• 제목/요약/키워드: Circulating Fluidized Bed Boiler

검색결과 63건 처리시간 0.029초

3MWth급 순환유동층 바이오매스 가스화공정 개발 (Development of 3MWth Circulating Fluidized Bed Biomass Gasifier)

  • 이정우;송재헌;이동윤;최영태;양원;이은도
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.231-233
    • /
    • 2012
  • Circulating Fluidized Bed (CFB) is a technically and economically proven technology for boiler systems and large CFB coal boilers are making inroads into the domestic power boiler market. For biomass gasification, it is also considered as a very promising technology for commercial. Due to the lack of experiences of a large scale CFB gasifier, however, any large scale CFB gasifiers are hard to in Korea in spite of fast-growing demand of domestic market. In this study, a 3 $MW_{th}$ CFB gasifier was developed for biomass gasification. The CFB gasifier consists of interconnected fast and bubbling fluidized bed reactors including unique features for in-situ tar removal. Various numerical and experimental approaches will be presented such as basic modeling works, investigation of hydrodynamics with a cold model, computational particle fluid dynamics and experiments in the 3 MWth gasifier.

  • PDF

300 MW 급 유동층보일러에서 적정 층 물질량 산정 (Allowable Amount of Bed Inventory in a 300 MW Class Circulating Fluidized Bed Boiler)

  • 김우용;유호선
    • 플랜트 저널
    • /
    • 제14권2호
    • /
    • pp.33-38
    • /
    • 2018
  • 본 연구에서는 순환유동층보일러의 베드가 과열되어 층 물질의 소결이 발생하고 노 내 유동물질에 의해 보일러튜브가 마모 되는 것을 최소화하기 위하여, 노 하부 베드의 층 물질량 조정을 통한 베드 온도 변화를 실험적으로 연구하였다. 실험은 300MW급 순환유동층보일러인 여수화력 2호기를 대상으로 하였으며 터빈출력, 석탄소비량, 공기량 등을 고정한 상태에서 층 물질 양을 감소시켜 베드 압력을 설계값 4.5KPa에서 2.5KPa까지 감소시켰다. 결론적으로 층 물질 양을 적정하게 줄이면 베드 온도가 저하 되나, 지속적으로 저하되지 않는 것을 확인 하였으며, 베드 압력 3.0KPa, 즉 베드 물질량 110 톤을 변곡점으로 하여 베드 온도는 상승하기 시작하였다. 층 물질량이 충분히 많은 상태에서, 층 물질량이 감소되면 베드 온도는 저하되며, 층 물질량이 적정량 보다 적으면 노 내 유동물질의 순환량 감소로 베드 온도는 상승함을 알 수 있었다. 또한 유동층보일러에서 베드 온도 변화는 단순히 층 물질의 양 뿐만 아니라, 보일러 용량 및 연료의 성상 등에 따라 변화 추이가 매우 다양하게 나타난다는 것을 알 수 있었다.

  • PDF

저급탄용 순환유동층 보일러 발전설비의 경제성 평가 (Economic Feasibility of Circulating Fluidized Bed Combustion Boiler Power Plant for Low Grade Coal)

  • 홍민표;문승재
    • 플랜트 저널
    • /
    • 제8권1호
    • /
    • pp.73-80
    • /
    • 2012
  • The structure and combustion characteristics, and the economic feasibility of the circulating fluidized bed combustion(CFBC) boiler using low grade coal were introduced. The economic feasibility is evaluated by comparing a 500 MW CFBC boiler power plant using low grade coal and a pulverized combustion boiler power plant with high grade coal. As the result of the evaluation, the pulverized coal combustion boiler power plant has an internal rate of return of 12.95%, 1,395.9 billion Korean won of net present value, and 6.26 years of payback period. On the other hand, CFBC boiler power plant has an internal rate of return of 13.54%, 1,704.3 billion Korean won of net present value, and 6.02 years payback period. Therefore, the CFBC boiler power plant has better feasibility in all aspects, as 0.59% higher of internal rate of return, 308.4 billion Korean won of higher net present value and 0.24 year of shorter payback period.

  • PDF

Carbonation of Circulating Fluidized Bed Boiler Fly Ash Using Carbonate Liquids

  • Lee, Woong-Geol;Kim, Jin-Eung;Jeon, Se-Hoon;Song, Myong-Shin
    • 한국세라믹학회지
    • /
    • 제54권5호
    • /
    • pp.380-387
    • /
    • 2017
  • In this study, unstable CaO was converted into a stable Ca compound by using carbonation in a circulating fluidized bed boiler of fly ash to confirm material usability as cement admixture; also undertaken was carbonation test and mortar to examine chemical and physical change by measuring absorption rate and compressive strength. To investigate the chemical properties of circulating fluidized bed boiler fly ash, XRD and TG-DTA were used to determine how the properties of the reaction product change quantitatively during carbonation. In order to stabilize CaO, carbonation of CaO is considered to be the most desirable process. This is because $CaCO_3$, which is a Ca compound, was produced by carbonate reaction of unstable CaO, and decrease of the absorption rate and improvement of the compressive strength were observed when the carbonated fly ash was replaced with cement.

순환유동층보일러 외부열교환기의 열전달 특성에 관한 수치해석적 연구 (A Numerical Study of the Characteristics of Heat Transfer in External Heat Exchanger of CFB Boiler)

  • 황문경;김정래
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.15-16
    • /
    • 2014
  • With the increasing trend in CFB(Circulating Fluidized Bed) boiler scale, the EHE(External Heat Exchanger) must be adopted to the large-scale boilers to recover insufficient heat transfer surface. In this study, the numerical analysis model for EHE in commercial 300MWe CFB boiler was developed with the inclusion of mechanistic model, which enables the heat transfer prediction. Finally, the calculated absorbed heat and derived heat transfer coefficient are evaluated through the verification with experimental data.

  • PDF

Pilot 순환유동층 연소장치에서의 목재펠릿과 아역청탄 혼소 특성 (Characteristics of Co-Combustion of Wood Pellet with Sub-Bituminus Coal in A Pilot CFB Combustor)

  • 김동원;박경일;이종민;배용채
    • 한국수소및신에너지학회논문집
    • /
    • 제30권5호
    • /
    • pp.436-447
    • /
    • 2019
  • The circulating fluidized bed boiler has an advantage that can burn a variety of fuels from low-grade fuel to coal. In this study, for the design of a circulating fluidized bed boiler using wood pellets, a circulating fluidized bed combustion test device using no external heater was manufactured and used. According to the increase of co-combustion rate with wood pellet, combustion fraction and heat flux by combustor height were measured and pollutant emission characteristics were analyzed. In terms of combustibility, the effect on primary and secondary air ratio were also studied. In addition, as a result of analysis of the effect of corrosive nanoparticles on the combustion of coal with wood pellets, it was confirmed that coal is mostly composed of Ca and S, whereas wood pellets are mostly composed of K, Cl, and Na.

순환유동층에서 폐수슬러지와 석탄의 혼소 특성 (Incineration of Waste Water Sludge and Coal In a Circulating Fluidized Bed Combustor)

  • 배달희;선도원;박재현;류호정;박도현
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제28회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.165-172
    • /
    • 2004
  • Co-incineration of coal and wastewater sludge was r;erfonn:rl in a O.lMWth bench scale circulating fluidized bed combustor(CFBC) Sludge was received from a wastewater treatment plant in a dye industrial complex in Busan. Metropolis. Moisture content of received sludge was 80%. Coal and sludge mixture was prepared with weight ratio of 90/10, 85/15 and 80/20. Co-combustion characteristics of the coal and sludge mixture demonstrated stable combustion conditions. Component analysis, incineration characteristics, boiler performance was measured before and after the test and application for commercial 59MWth CFBC boiler. The release of hazardous components such as $SO_2$ and Cl was suppressed by the presence of inherent minerals of Ca, Na, K in coal and sludge mixture. Pre-drying was not essential but it was recommended for the benefits of manageability of sludge.

  • PDF

순환 유동층 보일러 제어 (A Circulating Fluidized Bed Boiler Control)

  • 김응석;이찬주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.722-724
    • /
    • 1998
  • One of the major concerns of our time is the need to use energy economically and rationally while at the same time, protecting the environment. Circulating Fluidized Bed(CFB) Boilers represent a proven, very attractive clean coal technology, with the added advantage of an unusual fuel flexibility CFB boiler is the best available compromise between cost and environment for fossil fuel power plant. This paper briefly describes CFB process and 200MW CFB boiler for Tonghae power plant. Also, discussed are differences between the control process of fluidized bed and conventional boilers, and applied control process for Tonghae power plant.

  • PDF

순환유동층 보일러에서 무연탄-유연탄의 혼합연소 특성 (Co-combustion Characteristics of Mixed Coal with Anthracite and Bituminous in a Circulating Fluidized Bed Boiler)

  • 정의대;문승재
    • 플랜트 저널
    • /
    • 제6권2호
    • /
    • pp.70-77
    • /
    • 2010
  • This study investigated the characteristics of co-combustion of mixed anthracite (domestic and Vietnam) and bituminous coal (Sonoma, Australia) at circulating fluidized bed boiler in Donghae thermal power plant when mixing ratio of bituminous coal is variable. Co-combustion of bituminous coal contributes to improvement in general combustion characteristics such as moderately retaining temperature of furnace and recycle loop, reducing unburned carbon powder, and reducing discharge concentration of NOx and limestone supply owing to improvement in anthracite combustibility as the mixing ratio was increased. However, bed materials were needed to be added externally when the mixing ratio exceeded 40% because of reduction in generating bed materials based on reduction in ash production. When co-combustion was conducted in the section of 40 to 60% in the mixing ratio while the supplied particles of bituminous coal was increased from 6 mm to 10 mm, continuous operation was shown to be possible with upper differential pressure of 100 mmH2O (0.98 kPa) and more without addition of bed materials for the co-combustion of mixed anthracite and bituminous coal (to 50% or less of the ratio) and that of domestic coal and bituminous coal (to 60% of the ratio).

  • PDF

순환유동층보일러의 과열기 튜브 부식에 알칼리 금속과 염소가 미치는 영향 (Effects of Alkali Metals and Chlorine on Corrosion of Super Heater Tube in Biomass Circulating Fluidized Bed Boiler)

  • 백승기;유흥민;장하나;정현태;서용칠
    • 공업화학
    • /
    • 제28권1호
    • /
    • pp.29-34
    • /
    • 2017
  • 본 연구에서는 순환유동층 보일러 과열기 튜브의 부식 원인물질을 규명하여, 부식방지를 위한 방안을 모색하고자 하였다. 연료, 과열기 튜브 부식부위, 과열기 튜브에 부착된 재 및 보일러 재를 채취하여 성분분석을 수행하였다. 과열기 튜브 부식부위에서 산화로 인한 O성분이 함유되어 있는 것을 확인하였다. 과열기 튜브 부착 재 및 보일러 재에서 6.1% 및 4.3%의 Cl이 분석되었으며, 이는 설계값의 약 14-20배 정도 높은 수치이다. 또한 알칼리 금속물질(K, Na, Ca)의 함량이 매우 높게 분석되었다. XRF 데이터를 이용하여 보일러에서 재의 슬래깅과 파울링에 대한 영향을 예측하였다. Basicity는 과열기 튜브 부착 재 및 보일러 재에서 각각 3.62 및 2.72로 산정되었으며, 설계값인 0.35에 비하여 높은 수치를 갖는 것으로 확인되었다.