• Title/Summary/Keyword: Chest phantom

Search Result 135, Processing Time 0.024 seconds

Optimization of Image Quality according to Sensitivity and Tube Voltage in Chest Digital Tomosynthesis (디지털 흉부단층합성검사에서 감도와 관전압 변화에 따른 영상 최적화)

  • Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.541-547
    • /
    • 2018
  • To evaluate the effect of dose and image quality for Chest Digital Tomosynthesis(CDT) using sensitivity and tube voltage(kV). CDT images of the phantom were acquired varying sensitivity 200, 320, 400 according to set tube voltage of 125 kV and 135 kV. The dose and Dose Area Product(DAP) according to change of sensitivity and kV were evaluated and Image quality was evaluated by PSNR, CNR, SNR using Image J. Dose were lowered 14~23% less than sensitivity 200, 125 kV and DAP were lowered 13~26% less than sensitivity 200, 125 kV. PSNR were over 27 dB, which were significant value and CNR, SNR were better as sensitivity value was lower. But there were different statistical significant to each item. CNR and SNR were not statistically significant at sensitivity 320, 135 kV(P>0.05). CDT can improve image quality with lower radiation dose using better than quality and correction power at digital radiography system.

A Comparative Study of Patient Dose and Image Quality according to the Presence or Absence of Grid During Chest PA Radiography using an Auto Exposure Control System (자동 노출 조절장치를 사용한 흉부 후·전 방향 방사선 검사 시 격자 유·무에 따른 환자 선량과 영상품질 비교 연구)

  • So-min Lee;Han-yong Kim;Dong-hwan Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.573-579
    • /
    • 2023
  • This study compares dose difference between the presence or absence of grid in Chest PA radiography using auto exposure control and compares image quality among presence, absence or virtual grid, and proposes a new clinically useful grid combination for chest radiography. The human body phantom was placed Chest PA position and the dosimeter was placed at T6. The same irradiation conditions and field size were applied. 30 images were obtained in the state in which grid was applied and in the state in which grid was not applied, and an additional 30 images in which the virtual grid was applied to the image without the grid were obtained. Radiation dose was presented to entrance surface dose. The image quality was analyzed by comparing the signal-to-noise and contrast-to-noise ratio. ESD decreased by 48% when the grid was not used, compared to when the grid was used. SNR and CNR increased by 32% and 30% compared to grid use when grid was not used, respectively. In the case of using the virtual grid, it increased by 18% and 16% respectively, compared to the case of using the grid. As a result of this study, it is believed that when using a virtual grid instead of a grid, the quality of the image can be maintained while reducing the patient dose.

The Study of Optimal Acquisition Condition and Image Processing (최적의 촬영조건 및 영상처리에 관한 연구)

  • Lee, Yong-Gu;Shin, Jong-Ho;Seo, Kyoung-Eun;Choi, Yoo-Lee;Lee, Soo-Hyeon;Lee, Young-Jin;Kim, Hee-Joung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.221-226
    • /
    • 2014
  • In this paper, we achieved the study which determined the excellent diagnostic condition and searched the exposure condition with the minimum radiation exposure level having the equal diagnostic ability. To accomplish these study, chest phantom images with lesions and without ones were evaluated at various exposure conditions. With respect to the phantom with lesions and without ones, we obtained the chest PA imaging applied by photographing parts of DR apparatus and the images processed as histogram equalization and edge enhancement method. The images were acquired at the exposure conditions of 2.0, 2.5, 3.2, 4.0 and 5.0mAs. The morphological analysis was performed by ROC curves using the images obtained at each exposure condition. The exposure conditions with the most excellent diagnostic ability and with the equal diagnostic capability having the minimum radiation exposure level were determined by means of sensitivity, specificity and accuracy.

Evaluation of Effective Dose with National Diagnostic Reference Level using Monte-Carlo Simulation (몬테카를로 시뮬레이션을 이용한 국내 일반엑스선검사 진단참고수준의 유효선량 평가)

  • Lee, Seung-Youl;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1041-1047
    • /
    • 2021
  • In this study, the effective dose for frequently general radiography among the diagnostic reference level (DRL) for examinations provided by the government in Korea was evaluated using the Monte Carlo N-Particle eXtended (MCNPX) simulation tool. We were selected to evaluate for a total of 5 examination sites which included head anterior-posterior, chest (posterior-anterior, lateral), abdomen anterior-posterior and pelvis anterior-posterior. Physical conditions such as tube voltage and tube current used in MCNPX simulation were used in domestic conditions of the Korea Disease Control and Prevention Agency (KDCA). To evaluate domestic medical radiation exposure, we used the HDRK-Man computerized human phantom manufactured based on the international standard ICRP 103 that was applied to the MCNPX simulation. The phantom could represent the standard body shape of Koreans. As a results, the effective dose corresponding to the DRL based on adult males of head anterior-posterior position was 0.086 mSv, chest posterior-anterior position was 0.05 mSv, chest lateral was 0.354 mSv, abdomen anterior-posterior position was 0.548 mSv, and pelvis anterior-posterior position was 0.451 mSv.

Image Evaluation of Projection Method in Chest Radiography (흉부 엑스선 촬영 시 촬영기법에 따른 영상 평가)

  • Ahn, Byung-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.217-223
    • /
    • 2022
  • In this study, images taken using a grid and images taken using Air Gap Technique were evaluated in X-ray chest radiography. Subjective Evaluation The ROC (Receiver Operating Characteristic) evaluation was evaluated by 5 radiologists who had worked for more than 10 years in the radiology department of a university hospital. Objective evaluation SNR (Signal to noise ratio) was evaluated. As a result of the analysis, the Cronbach Alpha value was 0.714, which was significantly higher. In the Air Gap Technique, the distance between the phantom and the subject was set at 20 cm, and the image was taken with a tube voltage of 100 kVp, a tube current and a recording time of 8 mAs. In the ROC (Receiver Operating Characteristic) evaluation, the highest score was obtained with 18 score and an objective evaluation SNR (signal to noise ratio) of 6,149 scored. Also, in the imaging method using a grid, when the distance between the phantom and the constant receptor is 15 cm apart, and the tube voltage is 110 kVp, the tube current and the recording time are taken at 8 mAs, the ROC evaluation score is 19 and the objective evaluation SNR (Signal to noise ratio) is the highest with 6.622 scored. Therefore, if the Air Gap Technique imaging method is used, which overcomes the shortcomings such as delay in reading, increase in patient's exposure dose, and shortening of mechanical lifespan, as well as re-radiography due to the cut-off phenomenon of the grid that appears using the grid, the It is thought that it will be very helpful for chest imaging, including the case of using a portable X-ray imaging device.

A Study on the Change of Image Quality According to the Change of Tube Voltage in Computed Tomography Pediatric Chest Examination (전산화단층촬영 소아 흉부검사에서 관전압의 변화에 따른 화질변화에 관한 연구)

  • Kim, Gu;Kim, Gyeong Rip;Sung, Soon Ki;Kwak, Jong Hyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.503-508
    • /
    • 2019
  • In short a binary value according to a change in the tube voltage by using one of VOLUME AXIAL MODE of scanning techniques of chest CT image quality evaluation in order to obtain high image and to present the appropriate tube voltage. CT instruments were GE Revolution (GE Healthcare, Wisconsin USA) model and Phantom used Pediatric Whole Body Phantom PBU-70. The test method was examined in Volume Axial mode using the pediatric protocol used in the Y university hospital of mass-produced material. The tube voltage was set to 70kvp, 80kvp, 100kvp, and mAs was set to smart mA-ODM. The mean SNR difference of the heart was $-4.53{\pm}0.26$ at 70 kvp, $-3.34{\pm}0.18$ at 80 kvp, $-1.87{\pm}0.15$ at 100 kvp, and SNR at 70 kvp was about -2.66 higher than 100 kvp and statistically significant (p<0.05) In the Lung SNR mean difference analysis, $-78.20{\pm}4.16$ at 70 kvp, $-79.10{\pm}4.39$ at 80 kvp, $-77.43{\pm}4.72$ at 100 kvp, and SNR at 70 kvp at about -0.77 higher than 100 kvp were statistically significant. (p<0.05). Lung CNR mean difference was $73.67{\pm}3.95$ at 70 kvp, $75.76{\pm}4.25$ at 80 kvp, $75.57{\pm}4.62$ at 100 kvp and 20.9 CNR at 80 kvp higher than 70 kvp and statistically significant (p<0.05) At 100 kvp of tube voltage, the SNR was close to 1 while maintaining the quality of the heart image when 70 kvp and 80 kvp were compared. However, there is no difference in SNR between 70 kvp and 80 kvp, and 70 kvp can be used to reduce the radiation dose. On the other and, CNR showed an approximate value of 1 at 70 kvp. There is no difference between 80 kvp and 100 kvp. Therefore, 80 kvp can reduce the radiation dose by pediatric chest CT. In addition, it is possible to perform a scan with a short scan time of 0.3 seconds in the volume axial mode test, which is useful for pediatric patients who need to move or relax.

A Study for Reduction of Radiation Dose in the Field of Diagnostic Radiology - A Point of Tube Voltage and Filtration - (진단방사선 영역에서 피폭선량 감소를 위한 기술적 연구 - 관전압과 부가여과판을 중심으로 -)

  • Ha, Ho-Young
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.89-97
    • /
    • 1992
  • X-ray quality is identified numerically by half value layer(H.V.L) and the HVL is affected by the kVp and the amount of filtration in the useful beam. X-ray quality evaluated by H.L.D is influenced by kVp and filtration. Author had several experiments with phantom in diameter of 8 cm normal adult chest, for reduction of radiation dose of the patients in diagnostic radiology and got some results. 1. H.V.L is increased the thicker the filter and the higher the kVp. 2. If the kVp is increased from 60 to 120, the skin dose can be reduced as 34%(Skin dose of 60 kVp with 4 mmAl filter : 100%). 3. If the 4 mmAl filter with 60 kVp is added to x-ray tube, skin dose can be reduced as 23% than no filter. 4. Therefore high kVp and filtration can increase output to input dose ratio and 120 kVp and 4 mmAl filter were most effective for reduction of patient dose in chest radiography.

  • PDF

A Trial of 6 MV Linear Accelerator Radiation Therapy (RT) for Breast Cancer (6 MV 선형가속기를 사용한 유방암 치료)

  • Lee Guy Won;Park Ju Seon;Kim Geol;Yoon Sei Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.1 no.1
    • /
    • pp.37-42
    • /
    • 1985
  • Radiation Therapy(RT) has been used in the treatment of breast cancer for over 80 years. Technically, it should include a part or all of such areas as chest wall or breast, axilla, internal mammary nodes(IM) and supraclavicular nodes (SCL). Authors tried three-field technique for the treatment of breast cancer using 6 MV linear accelerator, exclusively the department of Radiology, Kang-Nam St. Mary's Hospital, at Catholic Medical College. The field junction was checked by a phantom study and radiation doses measured by film densitometry and TLD. The 3 fields we used in this study were two isocentric opposing tangential fields encompassing the breast, chest wall and occasionally IM and one single anterior field encompassing the axilla and SCL. Using appropriate beam blocks and blouses, we were able to avoid unwanted intrinsic divergency of photon beam. Blocking also enabled us to set-up precise radiation field with ease.

  • PDF

The Evaluation of Chest Radiographic Systems (흉부 X선사진 시스템의 성능평가)

  • Kang, Hae-Won;Park, Jun-Chul;Kang, Hong-Seok;Lee, In-Ja;Shin, Wha-Soo;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.10 no.1
    • /
    • pp.31-35
    • /
    • 1987
  • Authors have investigated actual conditions of 22 hospitals throughout the Seoul district to evaluate of chest radiographic systems. The results are as followed: 1. Concerning exposure factors, most hospitals have used low tube voltage, merely two hospitals high tube voltage, that is, over 120 kVp. Roughly halves of intensifying screens have been used in hospitals were medium speed screens, and the rests were high speed screens. 2, Surface doses existed within wide range of $10{\sim}63.5mR$, and image quality value were $5.60{\sim}7.49$. 3. The minimum perceptibility of Burger Phantom have been increased with contrast improvement.

  • PDF

A Trial of 6-MV Linear Accelerator Radiation Therapy (RT) for Breast Cancer (6MV 선형가속기를 사용한 유방암 치료)

  • Yoon S. C.;Kwon H. C.;Oh Y. K.;Kim J. W.;Bahk Y. W.
    • Radiation Oncology Journal
    • /
    • v.2 no.2
    • /
    • pp.303-309
    • /
    • 1984
  • Radiation therapy(RT) has been used in the treatment of breast cancer for over 80years. Technically, it should include a part or all of such areas as chest wall or breast, axilla, internal mammary nodes (IM) and supraclavicular nodes (SCL). Authors tried three-field technique for the treatment of breast cancer using 6-MV linear accelerator, exclusively the department of radiology. Kang-Nam St. Mary's Hospital, at Catholic Medical College. The field junction was checked by a Phantom study and radiation doses measured by film densitometry and TLD. The 3 fields we used in this study were two isocentric opposing tangential fields encompassing the breast, chest wall and occasionally IM and one single anterior field encompassing the axilla and SCL. sing appropriate beam blocks and boluses, we were able to avoid unwanted intrinsic divergency of photon beam. Blocking also enabled us to set-up precise radiation field with ease.

  • PDF