• Title/Summary/Keyword: Chlorine Control

Search Result 230, Processing Time 0.025 seconds

Fabrication of YBa_2Cu_3O_{7-x}$ceramic using the Sol-Gel process (졸-겔 법으로 YBa_2Cu_3O_{7-x}$세라믹의 제조)

  • Kim, Hyun-Taek;Kang, Hyung-Boo;Kim, Bong-Heup
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.299-301
    • /
    • 1989
  • This study presents a method of preparing $YBa_2Cu_3O_{7-x}$ ceramic and chlorine doping in it for the purpose of Jc enhancement us ins sol-gel process.Tetramethylammonium-hydroxide and pottasium carbonate solution were added to the aqueous solution of Yttrium nitrate, Barium chloride and Copper nitrate for pH control as well as forming hydroxy-carbonate precipitation. Instead of Barium nitrate, Barium chloride was used for doping chloride impurities in the specimen. The resulted materal showed good high Tc-superconductivity after calcination. Tc and Jc value are 92 K and 120.8 $A/cm^2$ respectively.

  • PDF

Study on Water Treatment Improvement Measures based on Case Studies of Ozone Disinfection at Domestic Water Treatment Plants (국내 정수장의 오존 소독능 평가사례를 통한 정수처리기준 개선방안 연구)

  • Noh, Hee-Su;Lee, Kyung-Hyuk;Wang, Chang-Keun;Son, Dae-Ik;Kang, Joon-Wun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.153-160
    • /
    • 2011
  • Ozone process is currently applied in 24 water treatment plants in Korea to control micropollutants and taste & odor compounds. However, one of the chlorine resistant protozoa, cryptosporidium, is not being considered as ozone disinfection performance whereas U.S. is already regulate Cryptosporidium by ozone disinfection. two ozone plants(PH, UH WTP) operation conditions are investigated for disinfection performance comparing Korea disinfection regulation and U.S. regulation. The ozone plants are unable to get Cryptosporidium inactivation credits by Korea disinfection regulation. However, the inactivation credit for Cryptosporidum was increased when the U.S. disinfection regulation was applied. The Korea disinfection credit regulation need revision to practical aspects.

Experimental Study for the Identification of the Nascent Product of OH Heterogeneous Reaction with NaCl using Chemical Ionization Mass Spectrometry

  • Park, Jong-Ho;Ivanov, Andrey V.;Molina, Mario J.
    • Mass Spectrometry Letters
    • /
    • v.3 no.4
    • /
    • pp.108-111
    • /
    • 2012
  • An experimental study on the nascent product of the OH heterogeneous reaction with NaCl was performed under dry and wet conditions using a bead-filled flow tube system coupled to a high-pressure chemical ionization mass spectrometer. The ozone concentration in the flow tube for the atomic hydrogen removal was varied in order to control the conversion reaction of molecular chlorine into HCl for the identification of the nascent product. The mass spectrometric observation was that the $O_3$ introduction reduced the concentration HCl, while it increased the concentration of $Cl_2$ and ClO. Based on the experimental results, we suggest that the nascent product of the titled reaction is gaseous $Cl_2$, which is followed by fast conversion into HCl in presence of H. No significant difference in the concentration profile between under dry and wet (RH = 2%) conditions was observed.

Evaluation of Chloride Ion Binding Capacity of Hardened Portland Cement Paste Containing Hydrotalcite (경화된 하이드로탈사이트 혼입 포틀랜드 시멘트 페이스트의 염소이온 고정능력 평가)

  • Han, Jae-Do;Lee, Yun-Su;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.27-28
    • /
    • 2018
  • Deterioration of reinforced concrete structures due to salt corrosion is a phenomenon that can be easily seen, and the main reason for deterioration is chloride ion. Therefore, researches are actively conducted to control chlorine ion penetration worldwide. The purpose of this study is to evaluate the chloride ion fixation capacity of Portland cement paste containing Hydrotalcite. For this purpose, cement paste containing 0%, 2.5%, and 5% of Hydrotalcite was sealed and cured for 28 days, and the cured cement paste was crushed. Chloride ion solution was prepared at a concentration of 0.5M using NaCl, and the powdered cement paste was reacted for a specific time in aqueous chloride ion solution. After the reaction, the concentration of the chloride ion aqueous solution was measured using a silver nitrate potentiometric titrator, and the reacted cement paste was analyzed using XRD and FT-IR.

  • PDF

Effect of Calcium Treatments on Storage Quality of Salted Chinese Cabbage (절임배추의 품질 유지에 미치는 칼슘제제의 효과)

  • 고하영;최동성
    • Food Science and Preservation
    • /
    • v.3 no.1
    • /
    • pp.1-5
    • /
    • 1996
  • Salted Chinese cabbage were dipped in solutions of CaCl2 (0.1%, 0.5%, 1.0%), Ca-lactate (0.5%) alone, or with chlorine (NaOCl 200ppm) and stored at 3 or 23$^{\circ}C$ to determine the effects of calcium (Ca) on storage quality. pH change and microbial growth of salted cabbage were reduced in CaCl2 of 0.1% and 1.0% more than in the water-dipped control but better than in NaOCl treatment at two temperatures. Storage quality of salted cabvage was not affected by Ca contents or Ca with Cl treatment.

  • PDF

Effects of pH, Alkalinity, Chloride Ion on the Copper Pipe Corrosion (동관에서 pH, 알칼리도, 염소이온이 부식에 미치는 영향)

  • Jo, Kwan-Hyung;Kim, Sun-Il;Woo, Dal-Sik
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.1 s.94
    • /
    • pp.43-48
    • /
    • 2007
  • This study investigated the effects of pH, alkalinity, and chlorine ion which are important water quality impact factors to the corrosion in the simulated distribution system where the copper pipe is affixed. The result shows that pitting index was increased as the alkalinity and chloride ion increase in the distilled water, but there was no relation to pH. Actually the uniform corrosion rate was decreased as the pH increase with the laboratory tap water. In conclusion, it is necessary to control the pH which stands above minimum 7.5 to prevent pitting corrosion in the copper pipe. Consequently, comprehensive research about the effect of lime soda($Ca(OH)_2$) which was used as a coagulation additive in the water treatment plant to pipe corrosion must be accomplished additionally.

Interfacial Properties of a-Se Thick Films to Solve Charge Trap and Injection Problems (전하 트랩 및 주입 문제를 해결하기 위한 비정질 셀레늄 필름의 계면 특성)

  • 조진욱;최장용;박창희;김재형;이형원;남상희;서대식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.497-500
    • /
    • 2001
  • Due to their better photosensitivity in X-ray, the amorphous selenium based photoreceptor is widely used on the X-ray conversion materials. It was possible to control the charge carrier transport of amorphous selenium by suitably alloying a-Se with other elements(e,g. As, Cl). The charge transport properties of amorphous Selenium is decided on hole which is induced from metal to selenium in metal-selenium junction and which is transferred in a-Se bulk. This phenomenon is resulted of changing electric field owing to increasing of space charge by deep trap of a-Se bulk. In this paper, We dopped the chlorine to compensate deep hole trap and deposited blocking layer using dielectric material to prevent from increasing space charge for injection charge between metal electrode and a-Se layer. We compared space charge and the decreasing of trap density through measuring dark and photo current.

  • PDF

Effect of Feed Monochloramination on Performance of RO Membranes (NH2Cl 사용으로 인한 RO 막의 성능 향상)

  • Hong, Seungkwan;Reiss, Robert;Taylor, James S.;Beverly, Sharon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.312-317
    • /
    • 2005
  • The 15 month pilot study was performed to investigate the effect of pretreatment by monochloramine ($NH_2Cl$) on the performance of RO membranes made of cellulose acetate (CA) and polyamide (PA). Both RO membranes experienced severe biological fouling without any pretreatment during the treatment of highly organic surface water in Florida, USA. Feed monochloramination at 5 mg/L significantly minimized productivity loss by effective control of biofouling. The CA membrane did not show any structural damages by monochloramine, while the PA membrane suffered from a gradual loss of membrane integrity by chlorine oxidation, which was characterized as an increase in productivity and a decrease in selectivity. The degradation of PA membrane increased with increasing monochloramine dose.

Control of Soybean Sprout Rot Caused by Pythium deliense in Recirculated Production System

  • Yun, Sung-Chul
    • The Plant Pathology Journal
    • /
    • v.19 no.6
    • /
    • pp.280-283
    • /
    • 2003
  • A soybean-sprout rot epidemic occurred in a mass production soybean sprout factory in 2000 and 2001 in Korea, which caused up to 20% production loss. Among the causal pathogenic bacteria and fungi, Pythium deliense was found to be the dominant pathogen of severe root and hypocotyls rot, particularly in recirculating water system. An average of 90% of the isolated fungi from the rotted sprout on potato dextrose agar were Pythium sp. The fungal density of Pythium in the sampled water was monitored in the recycled water system for 1 year using a selective medium (com meal agar with Pimaricin, 10 mg; Rifampicin, 10 mg; and Ampicillin, 100 mg per 1 liter). The drained water from the soybean-sprout cultivation always had a certain amount of fungus in it. The removal of Pythium from the recycling water system must be thorough, safe, and environment friendly. However, the pathogen in the water was easily found even after ozone and chlorine treatments, which were devised on the recycling system for the removal of microorganisms. 5-$\mu\textrm{m}$ pore size filter was applied and was able to successfully control the disease. As the sprout industry increasingly shifts into mass production, the demand for water will increase continuously. Recycling water for sprout production is eco-friendly. However, a process must be devised to be able to first decompose organic matters before Pythium zoospores are filtered.

Water Quality Alteration during Passing through Small Water Tank and Improvement of Tap Water Quality by Direct Connection Service (옥상물탱크 경유에 따른 수돗물 수질 변화 및 직결급수방식 도입에 의한 수질개선 효과 연구)

  • Lee, Mok-Young;Chang, Hyun-Jung;Lee, Eu-Kwang;Oh, Se-Jong;Lee, Chae-Keun;Lee, Hyun-Dong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.4
    • /
    • pp.328-336
    • /
    • 2000
  • In order to compare the effect of water quality on two service systems, tank and direct connection service, we selected randomly 30 rooftop tanks installed in the buildings with five or fewer floors, and collected water samples from each tank as well as tap water by direct service. At the same time each tank was investigated on their cleanliness and sanitary control. 30 water samples from direct service met Korean Drinking water quality standard. But 5 tank water samples(17%) were not able to meet Coliform or Total Colony Counts standard and free chlorine of 12 tank water samples(40%) were less than 0.2mg/L. Also Fe, Turbidity, TOC, Total Algae in tank water were higher than tap water on direct service. We concluded that thorough health control of water tank is necessary and conversion into direct connection service results in improving tap water quality importantly.

  • PDF