• Title/Summary/Keyword: Chromium catalyst

Search Result 32, Processing Time 0.015 seconds

Kinetics and Mechanism of the Oxidation of Alcohols by C9H7NHCrO3Cl (C9H7NHCrO3Cl에 의한 알코올류의 산화반응에서 속도론과 메카니즘)

  • Park, Young-Cho;Kim, Young-Sik;Kim, Soo-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.378-384
    • /
    • 2018
  • $C_9H_7NHCrO_3Cl$ was synthesized by reacting $C_9H_7NH$ with chromium (VI) trioxide. The structure of the product was characterized by FT-IR (Fourier transform infrared) spectroscopy and elemental analysis. The oxidation of benzyl alcohol by $C_9H_7NHCrO_3Cl$ in various solvents showed that the reactivity increased with increasing dielectric constant(${\varepsilon}$) in the following order: DMF (N,N'-dimethylformamide) > acetone > chloroform > cyclohexane. The oxidation of alcohols was examined by $C_9H_7NHCrO_3Cl$ in DMF. As a result, $C_9H_7NHCrO_3Cl$ was found to be an efficient oxidizing agent that converts benzyl alcohol, allyl alcohol, primary alcohols, and secondary alcohols to the corresponding aldehydes or ketones (75%-95%). The selective oxidation of alcohols was also examined by $C_9H_7NHCrO_3Cl$ in DMF. $C_9H_7NHCrO_3Cl$ was the selective oxidizing agent of benzyl, allyl and primary alcohol in the presence of secondary ones. In the presence of DMF with an acidic catalyst, such as $H_2SO_4$, $C_9H_7NHCrO_3Cl$ oxidized benzyl alcohol (H) and its derivatives ($p-OCH_3$, $m-CH_3$, $m-OCH_3$, m-Cl, and $m-NO_2$). Electron donating substituents accelerated the reaction rate, whereas electron acceptor groups retarded the reaction rate. The Hammett reaction constant (${\rho}$) was -0.69 (308K). The observed experimental data were used to rationalize hydride ion transfer in the rate-determining step.

Effect of various abutment systems on the removal torque and the abutment settling in the conical connection implant systems (원추형 연결 임플란트에서 지대주 종류에 따른 나사풀림과 침하현상에 관한 연구)

  • Lee, Jin-Seon;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.92-98
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the effects of different abutment materials on abutment screw loosening and settling-down effect in conical connection type implant system. Materials and methods: Three types of abutment, cementation, gold UCLA, and metal UCLA abutment were used. Two UCLA groups were fabricated in a similar pattern to cementation abutment. Type III gold alloy and Nickel-Chromium alloy was used for casting gold UCLA abutment and metal UCLA abutment, respectively. Fixture and abutment were tightened to 30 Ncm by using digital torque controller and re-tightening was conducted with same force after 10 minutes. Digital torque gauge was used to measure loosening torque and fixture/abutment length was measured by digital micrometer. Dynamic loads between 25 N and 250 N were applied with $0^{\circ}$ angle to the abutment axis. After loading, fixture/abutment length was re-measured and amount of settlement was calculated. Loosening torque value was also measured for comparison Results: All three groups showed significant differences of length when comparing before and after loading, but there was no significant difference of settling amount in all groups. Loosening torque values were significantly decreased when comparing before and after loading in all groups($P$<.05). However, there was no significant difference in loss of loosening torque values when compared to groups. Conclusion: In internal conical connection type implants, dynamic load affected on settlement and loosening torque of implant, but there was no differences between abutments materials. Likewise gold UCLA abutment, metal UCLA abutment might be able to withstand functional load.