• 제목/요약/키워드: Circular tube

검색결과 554건 처리시간 0.026초

Static strengths of preloaded circular hollow section stub columns strengthened with carbon fiber reinforced polymer

  • Chen Wei;Yongbo Shao;Mostafa Fahmi Hassanein;Chuannan Xiong;Hongmei Zhu
    • Steel and Composite Structures
    • /
    • 제47권4호
    • /
    • pp.455-466
    • /
    • 2023
  • To investigate the load bearing capacity of axially preloaded circular hollow section (CHS) stub columns strengthened by carbon fiber reinforced polymer (CFRP), theoretical analysis is carried out. The yield strength and the ultimate strength of a CFRP strengthened preloaded CHS stub column are determined at the yielding of the CHS tube and at the CFRP fracture, respectively. Theoretical models are proposed and corresponding equations for calculating the static strengths, including the yield strength and the ultimate strength, are presented. Through comparison with reported experimental results, the theoretical predictions on the static strengths are proved to be accurate. Through finite element (FE) analyses, parametric studies for 258 models of CFRP strengthened preloaded CHS stub columns are conducted by considering different values of tube diameter, tube thickness, CFRP layer and preloading level. The static strengths of the 258 models predicted from presented equations are proved to be in good agreement with FE simulations when the diameter-to-thickness ratio is less than 90ε2. The parametric study indicates that the diameter and the thickness of the steel tube have great effects on CFRP strengthening efficiency, and the recommended ranges of the diameter and the thickness are proposed.

측면하중을 받는 트러스형 내부구조를 가지는 샌드위치 튜브의 특성 (The Characteristics of a Sandwich Tube with a Truss Core under Lateral Loading)

  • 정창균;성대용;양동열;문경제;안동규
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 춘계학술대회 논문집
    • /
    • pp.268-271
    • /
    • 2007
  • A sandwich tube is a structured material that has two inner and outer circular tubes and light material between them. In this paper, a sandwich tube with a pyramidal truss core is introduced. Fabrication method and example made by brazing are shown. The behavior of the sandwich tube under lateral loading is predicted by analytical and numerical method. Comparative study between the sandwich and the monocoque tube is performed at a point of view such as strength and weight saving. As a result, proposed tube is appropriate for application to lightweight structural material

  • PDF

일정 축력을 받는 콘크리트충전 원형 강관기둥의 내화성능 평가 (Fire Resistance of Concrete-Filled Circular Steel Tube Columns under Central Axial Loads)

  • 박수희;송경철;류재용;정경수;최성모
    • 한국강구조학회 논문집
    • /
    • 제20권5호
    • /
    • pp.655-663
    • /
    • 2008
  • 본 연구에서는 콘크리트충전 원형강관(원형 CFT)기둥의 내화성능을 평가하기 위하여 수치해석을 수행하였다. 강관은 SPSR 400 강재를 사용하였으며 강관 내에는 27.5MPa와 37.8MPa 강도의 콘크리트를 사용하였다. 콘크리트 강도, 작용 축력, 단면 직경을 변수로 설정하였다. 수치해석의 정확성을 검증하기 위하여, 기존의 각국 내화성능설계식들에 의한 계산 결과값과 비교 평가 하였다. 또한, 기존의 실대 원형 CFT기둥의 내화성능 평가 실험 결과와 함께 비교 분석하여 수치해석의 타당성을 검증하였다. 원형 CFT기둥의 내화실험 및 수치해석적 연구를 통해 도출된 내화저항시간과 축력비, 단면직경, 콘크리트 강도의 영향을 각형 CFT기둥의 내화성능과 비교 분석하여 각 영향인자들의 영향을 평가하였다. 본 연구의 수치해석적 연구는 실험결과와 비슷한 거동 및 내화성능을 보였다. 따라서 본 연구에서의 수치해석에 의한 CFT기둥의 내화 성능 예측은 타당하다고 판단된다.

CFRP 튜브의 결함형상.결함깊이.레이디얼 하중에 따른 와전류 신호의 변화 (Variation of Eddy Current Signal According to the Defect Shape, Defect Depth and Radial Load in CFRP Tube)

  • 송삼홍;안형근;이정순;오동준;송일;김철웅
    • 대한기계학회논문집A
    • /
    • 제28권12호
    • /
    • pp.2004-2011
    • /
    • 2004
  • The applicability of the ultrasonic C-scan inspection is restricted due to the deterioration of mechanical properties of specimen during the test. Therefore, the aim of this research is applied to Eddy Current (EC) test substitute for the C-scan inspection in CFRP tube containing defects. This research is to evaluate the EC signals for the inspection of CFRP tube containing various circular hole defects (20% to 100% depth to the specimen thickness) using the unloading specimen and radial loading specimen. This study was considered the following points; 1) Analysis of EC signals for the inspection of saw-cut defect and circular hole defect, 2) The evaluation of defect depths and EC signals relationship. 3) Variation of EC signal owing to the radial load. In conclusions, the high frequency such as 300∼500 kHz made it possible to the inspection of 40% to 100% defects. Particularly, in case of 20% defect, the EC signal was not detected due to the noise of micro-crack and delamination. While the depth of the hole defects were decreasing, the difference of the phase angle between unloading specimen and radial loading specimen was gradually increasing.

내부 강관 보강 원형 R.C 기둥의 연성 거동 특성 (Ductility of Circular Hollow Reinforced Concrete Piers Internally Confined by a Steel Tube)

  • 한택희;한상윤;한금호;강영종
    • 한국방재학회 논문집
    • /
    • 제3권2호
    • /
    • pp.127-137
    • /
    • 2003
  • 구조적으로 콘크리트의 자중이 문제 시 되는 곳이나, 콘크리트의 재료비가 높은 경우, 수직부재로 중공 콘크리트의 사용이 경제적일 수 있다. 콘크리트의 구속효과를 발휘를 위해 외측 면을 띠철근으로 보강하고 내측 면에 강관을 삽입하여 보강한 원형 중공 콘크리트 기둥의 연성 거동에 관해 연구하였고, 압축강도와 콘크리트의 극한변형율을 증가시키는 구속력의 효과를 나타낸 Mander의 응력-변형률 관계를 사용하여, 모멘트-곡률 관계 해석을 유도하였다. 극한변형율에 영향을 주는 인자인 구속력을 발휘하는 철근의 철근비와 항복응력, 구속 콘크리트의 압축강도 등을 극한변형율과 횡철근비의 관계를 통하여, 강관 삽입된 원형 중공 철근콘크리트 기둥의 구속응력과 횡철근비의 관계식을 제안하였다. 제안된 횡철근비 관계식은 실험을 통하여 검증하였다.

A novel prediction model for post-fire elastic modulus of circular recycled aggregate concrete-filled steel tubular stub columns

  • Memarzadeh, Armin;Shahmansouri, Amir Ali;Poologanathan, Keerthan
    • Steel and Composite Structures
    • /
    • 제44권3호
    • /
    • pp.309-324
    • /
    • 2022
  • The post-fire elastic stiffness and performance of concrete-filled steel tube (CFST) columns containing recycled aggregate concrete (RAC) has rarely been addressed, particularly in terms of material properties. This study was conducted with the aim of assessing the modulus of elasticity of recycled aggregate concrete-filled steel tube (RACFST) stub columns following thermal loading. The test data were employed to model and assess the elastic modulus of circular RACFST stub columns subjected to axial loading after exposure to elevated temperatures. The length/diameter ratio of the specimens was less than three to prevent the sensitivity of overall buckling for the stub columns. The gene expression programming (GEP) method was employed for the model development. The GEP model was derived based on a comprehensive experimental database of heated and non-heated RACFST stub columns that have been properly gathered from the open literature. In this study, by using specifications of 149 specimens, the variables were the steel section ratio, applied temperature, yielding strength of steel, compressive strength of plain concrete, and elastic modulus of steel tube and concrete core (RAC). Moreover, parametric and sensitivity analyses were also performed to determine the contribution of different effective parameters to the post-fire elastic modulus. Additionally, comparisons and verification of the effectiveness of the proposed model were made between the values obtained from the GEP model and the formulas proposed by different researchers. Through the analyses and comparisons of the developed model against formulas available in the literature, the acceptable accuracy of the model for predicting the post-fire modulus of elasticity of circular RACFST stub columns was seen.

Hydroforming을 이용한 Tube 의 예비 가공형 설계 (Preform Designin Tube by Using the Hydroforming)

  • 이한남
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 춘계학술대회논문집
    • /
    • pp.39-44
    • /
    • 1999
  • Hydroforming is a forming process enabling circular metal tubes to be produced in complex cross sections along curved axial paths With the availability of advanced machine design and control They offer advantages over stamped sheet metal in lower tooling cost and structural mass The technology is relatively new so that there is no large knowledge base to assist the fundamentals of tube hydroforming technology. The purpose of this paper is found that adaptive bending condition and contact condition for bended part has uniform thickness distribution.

  • PDF

형상이 다른 수평 원형 전열관의 응축 성능에 관한 연구 (A Study on the Condensation Performance for the Horizontal Heat Transfer Tubes with Various Fin Attached)

  • 한규일;박종운
    • 수산해양교육연구
    • /
    • 제4권1호
    • /
    • pp.47-61
    • /
    • 1992
  • An experimental study was carried out to investigate the condensation performance for the horizontal cylindrical heat transfer tube with various fin attached using R-11 vapor. The heat transfer tube used in this study was supplied by SUNG HYUNG METAL CO., LTD. Four different types of heat transfer tubes (plain tube, SH-CYR tube, thermocor tube and thermoexcel tube) were used. Each tube was surrounded by circular acrylate tube, and R-11 gas heated by boiler flows into the acrylate tube. Cooling water counter-flows in heat transfer tubes. Heat transfer coefficient of the plain tube from measured data was compared with those of three other tubes. The results are summarized as follows: 1. As the cooling water temperature decreased, the liquid film of R-11 turned to droplet drop on the top surface of the horizontal tube. 2. Heat transfer coefficient calculated theoretically was higher than that obtained from the experimental data. 3. As far as the condensation concerns the thermocor tube is the highest, the SH-CYR tube is the second, and the thermoexcel tube is the third excluding the plain tube.

  • PDF

환형 T-5램프용 복합 전자식 안정기 개발 (Development of Dimming Ballast for T-5 Circular Fluorescent Lamps)

  • 오철성;조성권;이홍호;여진기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.871-874
    • /
    • 2003
  • The T-5 Lamps developed in 1996 is the high efficiency fluorescent lamps, the lamps voltage is high, and the lamps current small because the lamps are slender tube of 16mm diameter. And so, the electrical characteristics of the Ballast for the lamps are different from of the Ballast for T-10 or T-8 lamps. Therefore, the know-how of the exclusive Ballast for the T-5 fluorescent lamps should be as soon as possible. We described the electrical and optical characteristics of the Electronic Ballast for T-5 Circular Fluorescent lamps. The developed Electronic dimming Ballast for T-5 Circular Fluorescent lamps has the 45% energy saving effects than the T-10 lamps. And it has the promotion of the THD less than 10%, CF less than 1.5%, Flickering less than 5% and 99% power factor. And it is available for two T-5 Circular fluorescent Lamps dimming, 22W and 40W.

  • PDF