• 제목/요약/키워드: Circulation Rate

검색결과 749건 처리시간 0.025초

Abyssal Circulation Driven by a Periodic Impulsive Source in a Small Basin with Steep Bottom Slope with Implications to the East Sea

  • Seung, Young-Ho
    • Ocean and Polar Research
    • /
    • 제34권3호
    • /
    • pp.287-296
    • /
    • 2012
  • In the theory of source-driven abyssal circulation, the forcing is usually assumed to be steady source (deep-water formation). In many cases, however, the deep-water formation occurs instantaneously and it is not clear whether the theory can be applied well in this case. An attempt is made to resolve this problem by using a simple reduced gravity model. The model basin has large depth change compared for its size, like the East Sea, such that isobaths nearly coincide with geostrophic contours. Deep-water is formed every year impulsively and flows into the model basin through the boundary. It is found that the circulation driven by the impulsive source is generally the same as that driven by a steady source except that the former has a seasonal fluctuation associated with unsteadiness of forcing. The magnitudes of both the annual average and seasonal fluctuations increase with the rate of deep-water formation. The problem can be approximated to that of linear diffusion of momentum with boundary flux, which well demonstrates the essential feature of abyssal circulation spun-up by periodic impulsive source. Although the model greatly idealizes the real situation, it suggests that abyssal circulation can be driven by a periodic impulsive source in the East Sea.

Numerical analysis of the temperature distribution of the EM pump for the sodium thermo-hydraulic test loop of the GenIV PGSFR

  • Kwak, Jaesik;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제53권5호
    • /
    • pp.1429-1435
    • /
    • 2021
  • The temperature distribution of an electromagnetic pump was analyzed with a flow rate of 1380 L/min and a pressure of 4 bar designed for the sodium thermo-hydraulic test in the Sodium Test Loop for Safety Simulation and Assessment-Phase 1 (STELLA-1). The electromagnetic pump was used for the circulation of the liquid sodium coolant in the Intermediate Heat Transport System (IHTS) of the Prototype Gen-IV Sodium-cooled Fast Reactor (PGSFR) with an electric power of 150 MWe. The temperature distribution of the components of the electromagnetic pump was numerically analyzed to prevent functional degradation in the high temperature environment during pump operation. The heat transfer was numerically calculated using ANSYS Fluent for prediction of the temperature distribution in the excited coils, the electromagnet core, and the liquid sodium flow channel of the electromagnetic pump. The temperature distribution of operating electromagnetic pump was compared with cooling of natural and forced air circulation. The temperature in the coil, the core and the flow gap in the two conditions, natural circulation and forced circulation, were compared. The electromagnetic pump with cooling of forced circulation had better efficiency than natural circulation even considering consumption of the input power for the air blower. Accordingly, this study judged that forced cooling is good for both maintenance and efficiency of the electromagnetic pump.

PIV에 의한 가정용보일러용 순환펌프의 내부 유동장 계측 (Measurement of Flow Field in a Domestic Boiler Circulation Pump by PIV)

  • 임유청;김재현;최민선;이영호
    • 동력기계공학회지
    • /
    • 제3권2호
    • /
    • pp.13-19
    • /
    • 1999
  • The purpose of the present experimental study is to apply multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to high-speed flow region within a domestic boiler circulation pump. Two different kinds of flow rate($27{\ell}/min,\;19{\ell}/min$)are selected as experimental condition. A volute casing and Impeller made of transparent Polycarbonate were made for the easy access of the illumination laser via fiber optical line and cylinder lens assembly to the measuring region. A CCD camera is syncronized with AOM to acquire clear original particle images. Optimized cross correlation identification to obtain velocity vectors is implemented by direct calculation of correlation coefficients. The instantaneous and time-mean velocity distribution, velocity profile and kinetic energy are represented quantitatively at the full-scale region for the deeper understanding of the unsteady flow characteristics in a commercial circulation pump.

  • PDF

지구 자전속도에 따른 해들리 순환과 제트의 반응 (The Response of Hadley Cell and Jet Stream to Earth's Rotation Rate)

  • 조종혁;김서연;손석우
    • 한국지구과학회지
    • /
    • 제40권3호
    • /
    • pp.203-211
    • /
    • 2019
  • 대기 대순환을 결정하는 주요 인자로는 남북방향 온도 경도와, 지구 자전으로 인한 코리올리 힘이 있다. 남북방향 온도 경도에 따른 경압성 차이로 인한 대기 대순환의 변화는 지금까지 많이 연구되어 왔으나, 자전속도에 따른 대기 대순환의 반응은 크게 연구되어 오지 않았다. 때문에 본 연구에서는 현 지구보다 느리거나 빠른 자전속도 범위를 모두 포괄하여 이에 따른 해들리 순환과 제트의 변화를 확인하였다. 이 연구에서 우리는 지구의 자전속도가 빨라질수록 해들리 순환 경계와 제트의 위치가 적도에 가까워지고, 제트와 해들리 순환의 세기가 약해진다는 것을 발견하였다. 해들리 순환 경계와 제트의 위치는 자전속도가 매우 빠르거나 느린 경우를 제외하면 준선형적인 관계를 가졌다. 특히, 해들리 순환 경계는 자전속도가 현재보다 1/8에서 8배의 자전속도 범위에서 자전속도보다 그 제곱근에 더 잘 반비례하는 경향성을 보였다. 단, 이러한 자전속도에 따른 변화는 해들리 순환 세기와 제트의 세기에 대해서는 뚜렷하지 않았다. 이는 대기 대순환의 위치 구조 변화는 지구 자전속도와 관련이 큰 반면, 세기의 변화는 자전속도로 설명되지 않음을 의미한다.

전시시나리오구조 유형별 관람행동특성에 관한 연구 - 자연과학계박물관을 중심으로 - (A Study on the Characteristics of Viewing Behaviors by the Composition Type Exhibition Scenarios - Focused on Natural Science Museums -)

  • 임채진;홍수미;김민아
    • 한국실내디자인학회논문집
    • /
    • 제15권4호
    • /
    • pp.106-114
    • /
    • 2006
  • The purposes of natural science museums are to educate the general public on the principles and application of science, and help them understand various aspects of science technology. Data should be analyzed by considering these educational aspects of exhibition, and the methods of presenting exhibits should be decided. Accordingly, the composition of exhibition contents with various exhibition elements has an important role at natural science museums. The relation and structure of exhibition themes are significant factors in helping visitors understand the principles of science and a system of viewing circulation can be used as an important tool for understanding the flow of exhibition. In other words, at the planning stage for the composition of exhibition contents, the relation of exhibition themes as well as the circulation patterns of viewers can induce active viewing behaviors. Therefore, centering on the patterns of viewing circulation as well as on the connectivity of exhibition themes at natural science museums, the purposes of this research are: 1) to conceptualize the composition of exhibition contents; and 2) to find elements that can induce active viewing behaviors by analyzing visitors' viewing behaviors. This research was establishing an analytical indicator of contact for viewing behaviors observed from the composition of exhibition scenarios, the active viewing patterns of engagement, first contact, and repeated contact were analyzed. First, a composition pattern with a high participation rate, in contact with exhibits, was found to induce an overall-viewing circulation and have a big ring of the composition of exhibition themes. Second, by inducing a partial-viewing circulation pattern, a high rate of first contacts was observed from a ring pattern of theme connection. Even for the structure with theme connection with depth, a high frequency of contacts with various exhibits was found when exhibition themes have a ring pattern. Third, the repeated contacts were mostly found in the form of scenarios, which has a successive structure of ring and cross patterns.

3구 노즐을 이용한 산소의 용존율 향상 (Enhance of Dissolved Oxygen Rate using a 3-prong Nozzle)

  • 박영식
    • 한국환경과학회지
    • /
    • 제24권7호
    • /
    • pp.947-954
    • /
    • 2015
  • Dielectric barrier discharge plasma is a new technique in water pollutant degradation, which that is characterized by the production of chemically active species such as hydroxyl radicals, ozone, hydrogen peroxide, etc. If dissolving of plasma gas generated in the plasma reaction has increased, it is possible to increase the contaminant removal capacity. In this study, the improvement on the dissolving performance of plasma gas was evaluated by the indirect method measuring the overall oxygen transfer coefficient. Experiments were conducted to examine the effects of nozzle type, distance from water surface, air supply rate and liquid circulation rate. The experimental results showed that the $K_{La}$ value of the 3-prong nozzle is 2.67 times higher than the diffuser. The order of $K_{La}$ value with nozzle type ranked in the following order: 3-prong nozzle (inner diameter, less 1 mm) > circular nozzle (inner diameter, 1.5 mm) > ellipse nozzle (short diameter 1 mm, long diameter 2.5 mm) > circular nozzle (inner diameter, 3 mm). Optimal liquid circulation rate was appeared to be 1.7 L/min, the value of $K_{La}$ was 0.510 1/min. The value of $K_{La}$ with increasing air supply rate was revealed in the form of an exponential such as $K_{La}=0.3581e^{0.2919^*air\;flow\;rate}$.

자동차용 토크 컨버터의 수치해석적 연구(Part I) - 수력학적 설계와 순환유량의 평가 - (A Numerical Study on the Automotive Torque Converter(Part I) - Hydraulic Design and Evaluation of Circulation Flow Rate -)

  • 김홍식;박재인;주원구;조강래
    • 한국자동차공학회논문집
    • /
    • 제6권5호
    • /
    • pp.28-36
    • /
    • 1998
  • In order to establish the hydraulic design process of the torque converter, pump, turbine and stator were designed by reverse design method including one dimensional analysis, angular momentum distribution and forced vortex design. And the significance of evaluation of the circulation flow rate in torus of the torque converter was verified by numerical calculation if the combined blade rows of pump and turbine. It was confirmed that the computational method using interrow mixing model by Park and Cho was reliable to predict the flow-field and performance of the torque converter.

  • PDF

Gas-lift를 이용한 극저온 추진제의 재순환 성능에 대한 실험 (Experimental Study on Cryogenic Propellant Circulation using Gas-lift)

  • 권오성;이중엽;정용갑
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.551-554
    • /
    • 2006
  • Inhibition of propellant temperature rising in liquid propulsion rocket using cryogenic fluid as a propellant is very important. Especially propellant temperature rising during stand-by after filling and pre-pressurization can bring into cavitation in turbo-pump. One of the method preventing propellant temperature rising in cryogenic feeding system is recirculating propellant through the loop composed of propellant tank, feed pipe, and recirculation pipe. The circulation of propellant is promoted through gas-lift effect by gas injection to lower position of recirculation pipe. In this experiment liquid oxygen and gas helium is used as propellant and injection gas. Under atmospheric and pressurized tank ullage condition, helium injection flow-rate is varied to observe the variation of recirculating flow-rate and propellant temperature in the feed pipe. There is appropriate helium injection flow-rate for gas-lift recirculation system.

  • PDF

Thermal-hydraulic simulation and evaluation of a natural circulation thermosyphon loop for a reactor cavity cooling system of a high-temperature reactor

  • Swart, R.;Dobson, R.T.
    • Nuclear Engineering and Technology
    • /
    • 제52권2호
    • /
    • pp.271-278
    • /
    • 2020
  • The investigation into a full-scale 27 m high, by 6 m wide, thermosyphon loop. The simulation model is based on a one-dimensional axially-symmetrical control volume approach, where the loop is divided into a series of discreet control volumes. The three conservation equations, namely, mass, momentum and energy, were applied to these control volumes and solved with an explicit numerical method. The flow is assumed to be quasi-static, implying that the mass-flow rate changes over time. However, at any instant in time the mass-flow rate is constant around the loop. The boussinesq approximation was invoked, and a reasonable correlation between the experimental and theoretical results was obtained. Experimental results are presented and the flow regimes of the working fluid inside the loop identified. The results indicate that a series of such thermosyphon loops can be used as a cavity cooling system and that the one-dimensional theoretical model can predict the internal temperature and mass-flow rate of the thermosyphon loop.

CO2 압축기의 운전조건과 오일토출의 상관분석에 관한 실험적 연구 (An Experimental Study on Correlation between Oil Discharge and Various Operating Conditions of a CO2 Compressor)

  • 이익수;강병하
    • 설비공학논문집
    • /
    • 제23권1호
    • /
    • pp.73-79
    • /
    • 2011
  • A portion of oil for lubrication of compressor flows together with refrigerant in the refrigeration system. If the oil discharge from a compressor is increased in the refrigeration system, not only pressure drop is increased in other components, such as evaporator and gas cooler, but also heat transfer coefficient in the heat exchangers is decreased. Oil discharge rate from a compressor may strongly depend on operating conditions of a compressor. In this study, one stage single rotary compressor is employed for measuring oil circulation ratio(OCR). Carbon dioxide and PAG oil are used as refrigerant and lubricant. Using a U-tube densimeter, mixture density is measured. Oil circulation ratio(OCR) can be estimated by measured mixture density. The results obtained indicate that the oil circulation ratio(OCR) is increased as the suction temperature or compressor operating frequency is increased. Oil circulation ratio(OCR) correlation of the compressor is also suggested.