10}$ characteristics (particulate matter with aerodynamic diameter less than $10{\mu}m$), concentration, and emissions in eight large South Korean cities (Seoul, Incheon, Daejeon, Daegu, Gwangju, Ulsan, Busan, Jeju). The annual median of $PM_{10}$ concentration showed a decline of $0.02{\sim}1.97{\mu}g/m^3$ in the regions, except for Incheon, which recorded an annual $0.02{\mu}g/m^3$ increase. The monthly distribution levels were high in spring, winter, fall, and the summer, but were lower in summer for all regions except for Ulsan. These differences are thought to be due to the dust in spring and the cleaning effect of precipitation in summer. The variation in concentrations during the day (diurnal variation) showed that $PM_{10}$ levels were very high during the rush hour and that this was most extreme in the cities (10.00 and 18.00-21.00). The total annual $PM_{10}$ emissions analysis suggested that there had been a general decrease, except for Jeju. On-road mobile (OM) sources, which contributed a large proportion of the particulates in most regions, decreased, but fugitive dust (FD) sources increased in the remaining regions, except for Daegu. The correlation analysis between $PM_{10}$ concentrations and emissions showed that FD could be used as a valid, positive predictor of $PM_{10}$ emissions in Seoul (74.5% (p<0.05)), Dajeon (47.2% (p<0.05)), and Busan (59.1% (p<0.01)). Furthermore, industrial combustion (IC) was also a significant predictor in Incheon (61.7% (p<0.01)), and on-road mobile (OC) sources were a valid predictor in Daegu (24.8% (p<0.05)).

Microbiological Hazard Analysis for HACCP System Application to fermented milk (발효유류의 HACCP 시스템 적용을 위한 미생물학적 위해 분석)

  • Park, Seong-Bin;Kwon, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.438-444
    • /
    • 2015
  • The aim of this research was to apply a HACCP system (Hazard Analysis Critical Control Point) to fermented milk. The main ingredients of fermented milk, work facilities and workers were obtained from a company named YD, which is located in Seobuk-gu, Cheonan-si between November 5 2013 to April 13, 2014. A manufacturing process chart was prepared by referring to the manufacturing process of fermented milk manufacturers in common. The manufacturing process chart was made with raw materials; Raw milk, High Fructose Corn Syrup, Oligosaccharides, Lactic Acid bacteria and Subsidiary ingredients, Warehousing of packaging materials, Storage, Input, Preheating, Mixing, Homogeneity, Sterilization, Precooling, Culture, Filtration, In packaging, Out packaging, Storage, and Consignment, as listed Table 1. The results of the microbiological hazard analysis on the raw materials was safe after sterilization($90^{\circ}C{\pm}5^{\circ}C$, $35{\pm}3min.$) On the other hand,a microorganism test of an environment and workers suggested that the microbiological hazard should be reduced through systematic cleaning and disinfection accompanied by improved personal hygiene based on hygienic education on workers and the management of microorganisms in air.

Analysis of Research for the Actual State and Management of Automated Horticultural Facilities (경북지역 현대화 원예시설의 관리실태 조사분석)

  • 정현교;이기명;박규식
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.174-186
    • /
    • 1996
  • This study was carried out in order to understand the plan, design, constructing and actual condition of management of modernized horticultural facilities in Kyungpook Province which had been constructed from 1992 to 1995 funded by Government support. The aim of this study is to provide reference data for success of the forth project. It was performed by making up a question about driving of project and management condition of equipment after constructing. The results obtained from this study are as follows: 1. 73.5% of facilities horticulture farmhouse recognized that the prospect of greenhouse is bright, but 92.5% of the farmhouse also recognised that they need technical consultation on protected horticulture farming. Therefore, technical educations would must be enhanced about foundation of greenhouse and cultivation technique. 2. The holding times of explanatory meetings, cause of understanding to farmhouse, were one or two times in greenhouse construction, and 62.5% of the farmhouse expressed the insufficiency at the explanation and educational data. For this reason, it was judged that the construction contract had been delayed more than 5 months in 49.3% of the farmhouse after the decision of project budget. 3. In constructing after a contract, the rates of construction delay is 53.4% and defect occurrence is 41.1%. The biggest reasons of construction delay was insufficiency of worker and materials supply. Each percentage is 29.1%. And the reason of defect occurrence is badness of machinery equipment(62.9% ). 4. In management of greenhouse, a pipe-constructed plastic film greenhouse changes plastic film every one and three years because of sticking dust on plastic film. It was needed to about in cleaning technique of coverings. Because that used 3-5 years only half of the expected life span. 5. The order of broken rating in the subsidiary equipment is like this lollop ventilator (42.8%), a general control system(33.3%) especially, in the case of a general control system, the rate of all family can control is 52.7%. so, it is time to develop easy control equipment which every one could use as soon as possible. 6. When choose heat generator as decide capacity, the most priority is the mount of heat generator the percent is 45.5% heat generator and as decide model, the private purchase's percent is 77.3%. It is higher than a public bidding heat generator the percent is 22.7% heat generator when it compare with a public bidding. In the case of $CO_2$ generator, using rate is only 19.0%. The using rate is very low, so it needs education how to use depends on the way of the subsidiary equipment. 7. In the case of seedlings, it is asked to use factory-processed seedling effectively. because it's difficult to get security of labors(58.8%), hoped crops (55.9%) access same crops(29.4%) much more and changing of crops depends on market situation. that is the main reason the lack of knowhow.

  • PDF

Root cause analysis of the abnormal wear on diesel engine crankpin and lubricant contamination (윤활유 오염과 디젤엔진의 크랭크핀 이상마모에 대한 원인 규명)

  • Seo, Jeongwoo;Park, Donghee
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.854-867
    • /
    • 2014
  • In the circumstance that high oil price state is continued over the world, the investment in crude oil development by oil major is a trend of increasing. Recently the number of delivered drill-ship for 5 years has been sharply increased all over the world and about twice than that of past 30 years. As addition to the increase of the drill-ship demand, the operation of drill-ships which is delivered recently is about 3,000 meters, ultra deep sea, on average and the work area is expending. Accordingly the drilling system including the size and length of pipe for drilling has been bigger and bigger and the power supply equipment for operation system also has large capacity. Unlike merchant vessel, high power and high voltage of diesel generators are required for drill-ship for which the demand for V-type 320 bore of diesel generator has increased. It is on the raised that the importance of lubrication oil cleaning for diesel generator on drill-ship which has longer time for construction, and also long term low load operation is unavoidable during commissioning of equipments. Recently it was reported that engine crankpin was damaged due to the hard contact caused by the abnormal wear down(Cam wear) on crankpin and bearing. The same pattern of wear down was found through the inspection on series vessels and the other vessel under commissioning. The purpose of this paper is to analyze of the wear mechanism based on the observation and theories and objective research from actual cases and to prepare the counter measures to avoid foreseeable damage when the lubricating oil is not properly cleaned.

A Study on the Heat Treatment Technology for Reduction of Oxidation Scales (산화피막 저감을 위한 열처리 기술에 관한 연구)

  • Koo, Hee Jun;Chung, Chan Kyo
    • Clean Technology
    • /
    • v.4 no.2
    • /
    • pp.41-53
    • /
    • 1998
  • Most of flame furnace with uncontrolled atmosphere forms oxidation scales in the surface during heat treatment. In this case, shot blasting and pickling are commonly used for reduction of oxidation scales. These processes have many disadvantages, such as long process time, high operating cost and environmental problems due to polishing dust, etc. Hence, this study aimed to develop the advanced heat treating equipment which could make a controlled atmosphere using a heatresisting structure into the flame furnace. The analysis result with SEM, EPMA, and EDX revealed that the amount of scales formed is much less than that with the conventional flame furnace. A brightness of the sample treated with the advanced process is similar compared to the treatment with vacuum furnace. In the present work, it was recommended that the inside structure of the furnace and gas line system could made up of SBB410 and STS310, respectively. The operating cost with the advanced heat treatment system could be reduced annually by forty million won. As a result of this study, it may be possible to reduce the oxidation scales. The fundamental information obtained in this study will be useful not only for improving the heat treatment process(reduction of shot blast and cleaning process), but for promoting the manufacture of bright products.

  • PDF

A study on the flushing characteristics in Geunso bay using hydro-hypsographic analysis (Hydro-hypsographic 분석을 이용한 근소만 해수 교환 특성 연구)

  • Choi, Jong-Kuk;Ryu, Joo-Hyung;Woo, Han-Jun;Eom, Jin-Ah
    • Journal of Wetlands Research
    • /
    • v.13 no.1
    • /
    • pp.45-52
    • /
    • 2011
  • Seawater circulations between a bay and the open sea play an important role to make the ecosystem healthy, providing nutrient and oxygen to the benthic environments and cleaning up pollutions. The health of the benthic environment in a bay is closely related to the flushing characteristics of seawater. In this study, to estimate the seawater distribution and circulation characteristics of benthic environment in the Geunso bay, we calculated the hydraulic turn-over time by a hydro-hypsographic analysis. Digital elevation model (DEM) which was generated using waterline method based upon remotely sensed data and water depth of the subtidal zone estimated by echo-sounding survey was applied to the hydro-hypsograhic analysis through a geographic information system (GIS) spatial analysis. The results showed that 95% of the total area of the bay was tidal flat and the hydraulic turn-over time was 1.03 tidal cycle, which indicated that the flushing characteristics of the Geunso bay was very good. Geunso bay was revealed to occupy relatively wide area of benthic environment and to have relatively big tidal range over other domestic and foreign coastal environment, therefore it could have a better seawater circulation characteristics. This result can be effectively applied as fundamental information to establish the system for a quantitative estimate of health of coastal environment in the west coast of Korea and manage the ecosystem in benthic environments.

An Ultrafiltration Study for the Recycling of Synthetic Water-Based Cutting Oil (수용성 합성 절삭유의 재사용을 위한 한외여과 연구)

  • Kim, Jong-Pyo;Kim, Jae-Jin;Ryu, Jong-Hoon
    • Clean Technology
    • /
    • v.8 no.3
    • /
    • pp.119-128
    • /
    • 2002
  • In the present study the membrane filtration characteristics of a commercially available synthetic water-based cutting oil through two kinds of ultrafiltration membranes (HF1-45-CM50 and HF1-43-CM100) with molecular weight cut-offs of 50,000 and 100,000, respectively, have been investigated in detail. Among these membranes, the hydrophilic one (HF1-45-CM50) was found to show a satisfactory result for both the permeate flux and the permeability of oil components, whereas the permeate flux obtained with the hydrophobic membrane (HF1-43-CM100) appears to be significantly low, indicating that synthetic cutting oil was easily wetted on the hydrophobic membrane surface and induced more membrane fouling. The effect of material characteristics of the membrane on the filtration characteristics was found to be much more significant compared with the mean pore size of the membrane. Backflushing by nitrogen gas was applied to reduce the formation of a gel layer and membrane fouling. With the hydrophilic membrane, the backflushing was found to increase the permeate flux, whereas the backflushing resulted in a decrease in flux for the hydrophobic membrane. The flux recovery was observed to be highest when the membranes fouled with waste synthetic cutting oil were immersed into a cleaning solution for more than 72 hours and then backflushed by nitrogen gas.

  • PDF

Hydrologic and Environmental Assessment of an Infiltration Planter for Roof Runoff Use (지붕 빗물이용을 위하여 개발된 침투화분의 환경·수문학적 평가)

  • Moon, So-Yeon;Choi, Ji-Yeon;Hong, Jung-Sun;Yu, Gi-Gyung;Jeon, Je-Chan;Flores, Precious Eureka D.;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.17 no.4
    • /
    • pp.325-331
    • /
    • 2015
  • Due to urbanization and increase in impervious area, changes in natural water circulation system have become a cause of groundwater recharge reduction, streamflow depletion and other hydrological problems. Therefore, this study developed the infiltration planter techniques applied in an LID facility treating roof stormwater runoff such as, performance of small decentralized retention and infiltration through the reproduction of natural water circulation system and use of landscape for cleaning water. Assessment of an infiltration planter was performed through rainfall monitoring to analyze the water balance and pollutant removal efficiency. Hydrologic assessment of an infiltration planter, showed a delay in time of effluent for roof runoff for about 3 hours and on average, 79% of facilities had a runoff reduction through retention and infiltration. Based on the analysis, pollutant removal efficiency generated in the catchment area showed an average of 97% for the particulate matter, 94% for the organic matter and 86-96% and 92-93% for the nutrients and heavy metals were treated, respectively. Comparative results with other LID facilities were made. For this study, facilities compared the SA/CA to high pollutant removal efficiency for the determination to of the effectiveness of the facility when applied in an urban area.