• Title/Summary/Keyword: Chrome(Cr)

Search Result 101, Processing Time 0.031 seconds

Web browser secureness with respect to CVSS

  • Joh, HyunChul
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.11a
    • /
    • pp.464-465
    • /
    • 2014
  • Analysis of characteristics in software vulnerabilities can be used to assess security risks and to determine the resources needed to develop patches quickly to handle vulnerability discovered. Being a new research area, the quantitative aspects of software vulnerabilities and risk assessments have not been fully investigated. However, further detailed studies are required related to the security risk assessment, using rigorous analysis of actual data which can assist decision makers to maximize the returns on their security related efforts. In this paper, quantitative software vulnerability analysis has been presented for major Web browsers (Internet Explorer (IE), Firefox (FX), Chrome (CR) and Safari (SF)) with respect to the Common Vulnerability Scoring System (CVSS). The results show that, almost all the time, vulnerabilities are compromised from remote networks with no authentication required systems, and exploitation aftermath is getting worse.

Topographic Variations of the Seasonal Skin Color -A Study for the Map of the Skin Color 1- (피부색의 계절에 따른 부위별 차이와 특성 -피부색 지도 설계를 위한 연구 I-)

  • Park Myung-Hee;Kim Kyung-Soon
    • Journal of the Korean Society of Costume
    • /
    • v.54 no.7
    • /
    • pp.79-90
    • /
    • 2004
  • In this study we tried to find the skin color of Koreans according to the change of seasons, and to the degree of make-up used by men and women. in order to furnish foundation data that could be used in the cosmetics and clothes industries. The skin color was measured with Minolta's Chrome Meter CR-200 in seven parts of the body with Munsell's hue, value, chroma. The difference in skin color in men and women's groups, and the difference in skin color of each group in March and in September were treated with SPSS's Anova and t-test. 1. In both seasons. March and September, a big difference could be observed between the two groups (men and women's). The body was more yellowish than the face. The men's group had a reddish skin color than the women's groups. In all groups we could observe a big difference in color between seasons, and in March, the skin was more reddish whereas in September, it became more yellowish. 2. As for the value, both in March and in September, the hairline was darkest, and the lightest areas were the jaw and the inner arm which showed a similar value. The group of women who put on make-up had the highest value, whereas the men's group showed the lowest result in value. We suppose it to be due to the fact that Putting on make-up prevented the melanin pigmentation by blocking the UV rays. 3. We could observe the highest value in chrome in the chin area both in March and in September, and there was no significant change. There was a difference in men and women's groups, but not a significant one within the women's groups.

Wear behaviors of HVOF spray coating of Co-alloy T800

  • Cho, Tong-Yul;Yoon, Jae-Hong;Kim, Kil-Su;Park, Bong-Kyu;Youn, Suk-Jo;Back, Nam-Ki;Chun, Hui-Gon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.16 no.3
    • /
    • pp.121-126
    • /
    • 2006
  • HVOF thermal spray coating of Co-alloy T800 is progressively replacing the classical hard coatings such as chrome plating because of the very toxic $Cr^{6+}$ ion known as carcinogen causing lung cancer. For the study of the possibility of replacing of chrome plating, the wear properties of HVOF Co-alloy T800 coatings are investigated using the reciprocating sliding tester both at room and at an elevated temperature of $1000^{\circ}F\;(538^{\circ}C)$. The possibility as durability improvement coating is studied for the application to the high speed spindles vulnerable to frictional heat and wear. Wear mechanisms at the reciprocating sliding wear test are studied for the application to the systems similar to the sliding test such as high speed spindles. Wear debris and frictional coefficients of T800 coatings both at room and at an elevated temperature of $1000^{\circ}F\;(538^{\circ}C)$ are drastically reduced compared to those of non-coated surface of parent substrate Inconel 718. This study shows that the coating is recommendable for the durability improvement coatings on the surfaces vulnerable to frictional heat. The sliding surfaces are weared by the mixed mechanisms such as oxidative wear, abrasion by the sliding ball slurry erosion by the mixture of solid particles and small drops of the melts and semi-melts of the attrited particles cavitation by the relative motions among the coating, sliding ball, the melts and semi-melts. and corrosive wear. The oxide particles and the melts and semi-melts play roles as solid and liquid lubricant reducing the wear and friction coefficient.

A Study on the Variation of Tensile Strength and Hardness According to the Frequency of Reuse with Chrome-Cobalt Alloy Widely used in the Production of Partial Denture (국부의치 제작에 사용되는 Chrome Cobalt Alloy의 재주조 횟수에 따른 인장강도 및 경도 변화에 대한 실험적 연구)

  • Chung, Kyung-Pung
    • Journal of Technologic Dentistry
    • /
    • v.18 no.1
    • /
    • pp.15-25
    • /
    • 1996
  • This study is to measure and compare the hardness and tensile strength of each time after we recast seven times continually only with and metal alloy Chromium-Cobalt alloy used in the production of partial denture frame work. The result of the experiment were as follow; 1) The result of the hardness measurement The result of the first casting was $490.48{\pm}38.38$ and that of the second recasting was $455.18{\pm}35.61$ and form the third recasting. the result were $518.38{\pm}37.68$ and over. The change of the hardness difference between each recasting was as follow; The hardness difference between the first casting and the second recasting was $35.25{\pm}31.93$ and that between the second recasting and the third recasting was $63.20{\pm}54.02$. There was a statistically significant difference(P<0.01) in the above hardness, however, there was little difference on the whole. And after the third recasting, the hardness grew high a little bit. That is why low-melting metals such as Cr, Mn, Cu of alloy ingredient was evaporated or there was an effect of changes in metal crystal structure, I suppose. 2) The result of the tensile strength measurement. There was a statistically significant difference(P<0.01) between the first casting and the second, the fourth recasting, however. there was little difference in general.

  • PDF

The properties and wear behavior of HVOF spray coating layer of Co-alloy powder

  • Cho, Tong-Yul;Yoon, Jae-Hong;Kim, Kil-Su;Youn, Suk-Jo;Back, Nam-Ki;Chun, Hui-Gon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.16 no.6
    • /
    • pp.273-277
    • /
    • 2006
  • High velocity of oxy-fuel (HVOF) thermal spray coating is progressively replacing the other classical hard coatings such as chrome plating and ceramic coating by the classical methods, since the very toxic $Cr^{6+}$ ion is well known as carcinogen causing lung cancer, and the ceramic coatings are brittle. Co-alloy T800 powder is coated on the Inconel 718 substrates by the HVOF coating procesess developed by this laboratory. For the study of the possibility of replacing of chrome plating, the wear properties of HVOF Co-alloy T800 coatings are investigated using the reciprocating sliding tester with a counter sliding SUS 304 ball both at room and at an elevated temperature of $1000^{\circ}F\;(538^{\circ}C)$. The possibility as durability improvement coating is studied for the application to the high speed spindles vulnerable to frictional heat and wear. Wear mechanisms at the reciprocating sliding wear test are studied far the application to the systems similar to the sliding test such as high speed spindles. Wear debris and frictional coefficients of T800 coatings both at room and at an elevated temperature of $538^{\circ}C$ are drastically reduced compared to those of non-coated surface of Inconel 718 substrates. Wear traces and friction coefficients of both coated and non-coated surfaces are drastically reduced at a high temperature of $538^{\circ}C$ compared with those at room temperature. These show that the coating is highly recommendable far the durability Improvement coating on the surfaces vulnerable to frictional heat and wear.

Wear Property of HVOF WC-CoCr Coating Manufactured by Optimal Coating Process (최적 고속화염용사코팅 공정기술에 의하여 제조된 WC-CoCr 코팅의 마모 특성)

  • Song, Ki O;Cho, Tong Yul;Yoon, Jae Hong;Fang, W.;Youn, Seok Jo;Youn, Kuk Tae;Suh, Chang Hee;Hwang, Soon Young;Ha, Sung Sik
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.6
    • /
    • pp.351-356
    • /
    • 2008
  • Thermally sprayed tungsten carbide-based powder coatings are being widely used for a variety of wear resistance applications. The coating deposited by high velocity processes such as high velocity oxy-fuel (HVOF) thermal spraying is known to provide improved wear resistant property. In this study, optimal coating process (OCP) is obtained by the study of coating properties such as surface hardness, porosity, surface roughness and microstructure of 9 coatings prepared by Taguchi program for 3 levels of four spray parameters. The Friction and wear behaviors of HVOF WC-CoCr coating prepared by OCP, electrolytic hard chrome (EHC) plating and Inconel718 (In718) are investigated by reciprocating sliding wear test at $25^{\circ}C$, $450^{\circ}C$. Friction coefficients (FC) of all of the 3 samples are decreased as increasing sliding surface temperature from $25^{\circ}C$ to $450^{\circ}C$. FC of WC-CoCr decreases as increasing the surface temperature from $0.33{\pm}0.02$ at $25^{\circ}C$ to $0.26{\pm}0.02$ at $450^{\circ}C$, showing the lowest FC among the 3 samples. Wear trace (WT) and wear depth (WD) of WC-CoCr are smaller than those of EHC and In718 both at $25^{\circ}C$ and $450^{\circ}C$. These show that WC-CoCr is highly recommendable for protective coating on In718 and other metal components.

Taxonomic Study of the Genus Lespedeza by Means for Colour Reactions (정색반응(呈色反應)에 의(依)한 싸리속(屬)의 분류학적(分類學的) 연구(硏究))

  • Park, Chong Yawl;Lee, Tchang Bok
    • Journal of Korean Society of Forest Science
    • /
    • v.14 no.1
    • /
    • pp.21-31
    • /
    • 1972
  • It has intended to identify the members of the Genus Lespedeza in Korea by a chemical colour reaction, and the following five species of the Genus Lespedeza grown in the garden have been used in this experiment. 1. Lespedeza bicolor Turcz 2. Lespedeza bicolor var. melanantha (Nak.) T. Lee 3. Lespedeza cyrtobotrya Miq. 4. Lespedeza japonica var. intermedia Nakai 5. Lespedeza maritima Nakai 6. Lespedeza maximowiczii Schneider 7. Lespedeza maximowiczii var. tomentella Nakai A few drops of each solution of $K_2Cr_2O_7$. $FeSO_4{\cdot}7H_2O$, $FeCl_3$, $KH_2PO_4$, $KMnO_4$, $NH_4OH$, and HCl was added to the methanol extracts of wood dust to get the specific colour reaction. HCl-infused wood was also used for the identification of L. bicolor var. melanantha and L. bicolor. The results can be summarized as the following key; 1. Chrome lemon by $K_2Cr_2O_7$ ${\cdots}{\cdots}$2 1. Sun flower yellow by $K_2Cr_2O_7$ ${\cdots}{\cdots}$Lespedeza maximowiczii var. tomentella Nakai 2. $KH_2PO_4$ Oystem white by $KH_2PO_4$; golden yellow by $FeCl_3$ ${\cdots}{\cdots}$=3 2. Cream colour by $KH_2PO_4$=6 3. Oyster white by $NH_4OH$; corn colour by $FeSO_4{\cdot}7H_2O$ ${\cdots}{\cdots}$4 3. Cream colcur by $NH_4OH$ ${\cdots}{\cdots}$5 4. Van dyke brown by $KMnO_4$ ${\cdots}{\cdots}$; sea shell pink by HCl injection under heating ${\cdots}{\cdots}$Lespedeza japonica var. intermedia Nakai 4. Sepia colour by $KMnO_4$; honey colour by HCl injection under heating ${\cdots}{\cdots}$Lespedeza maritima Nakai 5. Golden red by $FeSO_4{\cdot}7H_2O$; andover green by HCl-infused wood dust ${\cdots}{\cdots}$Lespedeza bicolor var. melanantha (Nak.) T. Lee 5. Yellow ochre by $FeSO_4{\cdot}7H_2O$; sand warm gray by HCl-infused wood dust ${\cdots}{\cdots}$Lespedeza bicolor Turcz 6. Amber green by $FeCl_3$ ${\cdots}{\cdots}$Lespedeza cyrtobotrya Miq. 6. Leather brown by $FeCl_3$ ${\cdots}{\cdots}$Lespedeza maximowiczii Schneider.

  • PDF

The Effect of Titanium on the Castability of Cobalt-Chrome Alloy (코발트 크롬 합금의 주조성에 미치는 타이타늄의 효과)

  • Ryu, Su-Kyoung;Chung, Hee-Jeong;Vang, Mong-Sook;Yang, Hong-So;Lim, Hyun-Pil;Yun, Kwi-Dug;Park, Sang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.1
    • /
    • pp.73-79
    • /
    • 2011
  • Purpose of this experiment is to evaluate the effect of titanium on the castability when the titanium is added to the Co-Cr alloy. Raw materials Cobalt, Chrome, Molybdenum, Silicon, Manganase, Carbon, Nitrogen, Titanium were weighted and prepared. $Biosil^F$ (Degudent, Germany) was the control group. To the experimental group, different weight percent of titanium was added from 1 wt% to 4 wt%. The wax pattern is $30{\times}40$ cm in size, rectangular in shape and has total of 160 grids. Centrifugal machine (Neutrodyne Easy Ti: Manfredy) was used for casting. For evaluation of the castability, the number of complete grids was counted by visual inspection and X-ray inspection. The test showed similar castability with the control group in the titanium addition of 1 wt% to 3 wt%. The titanium addition of 4 wt% showed poor result. With titanium lower than 4 wt%, the experiment metals showed proper castability with high expectation of successful clinical use.

Conservation of Chungmugong's Artifacts (보물 제326호 이충무공유물의 과학적 보존)

  • Kwon, Hyuk Nam;Seo, Jung Eun;Ha, Eun Ha;Lee, Han Hyoung;Lee, Eun Woo
    • Korean Journal of Heritage: History & Science
    • /
    • v.44 no.3
    • /
    • pp.62-77
    • /
    • 2011
  • Yi Sunsin's artifacts had been exhibited at Hyeonchungsa in Asan-si, Chungchungnam-do. These artifacts include Janggeom(Long swords), Okno(Jade ornament of Korea traditional hat), Yodae(Waist belt) and Dobae(Peach shaped wine cups) Gudae(Yodae's saucers). These were covered with dust and corroded due to long term display. Condition of these artifacts was examined for a re-opening of Yi Chungmugong Memorial Pavilion on 28 March 2011. Before conservation treatment of the artifacts, scientific analysis was conducted to identify the material of the artifacts. The result showed that the red paint on the hilt of the sword is composed of two layers. Pigments of two layers were found to be hematite and cinnabar mixed with red lead respectively. Mixed layer was assumed to have been applied recently. Also it was found that the blade of the sword was repainted using chrome yellow($PbCrO_4$). Considering the time limit, conservation treatment focused on stabilization of damaged area and prevention of futher risk during display.

Contents of heavy metals in marine fishes, sold in Seoul (서울에 유통 중인 해산 어류의 부위별 중금속 분석)

  • Hwang, Yong Ok;Park, Seog Gee
    • Analytical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.342-351
    • /
    • 2006
  • This study was carried out to estimate the contents of heavy metals in big marine 17 kinds of fishes (n=89) which had been sold at wholesale market in Seoul from January to December in 2005. The contents of mercury (Hg), lead (Pb), cadmium (Cd), chrome (Cr), copper (Cu) and arsenic (As) were measured by the mercury analyzer and atomic spectrophotometer (AAS) in the flesh, liver, and gill part. The values of heavy metals in fishes were as follows ($Mean{\pm}SD$, mg/kg). The average contents of heavy metals in the fishes were Hg $0.08{\pm}0.01mg/kg$, Pb $0.17{\pm}0.32mg/kg$, Cd $0.34{\pm}0.07mg/kg$, Cr $0.05{\pm}0.05mg/kg$, Cu $1.14{\pm}0.13mg/kg$, As $0.24{\pm}0.22mg/kg$. Of the heavy metals detected in 3 parts, liver was measured highly in the all heavy metals. Of the heavy metals detected in countries, Hg, Pb, and Cu were measured highly in New Zealand, Cd and As in Norway, Cr in Korea. The range of heavy metal contents in imported and domestic fishes are low level, except of mercury contents of imported Yellow porgy (n=2), compared with regulation value of anther nations and Korea. And the contents of heavy metal in the imported fishes are natural. By correlation coefficients between fish livers of all subjects, a significant correlation was found Hg (r=0.989, p<0.01), Pb (r=0.978, p<0.01), Cd (r=0.991, p<0.01), Cu (r=0.998, p<0.01), As (r=0.198, p<0.05) in fish livers and flesh.