• Title/Summary/Keyword: Chloride diffusion

Search Result 496, Processing Time 0.027 seconds

Durability Estimation of Fire-Hit Concrete Structure to the Chloride Ion (화재의 영향을 받은 콘크리트 구조물의 염해내구성 예측에 관한 연구)

  • Park, Dong-Cheon;Kang, Byeung-Hee
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.219-220
    • /
    • 2010
  • The purpose of this study is to evaluate chloride ion attack durability of concrete structure having experienced the high temperature fire. Mechanical properties and anti chloride ion diffusivity of concrete specimens were measured which have experienced of 2 hours heating at $200{^{\circ}C},\;400{^{\circ}C},\;600{^{\circ}C},\;800{^{\circ}C}$. The coupling FE model of thermal transfer and chloride ion diffusion was built to predict the life expectancy of RC structure using the property values by a series of experiment.

  • PDF

Effect of Time-dependancy of Surface Chloride Content on the Time-to-corrosion Initiation in concrete (콘크리트 표면염화물량의 시간의존성이 철근부식 개시시기에 미치는 영향)

  • Moon, Han-Young;Kim, Hong-Sam;Kim, Seong-Soo;Choi, Doo-Sun;Lee, Jong-Suk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.201-204
    • /
    • 2005
  • The initiation of steel corrosion due to chloride diffusion is predicted to consider time-dependancy of surface chloride content. the profile of chloride concentration is the following: constant condition > square root condition > linear condition From these results, the initiation of steel corrosion in concrete is reverse order of above results of chloride profile. the effect of prolongation to initiation of steel corrosion is decreased with increasing concrete cover

  • PDF

Experimental Study on the Relationship between Time-Dependent Chloride Diffusion Coefficient and Compressive Strength (시간의존성 염화물 확산계수와 압축강도 상관성에 대한 실험적 연구)

  • Lee, Seung-Hoon;Kwon, Seung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.715-726
    • /
    • 2012
  • Since strength and diffusion coefficient of concrete, representative concrete properties that in change with age, the time effect must be considered in the analysis of chloride penetration. In this study, an evaluation of correlation between accelerated diffusion coefficient, apparent diffusion coefficient, and compressive strength in high performance concrete with various mineral admixtures such as ground granulated blast furnace slag, fly ash, and silica fume was performed. For this work, thirty mix proportions were prepared. Accelerated diffusion coefficients at the age of 28, 91, 180, and 270 days were evaluated. For apparent diffusion coefficient, submerging test for 6 months was performed. For evaluation of compressive strength with ages, the compressive strength test was carried out at an age of 7, 28, 91, 180 days. The results of accelerated diffusion coefficient, apparent diffusion coefficient, and strength were compared, and the correlation was analyzed considering time dependency. From this study, linear relationship between accelerated diffusion and apparent diffusion coefficient were obtained regardless of concrete age. The linear relations were also observed in strength-accelerated diffusion coefficient and strength-apparent diffusion coefficient regardless of concrete age.

The Resistance of Penetrability and Diffusion of Chloride Ion in Blended Low Heat Type Cement Concrete (저발열형 시멘트 콘크리트의 염소이온 침투$\cdot$확산에 대한 저항성)

  • 문한영;신화철
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.4
    • /
    • pp.31-41
    • /
    • 1999
  • Blended Low Heat type cement is ground granulated blast furnace slag and fly ash mixed ternary with ordinary portland cement. From the viewpoint of X-ray patterns of domestic LHC, the main components of cement such as $C_2$S, $C_3$A, $C_3$S are considerably reduced. Therefore the heat evolution of LHC paste is 42cal/g lower than of OPC paste. At early age, the compressive strength development of LHC concrete is delayed, but the slump loss ratio of fresh concrete is reduced more than 20% with elapsed time. The penetrability of LHC is lower than that of OPC by 1/7.8 with the penetrability of chloride ion into the concrete until the age of 120 days. And the PD Index value of LHC is 0.44$\times$10-6 $\textrm{cm}^2$/s, which indicates only 39.3% of OPC. From the Mercury Intrusion Porosimetry test of cement past, we know that the pore size of LHC is more dense than that of OPC by production of C-S-H.

Durability performance of concrete containing Saudi natural pozzolans as supplementary cementitious material

  • Al-Amoudi, Omar S. Baghabra;Ahmad, Shamsad;Khan, Saad M.S.;Maslehuddin, Mohammed
    • Advances in concrete construction
    • /
    • v.8 no.2
    • /
    • pp.119-126
    • /
    • 2019
  • This paper reports an experimental investigation conducted to evaluate the durability performance of concrete mixtures prepared utilizing blends of Type I Portland cement (OPC) and natural pozzolans (NPs) obtained from three different sources in Saudi Arabia. The control concrete mixture containing OPC alone as the binder and three concrete mixtures incorporating NPs were prepared keeping water/binder ratio of 0.4 (by weight), binder content of $370kg/m^3$, and fine/total aggregate ratio of 0.38 (by weight) invariant. The compressive strength and durability properties that included depth of water penetration, depth of carbonation, chloride diffusion coefficient, and resistance to reinforcement corrosion and sulfate attack were determined. Results of this study indicate that at all ages, the compressive strength of NP-admixed concrete mixtures was slightly less than that of the concrete containing OPC alone. However, the concrete mixtures containing NP exhibited lower depth of water penetration and chloride diffusion coefficient and more resistance to reinforcement corrosion and sulfate attack as compared to OPC. NP-admixed concrete showed relatively more depth of carbonation than OPC when subjected to accelerated carbonation. The results of this investigation indicates the viability of utilizing of Saudi natural pozzolans for improving the durability characteristics of concrete subjected to chloride and sulfate exposures.

Corrosion initiation time models in RC coastal structures based on reliability approach

  • Djeddi, Lamine;Amirat, Abdelaziz
    • Advances in concrete construction
    • /
    • v.9 no.2
    • /
    • pp.149-159
    • /
    • 2020
  • The present work proposes new engineering models for determining corrosion initiation time in concrete reinforcing steels in marine environment. The models are based on Fick's second law that is commonly used for chloride diffusion. The latter is based on deterministic analyses involving the most influencing parameters such as distance of the concrete structure from the seaside, depth of steel concrete cover, ambient temperature, relative humidity and the water-cement ratio. However, a realistic corrosion initiation time cannot be estimated because of the uncertainties associated to the different parameters of the models. Therefore a reliability approach using FORM/SORM method has been applied to develop the proposed engineering models integrating a limit state function and a reliability index β. As a result, the corrosion initiation time is expressed by new exponential engineering models where the uncertainties are associated to the model parameters. The main emerging result is a realistic decision tool for corrosion planning inspection.

Durability Evaluation of RC Structures subjected. to Chloride Attack (철근콘크리트 구조물의 염해 내구성 평가)

  • 백승우;남진원;송하원;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.663-668
    • /
    • 2003
  • In this paper, an environmental factor and a durability resistance factor which adapts the concept of the Load Resistance Factor Design for safety design of RC structures is derived and a basic principle of a durability evaluation for RC structures using the factors is proposed. It is shown that durability of RC structures can be evaluated by comparing predicted value of chloride ion concentration with limit value of concentration for steel corrosion generation in reinforcement steel position and the durability of concrete manufactured for the RC structures can be also evaluated by comparing characteristic diffusion coefficient of concrete with predicted diffusion coefficient during mixture design.

  • PDF

Physical and Mechanical Properties of Low Carbon Green Concrete (저탄소 그린콘크리트의 물리·역학적 특성)

  • Cho, Il Ho;Sung, Chan Yong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.3
    • /
    • pp.123-128
    • /
    • 2013
  • This study was performed to evaluate the slump flow, air content, setting time, compressive strength, adiabatic temperature rise and diffusion coefficient of chloride used ordinary portland cement, crushed coarse aggregate, crushed sand, river sand, fly ash, limestone powder, blast furnace slag powder and superplasticizer to find optimum mix design of low carbon green concrete for structures. The performances of low carbon green concrete used fly ash, limestone powder and blast furnace slag powder were remarkably improved. This fact is expected to have economical effects in the manufacture of low carbon green concrete for structures. Accordingly, the fly ash, limestone powder and blast furnace slag powder can be used for low carbon green concrete material.

Development and Application of Unit Table Form using Euro Form for High-rise Building Construction (슬래그 혼입 콘크리트의 염소이온 차단성능)

  • Park, Dong-Cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.136-137
    • /
    • 2018
  • The properties of concrete produced by ready mixed concrete company in Busan were measured. Because the concrete was mixed with blast furnace slag and fly ash etc., the compressive, tensile strength and chloride ion diffusion coefficient were lower than OPC concrete even though the specified concrete strength was same. If the durability about salt attack were satisfied, the concrete of lower specified concrete strength would be adopted to concrete mixing design. FEM analysis was carried out to predict the life time expectancy.

  • PDF

Chloride Ion Diffusion for Ready Mixed Concrete (설계기준 압축강도별 레미콘의 염소이온 확산 특성평가)

  • Park, Dong-Cheon;Kim, Yong-Ro
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.149-150
    • /
    • 2018
  • The RC buildings which are constructed on the seaside are followed by KBC(2016) to achieve the minimization of durability damage. To control the corrosion of the reinforced steel bar by salt attack, W/C should be under 0.4 and specified concrete strength is more than 35MPa in the concrete/building construction standard specification. Ready mixed concretes which have usually include the admixtures in Busan were tested to certify the salt attack durability. In the same specified concrete strength, remarkable salt attack durability was evaluated in comparison to OPC.

  • PDF