• Title/Summary/Keyword: Clavicle hook plate

Search Result 19, Processing Time 0.023 seconds

A Novel Fluoroscopic View for Positioning the AO Clavicle Hook Plate Decreases Its Associated in situ Complications

  • Hyun, Yoon-Suk;Kim, Gab-Lae;Choi, Sang-Min;Shin, Woo-Jin;Seo, Dong-Yeon
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.1
    • /
    • pp.25-32
    • /
    • 2016
  • Background: The goal of this study was to evaluate whether a modified fluoroscopic technique for positioning a hook plate affected the clinical results of treating Neer type II distal clavicle fractures and Rockwood type V acromioclavicular (AC) joint separations with this device. Methods: The study was a retrospective consecutive case series with data analysis. Sixty-four patients with a Neer type II distal clavicle fracture or a Rockwood type V AC joint injury treated between March 2009 and June 2013 were divided into 2 groups: traditional fluoroscopic technique (traditional view, 31 patients) or modified fluoroscopic technique ('hook' view, 33 patients). A visual analogue scale (VAS) score, the modified University of California-Los Angeles (UCLA) shoulder scale score, and radiographic osteolysis were the main outcome measures. Results: The traditional group included a significantly larger number of patients with acromial osteolysis than the hook view group: 23 patients (74.2%) vs. 11 patients (33.3%), respectively (p=0.01). Before plate removal, the hook group reported less pain and higher UCLA shoulder scale scores than the traditional group: average VAS score, 1.55 vs. 2.26, respectively; average UCLA score, 30.88 vs. 27.06, respectively. However, there was no significant difference after plate removal. Conclusions: The hook view allows more accurate bending of the hook plate around the contour of the acromion, resulting in decreased osteolysis, decreased pain, and better function with the plate in situ.

Minimal incision Wolter Plate Fixation on the Displaced Lateral End Fracture of the Clavicle and the Acromioclayicular Dislocation (견봉쇄골탈구와 원위쇄골골절에서 소절개를 이용한 Wolter금속판 내고정술)

  • Ko, Sang-Hun
    • Clinics in Shoulder and Elbow
    • /
    • v.5 no.1
    • /
    • pp.23-28
    • /
    • 2002
  • Purpose Displaced lateral end fracture of clavicle and acromioclavicular dislocation type Ⅲ∼Ⅵ may be required surgical treatment. Material and Methods : From May 1998 to March 2001, we operated with Welter plate with minimal incision by one surgeon. Immediately, pendulum and passive exercise was initiated after surgery. The shoulder function was evaluated using UCLA score. Average follow up was on 28(12∼45) months. Results : All 11 patients were regained satisfactory function. Average UCLA score was 31.9(29~35) at last follow up. Conclusion . The merit of Welter plate fixation with minimal incision is simple technique, reduced surgical time, smaller scar than large plate, strong fixation, early exercise, reduced implant failure. The disadvantage is expensive, skin irritatatation by long hook. But Welter plate fixation with minimal incision is a good method of internal fixation and excellent clinical result in surgical treatment of type H displaced lateral end fracture of the clavicle and type Ⅲ∼Ⅵ acromioclavicular dislocation.

Surgical Treatment of Unstable Distal Clavicle Fractures: Comparison of Transacromial Pin Fixation and Hook Plate Fixation (불안정 원위 쇄골 골절의 수술적 치료: 경견봉 강선 고정술과 갈고리형 금속판 고정술의 비교)

  • Kim, Young Sung;Lee, Ho Min;Jang, Han Gil
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The purpose of this study is to compare the clinical and radiological outcomes of two surgical treatments, transacromial pin fixation and hook plate fixation, for unstable distal clavicle fractures. Materials and Methods: Twenty four patients with Neer type II distal clavicle fractures who underwent surgery with transacromial pin fixation (Group I: 12 patients) and hook plate fixation (Group II: 12 patients) were included. Reduction and union were evaluated using plain radiographs. Functional evaluation was performed according to UCLA score and Constant-Murley score at last follow-up. Results: All 24 cases showed bone union. Complete union took an average of 10 weeks for group I and 11.7 weeks for group II. Average UCLA score was 33 (group I) and 32.8 (group II). Average Constant score was 88.5 (group I) and 88.8 (group II). No significant difference for each variable was observed between the two groups. Conclusion: For the surgical treatment of Neer type II distal clavicle fractures, transacromial pin fixation and hook plate fixation are both useful methods.

Spontaneous Healing of Acromial Stress Fracture Caused by Clavicle Hook Plate in Acromioclavicular Joint Dislocation - A Case Report

  • Kim, Gang-Un;Kim, Seong-Hwan;Lee, Jae-Sung;Kim, Jae Yoon
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.1
    • /
    • pp.36-39
    • /
    • 2014
  • Clavicular hook plate is known to be an effective treatment on acromioclavicular (AC) joint injury, but there have been some reports of complications, like osteolysis and bony erosion of the undersurface of acromion. Fifty-five year old male underwent open reduction and hook plate insertion on Rockwood type 5 acromioclavicular joint dislocation. He complained of protrusion of posterior acromion at 1 month after the surgery, and acromial fracture was noted in simple radiographs. The hook plate was removed and any other treatment for osteosynthesis was refused by the patient. At the 18 months after the surgery, the patient had no pain and a full range of motion with no tenderness around the shoulder joint. After two years, plain radiographs revealed complete bony union of the acromion fracture.

Hook Plate Fixation for Unstable Distal Clavicle Fractures: A Prospective Study (불안정 원위 쇄골 골절의 치료에서 Hook 금속판을 이용한 전향적 연구)

  • Kim, Kyung-Cheon;Shin, Hyun-Dae;Cha, Soo-Min;Jeon, Yoo-Sun
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.6-12
    • /
    • 2011
  • Purpose: We wanted to analyze and report on the radiologic and clinical results of prospective Hook plate fixation for unstable distal clavicle fractures after a minimum of 2 years follow up. Materials and Methods: We followed up 17 out of 20 cases that underwent prospective Hook plate fixation from 2008 to 2009. We performed radiologic follow up at 2 weeks, 6 weeks, 3 months, 6 months, 18 months and 24 months postoperatively. The clinical results were evaluated at 12 months and 24 months postoperatively. Results: The mean period for bony fusion was 14.5 weeks and the plate was removed after an average of 20.2 weeks. The VAS pain scores were 0.7 and 0.8, the UCLA scores were 33.5 and 33.3, the ASES scores were 92.8 and 92.5, the Constant-Murley scores were 81.5 and 77.0, the KSS scores were 92.5 and 94.3 and the ranges of motion were $173.3^{\circ}$ and $173.7^{\circ}$ of flexion, $56.0^{\circ}$ and $54.5^{\circ}$ of external rotation, $62.3^{\circ}$ and $63.5^{\circ}$ of the internal rotation, $172.0^{\circ}$ and $172.6^{\circ}$ of abduction and $43.3^{\circ}$, and $42.9^{\circ}$ of extension at 1 and 2 years follow-up, respectively. There was no statistically significant difference of clinical outcomes and the range of motion at 1 year and 2 year postoperatively (p>0.05). There was no other complication except 1 case of delayed union. Conclusion: For Hook plate fixation at 2 years postoperatively, the complications will be decreased and excellent clinical results should occur.

Treatment of the Acromioclavicular Joint Dislocation Using a AO Hook Plate (AO Hook 금속판을 이용한 견봉쇄골 관절 탈구의 치료)

  • Lee, Ki-Won;Choi, Young-Joon;Ahn, Hyung-Sun;Kim, Chung-Hwan;Hwang, Jae-Kwang;Han, Hee-Don;Kim, Jae-Hyoun;Joo, Youn-Suk
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.167-172
    • /
    • 2009
  • Purpose: We wanted to evaluate the results of treating acromioclavicular joint dislocation using an AO hook plate. Materials and Methods: Between February 2008 and September 2009, 10 patients underwent implant removal after surgical treatment of acromioclavicular joint dislocation using a AO hook plate. The Constant-Murley scoring system was administered postoperatively for evaluating the clinical results, and simple X-ray was taken for evaluating the state of reduction. Results: All cases showed satisfactory results on the clinical and radiological study. The mean Constant-Murley score at follow-up was 90.5 (range: 84~95). Three patients had some degree of discomfort with the hook plate, but these symptoms were relieved on removal of the plate. The radiological evaluation showed restoration of the vertical displacement of the clavicle in all the patients. No complications occurred such as infection, plate failure or redislocation after removal of the plate. Conclusion: The short term follow-up results of treating acromioclvicular joint dislocation using an AO hook plate were satisfactory both clinically and radiologically.

In Vivo Three-dimensional Evaluation of the Functional Length of Glenohumeral Ligaments

  • Goto, Akira;Sahara, Wataru;Koishi, Hayato;Yoshikawa, Hideki;Sugamoto, Kazuomi
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2009.03a
    • /
    • pp.174-174
    • /
    • 2009
  • The acromioclavicular-hook-plate is one of the surgical treatments for distal clavicle fracture and traumatic acromioclavicular (AC) joint dislocation. Although this procedure can obtain rigid and accurate anatomical reduction of the AC joint, secondary widening of the hook-hole in the acromion is often seen during postoperative follow-up. This complication is owing to the high-degree of mobility of the AC joint. Therefore, it is important to evaluate the effect on these complications due to the position of the hook-hole. The purpose of the present study is to investigate three-dimensionally the effect due to the position of the hook-hole during arm abduction motion. We studied in vivo and three-dimensional kinematics of the normal shoulder joint with use of a markerless bone-registration technique. Magnetic resonance images of 14 shoulders of 7 healthy volunteers were acquired in 7 positions between $0^{\circ}$ and $180^{\circ}$ of abduction. We created three-dimensional computer models of the bones and the acromioclavicular-hook-plate. Based on the three-dimensional kinematics data, we simulated the widening of the hook-hole each different positioning of the hook-hole. The widths of the hook-holes almost linearly increased. And these widths significantly increased, when we put the hook-hole on the acromion from AC joint to 20 mm and 25 mm posterior position.

  • PDF

Treatment of Type 2 Distal Clavicle Fracture using Wolter Plate (Wolter 금속판를 이용한 제 2형 원위부 쇄골 골절의 치료)

  • Shin, Sung-Il;Song, Kyung-Won;Lee, Jin-Young;Lee, Seung-Yong;Kim, Gab-Rae;Hyun, Yoon-Suk;Lee, Kwang-Nam;Lee, Eun-Soo
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.14-20
    • /
    • 2009
  • Purpose: This study examined the clinical results of the treatment of type 2 distal clavicle fracture with using a Wolter plate. Materials and Methods: Between 2004 and 2007, 16 patient treated for type 2 distal clavicle fracture using a Wolter plate were included in this study. Their average age was 32.6 years and the postoperative mean follow-up period was 22.9 months. The reduction and union were qualified according to the immediate post-operative and final radiographs. The functional outcome was evaluated by Kona's system and the Constant score Results: By Kona's functional evaluation, there were 12 cases with excellent results, 3 cases with good results and 1 case of fair results and the average Constant score was 90. All 16 cases showed bony union. As complications, there was 1 case in which the protruded hook of the plate could be palpated at the skin, and 1 case showed an acromial fracture, but all the cases dispalyed successful bony union and there was no acromioclavicular joint arthritis, infection or any other complications. Conclusion: Wolter plate fixation for type 2 distal clavicle fracture is a reliable surgical method for satisfactory reduction and rigid fixation, a lower incidence of nonunion and excellent clinical result.