• Title/Summary/Keyword: Choi, In-hoon

Search Result 7,340, Processing Time 0.045 seconds

The Relationship between Opioids Use, Cortisol and DHEAS (마약성 진통제 사용과 Cortisol 및 DHEAS와의 관계)

  • Jung, Ji Hoon;Choi, Youn Seon;Kim, Seon Mee;Lee, June Young;Kim, Eun Hye;Kim, Jung Eun;Kim, E Yeon;Park, Hee Jin;Yoon, Dong Jin
    • Journal of Hospice and Palliative Care
    • /
    • v.18 no.2
    • /
    • pp.105-111
    • /
    • 2015
  • Purpose: Fatigue, energy loss, feeling of helplessness, poor appetite, pain besides general weakness are major symptoms presented to terminally ill cancer patients. These symptoms are similar to those that appeared with adrenal insufficiency. Also, for terminally ill cancer patients who are hospitalized for palliative care, opioid agents are prescribed to control moderate to severe pain. We studied the relationship of opioid agents and adrenal insufficiency. Methods: From November 2013 through June 2014, we monitored the serum level of cortisol and dehydroepiandrosterone sulfate (DHEAS, serum) in 55 cancer patients who were over 18 years old and were treated at a hospice center. We also checked the treatment period and dosage of opioid agents. Results: The DHEAS level, treatment period and dosage of opioid agents did not have significant correlation. Correlation between the serum cortisol level and the opioid agent treatment period was not significant either, but the serum cortisol level was positively correlated with the dosage of opioid agents (P value 0.0322). Conclusion: This study did not identify a novel link between treatment period, dosage of opioid agents and adrenal insufficiency. But, the DHEAS level was mostly below the normal level in patients who were treated with opioid agents.

Development of a Finger Tactile Stimulator Based on E-Prime Software (E-Prime에 기반한 손가락 촉각 자극기의 개발)

  • Kim, Hyung-Sik;Min, Yoon-Ki;Kim, Bo-Seong;Min, Byung-Chan;Yang, Jae-Woong;Lee, Su-Jeong;Choi, Mi-Hyun;Yi, Jeong-Han;Tack, Gye-Rae;Lee, Bong-Soo;Jun, Jae-Hoon;Chung, Soon-Cheol
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.703-710
    • /
    • 2010
  • In this study, a tactile stimulator was developed to resolve some problems from the previous version of the system such as system configuration, inappropriate stimulation control and additional problems. The developed tactile stimulator consists of control unit, drive unit and vibrator unit. The control unit was controlled by E-Prime software to generate appropriate vibration pulses. The drive unit supplies enough energy to the vibrator to generate effective stimulation pulses. The vibrator unit consists of small coin type vibrator and velcro, and was made to be attached at the hand easily. The developed tactile stimulator was designed by small-size, light-weight, low-power, simple-fabrication, max 35 channels and little delay time from instruction signal of E-Prime software to vibrator. The duration and magnitude of stimulation was controlled by 10 grades and the problems concerning stimulation control were compensated by wideband frequency ranges. Additionally, the electrical safety was ensured by low voltage operation. Vibrator was made to be attached on finger as well as on any part of the subject. Since this tactile stimulator is developed based on E-Prime software which is widely used in cognitive science, it is believed that this stimulator be suitable for the wide application of cognitive science study.

  • PDF

Comparison of Greenhouse Gas Emission from Liquid Swine Manure According to Aeration Levels in Summer (돈분뇨 액비의 폭기수준에 따른 여름철 온실가스 배출량 비교)

  • Choi, Dong-Yoon;Park, Kyu-Hyun;Cho, Sung-Back;Yang, Seong-Hak;Hwang, Ok-Hwa;Kwag, Jung-Hoon;Ahn, Hee-Kwon;Yoo, Yong-Hee
    • Journal of Animal Environmental Science
    • /
    • v.17 no.3
    • /
    • pp.163-170
    • /
    • 2011
  • This study was carried out to investigate greenhouse gas (GHG), $CH_4$ and $N_2O$, emission from liquid swine manure according to aeration levels in summer. To evaluate the influence of operation methods on GHG emissions, liquid swine manure were applied with different rates of aeration (store without aeration, $1m^3/ton/h$, $2.5m^3/ton/h$, and $5m^3/ton/h$). Following are the results of this study. The liquid swine manure applied no aeration, $1m^3/ton/h$, $2.5m^3/ton/h$, and $5m^3/ton/h$ aeration rates released 315.6, 13.9, 17.9 and $9.6{\mu}g/m^2/s$ of $CH_4$ and 0.173, 0.157, 0.131, and $0.241{\mu}g/m^2/s$ of $N_2O$, respectively. Liquid swine manure applied no aeration released the most amount of GHG ($6,681.4{\mu}g/m^2/s$ $CO_2$-Eq.) and followed by $5m^3/ton/h$ ($276.4{\mu}g/m^2/s$ $CO_2$-Eq.), $2.5m^3/ton/h$ ($416.0{\mu}g/m^2/s$ $CO_2$-Eq.), and $1m^3/ton/h$ ($340.8{\mu}g/m^2/s$ $CO_2$-Eq.). Our results reveal that the aerated system may reduce GHG emissions compared to no aeration. Consequently, aeration and mixing were effective at reducing GHG emissions during liquid swine manure storage.

Influence of Ca Reduction Process on the Properties of Nanocrystalline Nd-Fe-B Powders Prepared by a Thermochemical Process (열화학공정으로 제조된 나노결정형 Nd-Fe-B 분말의 특성에 미치는 Ca환원 공정의 영향)

  • Lee, Dae-Hoon;Jang, Tae-Suk;Yoo, J.-H.;Choi, C.-J.;Kim, B.-K.;Park, Byeong-Yeon
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.1
    • /
    • pp.42-47
    • /
    • 2005
  • Nanocrystalline Nd-Fe-B powder was synthesized by a new thermochemical process that combined with past reduction-diffusion process and spray-dry process. In this process, Ca reduction process is vary important due to formation of hard magnetic$Nd_{2}Fe_{14}B$ phase from various oxides by Ca powder. Therefore, the final products are essentially affected a shape, size, and composition etc. of the Ca reduced powders. Ca reduction was performed to way that raw powders just mixed with Ca powder in proper ratio unlike to compress into compact. The powders after mixture-type Ca reduction mainly composited with $Nd_{2}Fe_{14}B$ phase even relativily low reaction temperature ($800^{\circ}C$) and all particle size of powder were distributed less than 1 ${\mu}m$ except for powder after Ca oxides as magnetic properties of powders after cake-type Ca reduction, with the consequence that high magnetic properties has been expected. The magnetic properties of powders prepared by mixture-type Ca ruduction, with the conseqence that high magnatic properties has been expected. The magnetic properties of powders prepared by mixture-type Ca reduction process showed $_iH_c$ = 5.9 kOe, $B_r$ = 5.5 kG, (BH)max = $Nd_{2}Fe_{14}B{\to}Nd_{2}Fe_{17}B$ decomposition by violent exothermic reaction during washing.

The Design and Fabrication of Conversion Layer for Application of Direct-Detection Type Flat Panel Detector (직접 검출형 평판 검출기 적용을 위한 변환층 설계 및 제작)

  • Noh, Si-Cheol;Kang, Sang-Sik;Jung, Bong-Jae;Choi, Il-Hong;Cho, Chang-Hoon;Heo, Ye-Ji;Yoon, Ju-Seon;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.73-77
    • /
    • 2012
  • Recently, Interest to the photoconductor, which is used to flat form X-ray detector such as a-Se, $HgI_2$, PbO, CdTe, $PbI_2$ etc. is increasing. In this study, the film layer by using the photoconductive material with particle sedimentation was fabricated and evaluated. The quantization efficiency of the continuous X-ray with the 70 kVp energy bandwidth was analyzed by using the Monte Carlo simulation. With the results, the thickness of film with 64 % quantization efficiency was 180 ${\mu}m$ which is similar to the efficiency of 500 ${\mu}m$ a-Se film. And $HIg_2$ film has the high quantization efficiency of 74 % on 240 ${\mu}m$ thickness. The electrical characteristics of the 239 ${\mu}m$ $Hgl_2$ films produced by particle sedimentation were shown as very low dark current(under 10 $pA/mm^2$), and high sensitivity(19.8 mC/mR-sec) with 1 $V/{\mu}m$ input voltage. The SNR, which is influence to the contrast of X-ray image, was shown highly as 3,125 in low driving voltage on 0.8 $V/{\mu}m$. With the results of this study, the development of the low-cost, high-performance image detector with film could be possible by replacing the film produced by particle sedimentation instead to a-Se detector.

Microtensile bond strength of resin inlay bonded to dentin treated with various temporary filling materials (임시 가봉재가 상아질과 레진 인레이의 미세인장 결합 강도에 미치는 영향)

  • Kim, Tae-Woo;Lee, Bin-Na;Choi, Young-Jung;Yang, So-Young;Chang, Hoon-Sang;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.5
    • /
    • pp.419-424
    • /
    • 2011
  • Objectives: This study was aimed to determine the effects of temporary sealing materials on microtensile bond strength between resin-coated dentin and resin inlay and to compare the bonding effectiveness of delayed dentin sealing and that of immediate dentin sealing. Materials and Methods: The teeth were divided into 4 groups: group 1, specimens were prepared using delayed dentin sealing after temporary sealing with zinc oxide eugenol (ZOE); group 2, specimens were prepared using immediate dentin sealing and ZOE sealing; group 3, specimens were prepared using immediate dentin sealing and Dycal (Dentsply) sealing; group 4, specimens were prepared using immediately sealed, and then temporarily sealed with a resin-based temporary sealing material. After removing the temporary sealing material, we applied resin adhesive and light-cured. Then the resin inlays were applied and bonded to the cavity with a resin-based cement. The microtensile bond strength of the sectioned specimens were measured with a micro-tensile tester (Bisco Inc.). Significance between the specimen groups were tested by means of one-way ANOVA and multiple Duncan's test. Results: Group 1 showed the lowest bond strength, and group 4 showed the highest bond strength (p < 0.01). When temporary sealing was performed with ZOE, immediate dentin sealing showed a higher bonding strength than delayed dentin sealing (p < 0.01). Conclusions: Based on these results, immediate dentin sealing is more recommended than delayed dentin sealing in bonding a resin inlay to dentin. Also, resin-based temporary sealing materials have shown the best result.

THE COMPARATIVE STUDY FOR THE SHEAR BOND STRENGTH OF DENTAL ADHESIVES CURED WITH VARIOUS LIGHT SOURCES (다양한 광원으로 중합한 치과용 접착제의 전단강도에 관한 비교 연구)

  • Choi, Nam-Ki;Cho, Seong-Hoon;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.1
    • /
    • pp.33-41
    • /
    • 2011
  • The objective of this study was to compare the shear bond strengths of five dentin adhesive systems cured with three different light curing sources. Seventy five noncarious permanent teeth were collected and stored in an 0.1% thymol solution at room temperature after extraction. The tested adhesives were: Adper Scotchbond Multi-purpose Plus Adhesive (SM) Adper Single bond 2 (SB), Clearfil SE Bond (SE), Adper Prompt L-Pop (PL), G-Bond (GB). And three light curing unit systems were used: Elipar Free light 2(LED), OptiLux 501 (Halogen), Flipo (PAC). For the shear bonding test, the labial and lingual surfaces of permanent teeth were used. To obtain a flat dentin surface, the labial and lingual surfaces of the teeth were sanded on SiO2 with number 600 grit and then divided into 15 groups of 10 surfaces each. All samples were theromocycled in water $5^{\circ}C$ and $55^{\circ}C$ for 1000 cycles. The results were as follows: 1. When cured with Freelight 2, the shear bond strength of SM was significantly higher than that of PL, GB (p<0.05), whereas no significant difference was found among those of any other bonding agents. 2. When cured with Optilux 501, the shear bond strength of SM was significantly higher than those of any other bonding agents (p<0.05), whereas no singnificant difference was found among those of andy other bonding agents. 3. When cured with Flipo, the shear bond strength of SM was significantly higher than those of SB, SE, GB (p<0.05), whereas no significant differences was found among those of any other bonding agents. 4. For comparison according to three different light cure unit system, except SB and GB, each three dentin bonding agents showed no significant difference. For SB, only Freelight 2 was significantly higher than the others, with no significant difference between Optilux 501 and Flip. For GB, Statistically significant difference was found only between Freelight and Flipo.

Study on Tree Growth and Soil Environment Relations of Sudokwon Landfill (수도권매립지수목생육과토양환경의관계연구)

  • Kang, Seong-Chil;Han, Bong-Ho;Choi, Jin-Woo;Jang, Jae-Hoon;Kim, Hong-Soon
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.3
    • /
    • pp.431-440
    • /
    • 2015
  • This study investigated the correlation between the trees planted on the slope of the first landfill where the landfill was completed and the soil environment. 69 plots (($7{\sim}20m{\times}5{\sim}20m$) were planted with 26 kinds of major trees in the first landfill slopes for vegetation survey. The survey was conducted from 2007 to 2009. Soil analysis from 2007 to 2008 was made on the basis of the injured index and the indicator species were selected. Depending on the rate of growth of the indicator species, seven survey locations were selected for soil sample analysis. 10 tree species appeared to adapt to the landfill environment. Among them, the coniferous trees were Pinus thunbergii (Seedling) and Juniperus chinensis and the deciduous trees were Quercus aliena, Salix preudo-lasiogyne, Castanea crenata (Seedling), Prunus armeniaca var. ansu, Quercus acutissima, Chionanthus retusus, Liriodendron tulipifera (Seedling) and Celtis sinensis. 8 species of trees did not adapt well to the landfill environment. Among them, two kinds were coniferous, the other six kinds were deciduous. In addition, judgment on the other 8 species of trees as to whether they adapted well or not was postponed. The species for which judgment was postponed included one coniferous tree and seven deciduous trees. Indicator species of injured index was the species that have more than 25 % of the defect. The soil was collected from where Catalpa ovata, Sophora japonica, Albizzia julibrissin and Acer palmatum were planted for analysis. According to the soil analysis, the soil pH showed that the soil was alkaline. Regarding the three phases of the soil, most sample soil showed 60 % for the solid phase or 55 % for the solid phase but with less than 10 % of gas phase. The organic matter content was found to be 0.14 to 2.52 %.

Commissionning of Dynamic Wedge Field Using Conventional Dosimetric Tools (선량 중첩 방식을 이용한 동적 배기 조사면의 특성 연구)

  • Yi Byong Yong;Nha Sang Kyun;Choi Eun Kyung;Kim Jong Hoon;Chang Hyesook;Kim Mi Hwa
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.71-78
    • /
    • 1997
  • Purpose : To collect beam data for dynamic wedge fields using conventional measurement tools without the multi-detector system, such as the linear diode detectors or ionization chambers. Materials and Methods : The accelerator CL 2100 C/D has two photon energies of 6MV and 15MV with dynamic wedge an91es of 15o, 30o, 45o and 60o. Wedge transmission factors, percentage depth doses(PDD's) and dose Profiles were measured. The measurements for wedge transmission factors are performed for field sizes ranging from $4\times4cm^2\;to\;20\times20cm^2$ in 1-2cm steps. Various rectangular field sizes are also measured for each photon energy of 6MV and 15MV, with the combination of each dynamic wedge angle of 15o 30o. 45o and 60o. These factors are compared to the calculated wedge factors using STT(Segmented Treatment Table) value. PDD's are measured with the film and the chamber in water Phantom for fixed square field. Converting parameters for film data to chamber data could be obtained from this procedure. The PDD's for dynamic wedged fields could be obtained from film dosimetry by using the converting parameters without using ionization chamber. Dose profiles are obtained from interpolation and STT weighted superposition of data through selected asymmetric static field measurement using ionization chamber. Results : The measured values of wedge transmission factors show good agreement to the calculated values The wedge factors of rectangular fields for constant V-field were equal to those of square fields The differences between open fields' PDDs and those from dynamic fields are insignificant. Dose profiles from superposition method showed acceptable range of accuracy(maximum 2% error) when we compare to those from film dosimetry. Conclusion : The results from this superposition method showed that commissionning of dynamic wedge could be done with conventional dosimetric tools such as Point detector system and film dosimetry winthin maximum 2% error range of accuracy.

  • PDF

Effect of moisture content on terminal velocities of domestic wheat and foreign materials (함수율에 따른 우리밀과 이물의 종말속도에 미치는 영향)

  • Choi, Eun-Jung;Kim, Hoon;Kim, Sang-Suk;Kim, Oui-Woung
    • Food Science and Preservation
    • /
    • v.23 no.5
    • /
    • pp.746-752
    • /
    • 2016
  • This research was carried out to identify aerodynamic property as a function of moisture content for designing equipment such as for post-harvest management. Terminal velocity of two wheat varieties {Backjjung (B) and Jogyeong (J)} with selected sound, damaged kernel and foreign materials (Wheat stick, Wheat husks) were measured with a designed vertical wind column at different moisture contents from about 9 to 30% wet basis. The results showed that terminal velocity of wheat and foreign materials except of Jogyeong's husks (p<0.05) had a significant difference at p<0.001. With increasing moisture content, the aerodynamic property values of the kernels and foreign materials of the two wheat varieties increased linearly. In detail, terminal velocity of sound and damaged kernel increased from 5.46 to 7.13 m/sec (B) and 7.48 to 8.60 m/sec (J), damaged kernel from 5.91 to 7.00 m/sec (B) and 6.48 to 7.75 m/sec (J). For foreign materials the terminal velocity of wheat stick increased from 2.92 to 4.07 m/sec (B) and 3.74 to 5.22 m/sec (J) whereas that of husks from 1.07 to 1.85 m/sec (B) and 2.02 to 2.33 m/sec (J) each. For air separation of wheat and foreign materials, the air flow should be less than 5.22 m/sec due to the range (1.07~5.22 m/sec) of foreign materials in wheat.