• Title/Summary/Keyword: Chemical test

Search Result 4,775, Processing Time 0.051 seconds

A Round Robin Study of Solid Content Test and Applicability Estimation of FT-IR Analysis for Chemical Admixtures (다자비교시험을 통한 화학혼화제 고형분량 시험법의 신뢰성 및 FT-IR 분석에 대한 효용성 평가)

  • Kim, Jin-Cheol;Yoo, Hyeok-Jin;Kim, Hong-Sam;Park, Ko-Eun
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.6
    • /
    • pp.695-703
    • /
    • 2015
  • Acceptance criteria for chemical admixtures of cement concrete were investigated in domestic and international specifications. The reliability was verified for solid content test method of chemical admixture examined statistical analysis by round robin test. The applicability of FT-IR spectroscopy for qualitative measurement of multi-compound chemical admixtures verified. From solid content experimental results, outlier analysed using Cochran, Grubbs and Dickson's Q test. Repeatability and reproducibility standard deviation for solid content results showed 0.25 and 0.098% respectively according to KS A ISO 5725-2 procedure, it can be confirmed reliability of test methods. FT-IR spectrum of liquefied or oven-dried chemical admixtures condition showed big differences. It is needed that the FT-IR analysis is performed on dry material. However there's no difference with the applicability of FT-IR spectroscopy for multi-compound chemical admixtures. So the utility of method analysis could not identify.

Failure Analysis on Scale Formation of Thermostat Housing and Development of Accelerated Test Methodology (써모스타트 하우징의 침전물 생성에 관한 고장분석 및 가속시험법 개발)

  • Cho, In-Hee;Hyung, Sin-Jong;Choi, Kil-Yeong;Weon, Jong-Il
    • Applied Chemistry for Engineering
    • /
    • v.20 no.2
    • /
    • pp.177-185
    • /
    • 2009
  • The failure analysis of scales deposited on automotive thermostat housing has been carried out. Observations using energy dispersive spectroscopy and electron probe micro analyzer indicate that the main components of scales are some of additives of coolant used. For a detailed investigation of organic matters pyrolysis-GC/MS is employed. The result shows that the main organic component is benzoic acid and furthermore, a small amount of acetophenone, benzene and phenyl group is detected. Based on the results of failure analysis performed, the scales on automotive thermostat housing appear due to the deposition of coolant components, followed by crevice corrosion, into gap between housing and rubber horse. New accelerated test methodology, which could mimic the scale formation and the crevice corrosion on thermostat housing, is developed considering the above results. In order to reproduce the real operating conditions, the accelerating factors, i.e. temperature and humidity, are changed and programmed. The reproducibility of the accelerated test proposed is confirmed after analyzing the scales obtained from the accelerated test.

Ecotoxicological Evaluation of Synthetic Surfactant (합성세제의 생태독성 평가)

  • 최병기;홍사욱;한상욱
    • Environmental Analysis Health and Toxicology
    • /
    • v.9 no.3_4
    • /
    • pp.91-101
    • /
    • 1994
  • In order to evaluate the ecotoxicological harzardousness of synthetic surfactants on Han river, Jung-ryang and Jin-Wi stream, we used the Ecotoxicological Risk Quotient (ERQ). The chemical harzardousness is evaluated by the balance of the toxicity and concentration in the environment.. Then, ERQ is defined as follows; ERQ = - log ( Concentration in the environment / Effective concentration in the test ) ERQ of chemical is a logtrighmic value of ratio of a chemical concentration and the toxicity in the laboratory. In case of small ERQ, tie chemical harzardousness is high. If ERQ equals O, the same biological effect as in the laboratory test will be observed in the enviromment by the chemicals. ERQ values of the chemicals were calculated using the maximum concentration in water environment which were cited from the annual report by our ministry of environment, and EC$_{50}$ of Daphnia magna (water flea; acute immobilization test) LC$_{50}$ of Oryzias latipes (fish; acue toxicity test) and EC$_{50}$ of chlorella vulgaris (alga; growth inhibition test), which were taken from the annual report of "Chemical in environment" by Japan EA. Liner alkylbenzene sulfonate (determined to MBAS) showed the high average values with more than 2.0 to three species in Han river and Jin-wi stream, and these results mean to be favorable to environmental safety. The areas of Jung-ryang stream were polluted, as the average values of ERQ were less than 2.0 with equal to three species, and attention should be paid. Therefore, they must be inspected again because their concentration in the environment may have changed during that period. The chemical harzardousness can be numerated with ERQ, and it can be a help to find the chemicals that should be kept under observation and to see whether the chemical pollution is improved or worsened. The determination of the chemical concentration in the environment and toxicity are essential for the effective use of ERQ.se of ERQ.

  • PDF

A Study of Recombinant Human Interferon $\beta$(LB00013) for Primary Eye and Skin Irritation in Rabbits

  • Park, Jong-Il;Bae, Ju-Hyun;Suh, Jeong-Eun;Jeong, Tae-Cheon;Shin, Ho-Chul;Han, Sang-Seop
    • Toxicological Research
    • /
    • v.12 no.1
    • /
    • pp.87-91
    • /
    • 1996
  • LB00013, a newly developed recombinant human Interferon $\beta$, was tested for primary eye and skin irritation in male New Zealand White rabbits. In the primary eye irritation test, 0.1 ml of a solution of LB00013 was instilled into the eye. In the rinsing group, the eye was washed with water at 30 seconds after instillation. No reaction was produced at the cornea, iris and conjunctivae by LB00013. In the primary skin irritation test, LB00013 was applied to the back of rabbits for 24 hours. Primary irritation index was "0" in test and control sites of all animals. Thus LB00013 was evaluated as a non-irritant on the basis of the criteria of Draize et al. (1944).l. (1944).

  • PDF

A STUDY ON THE RECOMBINANT HUMAN INTERFERON ${\alpha}$A(LBD-007) FOR PRIMARY EYE AND SKIN IRRITATION IN RABBITS

  • Park, Jong-Il;Kim, Sung-Hoon;Han, Sang-Seop;Roh, Jung-Koo
    • Toxicological Research
    • /
    • v.9 no.1
    • /
    • pp.119-123
    • /
    • 1993
  • LBD-007, a newly developed recombinant human interferon ${\alpha}$A, was tested for primary eye and skin irritation in male New Zealand White rabbits. In the primary eye irritation test, 0.1ml of a solution of LBD-007 was instilled into the eye. In rinsing group, the eye was washed with water 30 seconds after instillation. No reaction was observed at the cornea, iris and conjunctivae by LBD-007. In the primary skin irritation test, LBD-007 was applied to the back of rabbits for 24 hours. Primary irritation index was "0" in test and control sites of all animals. Thus LBD-007 was evaluated as a non-irritant on the basis of the criteria of Draize et al.,(1994).

  • PDF

Development of chemical conversion coating process for Mg-Al alloy and its anti-corrosion property (마그네슘-알루미늄 합금의 화성처리 공정 개발과 그 내식성 평가)

  • Kim, Seong-Jong
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.265-266
    • /
    • 2006
  • The chemical conversion coating formed on magnesium alloy investigated for low cost and harmless in environment by using the colloidal silica as the main component. The film formed in 298 K is thick, the film, which was thought combination of Si-O, was formed. The film formed in 313 K is thinner than that in 298 K. The quantity of film formed at high temperature such as 333 K and 353 K is smaller than dissolved quantity. At the anodic polarization experiment, corrosion resistance in sealing by hot water after chemical conversion treatment in basic solution condition get worse than that in comparison with basic solution condition. In salt spray test, the ratio of black rust on specimen that did not conducted chemical conversion treatment was five times or more compared with those of chemical conversion treated specimen. The film thickness of chemical conversion coating produced by alkali treatment process is thinner than in comparison with that of specimen produced in basic chemical conversion treatment solution condition. It is thought, however, that it showed good corrosion resistance during salt spray test because the area of microcracks is small.

  • PDF

Antimutagenic Effects of Ginsenoside Rb$_1$, Rg$_1$ in the CHO-K1 Cells by Benzo[a]pyrene with Chromosomal Aberration Test and Comet Assay

  • Kim, Jong-Kyu;Kim, Soo-Jin;Rim, Kyung-Taek;Cho, Hae-Won;Kim, Hyeon-Yeong;Yang, Jeong-Sun
    • Molecular & Cellular Toxicology
    • /
    • v.5 no.2
    • /
    • pp.126-132
    • /
    • 2009
  • The usage and types of chemicals are advancing, specializing, large-scaled increasing, and new chemical exposed workers are concerning to occupational disease. The generation of reactive oxygen in the body from carcinogen, mutation and DNA damage in cancer is protected by natural antioxidants (phytochemicals) with antimutagenic effect. There were many reports of ginsenoside Rb$_1$, Rg$_1$ grievances of the genetic mutation to suppress the effect confirm the genetic toxicity test with chromosomal aberration test and the Comet (SCGE) assay confirmed the suppression effect occurring chromosomal DNA damage. We had wanted to evaluate the compatibility and sensitivity between the chromosomal aberration (CA) test and the Comet assay. We used the CA test and Comet assay to evaluate the anti-genotoxicity of ginsenoside Rb$_1$ and Rg$_1$, in CHO-K1 (Chinese hamster ovary fibroblast) cell in vitro, composed negative control (solvent), positive control (benzo[a]pyrene), test group (carcinogen+variety concentration of ginsenoside) group. The positive control was benzo[a]pyrene (50 $\mu$M), well-known carcinogen, and the negative control was the 1 % DMSO solvent. The test group was a variety concentration of ginsenoside Rb$_1$, Rg$_1$ with 10$^{-8}$%, 10$^{-6}$%, 10$^{-4}$%, 10$^{-2}$%, 1%, 10%. In chromo-somal aberration test, we measured the number of cells with abnormally structured chromosome. In Comet assay, the Olive tail moment (OTM) and Tail length (TL) values were measured. The ratio of cell proliferation was increased 8.3% in 10$^{-8}$%, 10$^{-6}$%, 10$^{-4}$%, 10$^{-2}$%, 1%, 10% Rb$_1$ treated groups, and increased 10.4% in 10$^{-10}$%, 10$^{-8}$%, 10$^{-6}$%, 10$^{-4}$%, 10$^{-2}$%, 1% Rg$_1$ treated groups. In the CA test, the number of chromosomal aberration was decreased all the Rb$_1$ and Rg$_1$ treated groups. In the Comet assay, the OTM values were decreased in all the Rb$_1$ and Rg$_1$ treated groups. To evaluate the compatibility between CA and Comet assay, we compared the reducing ratio of chromosomal abnormalities with its OTM values, it was identified the antimutagenicity of ginsenoside, but it was more sensitive the CA test than the Comet assay. Ginsenoside Rb$_1$ and Rg$_1$ significantly decrease the number of cells with chromosomal aberration, and decrease the extent of DNA migration. Therefore, ginsenoside Rb$_1$, Rg$_1$ are thought as an antioxidant phytochemicals to protect mutagenicity. The in vitro Comet assay seems to be less sensitive than the in vitro chromosomal aberration test.

Physical Aging Mechanism of Epoxy Coating by Hygrothermal Cycling Test

  • Kim, Min Hong;Lee, Gun Dae;Park, Jin Hwan
    • Corrosion Science and Technology
    • /
    • v.5 no.5
    • /
    • pp.177-180
    • /
    • 2006
  • The anticorrosive performance of epoxy coating was examined by using the hygrothermal cyclic test and the degradation mechanism of the coating was investigated by using the AC impedance method. The relationship between the results obtained from different tests was studied. It was revealed that the hygrothermal cyclic test can be used as an effective acceleration test for the degradation of organic coating. It was also found in hygrothermal cyclic test that the epoxy coatings have the resistance to stresses at some extent. The degradation of organic coating seems to be caused by the decrease of resistance of coating and the increase of both capacitance and free volume in the organic coating.

A Study on the Methyl Salicylate Dispersion in the Vicinity of Obstacles by Wind Tunnel Test (아음속 풍동을 이용한 구조물 형상 변화에 따른 살리실산메틸 확산 유동 연구)

  • Hong, Chang-Ki;Uhm, Han-Sup;Choi, Seung-Ki;Kim, Youn-Jea
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.6
    • /
    • pp.69-73
    • /
    • 2014
  • To predict flow fields and chemical agent dispersion in urban area, wind tunnel experiments was performed. The agent was adopted MS (methyl salicylate) because the real chemical agent is unsafe. The exact concentration of methyl salicylate was generated by the commercial gas generator (STI-2500) and three different obstacle shapes were applied (i.e., rectangular, cylinder and pyramid). The concentration was measured with the qualified ion mobility sensor and gas chromatography. The data necessary for virtual test method of the real chemical agent were obtained.