• Title/Summary/Keyword: Civil Engineering

Search Result 32,353, Processing Time 0.055 seconds

Analysis of GIUH Model by Using GIS in River Basin (하천유역에서 GIS를 이용한 GIUH 모형의 해석)

  • Heo, Chang-Hwan;Lee, Sun-Tak
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.3
    • /
    • pp.321-330
    • /
    • 2002
  • This study aims at the analysis of the geomorphological instantaneous unit hydrograph model (GIS-GIUH) with geographic information system for the rainfall-runoff analysis of watershed which is ungaged or doesn't have sufficient hydrologic data. The rainfall-runoff analysis was performed in Wi stream(Dongkok, Koro, Miseung, Byeungchun, Hyoreung, Museung) which is a representative experimental river basin of IHP. In the process of analysis of the GIUH model, developed GIS-GIUH model and Rosso-GIUH model were applied the study basin and computed hydrographs by these models were compared with observed hydrograph. The GiS-GIUH model shows more closely to the observed hydrograph than Rosso-GIUH model in the peak discharge of the hydrograph. For the development of the GIS-GIUH model, Gamma function factor N was given by N=3.25( $R_{B}$/ $R_{A}$)$^{0.126}$ $R_{L}$$^{-0.055}$, which is the relation of the watershed geomorphological factor, K was also obtained as K=1.50( $R_{A}$/( $R_{B}$. $R_{L}$))/$^{0.10}$.(( $L_{{\Omega}}$+ $L_{{\Omega}-1}$)/V)$^{0.37}$. As the results of analysis, it was found that GIS-GIUH model can be applied to an ungaged watersheds.eds.

Study on Characteristice of Transient Soulte Transport in the Vadose Zone by Using TDR: (1) Relationship between Water Content and Realtive Electrical Conductivity (TDR(Time Domain Reflectometry)를 이용한 비포화 토양에서 천이상태의 오염원 이송확산 특성에 관한 연구 : (1) 함수량과 상대전기전도도의 관계)

  • Park, Jae-Hyeon;Seo, Il-Won
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.6
    • /
    • pp.741-749
    • /
    • 1999
  • This study is to develop a method of measuring the soil water concentration by using TDR, which is based on the relationships between the bulk soil electrical conductivity of soil and the reflected wave of TDR. The proposed monitoring method is combined with two important relationships. One is that between the bulk soil electrical conductivity and the solute concentration, which is known to be linear at a constant volumetric soil water content and the other is that between the relative bulk soil electrical conductivity and the water content at a constant concentration. Some formulas have been proposed to solve the second relationship, but a new formula and the critical water content are proposed to improve the accuracy of measurement. This proposed formula estimates the relative bulk soil electrical conductivity for water contents which is divided to two regions, linear and nonlinear, by the critical water content. As the result of the comparison with other formulas, the proposed formula is proved to be superior to other formulas and to be an available method to apply to the unsaturated transient solute transport.

  • PDF

A Review of Research Trend Related to NPS and Suggestion for Research Direction in the Future (국내 비점오염 관련 연구 동향 및 향후 연구방향 제언)

  • Jeon, Jechan;Jung, Jeho;Kim, Yongseok;Kim, Lee-hyung
    • Journal of Wetlands Research
    • /
    • v.20 no.1
    • /
    • pp.80-93
    • /
    • 2018
  • Research trend about nonpoint pollution source(NPS) that have studied since 1980 was divided into 4 categories: 1) runoff characteristics of NPS, 2) treatment technique, 3) LID and green infrastructure(GI), 4) management practices and policy. This study reviews them and recommends the future research direction. The research on runoff characteristics of NPS until 2010 was mainly carried out. But recently, many researchers has been conducting studies on technology development, effect evaluation and field application. Providing best measures on NPS should be tried to conduct studies that many fields such as society, geography, meteorology and environment are fused. But it has not been enough yet. Because the cause material and optimum measures of NPS are different from each other regionally, it is considered that it needs studies to prepare measures and guidelines with regional characteristics rather than a uniform measures and guidelines by the central government. In addition, more comprehensive studies must be carried out to establish rules and regulations to manage NPS not only by government sector but also the private sector.

The Study on the Development of Flood Prediction and Warning System at Ungaged Coastal Urban Area - On-Cheon Stream in Busan - (미계측 해안 도시 유역의 홍수예경보 시스템 구축 방법 검토 - 부산시 온천천 유역 대상 -)

  • Shin, Hyun-Suk;Park, Yong-Woon;Hong, Il-Pyo
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.6 s.179
    • /
    • pp.447-458
    • /
    • 2007
  • In this study, the coastal urban flood prediction and warning system based on HEC-RAS and SWMM were investigated to evaluate a watershed of On-Cheon stream in Busan which has characteristics of costal area cased by flooding of coastal urban areas. The basis of this study is a selection of various geological data from the numerical map that is a watershed of On-Cheon stream and computation of hydrologic GIS data. Thiessen method was used for analyzing of rainfall on the On-Cheon stream and 6th regression equation, which is Huff's Type II was time-distribution of rainfall. To evaluate the deployment of flood prediction and warning system, risk depth was used on the 3 selected areas. To find the threshold runoff for hydraulic analysis of stream, HEC-RAS was used and flood depth and threshold runoff was considered with the effect of tidal water level. To estimate urban flash flood trigger rainfall, PCSWMM 2002 was introduced for hydrologic analysis. Consequently, not only were the criteria of coastal urban flood prediction and warning system decided on the watershed of On-Cheon stream, but also the deployment flow charts of flood prediction and warning system and operation system was evaluated. This study indicates the criteria of flood prediction and warning system on the coastal areas and modeling methods with application of ArcView GIS, HEC-RAS and SWMM on the basin. For the future, flood prediction and warning system should be considered and developed to various basin cases to reduce natural flood disasters in coastal urban area.

Study on the Environmental Quality Assessment of River Revetment Technique by Life-Cycle-Assessment (전과정 평가에 의한 하천 호안 공법의 환경성 평가에 관한 연구)

  • Kim, Kook-Il;Ahn, Won-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.6 s.179
    • /
    • pp.485-494
    • /
    • 2007
  • This study was performed to evaluate the environmental qualities of the revetment construction methods and the river-facility materials using Life-Cycle-Assessment(LCA) for the nature-friendly design of close-to-nature river, The investigation results on the environmental qualities of energy and materials used to the close-to-nature river plan showed that the environmental impacts per unit weight increased in the order of gasoline > diesel > cement > wood. The environmental impacts per unit area of revetment construction method exhibited that the environmental loadings increased in the order of gabion > revetment > cribwork. In addition, it was observed that the environmental impact was reduced by improving the materials of zinc-galvanized wire. The model basin investigated in this study was the $0.3km^2$ area of river improvement works in Kyung stream, which is a tributary to the Seomjin river and the second regional stream. The research was conducted based on the 30years by life expectancy of artificial facilities. For the comparisons of revetment techniques with respect to the environmental qualities, the method resulted in the highest environmental loadings. The method using ready-mixed concrete ranked second in the environmental loadings of revetment techniques. The present results of this study are expected to play a beneficial role in the nature-friendly design of close-to-nature river by quantitatively identifying the environmental quality of total procedures (i.e., combination of techniques, selection of river-facility materials, maintenance of river-facility) applied to close-to-nature river plan.

Serviceability Assessment of a K-AGT Test Bed Bridge Using FBG Sensors (광섬유 센서를 이용한 경량전철 교량의 사용성 평가)

  • Kang, Dong-Hoon;Chung, Won-Seok;Kim, Hyun-Min;Yeo, In-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.4
    • /
    • pp.305-312
    • /
    • 2007
  • Among many types of light rail transits (LRT), the rubber-tired automated guide-way transit (AGT) is prevalent in many countries due to its advantages such as good acceleration/deceleration performance, high climb capacity, and reduction of noise and vibration. However, AGT is generally powered by high-voltage electric power feeding system and it may cause electromagnetic interference (EMI) to measurement sensors. The fiber optic sensor system is free from EMI and has been successfully applied in many applications of civil engineering. Especially, fiber Bragg grating (FBG) sensors are the most widely used because of their excellent multiplexing capabilities. This paper investigates a prestressed concrete girder bridge in the Korean AGT test track using FBG based sensors to monitor the dynamic response at various vehicle speeds. The serviceability requirements provided in the specification are also compared against the measured results. The results show that the measured data from FBG based sensors are free from EMI though electric sensors are not, especially in the case of electric strain gauge. It is expected that the FBG sensing system can be effectively applied to the LRT railway bridges that suffered from EMI.

Nitrogen Budget Analysis Using a Box Model for Hajeon Tidal Flat in the West Coast of Korea (Box model을 이용한 서해 곰소만 하전 갯벌의 질소 수지)

  • Yoo, Jae-Won;Hong, Jae-Sang;Yang, Sung-Ryull;Park, Kyeong
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.7 no.4
    • /
    • pp.257-266
    • /
    • 2002
  • To estimate the nitrogen budget and assess the purification function of a tidal flat ecosystem, a field survey was carried out at Hajeon tidal flat in Gomso Bay, the southern part of Byeonsan Peninsula, Chollabuk-do, Korea. A study area of 3.0$\times$4.5 ㎢ was established on the tidal flat and the concentrations of chlorophyll-a, DIN, DON, and TN were measured in the water column during the period of April 17-18, 1999: From the budget analysis, the loss rate of Chl-a was estimated to be -0.05 mg Chl/㎡/hr, which is approximately 7% of that at Issiki tidal flat in Aichi Prefecture, Japan. The lower loss rate of Chl-a in the study area was attributable to the lower standing crop of phytoplankton, the lower temperature that may reduce metabolic rates of biotic components and the lower biomass of macrobenthos in the study area. Over the 13.5 ㎢ of study area, Hajeon tidal flat removed 8.36$\times$10$\^$2/ kg N/day of TN, 5.36$\times$10$\^$3/ kg N/day of PON and 1.62$\times$10$\^$2/ kg N/day of phytoplankton-related PON, showing that the tidal flats may play an important role in removing nitrogen in coastal waters. The removal rate of PON, compared to the removal cost of the existing waste water treatment facilities, indicates that the economic value of the purification function of Hajeon tidal flat (13.5㎢) may be more than that of two large facilities.

Effects of Light-Blocking on Water Quality and Phytoplankton Community in Lake Juam (주암호에서 수질과 식물플랑크톤 군집에 미치는 광 차단효과)

  • Lee, Yong-Woon;Lee, Hak-Young
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.2 s.103
    • /
    • pp.150-160
    • /
    • 2003
  • This study was carried out to assess inhibitory effects of light-blocking on water quality and phytoplankton community in Lake Juam from August to November 2000. The values of water temperature, DO, TN, $NO_3-N$, $NH_4-N$, TP, DIP, COD, SS and PH did not show clear differences between inside and outside light-blocked areas. Concentrations of Chl-a decreased -6.6${\sim}$40% (mean 14.7%) from inside of the light-blocked area by light blocking. During the study, 55 species of phytoplankton were indentified, and the dominant species were Microcystis aeruginosa, Aulacoseira granulata, Peridinium sp., Synedra spp., Oscillatoria sp., Fragilaria construens, and Trachelomonas sp. The successional pattern of dominant phytoplankton was diatoms (July)${\to}$ diatoms/cyanophytes (August-September)${\to}$cyanophytes (October)${\to}$ diatoms (October-November). The standing crop of phytoplankton showed maximum density in 22 September with $1.1{\times}10^4$cells/L, and minimum in 25 October with $4.7{\times}10^3$ cells/L. The decreasing efficiency of standing crop by light-blocking was 8${\sim}$38% (mean 19.9%). Through this study we found that blocking light seems to have a decreasing effect on the density of phytoplankton.

Unsupervised Change Detection for Very High-spatial Resolution Satellite Imagery by Using Object-based IR-MAD Algorithm (객체 기반의 IR-MAD 기법을 활용한 고해상도 위성영상의 무감독 변화탐지)

  • Jaewan, Choi
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.33 no.4
    • /
    • pp.297-304
    • /
    • 2015
  • The change detection algorithms, based on remotely sensed satellite imagery, can be applied to various applications, such as the hazard/disaster analysis and the land monitoring. However, unchanged areas sometimes detected as the changed areas due to various errors in relief displacements and noise pixels, included in the original multi-temporal dataset at the application of unsupervised change detection algorithm. In this research, the object-based changed detection for the high-spatial resolution satellite images is applied by using the IR-MAD (Iteratively Reweighted- Multivariate Alteration Detection), which is one of those representative change detection algorithms. In additionally, we tried to increase the accuracy of change detection results with using the additional information, based on the cross-sharpening method. In the experiment, we used the KOMPSAT-2 satellite sensor, and resulted in the object-based IR-MAD algorithm, representing higher changed detection accuracy than that by the pixel-based IR-MAD. Also, the object-based IR-MAD, focused on cross-sharpened images, increased in accuracy of changed detection, compared to the original object-based IR-MAD. Through these experiments, we could conclude that the land monitoring and the change detection with the high-spatial-resolution satellite imagery can be accomplished efficiency by using the object-based IR-MAD algorithm.

Comparative Analysis of Focal Length Bias for Three Different Line Scanners (초점거리 편의가 지상 정확도에 미치는 영향 비교 연구 - 세가지 라인 스캐너를 대상으로 -)

  • Kim, Changjae
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.4_1
    • /
    • pp.363-371
    • /
    • 2014
  • Most space-borne optical scanning systems adopt linear arrayconfigurations. The well-knownthree different types of space-borne sensors arealong-track line scanner, across-track linescanner, and three line scanner. To acquire accurate location information of an object on the ground withthose sensors, the exterior and interior orientation parameters are critical factors for both of space-borne and airborne missions. Since the imaging geometry of sensors mightchange time to time due to thermal influence, vibration, and wind, it is very important to analyze the Interior Orientation Parameters (IOP) effects on the ground. The experiments based on synthetic datasets arecarried out while the focal length biases are changing. Also, both high and low altitudes of the imagingsensor were applied. In case with the along-track line scanner, the focal length bias caused errors along the scanline direction. In the other case with the across-track one, the focal length bias caused errors alongthe scan line and vertical directions. Lastly, vertical errors were observed in the case ofthree-line scanner. Those results from this study will be able to provide the guideline for developing new linearsensors, so as for improving the accuracy of laboratory or in-flight sensor calibrations.