항만 콘크리트 구조물의 현장환경변화에 따른 염소이온 침투해석 (Analysis of Chloride Ion Penetration for Harbor Concrete Structure with In-situation Environment)

  • 한상훈;장인성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.225-228
    • /
    • 2004
  • In order to estimate the chloride ion penetration, the model, which considers diffusion and sorption, is proposed on the basis of Finite Element Method (FEM). The FEM program provides the estimation of chloride concentration according to cyclic humidity and sorption. After the humidity diffusion analysis is carried out, the chloride ion diffusion and sorption analysis are conducted on the basis of the preestimated humidity data in each element. Each element has different analysis variables at different ages and locations. At early ages and constant outer humidity, the difference between inner and outer relative humidity causes the chloride ion penetration by sorption. As the humidity diffusion reduces the difference with age, the effect of sorption on the chloride ion penetration decreases. By the way, the cyclic humidity increases the effect of sorption on the chloride ion penetration at early ages, and the quantity of chloride ion around steel at later ages. Therefore, the in-situ analysis of chloride ion penetration for marine concrete structures must be performed considering the cyclic humidity condition and the long term sorption.

  • PDF

RC구조물 염해 내구성 설계 평가 프로그램 문헌 비교연구 (A Study on the Comparative Analysis of Chloride Penetration Durability Design Program of Reinforced Concrete Structures.)

  • 이형민;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.259-260
    • /
    • 2012
  • As RC structures in the marine environment rapidly increase, the interest and the importance of Chloride Penetration durable design have been growing. However, there is hardly any domestic Chloride Penetration durability of RC structures designed analysis programs. Currently, Chloride Penetration durable design method is studied and launched actively as a program in the United States, Europe, Japan and etc., but it is limited to Chloride Penetration durability of RC structures excluded from maintenance construction. Also, the level of dependence on the foreign technology is high; the foreign program is imported and used when needed. The main objective is to compare and to evaluate with the durability assessment program and several conditions when considering the design of Chloride Penetration durability through the programs developed abroad.

  • PDF

건습이 반복되는 환경하의 해양콘크리트 구조물에 대한 염소이온 침투 해석 (Analysis of Chloride Ion Penetraion for Marine Concrete Structure with Cyclic Humidity Environment)

  • 한상훈
    • Ocean and Polar Research
    • /
    • 제26권1호
    • /
    • pp.43-50
    • /
    • 2004
  • The diffusion model, which considers diffusion and sorption, is proposed. The FEM program developed on the basis of the diffusion model provides the estimation of chloride concentration according to cyclic humidity and sorption. After the humidity diffusion analysis is carried out, the chloride ion diffusion and sorption analysis are conducted on the basis of the preestimated humidity data in each element. Each element has different analysis variables at different ages and locations. At early ages, the difference between inner and outer relative humidity causes the chloride ion penetration by sorption. As the humidity diffusion reduces the difference with age, the effect of sorption on the chloride ion penetration decreases. By the way, the cyclic humidity increases the effect of sorption on the chloride ion penetration at early ages, and the quantity of chloride ion around steel at later ages. Therefore, the in situ analysis of chloride ion penetration for marine concrete structures must be performed considering the cyclic humidity condition and the long term sorption.

염분 농도에 따른 콘크리트 구조물의 염분침투 해석 (Chloride Penetration Analysis of Concrete Structures with Chloride Concentration)

  • 양주경
    • 한국컴퓨터산업학회논문지
    • /
    • 제9권3호
    • /
    • pp.137-142
    • /
    • 2008
  • 염소이온 침투로 인해 철근 부식에 가장 큰 영향을 끼치는 인자는 염소이온 표면농도이다. 본 연구에서는 염소이온 표면농도에 따른 염해 진행 정도를 개발한 프로그램을 통하여 해석적으로 접근하였다. 또한 해석 프로그램을 통하여 염소이온 표면농도에 따른 내구수명을 산정하였다. 염소이온 표면농도가 600ppm인 경우도 염소이온 침투 깊이가 32.3mm 정도로 나타났다. 콘크리트의 피복두께를 40mm를 유지한다면 염소이온 표면농도가 600ppm일 때 콘크리트의 내구수명은 167년으로 검토되었다.

  • PDF

온도.습도분포 및 혼화재를 고려한 염분침투에 관한 연구 (A Study About Chloride Penetration Considering Temperature, Humidity Distribution and Admixtures)

  • 최종권;김기현;차수원;장승엽;장승필
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.553-556
    • /
    • 2006
  • Chloride penetration is the main reason which causes the deterioration of concrete structures. Chloride penetration of concrete structures due to chemical-physical phenomena can be profitably analyzed by means of model-based simulations. The main purpose of this paper is to analyze chloride penetration considering self-desiccation, convection and admixture(GBFS: granulated blast-furnace slag) effects. Basic governing equations are modified properly to apply these effects to chloride penetration analysis. Temperature and relative humidity data of In-Cheon from Korea Meteorological Administration are used for analyzing chloride penetration.

  • PDF

해양 콘크리트 구조물의 염소이온 침투해석 (Analysis of Chloride ion Penetration of Marine Concrete Structure)

  • 한상훈;박우선;김동현
    • 한국해안해양공학회지
    • /
    • 제15권2호
    • /
    • pp.71-79
    • /
    • 2003
  • 본 논문에서는 염소이온 침투해석에 사용되는 염소이온 확산계수. 염소이온 고정화 관계식, 증발가능 수량에 대한 일반 예측식들을 제시하였다. 이러한 식들을 염소이온 확산 모델링에 대입하여 그 식들의 유효성을 검토하였다. 상대습도와 양생온도의 염소이온 확산에 대한 영향은 주로 확산계수를 변화시켜 고려한다. 상대습도가 증가하면 염소이온 확산깊이는 증가하고 재령이 경과할수록 상대습도가 확산깊이에 미치는 영향은 커진다. 반면에, 양생온도가 증가하면 확산깊이가 조금 증가하지만 재령이 경과할수록 양생온도가 확산깊이에 미치는 영향은 감소한다. 한편, 염소이온의 고정화에 영향을 미치는 시멘트의 $C_3$A양이 증가하면 표면에서는 고정염소이온의 증가로 인해 전체 염소이온량이 증가하지만 깊이가 깊어질수록 확산되는 자유염소이온의 감소로 인해 전체 염소이온량이 감소한다. 물-시멘트비가 감소하면 염소이온의 확산깊이는 급격히 감소하고 염소이온의 확산을 막는 가장 효과적인 방법은 물-시멘트비를 감소시키는 것임을 알 수 있다

고로슬래그 미분말 콘크리트의 염화물이온 확산모델 (A Chloride Ion Diffusion Model in Blast Furnace Slag Concrete)

  • 이석원;박상순;송하원;변근주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.467-472
    • /
    • 2000
  • It is known that chloride ion in concrete destroys the passive film of reinforcement inside concrete and accelerates corrosion which is the most influencing factor to durability of concrete structures. In this thesis, a chloride ion diffusion model for blast furnace slag(BFS) concrete, which has better resistance to both damage due to salt and chloride ion penetration than ordinary portland cement concrete, is proposed by modifying existing model of normal concrete. Proposed model is verified by comparing diffusion analysis results with both results by indoor chloride penetration test for specimens and field test results for actual RC bridge pier. Also, the optimum resistance condition to chloride penetration is obtained according to degrees of fineness and replacement ratios of BFS concrete. As a result, resistance to chloride ion penetration for BFS concrete is more affected by replacement ratio than degree of fineness.

  • PDF

LIBS를 활용한 모르타르 단면 염화물 침투 분석 (Analysis of Chloride Penetration in Mortar Sections using Laser Induced Breakdown Spectroscopy)

  • 박원준
    • 한국건축시공학회지
    • /
    • 제21권6호
    • /
    • pp.583-591
    • /
    • 2021
  • 본 연구에서는 모르타르 내 침투염화물 분석에서의 LIBS 적용성과 재현성 검토를 수행하였다. 염화물 농도별 촉진 및 침지된 모르타르를 대상으로 표준분석(IC, 전위차 적정법)과 LIBS 분석을 동시에 진행하였다. 표준분석 결과, 염화물 농도와 함량이 침투깊이 별로 뚜렷하게 나타났다. 침투농도별 동일깊이의 분말시료를 대상으로 용출액을 만들고 LIBS 분석을 한 결과, Cl는 837.59nm 파장에서 깊이, 농도에 따라 신호강도가 확인되었고, LIBS 신호 강도와 Cl농도 사이의 높은 상관관계를 확인할 수 있었다. 수용액 기반의 LIBS 분석이지만 혼입(내재) 염화물 뿐만 아니라 침투 염화물량 분석에도 LIBS 적용 가능성과 재현성을 확인하였다.

염화물 고정화를 고려한 철근 콘크리트 구조물의 내구수명 예측 (Service Life Prediction of R.C. Structures Considering Chloride Binding)

  • 이창수;박종혁;김영욱
    • 한국방재학회 논문집
    • /
    • 제10권1호
    • /
    • pp.15-22
    • /
    • 2010
  • 자연환경 중 다양한 형태로 존재하는 염화물은 콘크리트 구조물의 철근 부식을 야기하며 이에 따른 심각한 내구성 저하와 함께 구조물의 수명을 감소시킨다. 현재 콘크리트 중의 염화물 침투 특성을 규명하기위한 연구는 해안가 장기 폭로 시험과 전기화학적 촉진 시험에 의한 확산계수 평가 등에 의해 지속적인 발전을 이루어왔으나 콘크리트의 배합, 수화도, 고정화능력, 공극률의 재료적 특성을 고려한 이성적이며 포괄적인 염화물 침투 모델에 관한 연구는 부족한 실정이다. 따라서 본 연구에서는 실내 염화물 침지 실험을 통해 콘크리트의 염화물 고정화 특성을 파악하고 이를 고려한 염화물 침투 모델로서 비정상상태의 염화물 침투 해석과 함께 해양침지환경하의 철근콘크리트 구조물의 내구수명 예측을 시도하였으며 SHRP 기준과 20~40%의 내구수명의 차이를 보였다.

확산과 이송을 고려한 콘크리트의 염소이온 침투해석 (Chloride Penetration into Concrete in Tidal Zone by Diffusion-Convection Analysis)

  • 김기현;차수원;정형목
    • 한국전산구조공학회논문집
    • /
    • 제22권6호
    • /
    • pp.607-615
    • /
    • 2009
  • 본 논문에서는 염소이온의 확산과 이송해석이 가능한 유한요소해석 프로그램을 개발하였으며, 해양 간만대의 건습 반복 조건을 고려하여 염소이온 침투해석을 수행하였다. 염소이온 침투에 영향을 미치는 열과 수분의 전달을 동시에 고려하였으며, 특히 염소이온 이송을 생성항 또는 소멸항으로 처리하여 온도, 상대습도, 염소이온농도를 순차적으로 풀 수 있도록 하였다. 건습 반복 주기를 변수로 한 유한요소해석 결과와 ACI Life-365방법에 의한 침투 프로파일의 비교를 통하여, Life-365 방법은 해중에서의 염소이온 침투에 대해서는 정확한 결과를 주지만 간만대의 해석결과는 건습 주기의 영향을 고려하지 못하는 것을 확인하였다. 실제 해양 콘크리트는 다양한 건습 주기의 간만대 환경에 노출되어 있으므로, 정밀한 염소 이온 침투해석을 위해서는 확산-이송 해석을 수행해야 할 것으로 생각된다.