• 제목/요약/키워드: Chest Compression Position

검색결과 25건 처리시간 0.019초

수직추락후 발생한 복부대동맥 협착 1례 보 (Delayed Post-traumatic Coarctation of Distal Abdominal Aorta - A Case Report -)

  • 박국양;이홍섭;김창호
    • Journal of Chest Surgery
    • /
    • 제20권1호
    • /
    • pp.199-201
    • /
    • 1987
  • We have recently experienced a rare case of abdominal aortic injury caused by deceleration force during fall in upright position. The patient was 43-year-old brick-layer fell from 12 meter height and sustained compression fracture of the spine and both legs. The aortic injury was unnoticed at that time. About 2 years later, marked stenosis of the distal abdominal aorta was found together with clinical manifestations of ischemia of both legs. Aorto-femoral bypass on both sides has completely relieved the symptoms, Similar type of abdominal aortic injuries could not be found in the literatures.

  • PDF

앙와위와 좌측 기울린위치에서의 좌심실의 공간적 관계 변화. 임신부 심폐소생술 측면에서 (Spatial Relationship of the Left Ventricle in the Supine Position and the Left Lateral Tilt Position (Implication for Cardiopulmonary Resuscitation in Pregnant Patients))

  • 윤종근;이병국
    • 한국화재소방학회논문지
    • /
    • 제27권5호
    • /
    • pp.75-79
    • /
    • 2013
  • 임신부의 경우 심폐소생술동안 좌측 기울림을 적용하도록 권장하고 있다. 하지만, 이 좌측으로 기울리면 임신부의 자궁 뿐만이 아니라 좌심실도 좌측으로 편위되어 심폐소생술의 심장펌프기능이 떨어질 가능성이 있다. 이에 좌측 기울림이 심폐소생술동안 흉골 운동 방향을 대변하는 전후축과 좌심실의 공간적 관계에 미치는 영향을 알아보고자 하였다. 컴퓨터 단층촬영을 이용한 가상내시경검사를 받은 90명의 환자를 대상으로 의무기록과 컴퓨터단층촬영결과를 후향적으로 조사하였다. 가상내시경은 앙와위와 좌측 기울림 위치 모두에서 실시되었다. 좌심실 단면적이 가장 넓은 축면에서 전후축과 좌심실축사이의 각도($Angle_{AP-LV}$), 전후축과 좌심실 중앙사이 최단거리($D_{AP-MidLV}$), 및 전후축과 좌심실첨부사이 최단거리($D_{AP-Apex}$)를 측정하였다. 대상환자 중 87명(96.7%)에서는 앙와위에서 좌심실이 전후축의 좌측에 위치하였다. 좌측으로 기울인 영상에서의 기울림 각도는 $43.4{\pm}11.0^{\circ}$였다. $D_{AP-MidLV}$$D_{AP-Apex}$는 좌측 기울린 위치에서 의미있게 길었지만 (p<0.001), AngleAP-LV는 두 자세 사이에 비슷했다. 심장정지인 임신부에서 좌측으로 기울림은 흉부압박의 심장펌프 효과를 떨어뜨릴 수도 있다.

웨어러블 근전도 디바이스 결합형 스마트의류 개발 및 성능평가 (Development and Evaluation of Wearable Smart Clothing for Combined EMG Devices)

  • 이소정;김혜림;정원영
    • 한국의류산업학회지
    • /
    • 제25권2호
    • /
    • pp.210-220
    • /
    • 2023
  • Recently, smart wearable products, including electromyography (EMG) measurement devices and clothing, have been developed to monitor users' exercise levels, muscle activation, and muscle balance more effectively during fitness activities. However, technical and socioeconomic barriers, such as flexibility and durability, still pose challenges in terms of comfort, ease of wear, and wearability of smart clothing, which includes devices and circuits. To address these issues, this study developed a wearable EMG device integrated with clothing to collect valid EMG signals from desired muscles while maintaining comfort, functionality, and ease of wear. After deriving a combined structure that could stably position the wearable device within the clothing, a prototype was manufactured and evaluated for fit, compression, comfort, and exercise comfort test by ten participants (height = 176.2 cm, weight = 76.4 kg, chest circumference = 101.2 cm). The study found that the prototype had smaller circumferences around the chest, waist, and abdomen compared to commercial products, resulting in lower ratings for wearing comfort and ease of wear. However, the prototype received high ratings for fitting, pressure, and the exercise comfort test. Valid signals were obtained when the EMG device was combined to the prototype for the rectus femoris muscle, indicating stable positioning of the device during exercise.

심폐소생술 시 아이젤의 고정 방법에 따른 환기량의 변화 비교: 시뮬레이션 마네킨을 이용한 연구 (Comparison of changes in ventilation volume according to fixation method of I-gel during cardiopulmonary resuscitation: a study using a simulated manikin)

  • 김선태;신상열;최정우
    • 한국응급구조학회지
    • /
    • 제25권3호
    • /
    • pp.7-16
    • /
    • 2021
  • Purpose: The I-gel device is Korea's most frequently used airway management method during pre-hospital cardiopulmonary resuscitation (CPR). This study aimed to compare changes in ventilation volume according to the fixation method with a simulated manikin. Methods: We placed I-gel into an advanced life support simulator and compared tape and band fixation conditions. CPR was performed according to the 2020 Korean CPR guidelines, using a mechanical chest compression device and an adult bag. The positional shift of I-gel and the ventilation volume of the simulated manikin were measured after performing CPR for 20 minutes. Five trials were carried out in each setting. Statistical analysis was carried out with SPSS 27.0. P < .05 was considered significant. Results: Positional shift after 20 minutes of CPR was as follows: tape fixation, 7.2 ± 0.2 mm; band fixation, no change, indicating a significant difference between the two groups (p=.003). The mean ventilation volume was tape fixation, 482.63 ± 30.84 mL; band fixation, 544.96 ± 22.98 mL, showing a significant difference (p=.002). Conclusion: When using the I-gel during pre-hospital CPR, using a band-type fixing device with elasticity rather than fixing the tape provides stable and appropriate ventilation by maintaining the fixed position.

위치에 따라 이동하는 종괴를 포함한 공동으로 진행된 비소세포폐암에 동반된 폐렴 (A Case of Pulmonary Gangrene Associated with Obstructive Pneumonia Due to Non-small Cell Lung Carcinoma)

  • 김성준;엄태찬;문귀애;김필호;김상현;정병오;이혁표;김주인;염호기;최수전
    • Tuberculosis and Respiratory Diseases
    • /
    • 제46권4호
    • /
    • pp.591-595
    • /
    • 1999
  • 저자들은 비소세포폐암으로 인한 폐쇄성폐렴에 동반된 림프절종대의 혈관압박에 의해서 발생한 폐괴저를 수술적 치료로 호전시킨 1예를 경험하였기에 문헌고찰과 함께 보고하는 바이다.

  • PDF