• Title/Summary/Keyword: Circulating Fluidized Bed

Search Result 188, Processing Time 0.025 seconds

Mechanism of Fouling Reduction and Heat Transfer Enhancement in a Circulating Fluidized Bed Heat Exchanger (순환유동층 열교환기 내의 화울링 저감 및 열전달 향상 기구)

  • Lee, Y.P.;Yoon, S.Y.;Jurng, J.S.;Kim, N.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.450-460
    • /
    • 1995
  • A modified circulating fluidized bed heat exchanger under severe fouling condition is developed. The effects of fouling deposits on the performance of a heat exchanger are investigated. The principle and operating characteristics of a circulating fluidized bed heat exchanger are dicussed. A modified circulating fluidized bed heat exchanger shows more stable operating than the other circulating fluidized bed heat exchanger. The characteristics of self cleaning and heat transfer enhancement of a circulating fluidized bed heat exchanger are studied. The movement of spherical particles in a tube is visualized and heat transfer enhancement and scale reduction mechanism by particles are investigated.

  • PDF

Introduction and Current Status of Ultra Supercritical Circulating Fluidized Bed Boiler (초초임계 순환유동층 보일러 기술 소개 및 현황)

  • Lee, Si-Hun;Lee, Jong-Min
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.211-221
    • /
    • 2016
  • The increase of world's population and economic development are the keys drivers behind growing demand for energy. Especially the demand for electricity would eventually result in an increase of coal usage. Therefore ultra supercritical circulating fluidized bed boiler has been developed as solutions of economic eco-friendly technologies for coal and of increasing supplies of low grade fuels. Ultra supercritical circulating fluidized bed boiler has an once through type of steam cycle different from drum type in subcritical circulating fluidized bed boiler. Also, the duplication of a proven commercial module with 100-300 MWe subcritical circulating fluidized bed might be the key for design of 500~800 MWe ultra supercritical circulating fluidized bed boiler. After 2017, ultra supercritical circulating fluidized bed boiler might become standard model over subcritical circulating fluidized bed boiler. Therefore, this paper will help you to understand ultra super critical circulating fluidized bed (USC-CFB) through describing the background, status and prospect of the CFB technology.

Comparative Evaluation of Large-scale Circulating Fluidized Bed (CFB) Boiler Concepts (대용량 순환유동상 보일러 개념 비교평가 기준 정립)

  • Kim, Tae-Hyun;Choi, Sang-Min;Lee, Jong-Min
    • Journal of the Korean Society of Combustion
    • /
    • v.14 no.3
    • /
    • pp.1-15
    • /
    • 2009
  • The circulating fluidized bed (CFB) boiler has some problems to scale up. Several engineering solutions have been proposed by a few suppliers which had advanced CFB technology. Large-scale CFB design concepts from different suppliers were reviewed and compared. Points of the hydrodynamic and heat recovery were summarized and discussed for developing the guideline of the large-scale circulating fluidized bed boilers.

  • PDF

Research on the Replacement of Bed Material and Multifunctional Additives in Circulating Fluidized Bed Combustion Using Solid Fuels (고형연료사용 순환유동층 연소로에서의 유동사 대체 및 다기능성 첨가제에 관한 연구)

  • Park, In su;Nam, Jeong soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.115-116
    • /
    • 2023
  • In this study, it was confirmed whether kaolin can play a role as a bed materials and a role in reducing clinkers by using kaolin with a bed materials for the purpose of removing clinkers such as slagging and fouling generated in circulating fluidized bed combustion furnaces using solid fuel.

  • PDF

Technical Development for the Circulating Fluidized Bed Combustor of firing Korean Low Grade Anthracite Coals (Particle Flow Patterns in a Circulating Fluidized-Bed with an internal Nozzle and a Partition Wall) (한국산 저질무연탄 연소용 순환식유동층 연소로 개발(간막이벽과 내부노즐을 설치한 순환유동층내에서의 유체거동))

  • Khee, Kwan-Seok
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.6 no.4
    • /
    • pp.243-248
    • /
    • 1993
  • A Circulating Fluidized-Bed (CFB) with an internal nozzle and a partition wall was proposed. The technique of fluidization is related to operations first used commercially in the fields of metallurgical and mechanical engineering such as the heat treatment of metals and power station combustors. In the modified CFB, an internal nozzle and a partition wall were additionally set in the main bed. This cold mode CFB apparatus made of acrylic resin; the main bed is 1,500mm high and 100mm in the inner diameter, the internal nozzle is 130mm high and 10mm in the inner diameter, and the partition wall is 7mm thick and 100mm in the diameter. Glass beads of $89{\mu}m$ in the mean diameter were employed as bed materials.

  • PDF

Circulating Fluidized Bed Combustion of Refuse Derived Fuel (폐기물 연료의 순환유동층 연소기술)

  • Shun Dowon;Bae Dal-Hee;Lee Seung-Yong;Jo Sung-Ho
    • Resources Recycling
    • /
    • v.15 no.1 s.69
    • /
    • pp.58-65
    • /
    • 2006
  • A new technology for refused derive fuel(RDF) utilization in circulating fluidized bed is under development. The RDF is tested in a bench scale circulating fluidized bed(CFB) combustor and its burning characteristics were investigated and collected as design parameters. The combustions were controllable and the HCl emission which is most important toxic emission were below 150 ppm at the exit of the combustor. The differences between conventional coal homing circulating fluidized bed boiler and the exclusive RDF boiler were studied and commercial scale co-generation CFB for RDF was designed.

Circulating Fluidized Bed Combustion of Refuse Derived Fuel (폐기물 연료의 순환유동층 연소기술)

  • Shun, Do-Won;Bae, Dal-Hee;Lee, Seung-Yong;Jo, Sung-Ho
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 2005.10a
    • /
    • pp.124-134
    • /
    • 2005
  • A new technology for refused derive fuel(RDF) utilization in circulating fluidized bed is under development. The RDF is tested in a bench scale circulating fluidized bed(CFB) combustor and it's burning characteristics were investigated and collected as design parameters. The combustions were controllable and the HCl emission which is most important toxic emission were below 150ppm out of combustor. The differences between conventional coal burning circulating fluidized bed boiler and the exclusive RDF boiler were studied and commercial scale co-generation RDF CFB's were designed.

  • PDF

Development of Circulating Fluidized Bed Boiler for Refused Derived Fuel (RDF연소를 위한 순환유동층보일러개발)

  • Bae, Dal-Hee;Shun, Do-Won
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.71-77
    • /
    • 2005
  • Combustion of RDF and wastewater sludge was performed in a 0.1MWth bench scale circulating fluidized bed combustor(CFBC), Combustion characteristics of the RDF and sludge mixture demonstrated stable combustion conditions. Component analysis, Combustion characteristics was measured before and after the test, and applications for commercial 1MWe CFBC boiler were prepared. The release of hazardous components such as $SO_2$ and HCl was relatively low values of 50 and 150ppm, respectively.

  • PDF

Performance Simulation of Part Load Operation for 2MWe Circulating Fluidized Bed Boiler (2MWe 순환유동상 보일러의 부분 부하 운전 성능 모사)

  • Kim, Taehyun;Choi, Sangmin;Hyun, Ju-soo
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.35-36
    • /
    • 2012
  • Part load operation usually covers large periods of the total operation time on the economic ground and electricity demand in small-scale boilers. Performance analysis of part load behavior is very important for the purpose of boiler operation optimization. A simple thermal calculation approach is applied to predict performance of a pilot-scale circulating fluidized bed (CFB) boiler at part load operation. Verification has been carried out by comparing between calculation results an operation data of the boiler.

  • PDF

A Study on Design Characteristics of Yeosu Circulating Fluidized Bed Boiler (여수화력 순환유동상 보일러의 설계특성 고찰)

  • Kim, Jae-Sung;Lee, Jong-Min;Kim, Dong-Won;Kim, Tae-Hyun;Choi, Sang-Min
    • Journal of the Korean Society of Combustion
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • 340 MWe circulating fluidized bed (CFB) boiler in Yeosu power station is under construction. The circulating fluidized bed boiler in the Yeosu power plant has a number of differences from other domestic boilers in terms of scale and design. Evaluation of design parameters of the Yeosu CFB boiler should be required because the direct application of existing technology is limited. In this study, design characteristics of the Yeosu CFB boiler was summarized. And thermogravimetric analysis was conducted with comparing other rank coals. Watersteam side heat absorption, flue gas temperature and heat transfer coefficient were calculated by heat and mass balance. Design parameters for the Yeosu CFB boiler were discussed along with typical value in the CFB design range.