비상시 열원중단에 따른 데이터센터의 냉각시스템 열성능 평가에 관한 사례연구 (A Study on Thermal Analysis for a Data Center Cooling System under Fault Conditions at a Chilled Water Plant)

  • 조진균;강호석
    • 설비공학논문집
    • /
    • 제28권5호
    • /
    • pp.178-185
    • /
    • 2016
  • This study describes the analysis of a 20 MW chilled water plant used for the IT cooling of a recently constructed data center in Korea. The CFD model was developed with the aim of evaluating the impact of problems such as chiller failure on the water and air temperatures in the cooling system. The numerical model includes the chilled water hydraulic network and individual water-to-air CRAC units. The coupling between the IT server room air temperature levels and the cooling plant has enabled a full assessment of the cooling system design in response to system fault conditions to be performed. The paper examines an emergency situation involving the failure of the cooling plant, and shows how the inherent thermal inertia of the system along with additional inertia achieved through buffer systems allowed a suitable design to be achieved.

냉수침지 숙성법이 진공포장 한우육의 연도 및 미생물 증식에 미치는 효과 (Effects of Submersion Aging in Chilled Water on Tenderness and Microbial Growth of Vacuum-Packed Hanwoo Meat)

  • 주선태;이한기;강근호;신철우;양한술;문성실;이정일;김영환;박구부
    • 한국축산식품학회지
    • /
    • 제22권3호
    • /
    • pp.228-233
    • /
    • 2002
  • 본 연구는 진공포장 한우육의 냉수침지 숙성방법이 한우육의 연도 및 미생물증식에 미치는 영향을 구명하고자 수행하였다. 저장기간이 경과함에 따라 근절길이는 냉수침지 처리구가 저장 3일째 유의적(p<0.05)으로 긴 것으로 나타났으며, 저 장 3일째를 제외 한 저 장기간 동안 유의적 인 차이는 없었으나 대조구에 비해 긴 경향을 보였다. 또한 유리칼슘 농도에 있어서도 저장 7일 째 냉수침지 처리구가 유의적(p<0.05)으로 높게 나타났으며, 역시 저장 7일째를 제외한 저장기간 동안 유의적인 차이는 없었으나 대조구에 비해 높은 경향을 보였다. 한편 전단가와 근원섬유 소편화 지수에 있어서는 저장기간이 경과함에 따라 두 처리구간에 있어서 유의적인 차이는 나타나지 않았지만, 냉수침지 처리구가 상대적으로 낮은 전단가와 높은 소편화지수의 경향을 보였다. 이 같은 결과는 냉수침지 숙성이 일반공기순환냉장고의 숙성보다 근절의 길이를 길게 하고, 근형질내 칼슘의 농도를 높이며, 소편화 지수를 높게 한 결과 연도를 향상시킬 수 있다는 가능성을 제시한 것으로 사료된다. 덧붙여, 총세균수는 일반공 기순환냉장실에 저장한 것에 비해 냉수침지 처리구가 유의적(p<0.05)으로 낮은 것으로 나타나, 온도의 변이를 줄이는 것에 기인하여 미생물의 성장억제에도 효과적일 것으로 사료된다.

복합열원설비 운전온도 최적 설정에 관한 해석적 연구 (An Analytical Study on the Optimal Set-point of the Hybrid Plant)

  • 전종욱;이선일;이태원;김용기;홍대희;김용찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.352-357
    • /
    • 2007
  • The objective of this study is to find the optimal set-point of a hybrid Plant, which is combined by renewable energy plant of the GSHP(Ground Source Heat Pump) and the conventional plant(chiller, boiler). The work presented in this study was carried out by using the EnergyPlus(Version 2.0). In order to validate the simulation model, field data were measured from a building. The GSHP was used as a base plant and the conventional plant as the assistant plant. Various temperatures were controlled (zone summer set-point, zone winter set-point, chilled water temperature, hot water temperature) to find the optimal set-point temperature of the system. The influence of the various set-points were analyzed seasonally.

  • PDF

냉방열원의 경제성 평가를 위한 건물에너지 회귀식 산출 (Energy Regression Analysis for Economic Evaluation of Cooling Plants)

  • 김영섭;김강수
    • 설비공학논문집
    • /
    • 제14권5호
    • /
    • pp.377-384
    • /
    • 2002
  • For economic evaluation of cooling plant equipments, it is necessary to simplify energy Prediction method, which should includes efficiency corrected by part-load ratio. This study proposed simplified method with regression equations of time-average partial loads and refrigerator capacity. DOE-2 Program was used to carry out a parametric study of twelve design variables. Five input variables were considered to be significant and were used in the regression equations. To test accuracy of simplified method, calculated results were compared with DOE-2 simulated results. Test result showes a good agreement with the simulation result with an error of 5.9∼7.6%. It is expected that this method can be used as an easy prediction tool for comparing energy use of different cooling plants during the early design stage.

공랭식 에어컨을 이용한 중앙 집중 공조시스템의 성능 개선에 관한 연구 - 실습선 새누리호를 중심으로 - (A Study on the Improvement of Performance for Centralized Air Conditioning System by Using Air-Cooled Air Conditioner - The Case of Mokpo National Maritime University -)

  • 김홍렬;한승훈
    • 해양환경안전학회지
    • /
    • 제19권2호
    • /
    • pp.207-212
    • /
    • 2013
  • 본 연구에서는 선박의 중앙집중 공조시스템에 공랭식 에어컨을 직접 설치하여 열원의 성능개선과 거주 구역별 독립 냉 난방이 가능한 개별분산 공조시스템을 하고자 하는 것이다. 연구 결과 기존의 중앙집중방식 공조시스템에 비해 열원 제어와 열효율상의 문제점을 보완함과 동시에 장치의 효율을 향상시킴을 확인하였다. 또한 동일한 조건에서 장치의 냉동능력과 성능계수는 평균 약 3 %, 23~26 % 정도 높게 나타났으며, Chilled Water Plants의 압축기 소비동력은 약 12 % 정도 낮게 나타났고, 동일한 조건에서 난방 시 소비동력은 약 33.5 % 낮게 나타났다. 따라서 공랭식 에어컨을 이용한 개별분산 공조시스템이 열원 제어뿐만 아니라 장치의 성능향상과 거주구역별 쾌적한 온 습도 환경 조성에 크게 기여하는 결과를 얻을 수 있었다.

선박의 냉수제조기용 인클로우져에 대한 음향 삽입 손실 분석 (Analysis of the Sound Insertion Loss of the Enclosure for the Chilled Water Plant in a Ship)

  • 한형석;장천익
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.152-157
    • /
    • 2008
  • Enclosure is widely used for the sound insulation in a ship. But it is very difficult to estimate the sound insertion loss for the enclosure because the sound field between the enclosure and the machine is so complex. Therefore, it is usually estimated experimentally. In this research, sound insertion loss of the enclosure is estimated by theory assuming that the sound field in the enclosure is reverberation field. And the results from the theory are compared to those from the experiment.

  • PDF

냉동기 고장경향분석을 통한 설비신뢰도향상 방안 제시 (The Suggestion of Reliability Improvement Method based on Failure Trend Analysis of Chiller)

  • 이상대;염동운;현진우
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.251-255
    • /
    • 2015
  • Chiller system plays an important role of maintaining room temperature constantly by supplying chilled water to Heating, Ventilating and Air Conditioning(HVAC)or area room cooler equipment during plant normal operation or accident condition. Chiller failures are one of the most frequently occurring equipment failures. If the types of chiller failures are analyzed and grouped thoroughly, it would be helpful to make chiller maintenance strategy at the plants. That would enhance equipment reliability of chiller in the end. In this paper, chiller failure data during three years were analyzed and categorized by specific failure code. In addition, the various proposals to improve equipment reliability of chiller were suggested such as Preventive Maintenance Optimization(PMO) strategy and performance monitoring reinforcement and so on.

Regulation of Chilling Tolerance in Rice Seedlings by Plant Hormones

  • Chu, Chun;Lee, Tse-Min
    • 한국작물학회지
    • /
    • 제37권3호
    • /
    • pp.288-298
    • /
    • 1992
  • Since the major important factors limiting plant growth and crop productivity are environmental stresses, of which low temperature is the most serious. It has been well known that many physiological processes are alterant in response to the environmental stress. With regard to the relationship between plant hormones and the regulation of chilling tolerance in rice seedlings, the major physiological roles of plant hormones: abscisic acid, ethylene and polyamines are evaluated and discussed in this paper. Rice seedlings were grown in culture solution to examine the effect of such plant hormones on physiological characters related to chilling tolerance and also to compare the different responses among tested cultivars. Intact seedlings about 14 day-old were chilled at conditions of 5$^{\circ}C$ and 80% relative humidity for various period. Cis-(+)-ABA content was measured by the indirect ELISA technique. Polyamine content and ethylene production in leaves were determined by means of HPLC and GC respectively. Chilling damage of seedlings was evaluated by electrolyte leakage, TTC viability assay or servival test. Our experiment results described here demonstrated the physiological functions of ABA, ethylene, and polyamines related to the regulation of chilling tolerance in rice seedlings. Levels of cis-(+)-ABA in leaves or xylem sap of rice seedlings increased rapidly in response to 5$^{\circ}C$ treatment. The tolerant cultivars had significant higher level of endogenous ABA than the sensitive ones. The ($\pm$)-ABA pretreatment for 48 h increased the chilling tolerance of the sensitive indica cultivar. One possible function of abscisic acid is the adjustment of plants to avoid chilling-induced water stress. Accumulation of proline and other compatible solutes is assumed to be another factor in the prevention of chilling injuies by abscisic acid. In addition, the expression of ABA-responsive gene is reported in some plants and may be involving in the acclimation to low temperature. Ethylene and its immediate precusor, 1-amincyclopropane-1-carboxylic acid(ACC) increased significantly after 5$^{\circ}C$ treatment. The activity of ACC synthase which converts S-adenosylmethionine (SAM) to ACC enhanced earlier than the increase of ethylene and ACC. Low temperature increased ACC synthase activity, whereas prolonged chilling treatment damaged the conversion of ACC to ethylene. It was shown that application of Ethphon was beneficial to recovering from chilling injury in rice seedlings. However, the physiological functions of chilling-induced ethylene are still unclear. Polyamines are thought to be a potential plant hormone and may be involving in the regulation of chilling response. Results indicated that chilling treatment induced a remarkable increase of polyamines, especially putrescine content in rice seedlings. The relative higher putrescine content was found in chilling-tolerant cultivar and the maximal level of enhanced putrescine in shoot of chilling cultivar(TNG. 67) was about 8 folds of controls at two days after chilling. The accumulation of polyamines may protect membrane structure or buffer ionic imbalance from chilling damage. Stress physiology is a rapidly expanding field. Plant growth regulators that improve tolerance to low temperature may affect stress protein production. The molecular or gene approaches will help us to elucidate the functions of plant hormones related to the regulation of chilling tolerance in plants in the near future.

  • PDF

Tomato spotted wilt virus를 위한 간편한 식물바이러스 핵산진단법: Virion Captured/RT-PCR (VC/RT-PCR) (Convenient Nucleic Acid Detection for Tomato spotted wilt virus: Virion Captured/RT-PCR (VC/RT-PCR))

  • 조점덕;김정수;김현란;정봉남;류기현
    • 식물병연구
    • /
    • 제12권2호
    • /
    • pp.139-143
    • /
    • 2006
  • VC/RT-PCR은 바이러스의 단백질과 PCR 튜브의 재질적 특성을 이용하여 바이러스 이병주의 즙액으로부터 핵산을 지니고 있는 바이러스를 polypropylene에 부착시키고 그 외 PCR 활성을 저해하는 식물 즙액은 PBST로 제거해 주므로써 정확하고 깨끗한 바이러스 진단이 가능하다. 이 방법은 바이러스에 대한 항혈청이 전혀 필요 없으며 포장 시료를 직접 이용해 30 분 이내에 바이러스 핵산을 획득할 수 있어 바이러스 진단이 빠르고 간편하며 경제적이고 감도 높은 실용적인 방법이다. TSWV 에 대한 VC/RT-PCR을 위해 다양한 마쇄 완충액을 시험한 결과 0.5%의 Sodium sulphite를 포함한 0.01M Potassium phosphate (pH 7.0)가 가장 안정적이었으며 VC/RT-PCR을 이용하여 TSWV에 대한 최적의 처리 과정을 확립하였다. TSWV에 최적인 완충액에 마쇄한 바이러스 감염 잎의 조즙액을 이용한 한계 희석 농도는 $10^{-5}$으로 높은 감도를 보여 낮은 농도의 바이러스를 보유한 기주로부터 정확하 게 바이러스를 감지해 낼 수 있게 되었다. 두가지 이상의 바이러스에 감염된 기주로부터 두 가지 이상의 프라이머를 이용해 바이러스를 감지해 내는 다중 진단을 위한 실험 중 식물체의 종류와 바이러스의 Primer의 종류가 진단결과의 정확도에 큰 영향을 미치며 이러한 결과는 식물체 즙액을 바로 이용하는 VC/RT-PCR 방법은 물론 식물체로부터 Total RNA를 따로 분리하여 RT-PCR을 이용한 결과에서도 동일하게 나타났다. 따라서 편리하고 실용 적인 VC/RT-PCR법의 정확성을 최대화시키기 위해서는 다중 진단을 저해하는 식물체적 원인과 Primer 사이의 간섭 현상에 대한 연구가 더 진행될 것이며 이러한 원인을 충분히 제거해 줄 수 있는 마쇄 완충액을 개발하고 프라이머 제작을 더욱 신중히 해야 할 것이다.