• Title/Summary/Keyword: Chemosensor

Search Result 99, Processing Time 0.022 seconds

A Triple-Probe Channel NO2S2-Macrocycle: Synthesis, Sensing Characteristics and Crystal Structure of Mercury(II) Nitrate Complex

  • Lee, Ji-Eun;Choi, Kyu-Seong;Seo, Moo-Lyong;Lee, Shim-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.2031-2035
    • /
    • 2010
  • A triple-probe channel type chemosensor based on an $NO_2S_2$-macrocycle functionalized with phenyltricyanovinyl group was synthesized and its sensing characteristics were examined. The pink-red solution of L changed selectively to pale yellow upon addition of $Hg^{2+}$. The selective fluorometric response of L to all the tested metal ions was studied. The results showed that a large enhancement of the fluorescence of L was observed only in the case of $Hg^{2+}$. In addition, L showed large anodic shift (~ 0.3 V) for the addition of excess $Hg^{2+}$. Through above three observed results by the different techniques, we confirmed that the proposed chemosensor acts as the multiple-probe channel sensing material. The crystal structure of mercury(II) nitrate complexs of L which shows a 1-D polymer network with a formula $[Hg_2(L)_2(NO_3)_2({\mu}-NO_3)_2]_n$ was also reported.

Salicylimine-Based Colorimetric and Fluorescent Chemosensor for Selective Detection of Cyanide in Aqueous Buffer

  • Noh, Jin Young;Hwang, In Hong;Kim, Hyun;Song, Eun Joo;Kim, Kyung Beom;Kim, Cheal
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.7
    • /
    • pp.1985-1989
    • /
    • 2013
  • A simple colorimetric and fluorescent anion sensor 1 based on salicylimine showed a high selectivity and sensitivity for detection of cyanide in aqueous solution. The receptor 1 showed high selectivity toward $CN^-$ ions in a 1:1 stoichiometric manner, which induces a fast color change from colorless to orange and a dramatic enhancement in fluorescence intensity selectively for cyanide anions over other anions. Such selectivity resulted from the nucleophilic addition of $CN^-$ to the carbon atom of an electron-deficient imine group. The sensitivity of the fluorescence-based assay (0.06 ${\mu}M$) is below the 1.9 ${\mu}M$ suggested by the World Health Organization (WHO) as the maximum allowable cyanide concentration in drinking water, capable of being a practical system for the monitoring of $CN^-$ concentrations in aqueous samples.

Determination of Mercury Ion in Contaminated Soil by Rhodamine B Hydrazide (형광화학센서를 이용한 용출기반 토양 수은 오염조사)

  • Kim, Kyungtae;Park, Junboum
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.3
    • /
    • pp.1-5
    • /
    • 2016
  • Rhodamine B Hydrazide as a novel fluorescent and colorimetric probe exhibiting remarkably selective fluorescence enhancement toward Hg2+ ion over other 16 metal ions is herein introduced. The probe reacts with Hg2+ ion followed by its spirolactam ring-opening to give a remarkable enhancement of absorption maximum at 550 nm as well as an enhanced fluorescence intensity at 580 nm in aqueous media. Upon titration with Hg2+ ion in various concentration of 10~200 uM, we found that the probe shows a marked color change from colorless to pink, enabling naked-eye detection toward mercury ion. In addition, in the presence of Hg2+ ion, the probe gave rise to change from non-florescence to strong orange fluorescence (Off-On) with a good linearity of R2=0.97. This preliminary results demonstrate that the fluorescent chemosensor we herein introduced can open a new strategy for marked selective and sensitive detection of mercury ions in contaminated soil containing various metal ions.

A New Rhodamine B Derivative As a Colorimetric Chemosensor for Recognition of Copper(II) Ion

  • Tang, Lijun;Li, Fangfang;Liu, Minghui;Nandhakumar, Raju
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.11
    • /
    • pp.3212-3216
    • /
    • 2010
  • A new rhodamine-based sensor 1 was designed and synthesized by incorporating rhodamine B and benzimidazole moieties. Sensor 1 exhibits high selectivity and sensitivity to $Cu^{2+}$ in $CH_3CN$-water solution (HEPES buffer, pH = 7.0) with an obvious color change from colorless to pink. Other metal ions such as $Hg^{2+}$, $Ag^+$, $Pb^{2+}$, $Sr^{2+}$, $Ba^{2+}$, $Cd^{2+}$, $Ni^{2+}$, $Co^{2+}$, $Fe^{2+}$, $Mn^{2+}$, $Cu^{2+}$, $Zn^{2+}$, $Ce^{3+}$, $Mg^{2+}$, $K^+$ and $Na^+$ had no such color change and have no significant influence on $Cu^{2+}$ recognition process. The interaction of $Cu^{2+}$ and sensor 1 was proven to adopt a 1:1 binding stoichiometry and the recognition process is reversible.

Synthesis and Properties of Rhodamine Dye Sensor Material toward detection Response (진단감응 로다민 색소센서재료 합성 및 특성 분석)

  • Kim, Hyung-Joo;Lee, Do-Hyun;Son, Young-A
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.11a
    • /
    • pp.34-34
    • /
    • 2011
  • Recently, people have concerned about environmental pollution. This environmental pollution occur due to many reasons such as heavy metal ions and anions. In this regard, many researchers have studied organic materials to monitor above reasons to protect environmental pollution. One of the organic materials for this function is chemosensor. This chemosensor has been studied and reported about monitoring toxic heavy metal ions and anions. In this study, the dye sensor was designed and synthesized through reaction of Rhodamine 6G and 1,3-Indanedion. this dye sensor selective detected $Hg^{2+}$ metal ions while showing red color absorption and yellowish-green strong fluorescence emission compared to other heavy metal ions such as $Cu^{2+}$, $Hg^{2+}$, $Ag^{2+}$, $Zn^{2+}$, $Fe^{2+}$ and $Fe^{3+}$. In this regard, we anticipated that this dye senosr can provide an significant material for monitoring mercury which cause environmental pollution. Thus, We investigated detailed properties of this dye sesnor with using UV-Vis absorption and fluorescent spectrophotometer, Job's plot method for metal binding complex, computational simulated calculation named Material Studio 4.3 suite to approach for electron distribution and HOMO/LUMO.

  • PDF

Heavy Metal Ion Detection in Living Cell Using Fluorescent Chemosensor (형광화학센서를 이용한 살아있는 세포 내에서의 중금속이온검출)

  • Kwon, Pil-Seung;Kim, Jin-Kyung;Kim, Jong-Wan
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.4
    • /
    • pp.451-459
    • /
    • 2010
  • The fluorescence detection of intracellular metal ions are high interest in the fields of organic molecular chemistry and cellular biology. This study was purposed to detection for mercury and zinc in the cell using fluorescent chemosensor (FS). FS exhibits a weak fluorescence, but emits strong fluorescence upon Zn$^{2+}$ complexation. The increased fluorescence of the 2FS/Zn$^{2+}$ can be quenched completely by addition of only 1 equiv of Hg$^{2+}$ with the formation of complex FS-Hg$^{2+}$. Four cell lines (LLC-MK2, Hela, HT29 and AMC-HN3) were used for fluorescence imaging by confocal microscope. The cell viability MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay was evaluated after cell treatment of FS, Zn$^{2+}$, FS-Zn$^{2+}$, Hg$^{2+}$ on LLC-MK2 cell line. The cytotoxicity of FS was showed to viability over 80%. This study has shown that FS can be detected for selective imaging of Zn$^{2+}$ and Hg$^{2+}$ in living cells.

Fluorescence Sensing Properties of Thiazolobenzo-crown Ether Incorporating Coumarin

  • Lee, Sang-Hoon;Helal, Aasif;Kim, Hong-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.3
    • /
    • pp.615-619
    • /
    • 2010
  • A new coumarin-thiazolobenzo-crown ether based fluorogenic chemosensor BTC (1) was reported. The ion-selective binding properties of 1 with different alkali, alkaline earth metals and transitional metals were investigated in an ethanol-DMSO system. BTC (1) showed the highest binding constant toward $Hg^{2+}$ over $Ag^+$, $Pb^{2+}$ and $Cu^{2+}$.