• Title/Summary/Keyword: Chewing pattern

Search Result 58, Processing Time 0.032 seconds

The Comparison of the Behavior between Miniature Pigs and Conventional Sows during Gestation to Lactation Period (미니돼지 및 일반 돼지의 임신기, 분만 및 포유기 중의 모돈의 행동학적 특성 비교)

  • Kang, Kyung-Won;Choi, Young-Hwan;Kim, Kwang-Ho;Kim, Yoo-Yong
    • Journal of Animal Science and Technology
    • /
    • v.52 no.1
    • /
    • pp.57-64
    • /
    • 2010
  • This study was conducted to compare the aspects of behavior between miniature pigs and conventional sows during gestation and lactation periods. Miniature pigs and conventional sows at 3 parity were used in this experiment with 4 pigs per treatment. The behavioral patterns and stereotyped behaviors were observed on day 60 and 90 of gestation, at farrowing, and on day 10 of lactation before and after the feeding. On 60 and 90 days of pregnancy, both treatments showed the tendency of frequent lateral lying rather than other postures. On ventral lying, eating and drinking, miniature pigs spent more time than conventional pigs at day 90 of gestation (P<0.01, P=0.0539, P<0.05, respectively). The occurrence of stereotyped behaviors included bar biting and bar mouth chewing. At 90 day of pregnancy was observed, conventional pigs was higher than miniature pigs (P<0.05). At farrowing, miniature pigs spent more time on ventral lying, standing and walking than conventional sows (P<0.05), however, there were more frequency of drinking and eating. And on day 10 of lactation, there was no significant difference in stereotyped behaviors between miniature pigs and conventional sows. In conclusion, miniature pigs were generally more sensitive than conventional sows although sows were reared in stall during gestation and lactation period and the behavioral pattern during lactating period showed the similarity between miniature pigs and conventional sows for protection of nursing pigs. In consideration of the general reproductive performance of conventional sows, the high sensitivity and stress of miniature pigs did not affect the reproductive performance of miniature pigs.

Stress analysis according to the different angulation of the implant fixture (임플란트 고정체의 매식 경사에 따른 응력분석)

  • Lee, Tae-Yup;Kang, Dong-Wan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.4
    • /
    • pp.321-329
    • /
    • 2002
  • Bending moments results from offset overloading of dental implant, which may cause stress concentrations to exceed the physiological capacity of cortical bone and lead to various kinds of mechanical failures. The purpose of this study was to compare the distributing pattern of stress on the finite element models with the different angulated placement of dental implant in mandibular posterior missing areas. The three kinds of finite element model, were designed according to 3 main configurations: Model 1(parallel typed placement of 2 fixtures), Model 2(15. distal angulated placement of one fixture on second molar area), Model 3(15. mesial angulated placement of one fixture on second molar area). The cemented crowns for mandibular first and second molars were made on the two fixtures (4mm 11.5). Three-dimensional finite element models by two fixtures were constructed with the components of the implant and surrounding bone. A 200N vertical static load were applied to the center of central fossa and the point 2mm apart from the center of central fossa on each model. The preprocessing, solving and postprocessing procedures were done by using FEM analysis software NISA/DISPLAY IV Version 10.0((Engineering Mechanics Research Corporation, USA). Von Mises stresses were evaluated and compared in the supporting bone, fixtures, and abutment. The results were as following : (1) Under the point loading at the central fossa, the direction of angulated fixture affected the stress pattern of implants. (2) Under the offset loading, the position of loading affected more on the stress concentration of implants compare to the angulated direction of implants. The results had a tendency to increase the stress on the supporting bone, fixture and screw under the offset loads when the placement angulation of implant fixture is placed toward mesial or distal direction. In designing of the occlusal scheme for angulated placement, placing the occlusal contacts axially during chewing appears to have advantages in a biomechanical viewpoint.

A STUDY FOR THE CHANGES OF THE MASTICATORY MUSCLES AND THE MANDIBULER MOVEMENT EFFECTED BY INTENTIONAL INCREASE OF ANTERIOR GUIDANCE ANGLE (전치 유도각의 인위적 증가에 의한 저작근과 하악 운동 양상의 변화에 대한 연구)

  • Lee, Yong-Sik;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.245-257
    • /
    • 1998
  • This study was performed to measure the changes of the mandibular movement and the masticatory muscular activities - anterior temporal and masseter muscle of both side - reflected by intentional increase of anterior guidance angie. For this study, 5 volunteers (3 males and 2 females with average age of 24.0) were selected. Each volunteer had Angle's classification I and did not have any missing tooth except third molar and any extensive restorations. Metallic guide plate was made at volunteer's working model fabricated by improved dental stone and cemented to the palatal surface of maxillary central incisor using resin cement(Panavia $21^{(R)}$) and then adjusted not to give any occlusal interferences at intercuspal position. The activity of masticatory muscles and the changes of mandibular movement were recorded by EMG and Sirognathograph in Biopak analysing system(Bioresearch Inc., Milwaukee, Wisconsin, USA). Measurement was done at before experiment, immediatley after placement, 1 week after placement, immediately after removal, and 1 week after removal. The results were as follows: 1. Moderate phonetic disturbance and mild headache were occured to 3 volunteers for 2 days after setting and 1 volunteer had positive reaction to percussion and slight midline diastema. But all of these clinical signs were diappeared 1 week after removal and the other volunteer did not have any special clinical sign. 2. In the EMG of the mandibular rest position, the mean value of anterior tempotal muscle was increased immediately after placement(p<0.01) and then decreased 1 week after placement(p<0.05) and increased 1 week after removal(p<0.05) but not recovered as before experiment. The mean value of masseter muscle was decreased during the experiment period. 3. In the EMG during mandibular protrusive movement, all muscular activity was decreased during the experiment period. Reduced activity was not recovered 1 week after removal(p<0.03). 4. During the habitual opening, anteroposterior movement of mandible was decreased immediately after placement(p<0.05) and then increased 1 week after placement but not statistically significant(p>0.1). Vertical movement was not shown significant difference during the experiment period(p>0.1). Lateral movement was decreased immediately after placement(p<0.05) and then increased 1 week after placement but not recovered as before experiment. The opening and closing velocity of mandible was shown minor changes but not statistically significant. 5. During the habitual opening, anteroposterior movement of mandible was decreased 1 week after placement(p<0.05) and then increased immediately after removal and recovered 1 week after removal as before experiment. Vertical movement was not shown significant changes. Lateral displacement of mandible was increased continuously and recovered 1 week after removal. Opening velocity was temporarily increased immediately after removal but recovered and closing velocity was not shown significant changes. 6. During the right side chewing, anteroposterior movement of mandible was increased immediately after removal but recovered and vertical movement was not shown statistically significant results. Lateral displacement and velocity of mandible were not shown significant results. 7. During the left side chewing, the changes of mandibular movement pattern were not shown statistically significant results.

  • PDF

Evaluation of a Specially Designed Tobacco Control Program to Reduce Tobacco Use among School Children in Kerala

  • Philip, Phinse Mappalakayil;Parambil, Neetu Ambali;Bhaskarapillai, Binukumar;Balasubramanian, Satheesan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.6
    • /
    • pp.3455-3459
    • /
    • 2013
  • Background: Smoking and smokeless tobacco use are almost always initiated and established during adolescence. More than 80% of adult smokers begin smoking before 18 years of age. The main objective of the present study is to assess the feasibility of preventing adolescent tobacco use with the help of a specially designed tobacco control program. Materials and Methods: A cross sectional survey on tobacco use and related health effects was conducted using a structured questionnaire in 13 randomly selected schools in Kannur district of Kerala. These students were followed for a period of one academic year with multiple spaced interventions such as anti-tobacco awareness classes, formation of anti-tobacco task forces, inter-school competitions, supplying IEC (information, education and communication) materials and providing a handbook on tobacco control for school personnel. Final evaluation was at the end of one year. Results: There were 4,144 school children who participated in the first phase of the study. The prevalence of tobacco smoking and chewing habits were 9.85% and 2.24% respectively. Ninety-one percent had parental advice against tobacco use and only 3.79% expressed desire for future tobacco use. The final evaluation witnessed a sharp decline in the current tobacco use as 4.68%. We observed a statistically significant difference towards the future use of tobacco (p<0.001) and awareness about the ill effects of passive smoking (p<0.001) among boys and girls. Further a significantly increased knowledge was observed among boys compared to girls about tobacco and oral cancer (p=0.046). Conclusions: The comprehensive school based tobacco control project significantly reduced the tobacco use pattern in the target population. School tobacco projects incorporating frequent follow ups and multiple interventions appear more effective than projects with single intervention.

Comparison of the fracture resistances of glass fiber mesh- and metal mesh-reinforced maxillary complete denture under dynamic fatigue loading

  • Im, So-Min;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.1
    • /
    • pp.22-30
    • /
    • 2017
  • PURPOSE. The aim of this study was to investigate the effect of reinforcing materials on the fracture resistances of glass fiber mesh- and Cr-Co metal mesh-reinforced maxillary complete dentures under fatigue loading. MATERIALS AND METHODS. Glass fiber mesh- and Cr-Co mesh-reinforced maxillary complete dentures were fabricated using silicone molds and acrylic resin. A control group was prepared with no reinforcement (n = 15 per group). After fatigue loading was applied using a chewing simulator, fracture resistance was measured by a universal testing machine. The fracture patterns were analyzed and the fractured surfaces were observed by scanning electron microscopy. RESULTS. After cyclic loading, none of the dentures showed cracks or fractures. During fracture resistance testing, all unreinforced dentures experienced complete fracture. The mesh-reinforced dentures primarily showed posterior framework fracture. Deformation of the all-metal framework caused the metal mesh-reinforced denture to exhibit the highest fracture resistance, followed by the glass fiber mesh-reinforced denture (P<.05) and the control group (P<.05). The glass fiber mesh-reinforced denture primarily maintained its original shape with unbroken fibers. River line pattern of the control group, dimples and interdendritic fractures of the metal mesh group, and radial fracture lines of the glass fiber group were observed on the fractured surfaces. CONCLUSION. The glass fiber mesh-reinforced denture exhibits a fracture resistance higher than that of the unreinforced denture, but lower than that of the metal mesh-reinforced denture because of the deformation of the metal mesh. The glass fiber mesh-reinforced denture maintains its shape even after fracture, indicating the possibility of easier repair.

A Study on the Amount of Mandibular Rotation and Pattern of Condylar Path (하악운동 회전량과 과로의 형태에 관한 연구)

  • Kyung-Soo Han;You-Me Lee
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.2
    • /
    • pp.369-382
    • /
    • 1996
  • The author performed this study to investige the relationship between condylar movements recorded with Pantronicⓡ and mandibular rotational torque movements with BioEGNⓡ. For this study 56 patients with Temporomandibular disorders(TMD) and 30 dental students without any masticatory signs and symptoms were selected as patients group and control group, respectively. The items recorded with Pantronicⓡ(Denar Corp., USA) were immediate side-shift, progressive side-shift, angle of orbiting path, protrusive path and PRI. BioEGNⓡ(Bioelectric gnathography, Bioresearch Inc., USA) were used to measure the amounts of mandibular rotational torque movements in frontal and horizontal plane, and the distance of mandibular translation at incisal area. Amount of mandibular rotational torque movement depicted between the condyles was automatically analysed by angle and difference in frontal and horizontal plane. The obtained data were processed with SAS program and the conclusion of this study were as follows : 1. Mean values of items between patients group and control group in Pantronic measurements were not significantly different except in left protrusive path and in Pantronic Reproducibility Index(PRI). There were no significant difference of condylar paths by preferred chewing side and affected side between the two groups. 2. The amount of mandibular rotational torque movements were differed in frontal angle and difference on protrusion, and in frontal and in horizontal difference on left excursion between the two groups. But the amounts of translatory movements were actually same on all eccentric movements. 3. The amount of mandibular rotational torque movements with splint mere almost not changed from those without splint, with the exception of in horizontal measurements on protrusion. 4. The correlations of items between in Pantronic measurements and in BioEGN measurements wert not consistently, significant, however, generally the ISS related significantly with horizontal torque movement positively, and with frontal torque movement negatively on the contrary, the PSS showed positive correlation with frontal torque movement, and negative correlation with horizontal torque movement.

  • PDF

THE EFFECT OF MECHANICAL PROCESSING OF HAY ON THE EATING AND RUMINATION BEHAVIOUR IN SHEEP

  • Fujihara, T.;Harumoto, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.4 no.1
    • /
    • pp.7-14
    • /
    • 1991
  • An experiment was carried out to investigate the effect of change in length of hay offered on eating and rumination behaviour in sheep using three types of hay diets (L: long, M: 8.0-cm cut, S: 1.2-cm cut) and 3 Japanese Corriedale wethers, and the experiment was designed as $3{\times}3$ latine square. The time spent eating per 100 g hay was significantly shorter with long (L) hay (p < 0.05) than with chopped (M and S) hay, and therefore, the eating rate (g D.M./min.) was significantly higher in the former (p < 0.05) than in the latter. Rumination appearance (the lag time after eating) tended to be longer with long hay than with chopped hay, but not significantly (p > 0.05). Daily time spent ruminating, the actual chewing time and daily number of chews tended to be more in feeding long hay than in feeding chopped hay, but not significantly. Daily number of rumination periods was significantly more with long hay (p < 0.01) than with chopped hay. Cyclic rate tended to be longer with long hay than with chopped hay, in particular, the difference in values between long hay and 8.0-cm cut hay was significant statistically (p < 0.01). The rumination index (time spent ruminating/100 g D.M, eaten) tended to be higher with long hay than with chopped hay, and the difference in values between long hay and 1.2-cm cut hay was significant statistically (p < 0.05). Bolus time was significantly longer with long hay (p < 0.01) than that with 8.0-cm cut hay. The circadian pattern of ruminating time was not changed by the changes in length of hay eaten.

Eating Patterns of Children with Cerebral Palsy by Table Utensil-Handling Skills (식사도구 사용능력에 따른 뇌성마비아동의 식생활)

  • Kim, Jan-Di;Bae, Yun-Kyung;Cho, Mi-Sook
    • Journal of the Korean Dietetic Association
    • /
    • v.15 no.2
    • /
    • pp.139-151
    • /
    • 2009
  • The purpose of this study was to investigate the eating patterns of children with cerebral palsy having motor disturbances as well as stiffness. The food habits, nutritional status, and snack intakes of 1 to 7 year-old children with cerebral palsy were examined. The subjects were grouped into three categories according to their table-utensil handling skills: superior, normal, and inferior. The children in the superior group were significantly taller and heavier compared to children in the other two groups. The %EARs of folic acid and total calorie intake were insufficient in all three groups; however, their %EARs of other nutrients were fully sufficient. When comparing the children's intake frequencies and preferences for snacks, the superior group showed a greater likelihood to consume various kinds of snacks than the inferior group. And the inferior group disliked more kinds of snacks than the other two groups. It was also shown that the inferior group had a significantly higher tendency for problems in chewing and swallowing. These results indicate that the development of table utensil-handling skills is very important for the food intake and growth of children with cerebral palsy, and the better their table utensil-handling skills the greater their physical development. Thus, considering their preference and intake frequency, it seems necessary that children in the inferior group be provided a greater variety of snacks and foods to receive more calories.

  • PDF

Evaluation of pain experienced by orthodontic patients following elastomeric separator insertion: A cross-sectional study

  • Hareem Sultan;Hana Pervez;Sidra Maqsood;Wajeeh Syed Zeeshan
    • The korean journal of orthodontics
    • /
    • v.53 no.5
    • /
    • pp.298-306
    • /
    • 2023
  • Objective: Pain following the insertion of separators and archwires varies with age, sex, race, ethnicity, threshold, and health status. This study aimed to evaluate the characteristics of pain in orthodontic patients after the insertion of elastomeric separators, its effects on daily life, and its association with age and sex in a population not previously studied in this regard. Methods: A cross-sectional study of 130 patients undergoing orthodontic treatment included collecting data on demographics, pain experienced following the placement of separators, time of onset, duration, characteristics, change in dietary pattern or chewing side, intake of analgesics, and severity of pain on the Wong Baker's scale. The results are reported as counts and percentages. Associations between sex and age were evaluated using Pearson's chi-square test. Results: Among the 130 patients, 56.2% were 9-20 years old, 63.8% experienced pain following the insertion of separators, 22.9% had their first episode of pain at 4 hours, 56.6% experienced intermittent pain, and 37.3% experienced discomfort; 18.1% males and 81.9% females experienced pain following the insertion of separators. Pearson's chi-square test showed a significant association between pain and sex (P = 0.04). Most patients (37.3%) reported "hurts little more" for pain intensity on Wong Baker's scale and 21.7% reported all four quadrants as sites of pain. Conclusions: The pain experienced after separator insertion was associated with sex and age. Females experienced more pain than males and patients between the age range of 21 and 36 years suffered more pain during mastication than between 9 and 20 years old.

Prosthetic full mouth rehabilitation of patient with mandibular prognathism and asymmetry: a case report (하악의 전돌 및 비대칭을 가진 환자에서 보철적 전악 구강회복 증례)

  • Jaeyeong Lim;Hwa-Jeong Lee;Jong-Eun Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.28-37
    • /
    • 2024
  • Severe cases of mandibular prognathism can be treated with orthodontic therapy or surgical correction, but there are situations where only prosthetic improvement is possible. An understanding of class III patients is needed, including a vertical chewing pattern and the absence of anterior guidance. Additionally, it is relatively easy to increase occlusal vertical dimension to correct the anterior crossbite, but this approach can sometimes lead to unfavorable results, necessitating careful diagnosis and treatment planning. In this case report, oral rehabilitation was conducted in a patient with mandibular prognathism and asymmetry, utilizing implants and fixed dental prosthesis. Through a step-by-step treatment approach, the existing occlusal vertical dimension was maintained, and the final fixed dental prosthesis restoration was completed. Accordingly, it shows functional and aesthetically appropriate results, and reports on the patient's diagnosis and treatment process.