• 제목/요약/키워드: Circulation Rate

검색결과 749건 처리시간 0.028초

An Implementation of DAQ and Monitoring System for a Smart Fish Farm Using Circulation Filtration System

  • Jeon, Joo Hyeon;Lee, Na Eun;Lee, Yoon Ho;Jang, Jea Moon;Joo, Moon Gab;Yoo, Byung Hwa;Yu, Jae Do
    • Journal of Information Processing Systems
    • /
    • 제17권6호
    • /
    • pp.1179-1190
    • /
    • 2021
  • A data acquisition and monitoring system was developed for an automated system of a smart fish farm. The fish farm is located in Jang Hang, South Korea, and was designed as circulation filtration system. Information of every aquaculture pool was automatically measured by pH sensors, dissolved oxygen sensors, and water temperature sensors and the data were stored in the database in a remoted server. Modbus protocol was used for gathering the data which were further used to optimize the pool water quality to predict the rate of growth and death of fish, and to deliver food automatically as planned by the fish farmer. By using JSON protocol, the collected data was delivered to the user's PC and mobile phone for analysis and easy monitoring. The developed monitoring system allowed the fish farmers to improve fish productivity and maximize profits.

Investigation of condensation with non-condensable gas in natural circulation loop for passive safety system

  • Jin-Hwa Yang;Tae-Hwan Ahn;Hwang Bae;Hyun-Sik Park
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.1125-1139
    • /
    • 2023
  • The system-integrated modular advanced reactor 100 (SMART100), an integral-type pressurized water small modular reactor, is based on a novel design concept for containment cooling and radioactive material reduction; it is known as the containment pressure and radioactivity suppression system (CPRSS). There is a passive cooling system using a condensation with non-condensable gas in the SMART CPRSS. When a design basis accident such as a small break loss of coolant accident (SBLOCA) occurs, the pressurized low containment area (LCA) of the SMART CPRSS leads to steam condensation in an incontainment refuelling water storage tank (IRWST). Additionally, the steam and non-condensable gas mixture passes through the CPRSS heat exchanger (CHX) submerged in the emergency cooldown tank (ECT) that can partially remove the residual heat. When the steam and non-condensable gas mixture passes through the CHX, the non-condensable gas can interrupt the condensation heat transfer in the CHX and it degrades CHX performance. In this study, condensation heat transfer experiments of steam and non-condensable gas mixture in the natural circulation loop were conducted. The pressure, temperature, and effects of the non-condensable gas were investigated according to the constant inlet steam flow rate with non-condensable gas injections in the loop.

Experimental and numerical assessment of helium bubble lift during natural circulation for passive molten salt fast reactor

  • Won Jun Choi;Jae Hyung Park;Juhyeong Lee;Jihun Im;Yunsik Cho;Yonghee Kim;Sung Joong Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.1002-1012
    • /
    • 2024
  • To remove insoluble fission products, which could possibly cause reactor instability and significantly reduce heat transfer efficiency from primary system of molten salt reactor, a helium bubbling method is employed into a passive molten salt fast reactor. In this regard, two-phase flow behavior of molten salt and helium bubbles was investigated experimentally because the helium bubbles highly affect the circulation performance of working fluid owing to an additional drag force. As the helium flow rate is controlled, the change of key thermal-hydraulic parameters was analyzed through a two-phase experiment. Simultaneously, to assess the applicability of numerical model for the analysis of two-phase flow behavior, the numerical calculation was performed using the OpenFOAM 9.0 code. The accuracy of the numerical analysis code was evaluated by comparing it with the experimental data. Generally, numerical results showed a good agreement with the experiment. However, at the high helium injection rates, the prediction capability for void fraction of helium bubbles was relatively low. This study suggests that the multiphaseEulerFoam solver in OpenFOAM code is effective for predicting the helium bubbling but there exists a room for further improvement by incorporating the appropriate drag flux model and the population balance equation.

Pilot 플라즈마 반응기를 이용한 하수 중 미생물의 불활성화 (Inactivation of Microorganisms in Sewage Using a Pilot Plasma Reactor)

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제39권3호
    • /
    • pp.289-299
    • /
    • 2013
  • Objectives: For the field application of the dielectric barrier discharge plasma reactor, scale-up of the plasma reactor is needed. This study investigated the possibility of inactivation of microorganisms in sewage using pilot multi-plasma reactor. We also considered the possibility of degradation of total organic carbon (TOC) and nonbiodegradable matter ($UV_{254}$) in sewage. Methods: The pilot plasma reactor consists of plasma reactor with three plasma modules (discharge electrode and quartz dielectric tube), liquid-gas mixer, high voltage transformers, gas supply equipment and a liquid circulation system. In order to determine the operating conditions of the pilot plasma reactor, we performed experiments on the operation parameters such as gas and liquid flow rate and electric discharge voltage. Results: The experimental results showed that optimum operation conditions for the pilot plasma reactor in batch experiments were 1 L/min air flow rate), 4 L/min liquid circulation rate, and 13 kV electric discharge voltage, respectively. The main operation factor of the pilot plasma process was the high voltage. In continuous operation of the air plasma process, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal condition of 13 kV were $10^{2.24}$ CFU/mL, 56.5% and 8.6%, respectively, while in oxygen plasma process at 10 kV, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal conditions were $10^{1.0}$ CFU/mL, 73.3% and 24.4%, respectively. Electric power was increased exponentially with the increase in high voltage ($R^2$ = 0.9964). Electric power = $0.0492{\times}\exp^{(0.6027{\times}lectric\;discharge\;voltage)}$ Conclusions: Inactivation of microorganisms in sewage effluent using the pilot plasma process was done. The performance of oxygen plasma process was superior to air plasma process. The power consumption of oxygen plasma process was less than that of air plasma process. However, it was considered that the final evaluation of air and oxygen plasma must be evaluated by considering low power consumption, high process performance, operating costs and facility expenses of an oxygen generator.

수처리용 유전체 장벽 방전 플라즈마 반응기 개발 (Development of Plasma Reactor of Dielectric Barrier Discharge for Water Treatment)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제21권5호
    • /
    • pp.597-603
    • /
    • 2012
  • Non-thermal plasma processing using a dielectric barrier discharge (DBD) has been investigated as an alternative method for the degradation of non-biodegradable organic compounds in wastewater. The active species such as OH radical, produced by the electrical discharge may play an important role in degrading organic compound in water. The degradation of N, N-Dimethyl-4-nitrosoaniline (RNO) was investigated as an indicator of the generation of OH radical. The DBD plasma reactor of this study consisted of a plasma reactor, recycling pump, power supply and reservoir. The effect of diameter of external reactor (15 ~ 40 mm), width of ground electrode (2.5 ~ 30 cm), shape (pipe, spring) and material (copper, stainless steel and titanium) of ground electrode, water circulation rate (3.1 ~ 54.8 cm/s), air flow rate (0.5 ~ 3.0 L/min) and ratio of packing material (0 ~ 100 %) were evaluated. The experimental results showed that shape and materials of ground were not influenced the RNO degradation. Optimum diameter of external reactor, water circulation rate and air flow rate for RNO degradation were 30 mm, 25.4 cm/s and 4 L/min, respectively. Ground electrode length to get the maximum RNO degradation was 30 cm, which was same as reactor length. Filling up of glass beads decreased the RNO degradation. Among the experimented parameters, air flow rate was most important parameters which are influenced the decomposition of RNO.

Different Climate Regimes Over the Coastal Regions of the Eastern Antarctic Ice Sheet

  • Cunde, Xiao;Dahe, Qin;Zhongqin, Li;Jiawen, Ren;Allison, Ian
    • Ocean and Polar Research
    • /
    • 제24권3호
    • /
    • pp.227-236
    • /
    • 2002
  • For ten firn cores, from both the eastern and the western side of Lambert Glacier basin (LGB), snow accumulation rate and isotopic temperature were measured far the recent 50 years. Results show that snow accumulation for five cores over the eastern side of LGB (GC30, GD03, GD15, DT001, and DT085) at Wilks Land and Princess Elizabeth Land increases, whereas it decreases at the western side (Core E, DML05, W200, LGB 16, and MGA) at Dronning Maud Land, Mizuho Plateau and Kamp Land. For the past decades, the increasing rate was $0.34-2.36kg\;m^{-2}a^{-1}$ at the eastern side and the decreasing rate was $-0.01\;-\;-2.36kg\;m^{-2}\;a^{-1}$ at the western side. Temperatures at the eastern LGB were also increased with the rate of $0.02%o\;a^{-l}$. At the western LGB it was difficult to see clear trends, which were confirmed by Instrumental temperature records at coastal stations. Although statistic analysis and modeling results display that both surface temperature and accumulation rate has increased trends in Antarctic ice sheet during 1950-2000, the regional distributions were much more different for different geographic areas. We believe that ice-core records at Wilks Land and Princess Elizabeth Land reflect the real variations of SST and moisture change in the southern India Ocean. For the Kamp Land and Dronning Maud Land, however circulation pattern was different, by which the climate was more complicated. The International Trans-Antarctic Scientific Expedition (ITASE) aimed to reveal an overall spatial pattern of climate change over Antarctic ice sheet for the past 200 years. This study points the importance of continental to regional circulation to annual-decadal scale climate change in Antarctica.

Airlift 생물반응기 (Airlift Bioreactors)

  • 류희옥;장용근김상돈
    • KSBB Journal
    • /
    • 제9권4호
    • /
    • pp.347-364
    • /
    • 1994
  • Airlift bioreactors are extensively used in the fields of aerobic fermentation, animal and plant cell cultures. This review article evaluates the present research activities in the field of airlift bioreactors. The published research works on the design parameters such as types, location and properties of gas sparser, hydrodynamic properties such as phase holdups mixing, liquid circulation rate, mass and heat transfer rates are summarized. Also, recommendations are presented for designing airlift bioreactors.

  • PDF

인조신경망을 이용한 좌심실보조장치의 동적 모델링

  • 김훈모
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.346-350
    • /
    • 1996
  • This paper presents a Neural Network Identification (NNI) method for modeling of highly complicated nonlinear and time varing human system with a pneumatically driven mock circulation system of Left Ventricular Assist Device(LVD). This system consists of electronic circuits and pneumatic driving circuits. The initation of systole and the pumping duration can be determined by the computer program. The line pressure from a pressure transducer inserted in the pneumatic line was recorded. System modeling is completed using the adaptively trained backpropagation learning algorithms with input variables, Heart Rate(HR), Systole-Diastole Rate(SDR), which can vary state of system, and preload, afterload, which indicate the systemic dynamic characteristics and output parameters are preload, afterload.

  • PDF

파랑에너지를 이용한 항내 해수순환증진에 대한 연구 (A Study on the Water Circulation Enhancement inside Harbor Utilizing Wave Energy)

  • 오병철;전인식;정태성;이달수
    • 한국해안해양공학회지
    • /
    • 제14권3호
    • /
    • pp.209-221
    • /
    • 2002
  • 본 논문에서는 파랑에너지를 이용하여 항외의 해수를 항내로 유도하여 항내의 해수순환을 향상시키는 방법에 대하여 검토하였다. 파랑에너지를 활용하여 항내의 해수순환을 도모하기 위한 해안구조물로서는 월류제를 채택하여 제주외항에 적용하고 그 효과를 확률적인 관점에서 정량적으로 평가하였다. 월류제를 통한 해수유입량은 파고와 조위에 의하여 결정되는 것으로 가정하였으며 해수유입율과 파고 및 조위간의 함수관계는 수리모형실험 결과로부터 구하였다. 파랑수치모형의 후산자료와 검조소의 조위관측자료로부터 계산된 파고와 조위의 확률분포로부터 월류제를 통한 해수유입량의 확률분포를 구하는 방법을 제시하여 제주 외항에 적용한 결과 월류제를 통한 유량의 확률분포는 Gamma 함수에 근접하는 것으로 나타났으며 월류제의 최적위치에 대해서도 논의하였다. 그리고 월류제의 유무에 따른 항내오염확산을 계산하여 월류제에 의한 항내수질정화효과를 평가하였다.