• Title/Summary/Keyword: Chemical facilities

Search Result 622, Processing Time 0.031 seconds

Characteristics of Bed Media for Reducing Odor from Livestock Facilities (축사 악취저감을 위한 바이오필터 충전재의 악취제거 특성)

  • 한원석;장동일;방승훈;이승주
    • Journal of Animal Environmental Science
    • /
    • v.9 no.2
    • /
    • pp.93-102
    • /
    • 2003
  • This study designed and constructed an experimental column far adhesion efficiency test and conducted experiment to investigate the offensive odor adhesion efficiency of filter bed materials. The offensive odor adhesion experiment was conducted using mixture of high physical adhesion efficiency material, and the fixity of deodorization microorganism of selected filter bed material was tested using ammonia exclude microorganism A4-­2 and sulfur oxidation microorganism S5­-5.2 those were cultured at the Agricultural Chemical Department of Chungnam National University, and deodorization efficiency of selected filter bed material mixture was tested. Following are summary of these tests results. 1. Amount of elimination of the offensive odor gas of ammonia and hydrogen sulfide per unit volume was 0.054 and 0.016$\ell/\textrm{cm}^3$ in rice hull, 0.01 and 0.004 $\ell/\textrm{cm}^3$ in rice straw 0.158 and 0.01 $\ell/\textrm{cm}^3$ in coconut, 0.014 and 0.02$\ell/\textrm{cm}^3$ perlite, 0.004 and 0.003$\ell/\textrm{cm}^3$ in high road ball, and 0.112 and 0.015 $\ell/\textrm{cm}^3$ in chaff of pine, respectively. 2. Amount of elimination of offensive odor gas of ammonia and hydrogen sulfide per unit volume was 0.045 and 0.014$\ell/\textrm{cm}^3$ in mixture 1, 0.079 and 0.016$\ell/\textrm{cm}^3$ in mixture 2, 0.123 and 0.017 $\ell/\textrm{cm}^3$ in mixture 3, 0.031 and 0.015$\ell/\textrm{cm}^3$ in mixture 4, 0.055 and 0.016$\ell/\textrm{cm}^3$ in mixture 5, and 0.111 and 0.020$\ell/\textrm{cm}^3$ in mixture 6, respectively. 3. The offensive odor elimination microorganism inoculated to mixture of chaff of pine(70%) and perlite(30%) showed the elimination efficiency of 99.06% and 96.61% against the ammonia and hydrogen sulfide, respectively, during 24 hours period.

  • PDF

Ecological Characteristics and Management Plan of Geumdangsil Pine Forest of Yecheon (예천 금당실 송림의 생태적 특성 및 관리방안)

  • Lee, Soo-Dong;Lee, Chan;Kim, Donwook;Kim, Jisuk
    • Korean Journal of Environment and Ecology
    • /
    • v.27 no.6
    • /
    • pp.718-732
    • /
    • 2013
  • The purpose of this study was to provide data for the basic research to found the effective conservation and management plan for the Geumdangsil Pine Forest of Yecheon designated as Natural Monument No. 469. Furthermore, this paper suggest efficient sustainable forest preservation and using. In order to achieve the sustainable forest preservation, this study was to analyse topography, land use, tree growth, soil environment, forest usage and forest management, etc. According to analysis the results, the site area is located in the flatlands where is from 130 to 140 m above sea level. The around forest was transformed into agricultural land. The 565 individuals of Pinus densiflora grows in the forest, whereas, 25 trees was cut down or died. There are signs of 25 stumps. The most of 565 trees' diameter at breast height(DBH) was centerized between 30 cm and 50 cm, moreover, the average life expectancy of trees were 85.4 years. The oldest age of tree was estimated to be 200 years. The Sample trees of rate of branch growth is from 4.3 cm to 5.1 cm per year. The middle branch which is more vigorous growth grow 24.2 cm for 3 years. Moreover, the result of soil physico-chemical properties analysis of 7 plots, 4 categories which is soil organic matter, total nitrogen, available phosphoric acid, specific electrical conductance was generally good, however, the 2 categories which is soil pH, exchangeable cation needed improvement. Currently, the site was not pressured by facilities and usage, however, there might be threaten by agriculture such as encroaching on forest. Therefore, there should establish comprehensive ecosystem management such as facility management, visitors management and operation management In this paper considered 4 fields that is ecosystem management, facility management, visitors management and operation management for sustainable management.

Studies on the Effects of Variation Methods of Rotation Irrigation Systems Affecting on the Growth, Yield of Rice Plant and its Optimum Facilities (윤환관개의 방법의 차이가 수도생육 및 수량에 미치는 영향과 그 적정시설에 관한 연구)

  • 이창구
    • Journal of the Korean Professional Engineers Association
    • /
    • v.2 no.5
    • /
    • pp.4-18
    • /
    • 1969
  • This experiment was conducted, making use of the "NONG-RlM 6", a recommended variety of rice for year of 1968. Main purposes of the experiment are to explore possibilities of: a) ways and means of saving irrigation water and, b) overcoming drought at the same time so that an increased yield in rice could be resulted in. Specifically, it was tried to determine the effects of the circulation irrigation method combined with differentiated thickness of lining upon the growth and yield of rice. Some of the major findings are summarized in the following. 1) The different thicknesses show a significant relationship with the weight of 1,000 grains. In the case of 9cm-lined plot, the grain weight is 23.5 grams, the heaviest. Next in order are 3cm-lined plot, 6cm-lined plot, control plot, and wheat straw lined-plot. 2) In rice yield, it is found that there is a considerably moderate significant relationship with both the different thickness of lining and the number of irrigation, as shown in the table. 3) There is little or no difference among different plots in terms of a) physical and chemical properties of solid, b) quality of irrigation water, c) climatic conditions, and rainfalls. 4) It is found that there is a significant relationship between differences in the method of rotation irrigation and the number of ears per hill. The plot irrigated at an interval of 7 days shows 17.4 ears and the plot irrigated at an interval of 6 days, 16.3. 5) In vinyl-treated plots, it is shown that both yield and component element are greatest in the case of the plot with hole of 3$cm/m^2$. Next in order are; the plot with a hole of 2$cm/m^2$; the plot with a hole of 1$cm/m^2$. In the case of the plot with no hole, it is found that both yield and component elements are decreased as compared to the control plot. 6) The irrigation water requirement is measured for the actual irrigation days of 72 which are the number subtracted the days of rainfall of 30 from the total irrigation days of 102. It is found that the irrigation water requirement for the un control plot is 1,590 mm, as compared to 876 mm (44.9% saved) for the 9cm-lined plot, 959mm(39.7% saved) for the 6cm-lined plot, 1,010mm (36% saved) for the 3cm-lined plot, and 1,082mm (32% saved) for the wheat straw lined plot. In the case of the rotation irrigation method, it is found that the water requirement for the plot irrigated at an interval of 8 days is 538mm (65.3% saved), as compared to 617mm (61.1% saved) for the plot irrigated at an interval of 7 days, 672mm (57.7% saved) for the plot irrigated at an interval of 6 days, 746mm (53.0% saved) for the plot irrigated at an interval of 5 days, 890mm (44.0% saved) for to plot irrigated at an interval of 4 days, and 975mm (38.6% saved) for the plot irrigated at an interval of 3 days. 7) The rate of evapo-transpiration is found 2.8 around the end of the month of July, as compared to 2.6 at the begining of August, 3.4 around the end of August, and 2.6 at the begining of September. 8) It is found that the saturaton quantity of 30 mm per day is decreased to 20mm per day through the use of vinyl covering. 9) The husking rate shows 75 per cent which is considered better.

  • PDF

Evaluation of Indoor Air Quality in a Department of Radiation Oncology Located Underground (지하에 위치한 방사선종양학과에서의 실내공기 질 평가)

  • Kim, Won-Taek;Shin, Yong-Chul;Kang, Dong-Mug;Ki, Yong-Kan;Kim, Dong-Won;Kwon, Byung-Hyun
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.243-252
    • /
    • 2005
  • Purpose: Indoor air quality (IAQ) in the radiation treatment center which is generally located underground is important to the health of hospital workers and patients treated over a long period of time. this study was conducted to measure and analyze the factors related to IAQ and subjective symptoms of sick building syndrome, and to establish the causes influencing IAQ and find a solution to the problems. Methods and Materials : Self administrated questionnaire was conducted to check the workers' symptoms and understanding of the work environment. Based on a preliminary investigation, the factors related to IAQ such as temperature, humidity, fine particulate. carbon dioxide, carbon monoxide, formaldehyde, total volatile organic compounds (TVOC), and radon gas were selected and measured for a certain period of time in specific sites where hospital workers stay long in a day. And we also evaluated the surrounding environment and the efficiency of the ventilating system simultaneously, and measured the same factors at the first floor (outdoor) to compare with outdoor all quality, All collected data were assessed by the recommended standard for IAQ of the domestic and international environmental organizations. Results: Hospital workers were discontented with foul odors, humidity and particulate. They complained symptoms related to musculo-skeletal system, neurologic system, and mucosal-irritatation. Most of the factors were not greater than the recommended standard, but the level of TVOC was third or fourth times as much as the measuring level of some offices in the United States. The frequency and the amount of the ventilating system were adequate, however, the problem arising in the position of outdoor-air inlets and indoor-air outlets involved a risk of the indraft of contaminated air. A careful attention was a requirement in handling and keeping chemical substances including a developing solution which has a risk of TVOC emissions, and repositioning the ventilating system was needed to solve the contaminated-air circulation immediately Conclusion We verified that some IAQ-related factors and inadequate ventilating system could cause subjective symptoms in hospital workers. The evaluation of IAQ was surely needed to improve the underground working environments for hospital workers and patients. On the basis of these data, from now on, we should actively engage in designs of the department of radiation oncology or improvement in environments of the existing facilities.

Prioritizing Noxious Liquid Substances (NLS) for Preparedness Against Potential Spill Incidents in Korean Coastal Waters (해상 유해액체물질(NLS) 유출사고대비 물질군 선정에 관한 연구)

  • Kim, Young-Ryun;Choi, Jeong-Yun;Son, Min-Ho;Oh, Sangwoo;Lee, Moonjin;Lee, Sangjin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.7
    • /
    • pp.846-853
    • /
    • 2016
  • This study prioritizes Noxious Liquid Substances (NLS) transported by sea via a risk-based database containing 596 chemicals to prepare against NLS incidents. There were 158 chemicals transported in Korean waters during 2014 and 2015, which were prioritized, and then chemicals were grouped into four categories (with rankings of 0-3) based on measures for preparedness against incident. In order to establish an effective preparedness system against NLS spill incidents on a national scale, a compiling process for NLS chemicals ranked 2~3 should be carried out and managed together with an initiative for NLS chemicals ranked 0-1. Also, it is advisable to manage NLS chemicals ranked 0-1 after considering the characteristics of NLS specifically transported through a given port since the types and characteristics of NLS chemicals relevant differ depending on the port. In addition, three designated regions are suggested: 1) the southern sector of the East Sea (Ulsan and Busan); 2) the central sector of the South Sea (Gwangyang and Yeosu); and 3) the northern sector of the West Sea (Pyeongtaek, Daesan and Incheon). These regions should be considered special management sectors, with strengthened surveillance and the equipment, materials and chemicals used for pollution response management schemes prepared in advance at NLS spill incident response facilities. In the near future, the risk database should be supplemented with specific information on chronic toxicity and updated on a regular basis. Furthermore, scientific ecotoxicological data for marine organisms should be collated and expanded in a systematic way. A system allowing for the identification Hazardous and Noxious Substances (HNS) should also be established, noting the relevant volumes transported in Korean waters as soon as possible to allow for better management of HNS spill incidents at sea.

Estimation of Total Allowable Pollutant Loads Using Eco-hydrodynamic Modeling for Water Quality Management on the Southern Coast of Korea (생태계 모델에 의한 총허용 오염부하량 산정을 통한 연안해역의 수질관리)

  • Lee, Dae-In;Kim, Jong-Kyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.10 no.1
    • /
    • pp.29-43
    • /
    • 2007
  • For effective management of water quality on the southern coast of korea, a three-dimensional eco-hydrodynamic model is used to predict water quality in summer and to estimate the reduction rate in pollutant loads that would be required to restore water quality. Under the current environmental conditions, in particular, pollutant loadings to the study area were very high, chemical oxygen demand (COD) exceeded seawater quality criteria to comply with current legislation, and water quality was in a eutrophic condition. Therefore, we estimated reduction rates of current pollutant loads by modeling. The model reproduced reasonably the flow field and water quality of the study area. If the terrestrial COD, inorganic nitrogen and phosphorus loads were reduced by 90%, the water quality criteria of Region A were still not satisfied. However, when the nutrient loads from polluted sediment and land were each reduced by 70% simultaneously, COD and $Chl-{\alpha}$ were restored. When we reduced the input COD and nutrient loads from the Nakdong River by 80%, $Chl-{\alpha}$ and COD of Region B decreased below $10\;{\mu}g\;1^{-1}$ and $2\;mg\;1^{-1}$, respectively. The water quality criteria of Region C were satisfied when we reduced the terrestrial COD and nutrient loads by 70%. Total allowable loadings of COD and inorganic nutrients in each region were determined by multiplying the reduction rates by current pollutant loads. Estimated high reduction rates, although difficult to achieve at the present time under the prevailing environmental conditions, suggest that water pollution is very severe in this study area, and pollutant loads must be reduced within total allowable loads by continuous and long-term management. To achieve the reduction in pollutant loads, sustainable countermeasures are necessary, including the expansion of sewage and wastewater facilities, polluted sediment control and limited land use.

  • PDF

A Study on Ecological Characteristics and Changes of Vegetation in Hamyangsangrim (함양상림 식생의 생태적 특성 변화 연구)

  • Kim, Dong-Wook;Lee, Seung-Joo;Lee, Soo-Dong;Kim, Ji-Seok;Han, Bong-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.26 no.4
    • /
    • pp.537-549
    • /
    • 2012
  • The purpose of this study was to provide data for the basic research to found the effective conservation and management plan for the Hamyangsangrim designated as Natural Monument No. 154 and surround areas by analyzing the ecological characteristics such as landuse and actual vegetation, plant community structure, soil chemical property and also to identify the tendency of the ecosystem changes through comparison with past studies. According to analysis the results, the landuse and actual vegetation of survey site was classified as 8 types which were forest, artificial greenspace, plaza and open-space, bare ground and the pavement, water bodies, facilities, agricultural land and etc.. It was also categorized as 38 types according to detailed characteristic. 15 kinds of forest vegetation community types comprising silva were classified among them. The changes of actual vegetation showed little variation that the Quercus serrata-Carpinus tschonoskii forest was the most widely distributed in 2003(forest area ratio is 48.3%) and 2010(forest area ratio is 48.1%), whereas, the Quercus serrata forest declined a more dramatic from 11.6% to 23.2%. The Quercus serrata-Carpinus tschonoskii forest increased sharply(11.6% ${\rightarrow}$ 23.2%) and also the Quercus serrata-Zelkova serrata forest increased steadily(2.2% ${\rightarrow}$ 7.9%). The agricultural land around forest was transformed into artificial green zone. Moreover, water bodies, bare ground and the pavement of areas have increased. In addition, the urbanized area has decreased because the damaged areas inside forest have been restored to the woodlands. According to the result of typical 6 types vegetation communities change, the middle layer trees grew up to the canopy layer trees and was formed the canopy layer structure. The middle layer trees expanded their forces widely. Also new species appeared. And the shrub individuals also more dramatically increased due to the growth of shrubs. The force of Quercus serrata declined as well. However the force of Carpinus tschonoskii and Zelkova serrata expanded and increased in the forest. It must be the result of the ecological vegetation succession and environmentally soundly health recovery by influence of the projects of forest surrounding environment improvement and limitation of access to forest have managed and maintained since 2003. Those sorts of changes seems to be going to develop continuously. In the future Carpinus tschonoskii and Zelkova serrata will not be only codominant in the canopy layer but also Carpinus Tschonoskii, Zelkova serrata, Meliosma myriantha, Sapium japonicum. Styrax obassia and Acer pseudo-sieboldianum will be codominant in the middle layer. As a result, the forest's codominance species are going to be changed such like that.

Industrial restructuring and uneven regional development in the 1980s (산업구조조정과 지역불균등발전 : 1980년대)

  • ;Choi, Byung-Doo
    • Journal of the Korean Geographical Society
    • /
    • v.29 no.2
    • /
    • pp.137-165
    • /
    • 1994
  • Structural adjustment of industry (or industrial restructuring) seems to be inherent in the process of capitalist economic development, which tends to be proceeded with shifts from one stage to another in order to overcome structural crises generated in each stage. The structural adjustment of industry is necessarily accompanied with regional restructuring, since it is not only projected on spece, but also mediated by space. Such a restructuring necessitates industrial and uneven regional devlopment through which capital can seek excessive profits over the rate of socio-spatial average. The industrial restructuring and uneven regional development in the 1980s in Korea can be seen as a process in which capital attempted with a strong support of the govenment to overcome the crises in the end of 1970s and hence to go on rapid economic growth. In this process, capital, especially monopoly capital concentrated into few conglomerates, pursued both extensive expansion and intensive development of industry simultaneously. In results, the Korean economy could eliminate some of peripheral characters and maturate the Fordist accumulation system. The extensive expansion of the Korean industry in the 1980s was stimulated mainly through the enlargement and adjustment of investment for equipment facilities which was planned to exclude or rationalize traditional light industries on some places, and to continue rapid growth of key heavy-chemical industries, especially of fabricated metal industry, on other places. In this process, keeping mainly the existing developmental axis which polarized the Seoul Metroplitan region and the Southeast region in Korea, the enhancing spatial mobiiity of capital and the further differentiating division of labour enforced a tendency of concentration of all types of industry in the Seoul Metropolitan region, and at the same time provoked the diffusion of some industries over Jeolla and Chungchong regions in a considerable extent. The intensive development of industriai structure in the 1980s was pursued through the strategic encouragement of subcontracting small firms mainly which produced assembling components, the technical enhancement and factory (semi-) automation, and the enrichment of service industries for estate management, finance, distribution and retailing which supported and complemented the production of goods. In this process, enabling capital to extend and elaborate its domination over space through the reorganization of regulating systems, the Fordist division of labour generated a socio-spatial hierarchy in the nation-wide scale that characterized: the Seoul Metropolitan region as an overmaturated (or overarching) Fordist region performing the conceptive functions of management, research and development, in which all types of industry (including service industries) tended to be reconcentrated; Kyungsang region as a maturated Fordist region with excutive branches of large conglomerates and with subcontracting firms around them which produced standardized products through the automized production processes in secialized Fordist industries or rationalized traditional industries; and Jeolla and Chungchong regions as newly devloping Fordist regions with newly migrated branches and some subcontracting small firms-in relatively older Fordist industries or partly rationalized traditional industries. From these analyses, it can be argued that the structural adjustment of the Korean industry in the 1980s, which had carried out both through the extensive expansion and the intensive deveiopment, strengthened further uneven regional development process, even though it appears to have reduced apparently the economic and regional disparity by balancing numerically large and small firms and by extending the Fordist industrial space nation-wideiy. And it seems more persuasive to see that the Korean industrial structure in the 1980s maturated the Fordist system of accumulation, but not yet transformed towards the post-Fordist (or the so-called flexible) accumulation system, even though the Korean economy in the 1990s seems to be under a pressure of restructuring towards the latter system.

  • PDF

Simultaneous Removal of NO and SO2 using Microbubble and Reducing Agent (마이크로버블과 환원제를 이용한 습식 NO 및 SO2의 동시제거)

  • Song, Dong Hun;Kang, Jo Hong;Park, Hyun Sic;Song, Hojun;Chung, Yongchul G.
    • Clean Technology
    • /
    • v.27 no.4
    • /
    • pp.341-349
    • /
    • 2021
  • In combustion facilities, the nitrogen and sulfur in fossil fuels react with oxygen to generate air pollutants such as nitrogen oxides (NOX) and sulfur oxides (SOX), which are harmful to the human body and cause environmental pollution. There are regulations worldwide to reduce NOX and SOX, and various technologies are being applied to meet these regulations. There are commercialized methods to reduce NOX and SOX emissions such as selective catalytic reduction (SCR), selective non-catalytic reduction (SNCR) and wet flue gas desulfurization (WFGD), but due to the disadvantages of these methods, many studies have been conducted to simultaneously remove NOX and SOX. However, even in the NOX and SOX simultaneous removal methods, there are problems with wastewater generation due to oxidants and absorbents, costs incurred due to the use of catalysts and electrolysis to activate specific oxidants, and the harmfulness of gas oxidants themselves. Therefore, in this research, microbubbles generated in a high-pressure disperser and reducing agents were used to reduce costs and facilitate wastewater treatment in order to compensate for the shortcomings of the NOX, SOX simultaneous treatment method. It was confirmed through image processing and ESR (electron spin resonance) analysis that the disperser generates real microbubbles. NOX and SOX removal tests according to temperature were also conducted using only microbubbles. In addition, the removal efficiencies of NOX and SOX are about 75% and 99% using a reducing agent and microbubbles to reduce wastewater. When a small amount of oxidizing agent was added to this microbubble system, both NOX and SOX removal rates achieved 99% or more. Based on these findings, it is expected that this suggested method will contribute to solving the cost and environmental problems associated with the wet oxidation removal method.

An Optimization Study on a Low-temperature De-NOx Catalyst Coated on Metallic Monolith for Steel Plant Applications (제철소 적용을 위한 저온형 금속지지체 탈질 코팅촉매 최적화 연구)

  • Lee, Chul-Ho;Choi, Jae Hyung;Kim, Myeong Soo;Seo, Byeong Han;Kang, Cheul Hui;Lim, Dong-Ha
    • Clean Technology
    • /
    • v.27 no.4
    • /
    • pp.332-340
    • /
    • 2021
  • With the recent reinforcement of emission standards, it is necessary to make efforts to reduce NOx from air pollutant-emitting workplaces. The NOx reduction method mainly used in industrial facilities is selective catalytic reduction (SCR), and the most commercial SCR catalyst is the ceramic honeycomb catalyst. This study was carried out to reduce the NOx emitted from steel plants by applying De-NOx catalyst coated on metallic monolith. The De-NOx catalyst was synthesized through the optimized coating technique, and the coated catalyst was uniformly and strongly adhered onto the surface of the metallic monolith according to the air jet erosion and bending test. Due to the good thermal conductivity of metallic monolith, the De-NOx catalyst coated on metallic monolith showed good De-NOx efficiency at low temperatures (200 ~ 250 ℃). In addition, the optimal amount of catalyst coating on the metallic monolith surface was confirmed for the design of an economical catalyst. Based on these results, the De-NOx catalyst of commercial grade size was tested in a semi-pilot De-NOx performance facility under a simulated gas similar to the exhaust gas emitted from a steel plant. Even at a low temperature (200 ℃), it showed excellent performance satisfying the emission standard (less than 60 ppm). Therefore, the De-NOx catalyst coated metallic monolith has good physical and chemical properties and showed a good De-NOx efficiency even with the minimum amount of catalyst. Additionally, it was possible to compact and downsize the SCR reactor through the application of a high-density cell. Therefore, we suggest that the proposed De-NOx catalyst coated metallic monolith may be a good alternative De-NOx catalyst for industrial uses such as steel plants, thermal power plants, incineration plants ships, and construction machinery.