• Title/Summary/Keyword: Chemical foaming agent

Search Result 57, Processing Time 0.03 seconds

An Experimental Study on the Development of Lightweight Foamed Concrete as Sandwich Panel Core (샌드위치 패널 심재용 경량기포콘크리트 개발에 관한 실험적 연구)

  • Lee, Sang-An;Chun, Woo-Young;Ko, Kwan-Ho;Kim, Wha-Jung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.557-560
    • /
    • 2008
  • This was done by analyzing the sandwich panels that are now widely used in construction work. Sandwich panels are used for diverse purposes in construction work worldwide. In Korea, polystyrene panels that have organic materials as their core material are used. These panels are thus very vulnerable to fire, with risks of core melting, sheet deformation, and hazardous gases. Accordingly, sandwich panels' fire-resistant or non-flammable properties must be secured. To solve these problems, the optimal mixing proportion of lightweight foamed concrete for the sandwich panel core was determined. A new method of doing this was introduced that is completely different from the existing method, wherein a foaming agent is added to realize lightweight concrete. For lightweight concrete, the foaming mechanisms via diverse chemical reactions were identified, H$_2$O$_2$ was added for heating in the reaction, and the concrete foaming was maximized. Through diverse experiments to determine the optimal mixing proportion of lightweight foamed concrete and to examine the filling characteristic of lightweight foamed concrete for sandwich panel cores using waste materials, the physical and mechanical properties of lightweight foamed concrete were examined.

  • PDF

Preparation and Analysis of Alkaline Powder Cleaning Agents for Steel (철강용 알칼리 분말세정제의 제조 및 세정해석)

  • Lee, Ae-Ri;Chung, Dong-Jin;Park, Hong-Soo;Im, Wan-Bin
    • Journal of the Korean Applied Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.283-288
    • /
    • 2003
  • Alkaline powder cleaning agents (APCAs) were prepared by blending of $Na_2CO_3$ tetrasodium pyrophosphate (TSPP). sodium orthosilicate (Na-OSi), Na-dioctyl sulfosuccinate (303C), Demol C, and MJU-100A (100A). The physical properties of APCAs tested with steel specimen showed the following results. The cleaning powers of APCA-6 ($Na_2CO_3$ 250g/TSPP 70g/Na-OSi 40g/303C 60g/Demol C 50g/100A 30g mixture) for press-rust preventing oil was 97% and 98% degreasing at 2wt%, $70^{\circ}C$ and $90^{\circ}C$, respectively; for Quenching oil, the cleaning power of APCA-6 was 95% degreasing at 2wt% and $70^{\circ}C$. From the results, it was ascertained that APCA-6 exhibited a good cleaning power. Also low foaming power tests proved that the APCA-6 maintained good defoaming effect.

Foaming Characteristics of Ethylene Vinyl Acetate/Styrene Vinyl Isoprene Styrene Triblock Copolymer Blend (Ethylene Vinyl Acetate / Styrene Vinyl Isoprene Styrene Triblock Copolymer 블렌드의 발포특성)

  • Heo, Jae-Young;Kim, Jin-Tae;Yoon, Jung-Sik;Yoo, Jong-Sun;Kim, Won-Ho
    • Elastomers and Composites
    • /
    • v.35 no.2
    • /
    • pp.106-114
    • /
    • 2000
  • The foam of ethylene vinyl acetate (EVA)/styrene-vinyl isoprene-styrene triblock copolymer(SVIS) blend was prepared to improve the shock-absorption and compression set characteristics at room temperature. The effects of blowing agent and blend ratio of EVA/SVIS on expansion ratio, cell structure and mechanical properties of the foam were investigated. As the SVIS content increased, the viscosity of blends was increased but the crosslinking rate was slow down, the expansion ratio was decreased. and the specific gravity was increased. At room temperature, the resilience was not affected by increasing the amount of blowing agent. The value of tan ${\delta}$ was increased by increasing the amount of SVIS. As a result, the value of compression set was decreased. This is due to the increased values of specific gravity and crosslinking density of the EVA/SVIS foam.

  • PDF

Production of Foamed Glass by Using Hydrolysis of Waste Glass (I) - Hydrolysis of Waste Glass - (폐 유리의 가수 분해반응에 의한 발포유리의 제조(I) - 폐유리의 가수분해 반응 -)

  • Lee, Chul-Tae;Lee, Hong-Gil
    • Applied Chemistry for Engineering
    • /
    • v.16 no.4
    • /
    • pp.519-526
    • /
    • 2005
  • Hydrolysis of soda-lime waste glass was investigated to test the feasibility for use of waste glass as feed material in the production of foamed glass. The soda-lime glass, such as plate glass and various bottle glasses, was effectively hydrolyzed by steam and water under high pressure. The proper condition for the hydrolysis was found to be reaction temperature of $250^{\circ}C$ and reaction time of 2 h. Under this condition, the water content of hydrated glass through hydrolysis was 7.85~10.04%, allowing successful foaming process for production of foamed glass. Using Na as the modifying agent of glass was effective in the hydrolysis by water. The highest water content of hydrated glass was obtained when weight ratio of NaOH to the glass was 0.04.

Preparation of Polyethylene Foam Sheets Crosslinked by Gamma-ray Irradiation (감마선 조사에 의하여 가교된 폴리에틸렌 발포 시트의 제조)

  • Lee, Dong-Hoon;Choi, Jun-Ho;Shim, Ki-Hyung;Jung, Chan-Hee;Hwang, In-Tae;Choi, Jae-Hak
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.211-215
    • /
    • 2012
  • In this study, crosslinked polyethylene (PE) foam sheets were prepared through gamma-ray irradiation. PE foam sheets were prepared through a foaming process using sodium bicarbonate as a blowing and foaming agent. The prepared PE foam sheets were then crosslinked through gamma-ray irradiation. The crosslinking degree was increased to 86.0% with an increase in the absorption dose. The tensile strength of the crosslinked PE foam sheets was increased with an increase in the absorption dose. However, the elongation-at-break of the crosslinked PE foam sheets was decreased. The thermal decomposition temperature of the crosslinked PE foam sheets was increased to $421.2^{\circ}C$ with an increase in the absorption dose. The SEM analysis revealed that the morphology was not changed significantly after the crosslinking through gamma-ray irradiation.

A study on selective hybrid-structure film fabricated by 355nm UV-pulsed laser processing (355nm UV 레이저를 이용한 선택적 하이브리드 구조 필름의 제작에 관한 연구)

  • Kim, Myung-Ju;Lee, Sang-Jun;Shin, Bo-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.2979-2984
    • /
    • 2015
  • This paper has presented a new foaming technology of selective hybrid-structured polymer film with expanded pores. The porous structure of closed pore was firstly fabricated by applying the 355nm UV-pulsed laser to 0.1mm thick film that was uniformly mixed with PP pellets, copper powder, and CBA (Chemical Blowing Agent). In order to expand pore size of closed-cell shape, LAMO(Laser Aided Micro pore Opening) processing was conducted to heat the copper powder, and then the bigger pore size of closed-cell more than existing pore size was successfully formed because of rapid conduction of heated metal powder. From the experimental results, various process parameters such as laser fluence, intensity, scan rate, spot size and density of powder and CBA were considerably considered to reveal the correlation among the pore characteristics. In the future, a function experiment will be carried out to use the hybrid film of industrial applications.

Physical Properties of Polypropylene Foam Blended with Thermally Expandable Microcapsules (열팽창캡슐 적용 발포폴리프로필렌의 물리적 특성 비교)

  • Ha, Jin Uk;Jeoung, Sun Kyung;Lee, Pyoung-Chan;Hwang, Ye Jin;Nam, Byung Kook;Han, In-Soo;Kwak, Sung Bok;Lee, Jae Yong
    • Polymer(Korea)
    • /
    • v.39 no.1
    • /
    • pp.64-70
    • /
    • 2015
  • Thermally expandable microcapsules (TEMs) can be expanded upon heating since the activation energy of liquid hydrocarbon at the core of the TEMs increased at high temperature. Due to this property, TEMs are widely used in the industry as blowing agents or light-weight fillers. In this article, chemical blowing agent and TEM were used for making polypropylene (PP) foams, and their mechanical properties were compared. Physical properties (tensile strength, impact strength etc.) of PP foams decreased with increasing the amount of blowing agents while weight of specimen decreased. However, PP foam produced with TEMs showed higher impact strength than the one with a chemical blowing agent. In order to figure out the difference of impact strength, the morphology of PP foamed was investigated. Expanding properties of TEM can be controlled by changing core back distance.

Properties of Foamed Concrete According to Types and Concentrations of Foam Agent (기포제 종류 및 희석 농도에 따른 기포 콘크리트의 특성)

  • Kim, Jin-Man;Jeong, Ji-Yong;Hwang, Eui-Hwan;Shin, Sang-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.1
    • /
    • pp.61-70
    • /
    • 2012
  • Recently, the government has been working feverously to save energy and reduce greenhouse gas emission by enacting Basic Act on Low Carbon Green Growth at the national level. Improving the insulation performance of building exterior and insulator can reduce the energy in the building sector. This study is about developing light-weight foamed concrete insulation panel that can be applied to buildings to save energy and to find the optimal condition for the development of insulation materials that can save energy by enhancing its physical, kinetic and thermal characteristics. Various experimental factors and conditions were considered in the study such as foam agent types (AES=Alcohol Ethoxy Sulfate, AOS=Alpha-Olefin Sulfonate, VS=Vegetable Soap, FP=Fe-Protein), foam agent dilution concentration (1, 3, 5%), and foam percentage (30, 50, 70%). Experiment results indicated that the surface tension of aqueous solution including foam agent, was lower when AOS was used over other foam agents. FP produced relatively stable foams in 3% or more, which produced unstable foams containing high water content and low surface tension when diluted at low concentration. Depending on foam agent types, compressive strength and thermal conductivity were similar at low density range but showed some differences at high concentration range. In addition, when concentrations of foam agent and foaming ratio increased, pore size increased and open pores are formed. In all types of foam agent, thermal conductivity were excellent, satisfying KS standards. The most outstanding performance for insulation panel was obtained when FP 3% was used.

Effect of surfactant types in aqueous cleaning agents on their physical properties, cleaning ability and oil-water separation (수계세정제의 계면활성제 종류에 따른 물성, 세정성 및 유수분리 영향 연구)

  • Park, S. W.;Cha, A. J.;Kim, H. T.;Kim, H. S.;Bae, J. H.
    • Clean Technology
    • /
    • v.9 no.1
    • /
    • pp.9-21
    • /
    • 2003
  • CFC-113 and 1,1,1-TCE which are ozone destruction substances are not used any more in the advanced countries because of Montreal protocol. MC and TCE are now used restrictively at small part of industrial fields in most of countries since they are known to be hazardous or carcinogenic materials. Thus, it is indispensible that the alternative cleaning agents which are environmental-friendly and safe, and show good cleaning ability should be developed or utilized for replacement of the halogenated cleaning agents. Aqueous cleaning agents are evaluated to be promising alternative ones among various alternatives in environmental and economical view point. This study has been carried out as a part of development program of aqueous cleaning agent. First of all, several types of surfactants which are the most important component in aqueous cleaning agents were chosen, and the physical properties, foaming ability, cleaning ability and oil-water separation efficiency of their aqueous solutions were measured and compared for selection of proper type of surfactant in aqueous cleaning agents.

  • PDF

Effect of Foaming Agent Content on the Apparent Density and Compressive Strength of Lightweight Geopolymers (발포제 함량에 따른 경량 다공성 지오폴리머의 밀도와 강도 특성)

  • Lee, Sujeong;An, Eung-Mo;Cho, Young-Hoon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.363-370
    • /
    • 2016
  • Lightweight geopolymers are more readily produced and give higher fire resistant performance than foam cement concrete. Lowering the density of solid geopolymers can be achieved by inducing chemical reactions that entrain gases to foam the geopolymer structure. This paper reports on the effects of adding different concentrations of aluminum powder on the properties of cellular structured geopolymers. The apparent density of lightweight geopolymers has a range from 0.7 to $1.2g/m^3$ with 0.025, 0.05 and 0.10 wt% of a foaming agent concentration, which corresponds to about 37~60 % of the apparent density, $1.96g/cm^3$, of solid geopolymers. The compressive strength of cellular structured geopolymers decreased to 6~18 % of the compressive strength, 45 MPa of solid geopolymers. The microstructure of geopolymers gel was equivalent for both solid and cellular structured geopolymers. The workability of geopolymers with polyprophylene fibers needs to be improved as in fiber-reinforced cement concrete. The lightweight geopolymers could be used as indoor wall tile or board due to fire resistance and incombustibility of geopolymers.