• Title/Summary/Keyword: Circulation Point

Search Result 278, Processing Time 0.024 seconds

A Study on Water Quality Impact by Pollution Source in Yongwon Channel, Busan Newport (부산신항 용원수로에서의 오염원별 수질영향 조사)

  • Kwon, Jae Hyun;Kim, Young Do;Jung, Jae Hoon;Jeong, Weon Mu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.2
    • /
    • pp.185-196
    • /
    • 2013
  • In Yongwon channel, its natural flow of seawater is blocked by the construction of Busan Newport including the container berth. The channel was transformed into a narrow and long one, where it is possible that ships are only allowed to pass through the north-side channel of Gyeonmado located at the point of river mouth to Songjeongcheon. In addition, Yongwon channel is approximately 100 m wide on average and 3,600 m long, which has the highest slenderness ratio (length/width=36). So it is considered that the changes in the terrain characteristics of Yongwon channel is likely to alter the circulation of sea water, thereby changing its water quality. In this study, the seasonal change and the spatial variation of the water quality in Yongwon channel was analyzed for the effect of land pollution using the measurement data. The mass balance calculation method is used to analyze the water pollution resulting from sediment pollutants. This result shows that the improvement of the water quality in Yongwon channel can be obtained from the sewer pipe modification and the environmental dredging.

A Study on the Seasonal Performances Evaluation of the Horizontal-type Geothermal Heat Exchanger Installed in the Foundation Slabs of Complex Building (주상복합 건축물의 기초 슬래브에 설치된 수평형 지열교환기의 계절별 성능평가)

  • Hwang, Kwang-Il;Woo, Sang-Woo;Kim, Joong-Hun;Shin, Seung-Ho;Kim, Yong-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.11-17
    • /
    • 2007
  • This study evaluates the seasonal performances of the horizontal-type geothermal heat exchanger(HGHEX) installed into the foundation slabs of the complex building located at Seoul. The geothermal system is consisted with totally 31,860m long HGHEX, 16 GSHPs (Ground-source Heat Pump) and 8 circulation pumps. This system supplies cooling and heating to the lobby(F1) and the common spaces(BF1). The average heat exchange temperature differences are $2.7^{\circ}C\;and\;2.5^{\circ}C$ in the summer, $1.5^{\circ}C\;and\;0.5^{\circ}C$ in the winter for the F1 and BF1 respectively. From these results, approximately 400Gcal and 180Gcal of geothermal energy are assumed to have been used during the summer and winter seasons respectively. As a conclusion, the geothermal system is reviewed as a effective utility for heating and cooling at the point of seasonal performances.

The Expanded XrML Model for Dynamic Digital License Management (동적 디지털 라이센스 관리를 위한 확장된 XrML모델)

  • Li Yong-Zhen;Mun Hyung-Jin;Lee Sang-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.2 s.40
    • /
    • pp.231-238
    • /
    • 2006
  • As digital contents circulation environment goes on-line by fast development of the latest Internet, contents demand is growing rapidly. However, XrML hard to change dynamically and has controversial point that hard to reflect user's request maximum after create license and issues to user, in this paper study of active digital license administration model who can reflect user request dynamically and support reusability of license XrML eXrML model who design extension design and suggested. Expect that this presents efficient administration plan in administration study of license base as well as study for digital contents administration.

  • PDF

Topology Optimization of Muffler Hole using Genetic Algorithm (유전자 알고리즘을 이용한 머플러 구멍 위상최적설계)

  • Wang, Semyung;Dikec, Altay;Hwang, Insoo;Kwon, Byoungha
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1205-1205
    • /
    • 2003
  • Rotary compressors are one of the most important parts of air-conditioners in the industry This device usually has noise problems during the circulation process of the refrigerant and muffler is used for the noise reduction. The acoustic performance of the muffler depends on its shape and its hole locations on the upper surface. Therefore finding the optimum location of the muffler holes is a topic of increasing importance in the compressor industry. In this research the optimization of the muffler hole locations and the importance of the resonator cavity on the lower surface of the muffler in acoustic point of view is studied. At first, the topology optimization for the 2 hole muffler is performed based on a model without resonator cavity by using genetic algorithm. The 2 hole muffler's acoustic analysis and experiment results are matching, however, the optimized model's results are not. By adding the resonator cavity and also by changing the cavity shape, the acoustic analysis and experiment result comparison is Performed for different cavity shapes. The topology optimization of the revised model with cavity is carried out for noise reduction. Finally, the optimized design is produced and tested for validation.

  • PDF

Centralized Educational Certificate Authentication System Using QR Cod Tag (QR코드를 이용한 통합 교육 자격 입증 시스템)

  • Abdurhman, Hamdi;Jang, Jong-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.271-274
    • /
    • 2017
  • An educational institution issued a degree certificate to those students who have successfully completed all studies included in different levels of the degree program. The degree certificate presented by the University is of major significance in the person's life but the fabrication and circulation of fake certificates is inexpensive because a paper document can easily be forged with the availability of advance printing and copying technologies. So, there is a need to adopt a centralized authentication process that can verify and ensure the authenticity of a document. In order to prevent the spread of fake degree certificates a method is proposed where the integrity of the contents with in the certificate can be verified with the use of and Smart Phone Application. A Quick Response (QR) Code will contain a digital signature over the data such as degree holder's name, major program, Grade Point Average (GPA) obtained etc. Which will be signed by university authorities after the registration in central system and deployed in university. In order to verify the digital signature a person need to use a specific smart phone application which will scan and authenticate the certificate without gaining access to a user's security credentials such as password.

  • PDF

A Study on the Space Constitution for the Complex of Educational Facilities - Focused on Public Space Formation for Composition of Complex with Welfare Facilities for the Aged - (교육시설의 복합화를 위한 공간구성에 관한 연구 - 고령자 복지시설과의 복합화를 위한 공용공간구성을 중심으로 -)

  • Kim, Jin-Mo
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.14 no.3
    • /
    • pp.27-35
    • /
    • 2007
  • The purpose of this research is to analyzing the welfare function of the senior citizen with similar type of compounding the school facility, to analyze the problematical point of present condition. And also propose the spatial constitution which the student and the regional senior citizen are easy to utilize on the basis of the result. In a type of educational facility composition, it became clear that a ratio and the inflection order that elderly welfare facilities occupied of vacant class room were low. In other words, in composition of a school facilities, elderly welfare facilities can be said to be an important problem. As a result of having analyzed an existing compound facilities, there was limited interchange of student and a the aged. In addition, there were problems such as learning environment by an intersection of circulation. Therefore, composition of educational facility and elderly welfare facilities is not space composition that is intersection of simple specification function. In other words, a program of the common space which is necessary for the local community formation is necessary. Setting of semi-public area proposes the function of the existing facility and actual condition of spatial use in prerequisite.

Numerical Simulation on the Heat Transfer Characteristics of a Solar Thermal Receiver Depending on the End-Wall Angle Variation (고온 태양열 흡수기의 후벽 각도 변화에 따른 열전달 특성에 관한 수치적 모사)

  • Jung, Eui-Guk;Boo, Joon-Hong;Kang, Yong-Hyeog
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2100-2105
    • /
    • 2008
  • A numerical analysis was conducted to predict the heat transfer characteristics of a high-temperature, high heat flux solar receiver as the end-wall angle varied. The concentration ratio of the solar receiver ranges from 200 to 1000 and the concentrated heat is required to be transported to a certain distance for specific applications. This study deals with a solar receiver incorporating high-temperature sodium heat pipe as well as a typical one that employs a molten-salt circulation loop with the same outer dimensions. The isothermal characteristics in the receiver section is of major concern. The diameter of the solar thermal receiver was 120 mm and the length was 400 mm. FLUENT, a commercial software, was employed to deal with the radiative heat transfer inside the receiver cavity and the convection heat transfer along the channels and heat pipes. The numerical results were compared and analyzed from the view point of heat transfer characteristics the solar receiver system.

  • PDF

An Experimental Study on Heat Transfer Characteristics in the LHSS for Cool Thermal Air Conditioning (저온공조용 잠열 축열조의 열전달 특성에 관한 실험적 연구)

  • Seo, I.H.;Koh, J.Y.;Lee, C.M.;Yim, C.S.
    • Solar Energy
    • /
    • v.20 no.3
    • /
    • pp.11-19
    • /
    • 2000
  • In this study, the basic data which were required for development of LHSS(latent heat storage system) were experimentally obtained. Experiments were carried out under the following conditions. The initial temperatures of P.C.M. which were used by parameter is $5^{\circ}C,\;9^{\circ}C$ and $14^{\circ}C$. The conditions of working fluid are $-6^{\circ}C,\;-4^{\circ}C$, and $65{\ell}$/min.. The pure water of which the freezing point is $0^{\circ}C$ was filled in the system, and the Ethylene glycol(brine) was circulated through the 10 vertical tubes as a secondary fluid in order to cool the P.C.M. down. The inlet temperature of the secondary fluid and the initial temperature of the water were varied to investigate the effects of the important design parameters. The phenomenons of temperature conversion of P.C.M. were appeared for the conductive heat transfer and free convective heat transfer by buoyancy force in this storage unit system. In order to find the effective water circulation path, we obtained P.CM. temperature distributions of 5 parts in the storage tank during freezing process.

  • PDF

Case Report of Facial Nerve Paralysis (안면신경마비의 치험례)

  • Cho, Sang-Hun;Park, June-Sang;Ko, Myung-Yun
    • Journal of Oral Medicine and Pain
    • /
    • v.26 no.2
    • /
    • pp.157-160
    • /
    • 2001
  • Facial nerve paralysis(or Bell's palsy) which commonly occurs unilaterally, gives rise to paralysis of facial expression muscle. This condition is classified into symptomatic facial nerve paralysis due to intracranial tumor, post operative trauma, etc. and idiopathic facial nerve paralysis. To explain the etiology of idiopathic facial nerve paralysis, many hypothesis including ischemic theory, viral infection, exposure to cold, immune theory etc. were suggested, but there is no agreement at this point. The method to evaluate the facial nerve paralysis, when it occurs, consists of three stage scale method, image thechnics like CT and MRI, laboratory test to examine the antibody titers of viral infection, neurophysiologic test to evaluate the degree and prognosis of paralysis. Treatment includes medication, stellate ganglion block(SGB), surgery, physical therapy and other home care therapy. In medication, systemic steroids, vitamins, vasodilating-drug and ATP drugs were used. SGB was also used repeatedly to attempt the improvement of circulation and to stimulate the recovery of nerve function. Physical therapy including electric acupuncture stimulation therapy(EAST) and hot pack was used to prevent the muscle atrophy. When No response was showed to this conservative therapies, surgery was considered. After treating two patients complaining of Bell's palsy with medication(systemic steroids) and EAST, favorable result was obtained. so author report the case of facial nerve paralysis.

  • PDF

A Study on Drug Traceability in Pharmaceutical Supply Chain (제약 공급망에서 의약품 유통 이력추적에 관한 연구)

  • Choi, Yong-Jung;Jung, Sang-Yun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.2
    • /
    • pp.197-208
    • /
    • 2015
  • Pharmaceutical companies over the world are exposed to risks of lessened sales and negative impact on corporate image due to circulation of counterfeit drugs, which eventually threatens safety of patients. thus, in order to eradicate distribution of counterfeit drugs, many countries are taking initiatives to legalize and set serialization through e-Pedigree, which is based on RFID technology or barcode system to track and trace distribution of drugs from point of manufacturing to usage. therefore, this study contemplates domestic and international management system of medical drugs and suggests application methods of e-Pedigree based on RFID technology that promotes safety of patients and distribution of drugs.