• 제목/요약/키워드: Chloride Ion

검색결과 1,128건 처리시간 0.025초

항만구조물의 비파괴시험에 의한 안정성 검토 (The Evaluation of Durability by NDT test of Marine-Concrete Structures)

  • 조병완;이일근;강희풍
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.169-172
    • /
    • 1995
  • Establishment of a diagnosing technology for the deterioration of reinforced concrete structures due to salt contamination is urgent, but few analytical methods based on measured data obtained from concrete structures have been presented so far. Chloride penetration into concrete from sea water is generally understood and analysed as diffusion of chloride ion. This paper presents a new method of predicting chloride penetration into concrete based on diffusion theory. Also, it determines the duralility of Marine structure in service with the prediction of remaiing lifetime by the carvonation test.

  • PDF

세포탁심의 공장 및 비점막흡수에 미치는 이온쌍의 효과 (Effect of Ion-Pair on Jejunal and Nasal Absorption of Cefotaxime)

  • 박기배;전승;이광표
    • Journal of Pharmaceutical Investigation
    • /
    • 제25권4호
    • /
    • pp.353-363
    • /
    • 1995
  • The purpose of this study was to investigate the intestinal and nasal absorption enhancement of cefotaxime (CTX) by ion-pairing with counterions and to design an effective oral and intranasal drug delivery system for antibiotics. Counterions for absorption promotion were cationic surfactants [cetylpyridinium chloride (CP), cetrimide (CT) and benzalkonium chloride (BA)]. In the presence of counterions, the apparent partition coefficient of cefotaxime was increased depending on the molar concentration of the counterions. Anion interference was observed for ion-pairing of cefotaxime with counterions because of the counterbalance between an anion and counterions. The present study employed the in situ simultaneous nasal and intestinal perfusion technique in rats. The apparent permeabilities $(P_{app})$ of cefotaxime were $1.43{\pm}0.04{\times}10^{-5}\;cm/sec(mean{\pm}S.E)$ in the nasal cavity and 0 in the jejunum, respectively, which indicated that the intrinsic absorptivity of cefotaxime was greater in the nasal cavity than in the jejunum. When ionupairing formers were used, the decreasing order of apparent cefotaxime permeability $(P_{app},\;10^{-5}\;cm/sec)$, corrected for surface area of absorption, was as followings: $BA\;(7.50{\pm}0.36)\;>\;CT\;(4.92{\pm}0.24)\;>\;CP\;(3.01{\pm}0.17)$ in the jejunum and $BA\;(22.31{\pm}1.36)\;>\;CP\;(18.24{\pm}0.81)\;>\;CT \;(16.22{\pm}1.87)$ in the nasal cavity. The increase in permeability of cefotaxime was about 13-fold in the rat nasal cavity and was marked in the rat jejunum for ion-pairing with counterions as compared to those without ion-pairing. The damages of jejunal and nasal mucosal membrane by counterions were observed within approximately 2hrs after removal of ion-pair of cefotaxime with counterions from the nasal cavity and jejunum. These results suggest that CP can be used as an ion-pairing former in the jejunum and CP and CT can be used as ion-pairing formers in the nasal cavity for cefotaxime, as well as for poorly absorbed drugs with a negative charge due to ionization.

  • PDF

Enhanced Classical Tafel Diagram Model for Corrosion of Steel in Chloride Contaminated Concrete and the Experimental Non-Linear Effect of Temperature

  • Hussain, Raja Rizwan
    • International Journal of Concrete Structures and Materials
    • /
    • 제4권2호
    • /
    • pp.71-75
    • /
    • 2010
  • The chloride ion attack on the passive iron oxide layer of reinforcement steel embedded in concrete under variable temperature environment is influenced by several parameters and some of them still need to be further investigated in more detail. Different school of thoughts exist between past researchers and the data is limited in the high temperature and high chloride concentration range which is necessary with regards to setting boundary conditions for enhancement of tafel diagram model presented in this research. The objective of this paper is to investigate the detrimental coupled effects of chloride and temperature on corrosion of reinforced concrete structures in the high range by incorporating classical Tafel diagram chloride induced corrosion model and laboratory controlled experimental non-linear effect of temperature on corrosion of rebar embedded in concrete.

중성화가 콘크리트의 염소이온 확산특성에 미치는 영향에 관한 실험연구 (Effects of Carbonation on Chloride Diffusion Properties of Concrete)

  • 오병환;강의영;정상화;김선우;서정문
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.429-432
    • /
    • 2000
  • The studies on chloride diffusion of concrete have been done so far by many researchers. However, there are few studies on the effects of other attacks, like carbonation, on chloride diffusion properties. In this study, the experiments are carried out focusing on this by varying cement type, water to cement ratio and replacement of fly ash of concrete. The results show that carbonation attacks do not affect greatly chloride diffusion properties of plain concrete, while the different tendencies are exhibited for fly ash concrete. Therefore, it is desirable to consider the effects of carbonation attacks on the chloride diffusion model to predict accurately the penetration of chloride ion fly ash is partially replaced for cement.

  • PDF

벤질할라이드의 할로겐交煥反應 (第 1 報) 鹽化 및 臭化 벤질과 鹽素 및 臭素이온과의 反應速度 (Halogen Exchange Reactions of Benzyl Halides (Part I) Kinetics of Reactions of Chloride and Bromide Ions with Benzyl Chloride and Bromide)

  • 정경훈;허연;이익춘
    • 대한화학회지
    • /
    • 제9권3호
    • /
    • pp.148-151
    • /
    • 1965
  • Benzyl chloride 및 bromide와 chloride 및 bromide ion 간의 반응을 90% ethanol 용액에서반응속도론적으로 연구하였다. 반 정량적인 결과의 해석은 bond-formation 이 bond-breaking보다 더 중요하고 또 결합형성 과정에서는 형성으로 얻은 energy보다는 nucleophile의 electron affinity의 증가로 인한 차이가 더 중요함을 보여주고 있다.

  • PDF

변색법을 활용한 해양 콘크리트 구조물의 염해평가 (Evaluation on Chloride Attack by Colormetric Method in Marine Concrete Structures.)

  • 박진호;김명유;곽상윤;양은익;박해균
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.181-184
    • /
    • 2005
  • When concrete structures are exposed under marine condition for a long time, the steel in concrete is corroded due to the ingression of chlorides in the seawater. Because the damages of corrosion resulting from the chloride ion are very serious, many researches have been performed. However evaluation on chloride attack of concrete structures are not fully examined, recently. Therefore, the objective of this paper is to study the applicability of colormetric method. For the purpose of this, reaction mechanism of colormetric method were investigated, and the colormetric method is applied for marine concrete structures. According to the test results, the diffusion coefficient by colormetric method is not so different to the value of chloride concentration profile test. It is confirmed that the colormetric method is useful tool for estimating the chloride of concrete structures in situ. The average chloride amount of colored parts indicates 0.9kg/$m^{3}$ per concrete unit weight.

  • PDF

단위시멘트량이 다른 콘크리트 중에서의 철근부식 임계염화물량에 관한 연구 (Study on the Critical Threshold Chloride Content for Steel Corrosion in Concrete with Various Cement Contents)

  • 양승규;김동석;엄태선;이종열;하야극재
    • 콘크리트학회논문집
    • /
    • 제20권4호
    • /
    • pp.415-421
    • /
    • 2008
  • 콘크리트 중의 철근부식은 콘크리트 제조시 초기부터 콘크리트 중에 존재하는 염소이온과 기상작용 등의 환경요인에 의하여 외부로부터 침투하는 염소이온이 어느 값 (임계염화물량) 이상의 경우에 발생한다. 이 때문에 각 국에서는 콘크리트 중의 염소이온량의 상한치를 규제하고 있으며, 국가별 상황에 적절하게 상이한 방법으로 규제하고 있다. 따라서 본 연구에서는 콘크리트 중 염소이온량의 합리적인 규제방법을 제안하기 위하여, 단위시멘트량이 다른 콘크리트 중의 염소이온에 의한 철근부식 임계 염화물량을 실험적으로 산출하였다. 그 결과, 철근부식 임계염화물량은 단위시멘트량의 변화에 따라 크게 변화하는 것을 알 수 있었다. 또한, 실험으로부터 얻어진 철근부식 임계염화물량은 기존의 모델계산의 결과와 잘 일치함을 알 수 있었다. 현행과 같이 철근부식 임계염화물량을 콘크리트 단위체적 당의 양 (콘크리트 총량표기)으로 단위시멘트량에 관계없이 일률적으로 관리하면, 단위시멘트량 등의 콘크리트 배합조건, 환경조건의 변화 등이 철근부식 임계염화물량에 미치는 영향을 고려할 수 없을 것으로 판단된다. 따라서, 철근부식 임계염화물량을 단위시멘트량 당의 양 (시멘트 종량표기)으로 표기하는 것으로, 단위시멘트량에 관계없이 일정한 값으로 표시할 수 있기 때문에 합리적이라고 판단된다.

알칼리 수전해용 격막으로서 폴리염화비닐(polyvinyl chloride) 음이온교환막의 제조에 관한 연구 (Study on the Preparation of Polyvinyl Chloride Anion Exchange Membrane as a Separator in the Alkaline Water Electrolysis)

  • 박종호;봉수연;유철휘;황갑진
    • 멤브레인
    • /
    • 제23권6호
    • /
    • pp.469-474
    • /
    • 2013
  • 알칼리 수전해용 격막으로 사용하기 위해 음이온교환막을 제작하였다. 음이온교환막은 PVC (polyvinyl chloride)를 출발물질로 하여 클로로메틸화 및 아민화에 의해 제작하였다. 제작한 막은 막 특성(막 저항, 이온교환용량)을 평가하였다. 제작한 음이온교환막의 1M NaOH수용액에서의 최저 막 저항은 $2.9{\Omega}{\cdot}cm^2$를 나타냈다. 이 막은 2.17 meq./g-dry-membrane의 이온교환용량과 43.4%의 함수율을 보였다. 제작한 음이온교환막의 막 특성을 시판의 막 특성과 비교 평가하였다. 1M NaOH수용액에서의 막 저항은 AHT>IOMAC>Homemade membrane>AHA>APS=AFN의 순으로 저항 값이 높았다. 이온교환 용량은 Homemade membrane>AFN>APS>AHT>AHA>IOMAC의 순으로 높은 값을 가졌다.

전도성 광촉매를 이용한 콘크리트 철근의 염해 내구성 향상에 관한 연구 (Improvement of Seawater Corrosion Resistance of Concrete Reinforcing Steel Using by Conductive Photocatalyst)

  • 배근국;배근우;안용식
    • 한국건설순환자원학회논문집
    • /
    • 제5권2호
    • /
    • pp.152-159
    • /
    • 2017
  • 해양환경에서 콘크리트의 내구성과 철근의 부식은 콘크리트 내부로 침투하는 염소이온에 의해 악화된다. 본 연구에서는 염소이온에 의해 야기되는 콘크리트의 염해부식에 대한 저항성을 향상시키기 위해 전도성 광촉매를 사용하였다. 시험체로는 전도성 활성탄소와 광촉매($TiO_2$)분말을 혼합하여 모르타르와 콘크리트를 제작하였다. 전도성 탄소의 함량이 증가할수록 압축강도는 감소하였다. 전도성 광촉매가 첨가된 시험체가 일반 시험체보다 월등히 우수한 내염해부식성을 나타내었으며 이것은 XRF 시험에 의한 분석 결과 모르타르 또는 콘크리트 내부로의 염소이온 확산이 광촉매 작용에 의해 억제되었기 때문인 것으로 판단되었다. 모르타르 및 콘크리트 내부로의 염소이온 확산계수를 구함으로써 광촉매에 의한 염소이온 확산에 대한 억제반응이 분석되었다.

Vinyl Benzyl Chloride로 제조된 음이온 교환막의 구조적 고찰 및 전기화학적 특성 (Structural Studies in Anion Exchange Membrane Prepared by Vinyl Benzyl Chloride and its Electrochemical Properties)

  • 송지혜;서봉국;최용진
    • 멤브레인
    • /
    • 제25권4호
    • /
    • pp.310-319
    • /
    • 2015
  • 음이온 교환막의 치환체 특성을 파악하기 위하여 탄화수소의 분자구조가 다른 세 종류의 음이온 교환기를 vinyl benzyl chloride (VBC) base 막에 도입하였다. 지방족계로 trimethylamine (TMA), 고리형계로 N-methylpiperidine (MP), 방향족계로 pyridine (Py)은 아민화 반응을 통하여 도입되었다. 각각의 반응속도는 막저항(MER)과 이온교환능력(IEC) 변화의 관측으로부터 Py < MP < TMA의 순서로 반응하고 있음을 보여주었다. 한편 SEM image에서는 Py 치환체 막이 가장 균일하고 치밀한 구조를 보여주었으며, 전기화학적 특성에서도 Py이 상용막(AMX)과 비슷한 막저항($5.0{\Omega}{\cdot}cm^2$ >, in 0.5 mol/L NaCl)을 나타내었다. 이 모든 결과로부터 치환체의 공명구조는 균질한 이온교환막의 제조에 기여하고 있음을 알 수 있었다.