• Title/Summary/Keyword: Civil Society

Search Result 18,071, Processing Time 0.047 seconds

Washoff Characteristics of Metal Pollutants in Highways (고속도로 노면유출수의 중금속 유출 특성 및 상관성)

  • Lee, Eun-Je;Ko, Seok-Oh;Kang, Hee-Man;Lee, Joo-Kwang;Lim, Kyeong-Ho;Lee, Byung-Sik;Kim, Lee-Hyung
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.128-133
    • /
    • 2006
  • The paved areas in nonpoint source are highly polluted landuses because of high imperviousness and high pollutant mass emissions from vehicle activities. Particularly, the metal pollutants are a big issue in the paved area. It is usually washed-off during storms by adsorbing on sediments or soluble status. Therefore, this research was achieved for understanding the characteristics of metal pollutants in stormwater runoff in highways. Five monitoring sites were equipped with an automatic rainfall gage and an automatic flow meter. This manuscripts will summarize the washoff characteristics of metal pollutants and its concentration changes during storms. Usually first flush phenomenon was observed for all of the storm events and visibly confirmed with hydro- and polluto-graphs. Also it was coincided with the tendency of particulates and organic matters. The decrease rate per total reduced amount for metals during initial 30-min storm duration was obtained on 80%. The result may be able to use for determining the economical treatment criteria for stormwater runoff in highways.

Determination of EMCs and Comparison with Sampled Concentrations in Paved Areas (포장지역에서의 강우사상별 EMC 산정 및 단순 샘플농도와의 비교)

  • Lee, Eun-Ju;Ko, Seok-Oh;Kang, Hee-Man;Lee, Joo-Kwang;Lee, Byung-Sik;Lim, Kyeong-Ho;Kim, Lee-Hyung
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.104-109
    • /
    • 2006
  • TPLMS programs in four large rivers have been developed to improve the water quality from possible pollutants originated from watershed areas. The success of TPLMS program is depended on nonpoint source control. Currently, the pollutant loading from nonpoint pollution sources is gradually increasing as developing the nearby watershed. However, there are not enough data concerning on nonpoint pollution in Korea because of lacking of monitoring activities. It is the main reason of uncertainty. Therefore, this manuscript will summarize the EMCs in various landuses based on monitoring program. Also the EMC in each paved area will be compared and discussed to find the differences. When the EMC is compared by average monitored sample concentrations, the EMC values are 2-4 times higher than sample concentrations. It means the monitoring program is very important in the field of nonpoint pollution. The pollutant loadings from bridge landuse is higher than loadings from parking lot and highway because of more traffic activities.

Study on Autotrophic Denitrification by the Injection of Spent Sulfidic Caustic in a Hybrid Bardenpho Process (Hybrid Bardenpho 공정에서 Spent Sulfidic Caustic의 주입을 통한 독립영양 탈질에 관한 연구)

  • Lee, Jae-Ho;Park, So-Ra;Park, Jeung-Jin;Byun, Im-Gyu;Park, Tae-Joo
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.5
    • /
    • pp.563-568
    • /
    • 2008
  • In petroleum refining industry, caustic (NaOH) solution is used to remove $H_2S$ from hydrocarbon streams in naphtha cracking process. Once $H_2S$ is absorbed in caustic solution, the solution becomes known as spent sulfidic caustic (SSC), which contains high concentrations of hydrogen sulfide and alkalinity. This study was focused on the evaluation of autotrophic denitrification by SSC in a hybrid Bardenpho process. SSC was injected to the anoxic (1) and anoxic (2) tank at different S/N ratio. In a previous lab-scale study, as we operated a modified Ludzack-Ettinger process, it was observed that the COD increment of effluent and nitrification failure happened because of non-biodegradable matters in SSC and high pH, respectively. Thus cilia media was packed at 2.4%(v/v) in all aerobic tanks and the pH of SSC was neutralized from 13.3 to 11.5 with addition of sulphuric acid ($H_2SO_4$). Consequently, these strategies were successful because no COD increment of effluent was observed and nitrification failure did not happen. The maximum TN removal efficiency was 77.5% when SSC was injected to both the anoxic (1) and anoxic (2) tanks. The mean TN concentration of effluent in this condition was 5.8 mg/L.

Evaluation of Operation Parameters for the Removal of Algae by Electro-Coagulation (수계 내 조류 제거를 위한 전기응집 운전 특성 평가)

  • Jeong, Kwon;Kim, Do-Gun;Kim, Seog-Ku;Kim, Weon-Jae;Ko, Seok-Oh
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.2
    • /
    • pp.94-102
    • /
    • 2015
  • Electro-coagulation experiments were conducted with aluminum (Al) or iron (Fe) electrode in order to determine the optimal electrode material and operation conditions for algae removal. Al electrode showed higher removal rate of algae than Fe electrode because Al flocs have positive surface charges which electrostatically attract algae species having negative surface charges. Removal rate of algae and total phosphorous (T-P) was increased as current density and electrode area increases. It was also found that initial pH with neutral range was optimum for T-P removal by electro-coagulation. Bench-scale continuous flow experiments consisted of electro-coagulation reactor, agitation tank and settling tank were conducted. In electro-coagulation reactor, a large fraction of Al flocs were distributed to scum layer, due to the gas bubbles generated by electrolysis reaction. In agitation tank, most of Al flocs were settled and the optimal mixing intensity was found to be 50 rpm to achieve good settleability. The removal rate of algae was about 90-95%. Additionally, the removal rate of the T-P and COD was observed to be $73.8{\pm}8.0%$ and $75.0{\pm}3.8%$, respectively. Meanwhile, the removal rate of total nitrogen (T-N) was relatively low at only 24%.

Verification of the Filter Media Applied to Filter Type Facility Considering the Treatment Efficiency Factor (여과형 시설에 적용되는 여재의 처리효율 영향인자를 고려한 실증화 평가)

  • Kim, Taeyoon;Lee, Junebae;Lee, Dongwoo;Shin, Hyunsuk;Kim, Hyunchul;Kwon, Soonchul
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.5
    • /
    • pp.572-579
    • /
    • 2017
  • Increased impervious surface caused by rapid urbanization serves to produce the discharge of non-point source pollutants such as total suspended solid (TSS). There exist various methods of removing TSS, including a filtration process using granular media (a well-known method to be practically used after the consideration of removal efficiency, clogging, and backwashing efficiency). To determine the TSS removal capability of the filter, we initially performed lab-scale experiments which assessed flow rates, influent concentrations, permeability co-efficients, the particular shapes of suspended solids and potential clogging, and also evaluated TSS removal efficiency when applied to filtration facility in a pilot-scale. In low filtration flux condition, the removal efficiency of suspended solids was more than 95 %, while decreased to 83% in high filtration flux. Regarding the clogging aspect of the experiment, total cumulative solids were loaded up to $19.15kg/m^2$, and TSS removal efficiency was noted to commence to decrease when the loaded solids exceeded $9.0kg/m^2$. It was also noted, however, that superior efficiency was maintained for six hours. In addition, for pilot-scale experiment, the removal efficiency was still high enough (83.4 %) for the solid concentration of 140 ~ 343 mg SS/L and after backwashing, head loss was recovered to 92 ~ 95 % during two hour filtration. With these results, It was confirmed that lifetime of the filter applied to the test was prolonged due to the high treatment efficiency and good backwashing efficiency for the cumulative solids load.

Analysis of Fouling Propensity due to Scale Formation in the Treatment of Shale Gas Produced Water Using Direct Contact Membrane Distillation (DCMD) (직접 접촉식막증발을 이용한 셰일가스 발생수의 처리에서 스케일 형성에 의한 막오염 경향 분석)

  • Shin, Yonghyun;Ko, Younghoon;Choi, Yongjun;Lee, Sangho;Sohn, Jinsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.511-519
    • /
    • 2016
  • Shale gas has become increasingly important as a viable alternative to conventional gas resources. However, one of the critical issues in the development of shale gas is the generation of produced water, which contains high concentration of ionic compounds (> TDS of 100,000 mg/L). Accordingly, membrane distillation (MD) was considered to treat such produced water. Experiments were carried out using a laboratory-scale direct contact MD (DCMD). Synthetic produced water was prepared to examine its fouling propensity in MD process. Antiscalants and in-line filtration were applied to control fouling by scale formation. Fouling rates (-dJ/dt) were calculated for in-depth analysis of fouling behaviors. Results showed that severe fouling occurred during the treatment of high range produced water (TDS of 308 g/L). Application of antiscalant was not effective to retard scale formation. On the other hand, in-line filtration increased the induction time and reduced fouling.

Scale formation on vacuum membrane distillation for SWRO brine treatment (진공 막증류 공정의 스케일 막오염 형성에 관한 연구)

  • Hwang, Tae-Mun;Jang, Eun-Kyung;Nam, Sook-Hyun;Koo, Jae-Wuk;Kim, Eun-Ju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.4
    • /
    • pp.311-319
    • /
    • 2017
  • Scale formation is inevitable problem when seawater is treated by vacuum membrane distillation. The reason is the high concentration of calcium ion($Ca^{2+}$), sulfate ion(${SO_4}^{2-}$) and bicarbonate ion(${HCO_3}^-$). These ions form calcium sulfate($CaSO_4$) and calcium carbonate($CaCO_3$) on the membrane. The scale formed on membrane has to be removed, because the flux can be severely reduced and membrane wetting can be incurred. This study was carried out to investigate scale formation and effectiveness of acid cleaning in vacuum membrane distillation for SWRO brine treatment. It was found that permeate flux gradually declined until volume concentration factor(VCF) reached around 1.55 and membrane wetting started over VCF over 1.6 in the formation of precipitates containing $CaSO_4$ during VMD operation. In contrast, when calcium carbonate formed on membrane, permeate flux was gradually reduced until VCF 3.0. The precipitates containing both $CaSO_4$ and $CaCO_3$ were formed on the membrane surface and in the membrane pore.

The Compensation Cost Analysis of Parcels for Land Alternation according to Occupation Ratio to Road (도로 편입률에 따른 토지이동 대상필지 보상비 분석)

  • Lee, Geun Sang;Park, Jong Ahn;Cho, Mi Su;Cho, Gi Sung
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.1
    • /
    • pp.13-22
    • /
    • 2014
  • Recently, many civil appeals have been occurred in land management work because of discord between cadastral records and actual land use pattern. it is important to select parcels for land alternation exactly using land information and to evaluate compensation cost according to scenarios for advancing this problem. This study operated GIS spatial overlay based on serial cadastral maps and actual-width of the road and analyzed the number and area of the parcels for land alternation by the land classification and ownership applying fuzzy membership function according to occupation ratio to road. Also compensation cost was calculated according to scenarios using individual public land price information of the parcels for land alternation and was arranged by district as Eup and Myeon according to land classification and ownership. This study can efficiently support the work of the parcels for land alternation complying with the financial condition of local government, by supplying compensation cost according to scenarios to the parcels of land alternation by district as Eup and Myeon.

Evaluation of Geometric Error Sources for Terrestrial Laser Scanner

  • Lee, Ji Sang;Hong, Seung Hwan;Park, Il Suk;Cho, Hyoung Sig;Sohn, Hong Gyoo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.2
    • /
    • pp.79-87
    • /
    • 2016
  • As 3D geospatial information is demanded, terrestrial laser scanners which can obtain 3D model of objects have been applied in various fields such as Building Information Modeling (BIM), structural analysis, and disaster management. To acquire precise data, performance evaluation of a terrestrial laser scanner must be conducted. While existing 3D surveying equipment like a total station has a standard method for performance evaluation, a terrestrial laser scanner evaluation technique for users is not established. This paper categorizes and analyzes error sources which generally occur in terrestrial laser scanning. In addition to the prior researches about categorizing error sources of terrestrial Laser scanning, this paper evaluates the error sources by the actual field tests for the smooth in-situ applications.The error factors in terrestrial laser scanning are categorized into interior error caused by mechanical errors in a terrestrial laser scanner and exterior errors affected by scanning geometry and target property. Each error sources were evaluated by simulation and actual experiments. The 3D coordinates of observed target can be distortedby the biases in distance and rotation measurement in scanning system. In particular, the exterior factors caused significant geometric errors in observed point cloud. The noise points can be generated by steep incidence angle, mixed-pixel and crosstalk. In using terrestrial laser scanner, elaborate scanning plan and proper post processing are required to obtain valid and accurate 3D spatial information.

Structural Analysis of Multipurpose Fishway in Chuksan River (척산천의 다기능 어도의 구조 해석)

  • Lee, Young Jae;Lee, Jung Shin;Kim, Mun Gi;Park, Sung Sik;Jang, Hyeong Kyu
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.1
    • /
    • pp.97-107
    • /
    • 2017
  • In this study, the validity and applicability of the multipurpose fishway which has been constructed for the upstream migration of fish at Chuksan river in Uljin is assessed and analyzed by a commercial software. The upper slab types of fishway in this investigation are reinforced concrete slab (S1 type) and reinforced concrete slab with steel plate (S2 type). The three different sizes of subway passage ($0.8m{\times}0.1m$, $0.8m{\times}0.2m$, $0.8 m{\times}0.3m$) and velocities (0.6 m/s, 1.2 m/s, 1.8 m/s) of Chuksan fishway was investigated and compared for the Chuksan in government design code. The analysis showed that the maximum stress and bending moment of S1 type decreased 1~21 % and 12~27 % compared to the Chuksan in government design code, respectively. Also, the maximum stress of and bending moment of S2 type decreased 11~32 % and 27~39 %. From the numerical analysis, it was found that the S2 type was greatly effective and the subway passage size of $0.8m{\times}0.2m$ was most safe. This result can be utilized to be the basic data for design of the Multipurpose fishway.