• Title/Summary/Keyword: Chemical imaging

Search Result 365, Processing Time 0.031 seconds

Serial Block-Face Imaging by Field Emission Scanning Electron Microscopy (전계방사형 주사전자현미경에 의한 연속블록면 이미징)

  • Kim, Ki-Woo
    • Applied Microscopy
    • /
    • v.41 no.3
    • /
    • pp.147-154
    • /
    • 2011
  • Backscattered electrons (BSE) are generated at the impact of the primary electron beam on the specimen. BSE imaging provides the compositional contrast to resolve chemical features of sectioned block-face. A focused ion beam (FIB) column can be combined with a field emission scanning electron microscope (FESEM) to ensure a dual (or cross)-beam system (FIB-FESEM). Due to the milling of the specimen material by 10 to 100 nm with the gallium ion beam, FIB-FESEM allows the serial block-face (SBF) imaging of plastic-embedded specimens with high z-axis resolution. After contrast inversion, BSE images are similar to transmitted electron images by transmission electron microscopy. As another means of SBF imaging, a specialized ultramirotome has been incorporated into the specimen chamber of FESEM ($3View^{(R)}$). Internal structures of plastic-embedded specimens can be serially revealed and analyzed by $3View^{(R)}$ with a large field of view to facilitate three-dimensional reconstruction. These two SBF approaches by FESEM can be employed to unravel spatial association of (sub)cellular entities for a comprehensive understanding of complex biological systems.

Proton Magnetic Resonance Chemical Shift Imaging(1H-CSI)-directed Stereotactic Brain Biopsy (양성자 화학적 이동영상기법(1H-CSI)을 이용한 정위적 뇌생검)

  • Chang, Kyung-Sool;Son, Byung-Chul;Kim, Moon-Chan;Choi, Byung-Gil;Kim, Euy-Neying;Kim, Bum-Soo;Choe, Bo-Young;Baik, Hyun-Man;Hong, Yong-Kil;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.12
    • /
    • pp.1606-1611
    • /
    • 2000
  • Objective : To obtain more reliable sample in stereotactic biopsy, authors adopted proton chemical shift imaging ($^1H$-CSI)-directed biopsy. Until now, proton single voxel spectroscopy($^1H$-SVS) technique has been reported as a technique using metabolic information in stereotactic biopsy. The authors performed $^1H$-CSI with a stereotactic headframe in place and evaluated the pathologic results obtained from local metabolic information through $^1H$-CSI. Methods : $^1H$ CSI-directed stereotactic biopsy was performed in four patients. $^1H$-CSI and conventional Gd-enhancement stereotactic MRI was done simultaneously after application of the stereotatic frame. After reconstruction of metabolic maps of NAA/Cr, Cho/Cr, and Lactate/Cr ratios, the focal areas of increased Cho/Cr ratios and decreased NAA/Cr ratios were selected for target sites in the MR images Results : There was no difficulty in performing $^1H$-CSI with the stereotactic headframe in place. In pathologic examinations, the samples taken in area of increased Cho/Cr ratios and decreased NAA/Cr ratios showed the features of increased cellularity, mitoses and cellular atypism, thus facilitated the diagnosis. The pathologic samples taken from the area of increased Lactate/Cr ratios showed prominent feature of necrosis. Conclusion : $^1H$-CSI was feasible with stereotactic head frame in place. The final pathologic results obtained in our samples were concordant with the local metabolic informations from $^1H$-CSI. Authors believe that $^1H$ CSI-directed stereotactic biopsy may provide us advantages in obtaining more reliable tissue specimen in stereotactic biopsy.

  • PDF

Simultaneous Detection of Biomolecular Interactions and Surface Topography Using Photonic Force Microscopy

  • Heo, Seung-Jin;Kim, Gi-Beom;Jo, Yong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.402.1-402.1
    • /
    • 2014
  • Photonic force microscopy (PFM) is an optical tweezers-based scanning probe microscopy, which measures the forces in the range of fN to pN. The low stiffness leads proper to measure single molecular interaction. We introduce a novel photonic force microscopy to stably map various chemical properties as well as topographic information, utilizing weak molecular bond between probe and object's surface. First, we installed stable optical tweezers instrument, where an IR laser with 1064 nm wavelength was used as trapping source to reduce damage to biological sample. To manipulate trapped material, electric driven two-axis mirrors were used for x, y directional probe scanning and a piezo stage for z directional probe scanning. For resolution test, probe scans with vertical direction repeatedly at the same lateral position, where the vertical resolution is ~25 nm. To obtain the topography of surface which is etched glass, trapped bead scans 3-dimensionally and measures the contact position in each cycle. To acquire the chemical mapping, we design the DNA oligonucleotide pairs combining as a zipping structure, where one is attached at the surface of bead and other is arranged on surface. We measured the rupture force of molecular bonding to investigate chemical properties on the surface with various loading rate. We expect this system can realize a high-resolution multi-functional imaging technique able to acquire topographic map of objects and to distinguish difference of chemical properties between these objects simultaneously.

  • PDF

MRI Artifacts

  • 최순섭
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.51-57
    • /
    • 1997
  • MRI의 artifact는 대부분 신호의 부호화 방향에 따라서 방향성을 가지는데, 이를 요약해보면, 위상부호화 방향의 artifact에는 motion artifact, flow artifact, RF noise등이 있고, 주파수 부호화 방향의 artfact는 susceptibility artfact, chemical shift artifact, central line artifact등이 있으며, 양방향 모두 생길수 있는 것은 Aliasing artifact와 Gibb's phenomenon이고, 전체적으로 영샹의 질을 떨어뜨리는 것은 susceptibility artifact, Eddy current, cross talk등이 있다. 이런 artifact는 대부분은 MRI 자체의 물리적 특성에 다소간 기인하므로, artifact가 없는 양호한 영상을 얻기 위해서는 MRI의 설치 단계부터 관심이 필요하고, MRI의 기본원리와 다양한 artifact에 대해 이해함으로써, 제거 가능한 artifact는 제거하여 양질의 영상을 만들고 판독시의 오류를 피할 수 있도록 해야할 것이다.

  • PDF

Atlantoaxial instability with hydrocephalus in a dog

  • Jeong, Seong Mok;Choi, Hojung
    • Korean Journal of Veterinary Research
    • /
    • v.46 no.1
    • /
    • pp.67-70
    • /
    • 2006
  • An 8-month-old 3.15 kg female Cocker-spaniel with history of ataxia referred to the Veterianary Medical Teaching Hospital, Chungnam National University. There were no abnormalities in CBC and serum chemical analysis. Agenesis of dens was found on dorsoventral view in cervical radiography. Compressed cervical spinal cord and enlarged cerebral ventricle were observed in magnetic resonance imaging. It was diagnosed as atlantoaxial instability with hydrocephalus. For conservative therapy, neck brace was applied and diuretics and prednisolone were administered. The dog's ataxia became better gradually.

A Study on MR Imaging Method for The Patient with Inserting Shoulder Joint Suture Anchor (견관절 삽입술을 시행한 환자의 자기 공명 영상법에 관한 연구)

  • Park, Eui-Cheol;Bae, Seok-Hwan;Ryu, Yeun-Chul;Park, Young-Joon;Kim, Yong-Gwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.513-519
    • /
    • 2021
  • Metallic suture anchors are very useful and common fixation devices that are inserted into the target bone to sustain the tendon of a patient with musculus supraspinatus tendon ruptures. On the other hand, the presence of a metallic material prosthesis, such as a metal suture anchor, causes severe MR imaging artifacts, including field distortion, signal loss, and failure of fat suppression. The difference in magnetic susceptibility between metal and other organic materials causes magnetic field distortion surrounding the prosthesis. The resulting magnetic field inhomogeneity makes the images with a lower signal-to-noise ratio and distortion. For a patient with a suture anchor implanted, MR imaging is the golden standard for determining the postoperative prognosis, and a fat-saturation sequence is one of the imaging methods most affected by metal-induced artifacts. In this study, three fat-saturation sequences were compared. Artifact quantification and contrast comparison between the supraspinatus tendon and the surrounding muscle were presented. The images obtained using the STIR pulse sequence showed fewer susceptibility artifacts and better visibility in the supraspinatus tendon and the tissue area. Therefore, the STIR sequence is the most appropriate fat-saturation imaging method for patients with a metallic prosthesis.

Quantitative Ultrasound Radiofrequency Data Analysis for the Assessment of Hepatic Steatosis in Nonalcoholic Fatty Liver Disease Using Magnetic Resonance Imaging Proton Density Fat Fraction as the Reference Standard

  • Sun Kyung Jeon;Jeong Min Lee;Ijin Joo;Sae-Jin Park
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1077-1086
    • /
    • 2021
  • Objective: To investigate the diagnostic performance of quantitative ultrasound (US) parameters for the assessment of hepatic steatosis in patients with nonalcoholic fatty liver disease (NAFLD) using magnetic resonance imaging proton density fat fraction (MRI-PDFF) as the reference standard. Materials and Methods: In this single-center prospective study, 120 patients with clinically suspected NAFLD were enrolled between March 2019 and January 2020. The participants underwent US examination for radiofrequency (RF) data acquisition and chemical shift-encoded liver MRI for PDFF measurement. Using the RF data analysis, the attenuation coefficient (AC) based on tissue attenuation imaging (TAI) (AC-TAI) and scatter-distribution coefficient (SC) based on tissue scatter-distribution imaging (TSI) (SC-TSI) were measured. The correlations between the quantitative US parameters (AC and SC) and MRI-PDFF were evaluated using Pearson correlation coefficients. The diagnostic performance of AC-TAI and SC-TSI for detecting hepatic fat contents of ≥ 5% (MRI-PDFF ≥ 5%) and ≥ 10% (MRI-PDFF ≥ 10%) were assessed using receiver operating characteristic (ROC) analysis. The significant clinical or imaging factors associated with AC and SC were analyzed using linear regression analysis. Results: The participants were classified based on MRI-PDFF: < 5% (n = 38), 5-10% (n = 23), and ≥ 10% (n = 59). AC-TAI and SC-TSI were significantly correlated with MRI-PDFF (r = 0.659 and 0.727, p < 0.001 for both). For detecting hepatic fat contents of ≥ 5% and ≥ 10%, the areas under the ROC curves of AC-TAI were 0.861 (95% confidence interval [CI]: 0.786-0.918) and 0.835 (95% CI: 0.757-0.897), and those of SC-TSI were 0.964 (95% CI: 0.913-0.989) and 0.935 (95% CI: 0.875-0.972), respectively. Multivariable linear regression analysis showed that MRI-PDFF was an independent determinant of AC-TAI and SC-TSI. Conclusion: AC-TAI and SC-TSI derived from quantitative US RF data analysis yielded a good correlation with MRI-PDFF and provided good performance for detecting hepatic steatosis and assessing its severity in NAFLD.

Liquid Crystal-based Imaging of Biomolecular Interactions at Roller Printed Protein Surfaces

  • Park, Min-Kyung;Jang, Chang-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1223-1227
    • /
    • 2010
  • In this study, the orientational behavior of thermotropic liquid crystals (LC) supported on a film of protein receptors was examined. Avidin was roller printed and covalently immobilized onto the surface of gold using NHS/EDC chemistry. The orientation of nematic 4-cyano-4'-pentylbiphenyl (5CB) was found to be parallel to the plane of the printed avidin surface before incubation with a solution of biotin. However, protein-receptor complexation induced a random orientation of 5CB, where protein-receptor complexes disturbed the nanoscale topography of the printed protein surface. Atomic force microscopy and ellipsometry was used to confirm printing and the specific interaction of proteins. These results demonstrate that the combination of LC and roller printing can be used to detect specific interactions between biomolecules by manipulating the orientational behavior of LC to the printed protein surfaces.

Tip-Enhanced Raman Scattering with a Nanoparticle-Functionalized Probe

  • Park, Chan-Gyu;Kim, Ju-Young;Lee, Eun-Byoul;Choi, Han-Kyu;Park, Won-Hwa;Kim, Jin-Wook;Kim, Zee-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.5
    • /
    • pp.1748-1752
    • /
    • 2012
  • We carried out the tip-enhanced Raman scattering (TERS) with a tip that is functionalized with a Aunanoparticle (AuNP, with a diameter of 250 nm). The AuNP tip is fabricated by a direct mechanical pickup of a AuNP from a flat substrate, and the TERS signal from the AuNP tip - organic monolayer - Au thin film (thickness of 10 nm) is recorded. We find that such a AuNP-tip interacting with a thin film routinely yields signal enhancement larger than ${\sim}10^4$, which is sufficient not only for local (with detection area of ~200 $nm^2$) Raman spectroscopy, but also the nanometric imaging of organic monolayers within a reasonable acquisition time (~20 minutes/image).